• Title/Summary/Keyword: Safety lines

Search Result 556, Processing Time 0.03 seconds

Crane Monitoring System for Moving Objects in Safety Lines (크레인 안전선 접근 이동 물체 감시 시스템)

  • Chong, Ui-Pil
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.12 no.4
    • /
    • pp.237-241
    • /
    • 2011
  • Stable operation of an industry crane becomes more important as current industry facilities become larger and operate at higher speeds. This paper proposes implementing a system for monitoring moving objects within safety lines of an industry crane by camera. The cost of implementing such a system is low, since it requires only a webcam and notebook computer. The detection algorithm of moving objects uses the feature extraction method by image differential histograms. The proposed system is robust to variations in the weather and environment. The area of the inside safety lines is considered and shadow removal algorithm is used for good performance of the system. The system is valuable for practical applications in the industry.

A Study for Computation of Swaying Angle for Jumper Safety Improvement in the Overhead Line (송전선로의 점퍼선 안전성 향상을 위한 횡진각 계산에 관한 연구)

  • 안영주;신춘식;변기식
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.44-50
    • /
    • 1997
  • As jumpers for overhead transmission lines increase In size, it Is necessary to take into the characteristics of jumper swaying space in order to determine jumper reinforcements adequately. From the theory of a structure made of beams, formulas for the sideway swaying of overhead transmission lines due to wind are modeled. And also natural frequency of the vibrated jumper is estimated to check the system resonance. The theoretical results can be led good suggestions to improve the economy and reliability of jumper structure.

  • PDF

Study on the Utilization of HBD in the Conventional Speed-up Lines (일반철도 고속화 구간에서 차축온도검지장치 활용방안에 대한 연구)

  • Choe, Gwon-Hui;Kim, Yu-Ho;Baek, Seung-Mun;Bing, Gun-Seop
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2012.04a
    • /
    • pp.233-243
    • /
    • 2012
  • HBD(Hot Box Detector) is a device to monitor temperature rises to inappropriate lubricant use or mechanical defects. If a train operates without recognizing such an effect, it might result in bearing overheating due to defects and cause a dangerous situation that it could derail a train owing to the damage of axles. Now for the Gyeongbu HSL at 300km/h, the laws related to monitoring overheated axle bearings are notified in the Railway Safety Law and the Railway Construction Law. But in case of the conventional speed-up lines that a train operates at 180 to 230 km/h, the revised bill of relevant standards is ongoing. Therefore in this paper we present references and reviews investigated in order to use the optimal HBD in the conventional speed-up lines.

  • PDF

Analysis of Electromagnetic Field Around Distribution Line (배전선로 주변에서의 전자계 분포 해석)

  • Kwon, Myung-Rak
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.672-676
    • /
    • 2017
  • Electrical energy is playing an increasingly vital role as the primary energy source in everyday life. With the increase in electric power consumption, power facilities are under an increasing stress and must operate at a high capacity. Consequently, the demand for electric power cables in power transmission and distribution lines is rapidly increasing. Underground distribution lines have been steadily replacing the aboveground lines owing to the increase in electric power demand and the need to increase the supply voltage. In addition to line damage, worker safety is of primary concern in this type of underground infrastructure. In this study, to improve the safety of workers dealing with underground transmission lines, we analyzed the electromagnetic field generated around the distribution line and determined the basic criteria for developing a device that can detect a live underground line.

Analysis of Two Electrocution Accidents in Greece that Occurred due to Unexpected Re-energization of Power Lines

  • Baka, Aikaterini D.;Uzunoglu, Nikolaos K.
    • Safety and Health at Work
    • /
    • v.5 no.3
    • /
    • pp.158-160
    • /
    • 2014
  • Investigation and analysis of accidents are critical elements of safety management. The over-riding purpose of an organization in carrying out an accident investigation is to prevent similar accidents, as well as seek a general improvement in the management of health and safety. Hundreds of workers have suffered injuries while installing, maintaining, or servicing machinery and equipment due to sudden re-energization of power lines. This study presents and analyzes two electrical accidents (1 fatal injury and 1 serious injury) that occurred because the power supply was reconnected inadvertently or by mistake.

The Variation of Slope Stability by Ground Water Level in Railway Lines (지하수위에 따른 철도사면의 안정성 변화)

  • Kim, Hyun-Ki;Shin, Min-Ho;Shin, Ji-Soo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.789-795
    • /
    • 2008
  • Slope stability is affected by various factors. For safety management of slopes, monitoring systems have been widely constructed along railway lines. The representative data from the systems are variations of ground profile such like ground water level and pore water pressure etc. and direct displacement measured by ground clinometer and tension wire sensor. Slopes are mainly effected by rainfall and rainfall causes the decrease of factor of safety(FOS). Because FOS varies linearly by the variation of ground water level and pore pressure, it has a weak point that could not define the time and proper warning sign to secure the safety of the train. In this study, alternative of FOS such as reliability index and probability of failure is applied to slope stability analysis introducing the reliability concept. FOS, reliability index, probability of failure and velocity of probability of failure of the slopes by variation of ground water level are investigated for setting up the specification of safety management of slopes. By executing case study of a slope(ILLO-IMSUNGLI), it is showed to be applied to specification of safety management.

  • PDF

Cold Tolerance Characteristic Test of High Yield Tongil-type Rice Breeding Lines for Processing

  • Kang-Su Kwak;Sea-Kwan Oh;Kuk-Hyun Jung;Dae-Ha Seo
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.278-278
    • /
    • 2022
  • Recently, the yield potential of high yield Tongil-type rice varieties has greatly increased, reaching 817kg/10a(Geumgang No.1). Moreover, in order to promote rice consumption and strengthen the competitiveness of the rice processing industry, the R&D of high yield Tongil-type rice varieties for each processing purpose, such as rice noodles, grain feed and industrial materials, has been continuously carried out. However, because Tongil-type rice varieties or lines are generally very vulnerable to cold damage, cold tolerance test can be said to be absolutely necessary to improve the cultivation safety. This study is the result of the seedling and field cold tolerance characteristic tests carried out in 2021 of high yield Tongil-type rice breeding lines. For the cold tolerance characteristic test of seedlings, total 303 high yield rice breeding lines for processing were treated in cold water of 13℃ and irrigation depth of 4cm for 10 days from the third-leaf age, then it was evaluated by comparing the degree of discoloration and withering with the checked varieties(Boramchan, Hanahreum No.2). Also, for the test of field, total 186 high yield rice breeding lines for processing were treated in cold water of 17℃ by keeping pouring day and night from 30 days after transplanting to ripening stage, then it was evaluated by comparing the degree of discoloration, delay of heading, shortening rate of stem length and percent of fertile grain etc. with the checked varieties. And the cold tolerance evaluative criteria were classified as strong(1~3), medium(4~6) and weak(7~9) in overall cold tolerance. (Seedling test) As for the degree of cold tolerance of the check variety, 'Boramchan' and 'Hanahreum No.2' showed a response of 'medium' and 'weak', respectively. However, there was no 'strong' line in the high yield rice breeding lines, 2 lines showed a 'medium' response, and 301 lines showed a 'weak' response. Therefore, except for a few lines(0.7%), most lines(99.3%) showed a 'weak' response. (Field test) In terms of the overall cold tolerance of the check variety, both 'Boramchan' and 'Hanahreum No.2' showed a 'medium' response. Similarly, there was no 'strong' line in the case of high yield rice breeding lines, 20 lines showed a 'medium' response, and 166 lines showed a 'weak' response. Therefore, except for some(10.8%) lines, most(89.2%) lines showed a 'weak' response. From the above results, we selected about 100 individuals with less seed shattering and degeneration of the ear tip, and with a relatively high percent of fertile grain, and are continuing to select lines with improved cold tolerance in the F4~F5 group in this year. As such, most of the Tongil-type rice varieties have poor cold tolerance and thus have low cultivation safety at low temperatures. However, it is important to select improved lines through generational progress because there are some lines that still have a certain level of cold tolerance among them.

  • PDF

Development and Case of Manipulator Robot for Live-Working on Distribution Lines (배전선로 무정전 활선작업용 Manipulator 개발현황 및 사례)

  • Kim, Jae-Hoon;Kim, Seung-Ho;Kim, Chang-Hoi;Lee, Heung-Ho;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2005.05b
    • /
    • pp.45-50
    • /
    • 2005
  • Nowadays, economical and social environments are changing to the type of an advanced country for development of techniques in power industry. So most of workers are recently avoiding the 3D works and asking for safety of working environment, etc. in highly dangerous parts such as hot line working on distribution lines, especially. Therefore, most advanced countries are using the support-arm or robotic systems on distribution line works for securing the construction reliability, economical feasibility and protection of linemen from the electric shock and so forth. In special Japanese electric power companies are using the robotic system named manipulator. In Korea, a support-arm has been developed for safety and facility in live working on distribution lines but not widely supplied. In this paper we will introduce development cases of support arm and manipulator robot for live working on distribution lines.

  • PDF