• Title/Summary/Keyword: Safety lines

Search Result 561, Processing Time 0.027 seconds

The Study on the AC Interference of High Power Cable on Underground Gas Pipeline (전력케이블과 가스배관의 병행구간에 대한 교류부식 영향 검토 연구)

  • Bae, J.H.;Kim, D.K.;Ha, T.H.;Lee, H.G.;Kwak, B.M.;Lim, C.J.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07a
    • /
    • pp.470-473
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power. Therefore, there has been and still is a growing concern (safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline. especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion, limitation of safety voltage and analysis of indiction voltage.

  • PDF

A study on the Analysis of Combustion Gas and its Flow Induced by Fire in an Enclosure (밀폐공간내 화재에 의해 생성된 연소가스 분석 및 유동에 관한 연구)

  • 추병길;조성곤
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.77-93
    • /
    • 1997
  • The natural convection and combined heat transfer induced by fire in a rectangular enclosure is numerically studied. The model for this numerical analysis is partially opened, it is divided by a vertical baffle projecting from ceiling. The solution procedure Includes the standard k- $\varepsilon$ model for turbulent flow and the discrete ordinates method (DOM ) is used for the calculation of radiative heat transfer equation. In this study, numerical simulation on the combined naturnal convection and radiation is carried out in a partial enclosure filled with absorbed-emitted gray media, but is not considered scattering problem. The velocity vectors, streamlines, and isothermal lines are compared the results of pure convection with those of the combined convection-radiation, the combined heat transfer. Comparing the results of pure convection with those of the combined convection-radiation, the combined heat transfer analysis shows the stronger circulation than those of the pure convection. Three different locations of heat source are considered to observe the effect of heat source location on the heat transfer phenomena. As the results, the circulation and the heat transfer In the left region from heating block are much more influenced than those in the right region. It is also founded that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF

A Study on the Environmental Radiation of Concrete Apartments and Neighborhood Living Facilities (콘크리트 공동주택과 근린생활 시설의 환경방사선에 관한 연구)

  • Ji, Tae-Jeong;Kwak, Byung-Joon;Min, Byung-In
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.2
    • /
    • pp.100-104
    • /
    • 2009
  • In this study, the space gamma dose rates in the apartments structured with concrete were measured in accordance with construction year. In addition, the environmental radiation rates coming from the subway platforms and the road tunnels were analyzed in the equivalent dose by multiplying the absorbed dose with the radiation weighting factors. The space gamma dose rates measured in apartments were higher than those of outdoor which was $0.08{\sim}0.11uSv/h$ in the natural conditions. Especially, the older construction year is, the higher becomes space gamma dose rate. The average gamma dose rates in the subway platforms were measured. In the case of Busan and Daegu subway, the earlier the opening year is, the higher becomes dose rate. However, the dose rates of Seoul subway Lines were high overall, regardless of opening year. Seoul subway Line 6 showed the highest value of 0.21uSv/h. The gamma dose rate in road tunnels was higher than one of the outdoor and increased with opening year like as apartment. In dose rate comparison of the concrete structures with the outdoor, therefore, the space gamma dose rate of indoor is higher than one of the outdoor and the older structures have a higher dose rate.

Safe Industrial Manipulator Based on a Counterbalancing Mechanism with Adaptation to the Posture Change of a Robot Base Plane (로봇 설치면 자세 변화에 대응 가능한 자중 보상 기반 안전 매니퓰레이터)

  • Do, Hyun Min;Kim, Hwi-Su;Kim, Doo Hyeong;Choi, Tae-Yong;Park, Dong Il;Son, Youngsu
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.6
    • /
    • pp.511-516
    • /
    • 2016
  • Guaranteeing the safety of human workers around robots has become an important issue with the increasing demand for human-robot collaboration in industrial production lines. This study proposes a robot manipulator equipped with a counterbalancing mechanism that reduces the power of actuators required to drive the robot, thus keeping a human worker safer in a human-robot collaborative environment. A counterbalancing torque that exactly cancels out the gravitational torque in the proposed mechanism is generated by restoring the force of a spring in the counterbalancing mechanism. A prototype design and experimental results are presented to verify the effectiveness of the proposed method.

A modified Importance-Satisfaction analysis using Kano's model (Kano 모델을 이용한 수정된 중요도-만족도 분석)

  • Song, Hae-Geun
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.241-248
    • /
    • 2013
  • Importance-Performance Analysis(IPA) is a well-known methodology to find the area for improvement. However, the IPA uses different strategies depending on an attribute falls in either 'Concentrate', 'Keep up', 'Possible overkill', or Low priority' quadrant. Problems can occur when attributes locate near the demarcation lines. To solve this problem of IPA, I suggest a modified importance-satisfaction analysis which integrates the Slack(1994)'s diagonal approach and Kano's ASC(Jang et al., 2012) into Yang(2003)'s Importance-Satisfaction model. For this, I investigated 21 smartphone's quality attributes, which adopted from Song and Park(2012)'s study, and conducted a survey of 280 university students for the results of Kano' model and the importance and satisfaction of the quality attributes. The results show that the proposed model enables the business managers to prioritize the quality attributes for improvement through the interpretation on the continuous diagonal line using the Kano's questionnaire only, without acquiring any additional survey for importance of attributes. Accordingly, it is expected that the newly proposed method will diminish the limitation of the existing IPA. In addition, to test the validity of the ASC, this study conducts a comparative analysis between the Kano's ASC and Tontini(2007)'s method to determine the relative importance of quality attributes.

A Case Study on Failure and Analysis of Air Over Hydraulic Brake Line (공기 유압식 브레이크 라인 파손 사례 및 파손 분석 연구)

  • Park, Jeongman;Park, Jongjin
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.2
    • /
    • pp.47-55
    • /
    • 2020
  • In this case study, the brake line failure of air over hydraulic(AOH) brake system is described. AOH brake system is applied to commercial vehicles between 5 to 8 tons. It consists of a hydraulic system using compressed air and operates the air master to form hydraulic pressure to transfer braking power to the wheels. When the brake lines of the system applied to vehicles with high load capacity are damaged, the braking force of one shaft is lost, and the braking distance increases rapidly, leading to a big accident. Failure of the brake line occurs due to various causes such as road surface fragmentation, corrosion of the line, and aged deterioration of air brake hose. The braking force could be decreased even when a very small break in the form of a pin-hole occurs. However, it is difficult to find a part where the thickness of the line is thin due to stone pecking or corrosion generated in the pin-hole formed on the brake line located under the lower part of the vehicle by the sensory evaluation or the conventional braking force test. Accordingly, it is necessary to analyze the condition and cause of the failure of the brake line more precisely when the accident investigation of the heavy vehicles, and also to examine the necessity of the advanced test for the aged brake line.

Multi-objective Optimization of Marine 3/2WAY Pneumatic Valve using Compromise Decision-Making Method (절충의사결정방법을 이용한 선박용 3/2WAY 공압밸브의 다목적 최적설계)

  • Kim, Jun-Oh;Baek, Seok-Heum;Kim, Tae-Woo;Kang, Sangmo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.2
    • /
    • pp.81-90
    • /
    • 2013
  • A study on the flow-structure characteristics of marine 3/2WAY pneumatic valve is essential for optimizing the performance of ship engines. It is important that the valve has desirable safety factor and reduced weight from safety and economic point of view. In this paper, flow-structure characteristics of pneumatic valve is obtained by being optimized based on the proper design criteria. The air with the pressure of 30 bar is the working fluid which is made to fill in the tack in short time. This time is defined as the filling time. On optimum design by considering the flow-structure characteristics, the approach is based on (1) the mathematical formulation of design decisions using the compromise decision-making method, and (2) the approximation technique of response surfaces. The methodology is demonstrated as the multi-objective optimization tool to improve the performance of marine 3/2WAY pneumatic valve.

A Study on The Sign System Following Installation of Screen Doors in Subway Platforms (지하철 승강장 스크린도어 설치에 따른 사인시스템에 관한 연구)

  • Shin, Hong-Jae;Park, Hee-Myeon
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1567-1574
    • /
    • 2006
  • To prevent safety accidents such as injury or death from falling by blocking platforms from trains, the Seoul Metropolitan Subway Corp. have gradually installed screen doors in platforms of 115 subway stations in Seoul on lines 1, 2, 3, and 4. Installation in nine areas among those has been completed and screen doors are being operated as a model operation. Traffic signs should be clear for users. The essential functions of signs should be fully investigated from the aspect of user as well as the visual beauty and recognition. Signs should be able to provide users with information regarding location, position, directions, etc. Particularly, safety and convenient signs should be visually and sensually correlated. However, the entire screen doors in platforms installed in line 2 subway in Seoul are used for commercial advertisement, consequently, the functions and roles as public signs are not fulfilled aggravating inconvenience for users. In this study, cases have been studied to investigate requirements for user-oriented sign system in platform and public sign space to fulfill the functions of sign system in platform. Using an anthropometry approach, the study aimed to obtain the space to install the sign system and to systemize necessary and sufficient conditions for user-oriented system for platform in which screen doors have been installed using. The study suggests fundamental information to obtain the space of public sign system on the entire screen door.

  • PDF

A Study on the Protection Wire Type Decision of Catenary System in the 350km/h High Speed Line (350km/h급 고속전차선로 보호선의 선종결정 기법에 관한 연구)

  • Lee, Hack-Pyo;Seo, Ki-Bum;Park, Jae-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.12
    • /
    • pp.1818-1823
    • /
    • 2015
  • In this paper, we analyzed the optimal configuration of protection wire that have been installed in the electric railway power supply system. Protection wires are to suppress the ground potential rise when the short circuit fault between contact wire-rail(C-F), and protect the electronics equipments(signalling and communication) that are facility the wayside. The role of protection wires must be feed back quickly the fault current to the substation when a short circuit fault occurs. In this paper, we proposed that only one line to install the protection wire. Comparing how to newly proposed and existing system, most of the performance is similar. The reason is that most of the current flowing in the protection wire near the location where the fault occurred. There is no problem even if in one line for human safe and the low impedance of the return circuit in dimension to ensure the safety of the facility during the fault. To ensure safety during an fault occurs, it is sufficient even by one line. But, In the protection wire of facilities planning it is necessary to design taking into account the potential utility.

Characterization of Mechanical Properties in the Heat Affected Zones of Alloy 82/182 Dissimilar Metal Weld Joint (Alloy 82/182 이종금속 용접부 열영향부의 계계적물성치 파악)

  • Kim, Jin-Weon;Kim, Jong-Sung;Lee, Kyoung-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.28-33
    • /
    • 2008
  • This paper presents the characteristics of mechanical properties within the heat affected zones(HAZs) of dissimilar metal weld joint between SA508 Gr.1a and F3l6 stainless steel(SS) with Alloy 82/182 filler metal. Tensile tests were performed using small-size specimens taken from the heat affected regions close to both fusion lines of weld, and the micro-structures were examined using optical microscope(OM) and transmission microscope(TEM). The results showed that significant gradients of the yield stress(YS), ultimate tensile stress(UTS), and elongations were observed within the HAZ of SA508 Gr.1a. This was attributed to the different microstructures within the HAZ developed during the welding process. In the HAZ of F316 SS, however, the welding effect dominated the YS and elongation rather than UTS. TEM micrographs demonstrated these characteristics of the HAZ of F316 SS was associated with a dislocation-induced strain hardening.