• Title/Summary/Keyword: Safety distance

검색결과 1,579건 처리시간 0.024초

자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발 (Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement)

  • 김재진;전정채
    • 전기학회논문지
    • /
    • 제65권10호
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.

Fatigue Measurement by Lifting Index

  • Kim Dae-Sik;Kang Kyong Sik
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2000년도 추계학술발표논문집
    • /
    • pp.187-193
    • /
    • 2000
  • The purpose of this study was to reduce the chronical low back pain for the manual material handlers. The objectives of this study was to: (1) examine lifting variables, (2) analyze collected data, and (3) suggest lifting redesign recommendations in workplace. The data were collected in A company, manufactures various paints in Si-Wha industrial complex, Kyunggi-Do. It was found that Sb(horizontal distance), Sc(vertical distance), 54(travelling distance) and Sf(frequency) were significant at the 0.01 level and Sa(weight) was significant at the 0.05 level.

  • PDF

접지 그리드에서의 보조전극 배치에 따른 접지임피던스 측정 및 분석 (Measurement and Analysis of Ground Impedance according to Arrangement of Auxiliary Probe around Ground Grid)

  • 길형준;송길목;김영석;김종민
    • 한국안전학회지
    • /
    • 제30권4호
    • /
    • pp.46-50
    • /
    • 2015
  • This paper describes the measurement and analysis of ground impedance according to arrangement of auxiliary probe around ground grid using the fall-of-potential method and the testing techniques to minimize the measuring errors are proposed. The fall-of-potential method involves passing a current between a ground electrode and a current probe, and then measuring the voltage between a ground electrode and a potential probe. To minimize interelectrode influences due to mutual resistances, the current probe is a generally placed at a substantial distance from the ground electrode under test. In order to analyze the effects of ground impedance due to the arrangement of auxiliary probe and frequency, ground impedances were measured in case that the arrangements of auxiliary probe were straight line, perpendicular line, and horizontal line. The distance of current probe was located from 10[m] to 200[m] and the measuring frequency was ranged from 55[Hz] to 513[Hz]. As a consequence, the ground impedance increases with increasing the distance from the ground electrode to the point to be tested, but the ground impedance decreases with increasing the frequency.

LPG 판매업소의 위험성 제어계획 (Planning for Safety Control on LPG Distribution Depot)

  • 노삼규;전성우;강태희;서영민
    • 한국화재소방학회논문지
    • /
    • 제12권4호
    • /
    • pp.21-30
    • /
    • 1998
  • LPG 판매업소의 용기보관창고는 보관량이나 위해 상황을 충분히 고려하지 않은 상태로 단순히 방폭벽 구조에 의한 안전규제에 의존해 왔다 따라서 LPG폭발로 인한 보관창고 의 안전규정은 안전완충거리를 충분히 확보하고 있는지 확인할 필요가 있다. 기존의 안전 규제는 그러한 보관창고로부터 사고시 인근에 위치한 구조물과 연간 활동에 미치는 잠재 적 초과압력이나 방출열의 정도를 고려하고 있는지 그 확인이 요구된다. 본 연구는 P PHAST와 IAEA의 위험성 평가와 우선 순위 선정수법, 일본의 LPG 판매소 안전규정 등 을 통하여 안전거리를 산출하였다. 이 결과에 의하면 기존의 LPG판매소의 방폭벽은 추가 적인 안전거리가 요구된다.

  • PDF

화학사고 초기대응 소방대 보호를 위한 독성농도(T-LOC) 끝점거리 연구 (Toxic Concentration(T-LOC) Endpoint Distance Study for Fire Brigade Protection in Response to Chemical Accidents)

  • 윤종찬;조철희;원정훈
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.60-71
    • /
    • 2023
  • The purpose of this study is to propose a quantitative toxicity endpoint distance suitable for the initial response of firefighters by comparing and analyzing the commonly applied toxic level of concern (T-LOC), specifically emergency response planning guidelines (ERPG), acute exposure guideline levels (AEGL), and immediately dangerous to life or health (IDLH). This is to protect the fire brigade, which responds to toxic chemical accidents first during the golden time. Using areal locations of hazardous atmospheres, a damage prediction program, the amount of leakage for both acidic and basic substances, along with the endpoint distance, were analyzed for alternative accident and worst-case accident scenarios. The results showed that the toxicity endpoint distance, serving as a compromise between Level-3 and Level-2 of T-LOC, was longer than ERPG-3 and shorter than ERPG-2 with IDLH, while its values were analyzed in the order of ERPG-2, AEGL-2, IDLH, AEGL-3, and ERPG-3. It is suggested that the application of IDLH in an emergency (red card) and ERPG-2 endpoint distance in a non-emergency (non-red card) can be utilized for the initial response of the fire brigade.

지상 고압 천연가스 배관의 최소 이격거리 기준에 관한 연구 (A Study on Minimum Separation Distance for Aboveground High-pressure Natural Gas Pipelines)

  • 이진한;조영도
    • Korean Chemical Engineering Research
    • /
    • 제57권2호
    • /
    • pp.225-231
    • /
    • 2019
  • 우리나라의 경우 지상에 설치된 고압 천연가스 배관과 건축물 간의 최소 이격거리는 가스기술기준(KGS code)에 의해 규제된다. 이 논문을 통해 이러한 최소 이격거리를 관련된 KGS 코드를 개정한 기술적 근거를 보여주고자 한다. 이격거리를 설정하는 접근 방법으로 합리적 사고 시나리오에 의한 피해기반 접근법을 적용하였는데 배관에 부착된 1인치 분기 라인이 파손되어 제트화재가 발생한 시나리오를 선정하였다. 여기서 공업지역에 종사하는 작업자에 대해 비공업지역에 있는 사람들보다 더 높은 허용가능 복사열 플럭스를 적용하였다. 그 이유는 공업지역에 종사하는 근로자는 일반 대중들 보다 더 짧은 시간 안에 비상 대피가 가능하기 때문이다. 이 사고 시나리오에 대한 피해영향 분석 결과로부터 지상에 설치된 고압 천연가스 배관과 건축물 간의 최소 이격거리로서 비공업지역에서는 30 m, 공업지역에서는 15 m로 KGS 코드 개정을 제안하였다. 코드 개정안은 KGS 코드 위원회(가스기술기준위원회)에 채택되어 현재 시행 중이다.

선박운항자 안전 의식에 기초한 선박통항 최소 이격거리에 관한 연구 (A Study on the Minimum Safety Distance between Navigation Vessels based on Vessel Operator's Safety Consciousness)

  • 박영수;정재용;김종성
    • 해양환경안전학회지
    • /
    • 제16권4호
    • /
    • pp.401-406
    • /
    • 2010
  • 해상에서의 선박운항자는 선박을 운항 중 장애물 혹은 타선에 대하여 적정한 이격거리를 두고 항행하고 있다. 다시 말해 시정 상태, 풍속, 조류 등에 따라 선박 전 후 거리, 좌 우현 정횡거리를 주관적인 안전 의식에 근거하여 이격하여 통항하고 있다. 현재 우리나라에서는 통항 선박 간 최소 안전이격거리 개념을 1980년대 초 외국에서 조사된 자료로 사용하고 있고, 항계 내(제한수로)와 항계 밖의 통항 선박의 안전거리가 상이함에도 불구하고 구분 없이 사용되고 있다. 또한 선박 조종학적 안전거리는 선박 전후 거리보다는 선박 측면거리가 중심이며, 선박 종류에 따라 최소 안전이격거리가 상이하지만 고려되고 있지 않은 실정이다. 따라서 이 논문에서는 상황에 따른 선박운항자의 안전 의식을 고려한 적정 이격거리를 정량화하여 해상교통안전성 평가모델의 충돌 판정 영역 개발을 위한 기초 자료로 활용하고자 하고, 우리나라에 적합한 해상교통 혼잡도 모델 개발 및 상황 선박별 해상교통관제에 필요한 가이드라인으로 이용할 수 있는 기초자료를 제공하는 데 목적이 있다. 연구결과, 시정이 양호한 주간의 경우 선수전방 4.4 L, 선미후방 3.1 L, 정횡 2.6L로 기존에 사용되고 있는 최소 안전이격거리와는 차이가 있는 것으로 분석되었으며 시정 및 주야간 등과 같은 파라미터를 다양하게 고려하였다.

LP 가스 배관의 누출부로부터 점화가능 거리에 관한 연구 (A Study on the Ignition Distance from a Leakage Point of the LP Gas Pipe)

  • 류영돈;김영구;조영도
    • 한국가스학회지
    • /
    • 제21권5호
    • /
    • pp.70-76
    • /
    • 2017
  • "도시가스사업법" 및 "액화석유가스의 안전관리 및 사업법" 관련 기준(KGS Code)에서는 가스배관의 이음부(용접이음매 제외)와 전기설비(전기개폐기, 전기계량기, 전기접속기, 전기점멸기 등)와의 이격거리를 규정하고 있다. "전기설비기술기준"에서도 가스관련 법령과 부합되게 전기설비와 가스배관의 이음부와의 이격거리를 규정하고 있다. "도시가스사업법" 관련 기준의 경우 공급시설 기준과 사용시설 기준에서 규정하는 이격거리가 상이하다. 본 연구에서는 LP가스가 배관의 이음부에서 누출되는 경우 점화 가능 거리를 실증 실험하고, 현재 가스 관련 기준에서 규정하고 있는 전기설비와 가스설비와의 이격거리 기준의 적정성에 대해 검토하였다. 실험 결과 배관의 이음부에서 가스가 누출되는 경우 기준에서 규정하고 있는 30cm 이상의 거리에서도 점화가 가능함을 확인하였다. 따라서, 현재 "도시가스사업법" 및 "액화석유가스의 안전관리 및 사업법" 관련 기준에서 규정하고 있는 가스배관과 전기설비와의 이격거리 기준이 적절한 것으로 판단되었다.