• Title/Summary/Keyword: Safety measurement

Search Result 2,511, Processing Time 0.04 seconds

A Study on the Health Evaluation in Spot Welded Zone by Using Optical Pulse and Lock-in Phase Infrared Thermography (광원 펄스와 위상잠금 적외선 열화상을 이용한 점용접부의 건전성 평가 연구)

  • Park, Hee Sang;Choi, Mang Yong;Kwon, Koo Ahn;Park, Jeong Hak;Kim, Won Tae;Lee, Bo Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.349-354
    • /
    • 2013
  • The non-destructive testing using infrared thermography is extended to a variety of industries and non-destructive testing of welds using infrared thermography is also in progress in various ways. Currently, a non-destructive testing of electrical resistance spot welds which is mainly used is Radiography Testing. This study detected area of spot welds nugget using optical-infrared thermography. In the results, it is possible for detecting defects of nugget in a short period of time using pulse-infrared thermography.

Fabrication of Phased Array EMAT and Its Characteristics (위상배열 EMAT의 제작 및 특성 평가)

  • Ahn, Bong-Young;Cho, Seung-Hyun;Kim, Young-Joo;Kim, Ki-Bok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.373-379
    • /
    • 2010
  • EMAT has been applied in various fields for flaw detection and material characterization because it has noncontact property in wave generation and a good mode selectivity. Unfortunately, however, EMAT shows low signal to noise ratio relative to commercial contact transducer because of low energy conversion efficiency. If the phase matching through the control of time delay between each coil consisting of the array EMAT is accomplished, it is expected that it will be a solution for the improvement of low signal to noise ratio. In this experiment, the phased array EMATs which consists of 3 or 4 meander coils and one big magnet were fabricated for surface and vertical shear wave generation. Effect of phased delay control on signal directivity and amplitude enhancement was verified. A slit with the depth of 0.5 mm and a side-drill hole of 0.5 mm diameter were clearly detected by fabricated phased array EMATs, respectively.

Developing A Tool to Execute Children's Food Service Hygiene and Safety Management (어린이 급식소 위생·안전관리 수행 도구 개발)

  • Lee, Jin-Young
    • The Korean Journal of Food And Nutrition
    • /
    • v.29 no.2
    • /
    • pp.253-266
    • /
    • 2016
  • The current study was conducted to facilitate appropriate hygiene and safety management in children's food service stations, with the ultimate objective of providing sanitary and safe food service to children. In order to develop questionnaire items, literature review was conducted, in addition to detailed interview of working-level personnel at a children's food service management support center. This resulted in a total of thirty questions on personal hygiene management, food materials hygiene management, and facilities hygiene management. Using the questionnaire, seventy-one food service stations for children in District A in Seoul that serve less than one hundred children were surveyed to analyze the reliability, construct validity, and correlation in the developed measurement tool. The developed measurement tool consisted of ten task and environmental hygiene management questions, five personal and cooking hygiene management questions, four food ingredient and storage hygiene management questions, and four food service operation and management question; with a total of twenty-three questions, in four factors stated above. The cumulative distribution of the four factors was 54.698%, and Cronbach's ${\alpha}$ value was 0.672~0.853, which indicated that the study was reliable. The results of the analysis indicated that each of the factors were correlated, the study was satisfactory, and the tool was valid for evaluating hygiene and safety management practices in children's food service stations. Finally, in order to enhance practical utility of the developed measurement tool, the significance and limitations were described.

Analysis of Exposure Levels for Inorganic Acids in Korea (무기산류에 대한 국내 작업환경측정 현황 분석)

  • Park, Hae Dong;Park, Seung-Hyun;Jung, Kihyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.31 no.3
    • /
    • pp.255-265
    • /
    • 2021
  • Objectives: The purpose of this study is to analyze the exposure characteristics of inorganic acids. Methods: We analyzed exposure data (n = 363,146) for six inorganic acids (hydrogen fluoride, hydrogen bromide, hydrogen chloride, phosphoric acid, nitric acid, and sulfuric acid) collected between 2017 and 2019 in South Korea. Measurement characteristics and exposure levels (ELs) were analyzed by inorganic acid, industry category, enterprise size, and measurement year. Results: Measurement percentage dominated in time-weighted average (TWA, 91%) compared to short term exposure limit (STEL) and Ceiling. Most of the measurements (79.7%) were collected from the manufacturing category of industry. Medians of ELs were mostly low (≤3% of the threshold limit), with the exception of sulfuric acid (4.6% of TWA and 10.5% of STEL). The percentages of exceeding 1% of the occupational exposure limits (OELs) in TWA were relatively high for sulfuric acid (35.8%) and hydrogen chloride (16.5%) compared to the other acids (4.2%-6.6%). In addition, the percentages of exceeding 1% of OELs in STEL or Ceiling were higher for sulfuric acid (22.9%), hydrogen chloride (12.3%), and nitric acid (8.2%) compared to the other acids (1.2%-1.9%). The small-sized enterprises showed higher ELs in TWA; contrarily, the large-sized enterprises had higher ELs in STEL or Ceiling. Conclusions: The measurement characteristics and ELs identified in this study could be useful for establishing safety and health policies for inorganic acids.

Performance Evaluation of Hazardous Substances using Measurement Vehicle of Field Mode through Emergency Response of Chemical Incidents

  • Lee, Yeon-Hee;Hwang, Seung-Ryul;Kim, Jae-Young;Kim, Kyun;Kwak, Ji Hyun;Kim, Min Sun;Park, Joong Don;Jeon, Junho;Kim, Ki Joon;Lee, Jin Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.34 no.4
    • /
    • pp.294-302
    • /
    • 2015
  • BACKGROUND: Chemical accidents have increased owing to chemical usage, human error and technical failures during the last decades. Many countries have organized supervisory authorities in charge of enforcing related rules and regulations to prevent chemical accidents. A very important part in chemical accidents has been coping with comprehensive first aid tool. Therefore, the present research has provided information with the initial applications concern to the rapid analysis of hazardous material using instruments in vehicle of field mode after chemical accidents. METHODS AND RESULTS: Mobile measurement vehicle was manufactured to obtain information regarding field assessments of chemical accidents. This vehicle was equipped with four instruments including gas chromatography with mass spectrometry (GC/MS), Fourier Transform Infrared Spectroscopy (FT-IR), Ion Chromatography (IC), and UV/Vis spectrometer (UV) to analyses of accident preparedness substances, volatile compounds, and organic gases. Moreover, this work was the first examined the evaluation of applicability for analysis instruments using 20 chemicals in various accident preparedness substances (GC/MS; 6 chemicals, FT-IR; 2 chemicals, IC; 11 chemicals, and UV; 1 chemical) and their calibration curves were obtained with high linearity ( r 2 > 0.991). Our results were observed the advantage of the high chromatographic peak capacity, fast analysis, and good sensitivity as well as resolution. CONCLUSION: When chemical accidents are occurred, the posted measurement vehicle may be utilized as tool an effective for qualitative and quantitative information in the scene of an accident owing to the rapid analysis of hazardous material.

Effects of Position of Auxiliary Probe on Ground Resistance Measurement Using Fall-of-Potential Method

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2008
  • In this paper, the effects of the position and the angle of the potential probes on the measurements of the ground resistance using the fall-of-potential method are described and the testing techniques for minimizing the measuring errors are proposed. The fall-of-potential method is theoretically based on the potential and current measuring principle and the measuring error is primarily caused by the position and angle of auxiliary probes. In order to analyze the relative error in the measured value of the ground resistance due to the position of the potential probe, the ground resistance was measured for the case in which the distance of the current probe was fixed at 50[m] and the distance of the potential probe was located from 10[m] to 50[m]. Also, the potential probe was located in turn at $30[^{\circ}]$, $45[^{\circ}]$, $60[^{\circ}]$, $90[^{\circ}]$, and $180[^{\circ}]$. As a consequence, relative error decreased with increasing distance of the potential probe and decreasing angle between the current probe and potential probe. The results could help to determine the position of the potential probe during the ground resistance measurement.

A study on laser technology for measurement of wheel/rail interaction force (차륜/레일 작용력 측정을 위한 레이저기술 연구)

  • Ham Y. S.;Seo J. W.
    • Proceedings of the KSR Conference
    • /
    • 2003.05a
    • /
    • pp.674-678
    • /
    • 2003
  • This research is develop the sensing and measurement technology for measure that wheel/rail interaction force to use laser. Investigated existent laser measurement system, and examined transformation by load that action to wheel for achieve research purpose. A proposed to laser measurement system composition plan to analyze existent method that measure wheel/rail interaction force.

  • PDF

A survey on the visual fatigue measurement methods (시각피로의 측정방법에 관한 조사연구)

  • 이남식;박재희;김유창
    • Proceedings of the ESK Conference
    • /
    • 1994.04a
    • /
    • pp.32-37
    • /
    • 1994
  • This paper surveys the various methodologies for the objective measurement of visual fatigue. Visual fatigue is a psychophysiological symtom caused by the excessive use of eyes and it can be used as an important measure of the effectiveness and the safety of visual displays. The purpose of this paper is to compare the various visual fatigue measurement methodologies in a sense of the suitability for the ergonomic research. The measurement methodologies based on accommodation, convergence, visual evoked potential, eye movement, eye blinking, and flicker fusion were discussed and compared.

  • PDF

Evaluation of Radiation Doses of Dental Portable Equipment (치과용 이동형 방사선장치의 선량평가)

  • Park, Hoon-Hee;Kang, Byung-Sam
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.445-450
    • /
    • 2018
  • We aim to evaluate safety of radiation by measuring leakage dose and patient(phantom) incident dose of ZEN-PX II dental portable equipment developed by G company. Measurement for leakage dose of equipment is conducted on the top, at the bottom, on the left, on the right and at the back. Dose measurement incident on the subject with the area dosimeter when using the phantom and measurement the leakage dose of equipment when using the phantom are evaluated. Comparing the right with the highest leakage dose as a 0 cm, 25 cm, 50 cm, 75 cm and 100 cm dose measurement at the measurement height of 100 cm, 64.2 uR was reduced to 47.3 uR in the senser mode 0.32sec. Even in film mode it was measured at 414.4 uR and about 27% lower at 162.6 uR. As the result of this study, when the irradiation time is 2 sec the right side dose is 290.5 uR and sensor mode is 0.32 sec the right side dose is 64.2 uR.

Vision-based multipoint measurement systems for structural in-plane and out-of-plane movements including twisting rotation

  • Lee, Jong-Han;Jung, Chi-Young;Choi, Eunsoo;Cheung, Jin-Hwan
    • Smart Structures and Systems
    • /
    • v.20 no.5
    • /
    • pp.563-572
    • /
    • 2017
  • The safety of structures is closely associated with the structural out-of-plane behavior. In particular, long and slender beam structures have been increasingly used in the design and construction. Therefore, an evaluation of the lateral and torsional behavior of a structure is important for the safety of the structure during construction as well as under service conditions. The current contact measurement method using displacement meters cannot measure independent movements directly and also requires caution when installing the displacement meters. Therefore, in this study, a vision-based system was used to measure the in-plane and out-of-plane displacements of a structure. The image processing algorithm was based on reference objects, including multiple targets in Lab color space. The captured targets were synchronized using a load indicator connected wirelessly to a data logger system in the server. A laboratory beam test was carried out to compare the displacements and rotation obtained from the proposed vision-based measurement system with those from the current measurement method using string potentiometers. The test results showed that the proposed vision-based measurement system could be applied successfully and easily to evaluating both the in-plane and out-of-plane movements of a beam including twisting rotation.