• Title/Summary/Keyword: Safety measure

Search Result 1,856, Processing Time 0.034 seconds

A Vision-based Pipe Support Displacement Measurement Method Using Moire Patterns (모아레 현상을 이용한 영상기반 파이프 서포트 변위측정 방법)

  • Park, Junbeom;Park, Semi;Kim, Jaehyeon;Kim, Jungyeol
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.1
    • /
    • pp.37-45
    • /
    • 2022
  • It is very important to measure the displacement of a structure to evaluate the safety of the structure. This study shows a methodology to measure the displacement to determine the stability of a structure when it is damaged by loads. The methodology used Moiré's phenomenon and was verified through experiments. The experiments utilized pipes to simulate the pipe supports in the construction site and measured the vertical displacement of the Moiré interference patterns according to the horizontal displacement of the pipes. Experiments confirmed that the linear relationship between horizontal displacement of pipes and vertical displacement of Moiré patterns and derive a relational expression. In conclusion, the methodology presented in this work allows us to simultaneously measure a number of vertical members' displacements regardless of distance and determine the safety of the structure.

Safety Consciousness of the Elderly Living Alone (독거노인의 안전의식과 낙상)

  • Kang, Youngsil;Jung, Sun Jae
    • Journal of muscle and joint health
    • /
    • v.20 no.3
    • /
    • pp.180-188
    • /
    • 2013
  • Purpose: This study aims to explore the effect of physical, emotional and environmental status on safety consciousness of the elderly who live alone. Methods: A total of 228 participants were the elderly living alone aged 65 years and older. Three questionnaires were developed to measure safety consciousness, physical status, and environmental status by researchers. Geriatric Depression Scale (GDS) was used to evaluate emotional status of the elderly. Data were analyzed by t-test, ANOVA, Pearson's correlation coefficients, and stepwise multiple regression. Results: Average scores of participants were $3.71{\pm}1.49$ (range 0~6) for physical status, $8.28{\pm}3.38$ (range 0~15) for environmental status, $7.21{\pm}3.40$ (range 0~15) for GDS and $17.00{\pm}6.54$ (range 0~37) for safety consciousness. Safety consciousness was significantly associated with education, marital status, drinking, and depression as emotional status. These variables explained 13.6% of the variance in safety consciousness. Conclusion: The levels of safety consciousness among the elderly living alone were low. Education, marital status, drinking, and depression were the factors affecting safety consciousness. Risk assessment and management of these factors are needed to increase safety consciousness of the elderly.

Analysis of Properties of UV Corona on Insulator in Salt Water Environments (염수 환경 열화 상태를 모의한 절연애자의 자외선 코로나 특성 분석)

  • Kim, Young-Seok;Choi, Myeong-Il;Kim, Chong-Min;Bang, Sun-Bae;Shong, Kil-Mok;Lee, Myeong-Jun;Lee, Woo-Chang
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1590-1591
    • /
    • 2011
  • In this paper, the UV corona camera was developed using the solar blind and Multi Channel Plate(MCP) technology for the target localization of UV camera. UV camera developed a $6.4^{\circ}{\times}4.8^{\circ}$ of the field of view as a conventional camera to diagnose a wide range of slightly enlarged, and power equipment to measure the distance between the camera and the distance meter has been attached. The UV camera was developed and measured using a UV image, as applied voltage increased ultraviolet images of the phenomenon could be obtained. And we investigated properties of UV corona image on insulator in salt water environments. From the results, the breakdown voltage was decreased and UV images were taken at low voltages and the UV image is rapidly increased with increasing High voltage.

  • PDF

A Study on Legal Limits of Occupational Safety & Health Law and Application of Private Standards (산업안전보건법의 한계와 민간기준의 활용에 관한 연구)

  • Jung, Jinwoo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.2
    • /
    • pp.103-112
    • /
    • 2014
  • Objectives: The present system of occupational safety and health law gives priority to traditional command and control regulations. However, this may give rise to problems such as the delay of standard-setting and shortages of human resources. The aim of this study is to examine the usability of private standards in occupational safety and health systems. Materials: After the limits of occupational safety and health law were examined, an application plan for private norms (EN, as enforced in the EU) and occupational safety and health management systems (OSHMS) was investigated. Results: The utilization of private norms and OSHMS may address the limits of the current legal system. In particular, OSHMS is known internationally as a measure for achieving improvements in overall occupational safety and health performance. As a result, occupational safety and health law and private norms/OSHMS are complementary to one another. Conclusions: Even though the utilization of private standards may give rise to legal questions, such standards as complementary measures to traditional command and control regulations need to be utilized progressively in occupational safety and health systems.

A Study on the Factors Influencing Safeness of Work Environment in Manufacturing Industry (제조업 근로자의 작업환경안전에 영향을 미치는 요인에 관한 연구)

  • Kwon, Oh-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.77-83
    • /
    • 2009
  • The manufacturing industry is the one with the most frequent industrial disasters, and it is important to study the safety climate recognized by workers in the industry in order to actively prevent industrial accidents. However, little research has been performed on the safety climate in workplaces felt by the workers in the manufacturing industry. The purpose of this study is to identify the factors affecting work environment safeness based on practical analysis via survey, and to establish the relation between safety performance factors and safeness of work environment. The survey was performed for workers in the manufacturing industry(n=228), and structural equations model analysis by using the AMOS 7.0 was performed in order to identify the fit of the research model and the causation among factors. According to the results of the analysis, the reliability and the model fit were appropriate for interpretation, and safety participation was shown to affect safeness of work environment more than safety compliance. The results of this study may serve as the reference for taking a measure to improve the level of safeness of the work environment felt by workers in the manufacturing industry.

Development and Performance Test of Online Electrical Safety Monitoring System Applying an Algorithm to Measure Resistive Leakage Currents using Phase Differences (위상차를 이용한 저항성 누설전류 측정 알고리즘을 적용한 온라인 전기안전 감시시스템의 개발 및 성능시험)

  • Yoo, Jeong Hyun;Kim, Hie Sik;Jeong, Yong Wook
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.27-32
    • /
    • 2018
  • Nowadays, to prevent electrical accidents in Korea, inspectors directly performed checking general electrical facilities as a cycle from every one to three years. It is difficult to presuppose an omen because intact conditions of electrical equipments are not kept at the time of inspection. In this paper, in order to ensure effectiveness of an online basis electric inspection, we developed an electrical safety IoT system using LoRa communication technology to enable monitoring mainly electrical safety components such as overcurrent, overvoltage, resistive leakage current, and power. Then we proposed a method for verifying performances of the prosed electrical safety IoT system. Resistive leakage currents are calculated by using difference of phase between voltages and currents. We verified that average errors are 0.97%, which reference goal is ${\pm}5%$ for a device, through reliability test according to conditions. Results of this research can be used as basic study materials to develop technologies for measuring three phase leakage current and for implementing public electrical safety. platform.

Improving Current Status of Safety Management for Domestic Performance Theatre (국내 공연장 안전관리 실태 및 개선 대책에 관한 연구)

  • Gal, Won-Mo
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.3
    • /
    • pp.35-41
    • /
    • 2008
  • It is a fact that domestic performance art has been sharply progressed but it is focused on only performance quality technique, not on safety of performers and the audience. It is a pity that people's effort to keep safe stage environment have not traced to innovative change, eventually leading to be forced to perform under hazardous condition. This study is to find out and identify that domestic regulation and accident cases are investigated and compared with cases of advanced countries, to verify that performer and the audience are main elements to develop performance art. And it is to show more effective safety measure after pointing out hazardous elements. Research change is limited to review only performance ones of all cultural facilities and to review accident cases from these places to show reasonable safety measures for stage facilities. Operation manager covers almost all of areas such as devices, management, despite a fact that they take charge of stage facilities, illumination, sounds, already. Some conclusions are as follows; 1) performance theatre-related regulations should be established again. domestic safety standards for performance theatre safety should be established. 2) characteristic and purpose of performance place should be clarified at the stage planning and design of them 3) operation expert performance place is required to be trained to cover emergency situation at any time.

Study on the Evaluation Method of Electrical Isolation Property for Hydrogen Fuel Cell Vehicle in Post Crash (수소연료전지자동차의 충돌시 절연성능 평가방법에 관한 고찰)

  • Lee, Kiyeon;Gil, Hyoungjun;Kim, Dongook;Kim, Dongwoo;Kang, Daechul
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.6
    • /
    • pp.612-618
    • /
    • 2012
  • In this paper, in order to prevent electric shock of high voltage system of HFCV after crash test, insulation performance measurement methods were studied. Under conditions of in-use, insulation performance tests can be divided into measurement method using the vehicle's own RESS as DC voltage source and measurement method using DC voltage from off-vehicle sources. However, these tests can not be applied after a post-crash because parts of high voltage system cover should be removed, and insulation performance can be influenced during these tests. Therefore, we proposed post-crash insulation performance test methods for preventing electric shock through problem analysis of previous post-crash insulation performance tests. Also, test equipment which can measure voltage absence and total energy was developed. We verified performance of the equipment through experiments with vehicle test.

The Effects of Smartphone Application to Educate Patient on Patient Safety in Hospitalized Surgical Patients (위해사건 예방을 위한 수술 환자 교육용 스마트폰 애플리케이션의 효과)

  • Choi, Hyo Jin;Lee, Eunjoo
    • Korean Journal of Adult Nursing
    • /
    • v.29 no.2
    • /
    • pp.154-165
    • /
    • 2017
  • Purpose: This study was designed to evaluate a patient safety application in the prevention of adverse event among surgical patients. Seventy three surgical patients with thirty six of them using the patient safety application and the rest (N=37) were provided educational booklet. Further, the instrument would measure patients' right to know, knowledge about patient safety, and attitude toward patient safety. Methods: The patient safety application was developed by the ADDIE along with input from experts, patients and an extensive literature review. Data were collected from 7 September through 20 October 2015. Results: The experimental group had significantly higher scores in patients' right to know (t=2.01, p=.024), knowledge on patient safety (t=3.80, p<.001) and attitude toward patient safety (t=2.74, p=.004) than those of the control group. Conclusion: The patient safety application developed using Smartphone could be an effective tool enhancing patient involvement in preventing adverse events that may occur to patients. Further studies are recommended with diverse subjects with varying medical conditions.

The Safety Survey Analysis and Consideration of Small Transformer (소형 변압기 안전성 실태 분석 및 고찰)

  • Kim, Sung-Sam
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.2
    • /
    • pp.1-6
    • /
    • 2014
  • In this paper, safety certification products and safety condition of small transformer is analyzed in industries field and educational facilities. In transformer of 50places, absolute majority is step down transformer to measure of instrument. Most transformers were below 5kVA and 1~3kVA capacity was the mainstream. In industries field, 5 transformers were found without safety certification according to the Electrical Appliances Safety Control Act as cheap product prefer and lack of safety consciousness. Mark & number, voltage, date of manufacture of safety certification must show item of certification. However date of manufacture showed in product of 18%, 9places. As result of thermal imaging camera, running temperature of transformer was showed in below of target temperature. However as a narrow space of transformer and wall, power cable was touched on a ventilating flue in transformer. It was simple carelessness case that surface fouling and temperature ageing of transformer accelerate. Power poor connection, neglect of transformer in production equipment, fall damage by setup incongruity and ground omission were found in case of illogicality item of transformer.