• Title/Summary/Keyword: Safety evaluation test

Search Result 1,731, Processing Time 0.029 seconds

Fatigue Safety Evaluation of the Half-Depth Precast Deck with RC Rib Panel (리브 형상을 갖는 반단면 프리캐스트 바닥판의 피로 안전성 평가)

  • Hwang, Hoon Hee
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.103-110
    • /
    • 2019
  • In order to reduce the accidents occurring at construction sites, it is necessary to approach with harmonious measures considering various aspects such as systems, training, facilities, and protection equipments. Suggestion of safe construction method can be a good alternative. In the previous study, the half-depth precast deck with RC rib panel was proposed as an alternative method for safe bridge deck construction, and the performance required by the design code was verified through a four-point bending test. But the actual bridge deck is subjected to the repetitive action of the wheel load rather than the bending condition due to the four-point load. In this study, fatigue test was performed by repeating the wheel load $2{\times}10^6$ cycles to verify the safety of the half-depth precast deck with RC rib panel under actual conditions. As a result, fatigue effect due to repetition of wheel load was not significant in terms of serviceability such as crack width and deflection. In the residual strength test conducted after the fatigue test, the half-depth precast deck with RC rib panel failed by punching shear which is typical failure mode of bridge decks and the residual strength was similar to the punching strength of the RC and PSC bridge decks in spite of the fatigue effects.

The Investigation for Detection of Crack Initiation in the CFRP Laminates under Flexural Loading Test (굽힘하중에서 탄소섬유 복합적층재의 균열 발생 측정에 관한 연구)

  • Lee, Jun Hyuk;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.7-13
    • /
    • 2022
  • Digital image correlation (DIC) is a method used to measure the displacement and strain of structures. It involves transforming and analyzing images before and after deformation using correlation coefficients from irregular light and shade on the surface of structures. In the present study, a microspeckle pattern was applied to the surface of a specimen to identify initial cracking. The test specimen constituted CFRP composites laminated on a curved Al liner The specimen was manufactured by stacking 100 ply of CFRP prepregs in the 0° and 90° directions in a three-point bending test. The equivalent strain was evaluated through DIC analysis after monitoring deformation using a CCD camera. Fracture shape was observed using a microscope. The equivalent strain contour distribution was checked until the maximum load fracture occurred at the center of the test specimen. Variations in the strain indicated the initial occurrence and progression of microcracks. These results can be used to improve the accuracy of detecting micro crack initiation and to achieve structural stability.

Evaluation of Genotoxicity of SU-Eohyeol Pharmacopuncture Using an In Vitro Chromosome Aberration Test in Chinese Hamster Lung Cell

  • Ku, Jaseung;Hwang, Ji Hye
    • Journal of Pharmacopuncture
    • /
    • v.25 no.3
    • /
    • pp.290-300
    • /
    • 2022
  • Objectives: This study was conducted to evaluate the safety of SU-Eohyeol pharmacopuncture (SUEP) by assessing its potential to cause chromosomal abnormalities in Chinese hamster lung cells (CHL/IC). Methods: A dose-curve was conducted to determine the highest dose of SUEP. Doses of 10, 5, 2.5, 1.25, 0.625, and 0.313% were used, and no cytotoxicity or SUEP precipitation was observed. SUEP doses of 10, 5, and 2.5%, with positive and negative controls, were used in a chromosome aberration test. Results: In this study, the frequency of abnormal chromosomal cells in the SUEP group did not show a statistically significant difference from that of the negative control group in short-term treatments with and without metabolic activation and the continuous treatment without metabolic activation. Compared with the negative control group, the positive control group had a significantly higher frequency of cells with structural chromosomal abnormalities. This test's results satisfied all conditions for determining the results. Conclusion: SUEP did not induce chromosomal aberrations under the conditions of this study. Other toxicity evaluations, safety studies in humans, and various clinical trials are required to evaluate the safety and efficacy of SUEP.

Connection Structure Between Center Pillar and Roof Center Rail (거셋일체형 센터필러 어퍼 루프레일 연결구조 개발)

  • Lee, Hae Hoon;Chung, Pil Sang;Kang, Chong Ku
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.4
    • /
    • pp.26-32
    • /
    • 2021
  • This study is intended to augment the Roof strength test being evaluated by IIHS (Insurance Institute for Highway Safety). In order to find solutions for increasing Roof Crashworthiness Evaluation SWR (Strengthto-weight ratio). This study introduces that Integrated Connection Structure Between Center Pillar and Roof Center Rail is proposed as a critical solution.

Evaluation of Structural Test for Bottom End Piece Used for Nuclear Power Reactor (원자로용 하단고정체에 대한 구조시험 평가)

  • 김재훈;사정우;김덕회;손동성;임정식
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.3-11
    • /
    • 1999
  • The atomic fuel rods between top and bottom end pieces of reactor need to be extended for high combustion rate of future-type fuel to increase the irradiation in the axial direction. For allowing axial extension of the fuel rods, the space between top and bottom end pieces should be expanded. Thus the thickness reduction of the flow plate is necessary. This study was carried out the mechanical strength test by using strain gages as a function of flow plate thickness, the existence of skirt and loading condition for the Korean Fuel Assembly(KOFA). The experimental apparatus was designed for load conditions, uniformly distributed load and displacement. Test method using whiffle tree of uniformly distributed load has been comparatively conservative. The test results were compared with those of finite element analysis and the test method on bottom end piece was established.

  • PDF

Structure Analysis and Loading Test of Bogie Frame (대차틀의 구조해석 및 하중시험에 관한 연구)

  • Yoon Sung-Chol;Park Sung-Hyuk;Lee Kang-won;Kim Won-kyung;Hong Yung-Ki
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.199-205
    • /
    • 2004
  • This paper describes the result of structure analysis and load test of bogie frame. The purpose of the analysis and test is to evaluate an safety which bogie frame shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Bogie system consist of bogie frame, suspensions, wheel-sets, brake system and transmission system. Among these component, the bogie frame is most significant component subjected to the vehicle and passenger loads. The evaluation method is used the JIS E 4207 specification throughout the FEM analysis and static load test. The test results have been very safety and stable for design load conditions.

  • PDF

A Study on Electromagnetic Emission of HEV's Gasoline and Electric Mode (HEV 차량내 내연기관과 전기모터 모드의 전자파 방사에 대한 고찰)

  • Kim, Sungbum;Woo, Hyungu
    • Journal of Auto-vehicle Safety Association
    • /
    • v.10 no.1
    • /
    • pp.12-19
    • /
    • 2018
  • This paper deals with the broadband electromagnetic emission test of a hybrid electric vehicle. The hybrid electric vehicle's powertrain system consists of an internal combustion engine and an EV traction motor. Depending on the SOC of the traction battery, these modes change automatically in the running state. The Korea electromagnetic compatibility regulations of KMVSS and UN WP.29 stipulated the evaluation method of hybrid electric vehicles. This study analyzes and compares two test results: internal combustion and electric motor mode. Some problems of test conditions are described and an improved test method is proposed for measuring broadband emissions of a hybrid electric vehicle. As a result, we expect this paper to be used as a consideration for improvement when test specifications are revised in the future.

A study on advanced EMU's maintenance program on test operation in Dabul line (차세대 전동차 대불선 시운전 시 유지보수방안 연구)

  • Kim, Young-Kyu;Park, Se-Young;Song, Jeong-Hun;An, Cheon-Heon;Lee, Han-Min
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.2215-2222
    • /
    • 2010
  • Advanced EMU have been enhanced in terms of safe transport and maintainability. It is a new urban railway technology that enables an operation institution to cut repair and maintenance costs and customers to use convenient service at lower costs based on IT technology. If a development vehicle of Advanced EMU is completed, it will be used to test the entire advanced EMU system through sufficient performance check and reliability check prior to operation in commercial line. It will also verify efficiency, safety, punctuality and energy efficiency of transport. Accordingly, it is necessary to figure how to repair and maintain vehicles to enhance safety of Advanced EMU system in cooperation with operation during the period of comprehensive evaluation on the operation of a development vehicle in a test line. In this paper, we investigated the maintenance program of Advanced EMU on test operation in Dabul line. The test condition and operation environment of Advanced EMU in Daebul line was analyzed.

  • PDF

Structure Analysis and Loading Test of Torque arm for Driving Gear Unit of Unique Model (독자모델 감속구동장치 토크암의 구조해석 및 하중시험에 관한 연구)

  • Cha Soo-Deok;Choi Jin-Wook;Yu Jai-Il;Lee Min-Soo
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.211-215
    • /
    • 2004
  • This paper describes the result of structure analysis and load test of torque arm for driving gear unit. The purpose of the analysis and test is to evaluate an safety which torque arm shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Driving gear unit consist of gearbox and torque arm. Both components, torque arm is significant component subjected to the vehicle and motor loads. The evaluation methode is used the FEM analysis, static and fatigue test. The test results have been very safety and stable for design load conditions.

  • PDF

A safety evaluation on the loading test of EMU′s carbody having stainless and aluminum (도시철도차량의 스테인리스와 알루미늄 구조체 하중시험에 대한 안전성평가)

  • 정종덕;김원경;홍용기;윤성철;이장욱
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.156-161
    • /
    • 2002
  • This paper describes the result of carbody load test. The purpose of the test is to evaluate an safety which carbody structure shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load and operating condition. Carbody material applied a stainless steel and an aluminum alloy, The stainless steel model is the carbody of a motor car which is delivering to KNR line 1 in 2002 and the aluminum alloy model is the carbody of a motor car which is delivering to GWANGJU line 1 in 2003. This strength test is based on "performance test standard for Electrical Multiple Unit, noticed by Ministry of Construction & Transportation, in 2000" and reference code is UIC 566 and JIS E 7105.

  • PDF