• Title/Summary/Keyword: Safety assurance

Search Result 377, Processing Time 0.029 seconds

A study on the Evaluation of Real-Time Map Update Technology for Automated Driving (자율주행 지원을 위한 정밀도로지도 갱신기술 평가를 위한 기준 도출 연구)

  • PARK, Yu-Kyung;KANG, Won-Pyung;CHOI, Ji-Eun;KIM, Byung-Ju
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.22 no.3
    • /
    • pp.146-154
    • /
    • 2019
  • Recently, a system has been developed and applied to establish and utilize HD maps through R&D. The biggest problem, however, is the lack of a proper HD map update system, which requires the development and adoption of such a system as soon as possible. In addition, in the case of updating HD maps for automated driving, integrity and accuracy of maps are required for safe driving, so an test of these technologies and data quality is required. In April 2018, the Ministry of Land, Infrastructure and Transport implemented a project to 'Develop Technology to Demonstrate and Share the Instant Road Change Detection and Update Technology for automated driving. This paper analyzed the technology for updating map based on the investigation and analysis of relevant technology trends for the development of integrated demonstration and sharing technology of road change rapid detection and updating map technology, and put forward the criteria for road change rapid detection, integrated quality verification of update technology. It is expected that the results of this study will contribute to quality assurance of HD maps that support safety driving for automated vehicles.

A Study on the Evaluation for Performance of Body Armor Vest using ANOVA (분산분석을 이용한 방탄조끼의 방탄성능 평가에 관한 연구)

  • Park, Jae Woo;Byun, Kisik;Cho, Sung-Yong;Kim, Suk Ki;Yeo, Yongheon;Kwon, Jae Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.372-378
    • /
    • 2021
  • A body armor vest is a form of munition related directly to the safety and life of combatants. Therefore, it must meet the requirements for ballistic resistance. The ROK demands the performance of body armor vest meet the Level IIIA specified by the NIJ STD-0101.06 published by the US National Institute of Justice. This study performed acceptance tests on body armor vests. The factors for evaluating the ballistic resistance evaluated were not only whether it penetrates when shooting but also whether the BFS (Backface Signature) depth does not exceed 44 mm when it does not penetrate. The factors were assessed to determine if they were consistent or not. The BFS depth is affected by various test factors, such as the physical properties of the backing material and the changes in the amount of impact with the bullet velocity. In this study, an analysis of the bulletproof performance was performed by extracting the data with the same conditions using ANOVA to remove the influence of these external factors. The analysis revealed a correlation between the BFS depth, bullet velocity, vest conditions, and protection area. The mass production process was analyzed by estimating the Interval of BFS on each lot. Through this, a new methodology for ballistic resistance evaluation and paradigm for future quality assurance is suggested.

Measurement uncertainty analysis of radiophotoluminescent glass dosimeter reader system based on GD-352M for estimation of protection quantity

  • Kim, Jae Seok;Park, Byeong Ryong;Yoo, Jaeryong;Ha, Wi-Ho;Jang, Seongjae;Jang, Won Il;Cho, Gyu Seok;Kim, Hyun;Chang, Insu;Kim, Yong Kyun
    • Nuclear Engineering and Technology
    • /
    • v.54 no.2
    • /
    • pp.479-485
    • /
    • 2022
  • At the Korea Institute of Radiological and Medical Sciences, physical human phantoms were developed to evaluate various radiation protection quantities, based on the mesh-type reference computational phantoms of the International Commission on Radiological Protection. The physical human phantoms were fabricated such that a radiophotoluminescent glass dosimeter (RPLGD) with a Tin filter, namely GD-352M, could be inserted into them. A Tin filter is used to eliminate the overestimated signals in low-energy photons below 100 keV. The measurement uncertainty of the RPLGD reader system based on GD-352M should be analyzed for obtaining reliable protection quantities before using it for practical applications. Generally, the measurement uncertainty of RPLGD systems without Tin filters is analyzed for quality assurance of radiotherapy units using a high-energy photon beam. However, in this study, the measurement uncertainty of GD-352M was analyzed for evaluating the protection quantities. The measurement uncertainty factors in the RPLGD include the reference irradiation, regression curve, reproducibility, uniformity, energy dependence, and angular dependence, as described by the International Organization for Standardization (ISO). These factors were calculated using the Guide to the Expression of Uncertainty in Measurement method, applying ISO/ASTM standards 51261(2013), 51707(2015), and SS-ISO 22127(2019). The measurement uncertainties of the RPLGD reader system with a coverage factor of k = 2 were calculated to be 9.26% from 0.005 to 1 Gy and 8.16% from 1 to 10 Gy. A blind test was conducted to validate the RPLGD reader system, which demonstrated that the readout doses included blind doses of 0.1, 1, 2, and 5 Gy. Overall, the En values were considered satisfactory.

Assessing the Quality for Blood Transfusion Service since the 1st National Quality Assessment Program in South Korea (국내 1차 수혈 적정성 평가 시행에 따른 수혈서비스 질관리 현황)

  • Jin-Ah Kwon;Eun-Jeong Cho;A-Hyun Jung;Dong-Sook Kim
    • Quality Improvement in Health Care
    • /
    • v.28 no.2
    • /
    • pp.30-38
    • /
    • 2022
  • Purpose: The Health Insurance Review and Assessment Service (HIRA) in South Korea initiated a quality assessment (QA) program for blood transfusion healthcare services in 2020 to ensure patient safety and appropriate blood use. This study examines the quality of blood transfusion services since the first national QA program for blood transfusion services in Korea. Methods: We analyzed HIRA claims and QA investigation data based on inpatient medical records from all tertiary, general, and primary hospitals between October 2020 and March 2021. The target population was patients aged 18 years and older who received either total knee arthroplasty or red blood cell transfusion. The QA indicators for transfusion healthcare service consisted of four quality indicators and four monitoring indicators. Results: We analyzed the results of QA indicators for transfusion service from the medical records of 189,668 patients from 1,171hospitals and expressed indicators as proportions. The average results for evaluation indicators were as follows: transfusion checklist presence, 64.8%; irregular antibody tests, 61.8%; transfusions in which the hemoglobin levels before transfusion met the transfusion guidelines for patients undergoing total knee arthroplasty, 20.6%, and transfusions in patients undergoing total knee arthroplasty, 59.3%. The average results for monitoring indicators were as follows: transfusion management implementation in medical institutions, 56.9%; preoperative anemia management in anemia patients undergoing total knee arthroplasty, 43.9%; one-unit transfusions, 82.5%; and the transfusion index. Conclusion: The quality of blood transfusion healthcare varied and the assessment revealed that there is scope for improvement. Hospitals require more effective blood transfusion management and this can be facilitated by providing feedback on the QA results about blood transfusion healthcare services to medical institutions, and by disclosing the results to the public.

Proposal of a Fail-Safe Requirement Analysis Procedure to Identify Critical Common Causes an Aircraft System (항공기 시스템의 치명적인 공통 요인을 식별하기 위한 고장-안전 요구분석 절차 제안)

  • Lim, San-Ha;Lee, Seon-ah;Jun, Yong-Kee
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.4
    • /
    • pp.259-267
    • /
    • 2022
  • The existing method of deriving the fail-safe design requirements for the domestic developed rotary-wing aircraft system may miss the factors that cause critical system function failures, when being applied to the latest integrated avionics system. It is because the existing method analyzes the severity effect of the failures caused by a single item. To solve the issue, we present a systematic analysis procedure for deriving fail-safe design requirements of system architecture by utilizing functional hazard assessment and development assurance level analysis of SAE ARP4754A, international standard for complex system development. To demonstrate that our proposed procedure can be a solution for the aforementioned issue, we set up experimental environments that include common factors that can cause critical function failures of a system, and we conducted a cross-validation with the existing method. As a result, we showed that the proposed procedure can identify the potential critical common factors that the existing method have missed, and that the proposed procedure can derive fail-safe design requirements to control the common factors.

External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities (고체팬텀을 이용한 국내 방사선 치료시설의 흡수선량에 대한 조사)

  • Choi, Chang-Heon;Kim, Jung-In;Park, Jong-Min;Park, Yang-Kyun;Cho, Kun-Woo;Cho, Woon-Kap;Lim, Chun-Il;Ye, Sung-Joon
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.50-56
    • /
    • 2010
  • Purpose: We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. Materials and Methods: In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party’s American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. Results: Most of the beams (74%) were within ${\pm}2%$ of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance (${\pm}3%$), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be ${\pm}1.5%$. Conclusion: The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.

A Quality Assurance Study for the Application of Cook/chill System in School Foodservice Operation (I) - Broiled Spanish Mackerel - (학교급식에 Cook/chill system 적용을 위한 품질보증연구(I) - 삼치구이 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.3
    • /
    • pp.278-293
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point-based standardized recipe applicable to cook/chilled Broiled Spanish Mackerel in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. HACCP for the production of menu items was identified in simulation study. At each critical control point, time-temperature profile was recorded and microbiological analysis was done. Also chemical analyses and sensory evaluation were conducted for 5 days of chilled storage. The results of time-temperature measurement of Broiled Spanish Mackerel by each production phase showed satisfactory condition that met the standards. Broiled Spanish Mackerel showed excellent microbiological quality from raw ingredient phase ($TPC:2.58{\pm}0.12\;Log\;CFU/g$) to holding phase ($TPC:2.70{\pm}0.42\;Log\;CFU/g$). Coliform (0.84 Log MPN/g) and fecal coliform (0.84 Log MPN/g) were detected from marinating phase ($TPC:3.82{\pm}0.52\;Log\;CFU/g$). After heating, only few mesophiles were detected ($TPC:1.83{\pm}0.49\;Log\;CFU/g$). No psychrophiles, coliforms and fecal coliforms were detected. In the phases after rapid chilling, during chilled storage and after reheating and distribution, almost none of the above microbes were detected. Salmonella and Listeria monocytogenes were not detected in all production phases. The pH immediately after cooking was 6.65 and then increased significantly to 6.81 on the third day of chilled storage (p<0.001). Acid value did not show significant changes while total volatile based nitrogen (TVBN) dramatitically increased during storage periods (p<0.01). In the result of sensory evaluation, general acceptability points had been rated high in the first day of storage, and then, the points were decreased significantly on the third day (p<0.05). General acceptability points ranged from 8.86 to 10.68. Accordingly, Broiled Spanish Mackerel is highly recommendable cook/chill system. Considering the DHSS standards for storage, the ideal shelf-life recommended for Broiled Spanish Mackerel is within 4 days excluding cooking day. For Broiled Spanish Mackerel, critical control points were purchasing and receiving of frozen Spanish Mackerel, heating, chilling, chilled storage, reheating and distribution.

  • PDF

History of Guard System during the Period of Military Rule in the Goryeo Dynasty (고려 무신집권기 호위제도의 경호학적 고찰)

  • Lee, Sung-Jin;Cho, Sung-Jin
    • Korean Security Journal
    • /
    • no.34
    • /
    • pp.233-258
    • /
    • 2013
  • In the early days of the Goryeo Dynasty, the royal guard was comprised of the central regular army in the 2-gun-6-wi system, and Nasungeomgun was in charge of the security inside the palace. However, the military system became disorganized during the period of military rule and the royal guard had to rely on military subjects. The military officials suppressed the civil ministers centering on Jungbang, the guarding organization close to the King to incapacitate the royal authority and control the state affairs. When the rule of the three leaders of the military rule became short-lived and Dae-seung Gyeong is raised to the ruler, he organized a do-or-die squad comprised of a hundred and more people for his personal safety, and this became the first dobang. Dobang was disassembled after Dae-seung Gyeong died of disease, but under the rule of Chung-heon Choe, Dae-seung Gyeong's dobang was revived and reinforced into 'Yukbeon Dobang' to provide the ruler with personal protection and intensify the ruling system, and it was quite a large organization with more refined system. Yukbeon Dobang was expanded and reinforced into Naeoedobang under the rule of Woo Choe, the son of Chung-heon Choe, and it was enhanced even more into Dobang Samsipyukbeon System under the rule of the grandson, Hang Choe. Dobang can be considered as the guard organization in modern sense, and it collected information and surveyed the area where guarding is required and house troops that belonged to Naedobang eliminated the risks that may follow afterwards to make assurance doubly sure for guarding. The Choe's regime established Mabyeolcho as a private guard organization in addition to dobang, and this formed the cavalry and infantry units with dobang. Yabyeolcho organized by Woo Choe in the reign of King Gojong was divided into Joabyeolcho and Ubyeolcho, and later Sineuigun was integrated with them to form Sambyeolcho. Originally, Yabyeolcho was established under the rule of Woo Choe to prevent crime in the evening, but after Sineuigun was organized with the ones who were captured by Mongolian army but escaped, in other words when Sambyeolcho was organized, the organization displayed much broader influence by covering military and police affairs as well as punishment and imprisonment. The guarding organization during the Period of Military Rule in the Goryeo Dynasty did not have strict distinction between official guard and personal guard. The private guard in modern days which is the equivalent of personal guard is characterized by its commerciality, however, house troops and the members of dobang did not seem to pursued profit. The guard organization during the period of military rule started from dobang which was organized for personal safety but gradually developed publicness through the participation of civil ministers and expansion, and later it played the pivotal role for social security serving official purpose up to the level where the distinction between official and private activities was blurred during the period of Sambyeolcho.

  • PDF

A Quality Assurance Study for the Application of Cook/Chill System in School Foodservice Operation (II) - Pork Bulgogi (Broiled Sliced Pork with Sauces) - (학교급식에 Cook/Chill System 적용을 위한 품질보증연구(II) - 돼지불고기 -)

  • Kwak, Tong-Kyung;Moon, Hye-Kyung;Park, Hye-Won;Hong, Wan-Soo;Ryu, Kyung;Chang, Hye-Ja;Kim, Sung-Hee;Choi, Eun-Jung
    • Journal of Food Hygiene and Safety
    • /
    • v.13 no.4
    • /
    • pp.319-331
    • /
    • 1998
  • The purposes of this study were to develop Hazard Analysis Critical Control Point plan applicable to cook/chilled Pork Bulkogi (broiled sliced pork with sauces) in school foodservice operations and to establish reasonable shelf-life limits by assessing food quality during chilled storage period of 5 days. During the product flow, time-temperature profile was recorded and microbiological analyses including mesophilic and psychrotrophic total plate counts, coliform, and fecal coliform and qualitative analyses of Salmonella and Listeria monocytogenes were done. Chemical analyses (pH, acid value, total volatile basic nitrogen), sensory evaluation, and quantitative analysis of thiamin were conducted for 5 days of chilled storage. The number of mesophiles in raw pork ($4.26{\pm}0.11\;Log\;CFU/g$), seasoning mixture ($5.97{\pm}O.04\;Log\;CFU/g$) and marinated pork ($5.56{\pm}0.21\;Log\;CFU/g$) were below the microbial standards for "requires further cooking" food items. Listeria monocytogenes was detected in seasoning mixture. After heating, the number of mesophiles ($5.17{\pm}0.04\;Log\;CFU/g$) were slightly reduced but it did not meet the microbial guidelines of $5\;Log\;CFU/g$ for "ready-to-eat" foods. No other microbes including pathogens were detected. By reheating the menu item after chilled storage, the number of mesophiles were reduced in every phase of 1st day ($4.62{\pm}0.22\;Log\;CFU/g$), 3rd day ($4.55{\pm}0.20\;Log\;CFU/g$) and 5th day ($4.25{\pm}0.16\;Log\;CFU/g$) of chilled storage, and the number of microbes was below the standard limits for "ready-to-eat" foods. At the fifth day of chilled storage, pH (p<0.05), acid value (p<0.01) and TVBN (p<0.05) showed significant increases. Sensory evaluation results did not show any significant change for 5 days of chilled storage. Thiamin content showed a decrease for 5 days of chilled storage. Consequently, the ideal shelflife recommended for Pork Bulkogi was within 3 days of chilled storage. CCPs for Pork Bulkogi were purchasing and receiving of raw meat and some seasoning ingredients, heating, chilling, chilled storage, reheating, and distribution.

  • PDF

토양 및 지하수 Investigation 과 Remediation에 대한 현장적용

  • Wallner, Heinz
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.44-63
    • /
    • 2000
  • Situated close to Heathrow Airport, and adjacent to the M4 and M25 Motorways, the site at Axis Park is considered a prime location for business in the UK. In consequnce two of the UK's major property development companies, MEPC and Redrew Homes sought the expertise of Intergeo to remediate the contaminated former industrial site prior to its development. Industrial use of the twenty-six hectare site, started in 1936, when Hawker Aircraft commence aircraft manufacture. In 1963 the Firestone Tyre and Rubber Company purchased part of the site. Ford commenced vehicle production at the site in the mid-1970's and production was continued by Iveco Ford from 1986 to the plant's decommissioning in 1997. Geologically the site is underlain by sand and gravel, deposited in prehistory by the River Thames, with London Clay at around 6m depth. The level of groundwater fluctuates seasonally at around 2.5m depth, moving slowly southwest towards local streams and watercourses. A phased investigation of the site was undertaken, which culminated in the extensive site investigation undertaken by Intergeo in 1998. In total 50 boreholes, 90 probeholes and 60 trial pits were used to investigate the site and around 4000 solid and 1300 liquid samples were tested in the laboratory for chemical substances. The investigations identified total petroleum hydrocarbons in the soil up to 25, 000mg/kg. Diesel oil, with some lubricating oil were the main components. Volatile organic compounds were identified in the groundwater in excess of 10mg/l. Specific substances included trichloromethane, trichloromethane and tetrachloroethene. Both the oil and volatile compounds were widely spread across the site, The specific substances identified could be traced back to industrial processes used at one or other dates in the sites history Slightly elevated levels of toxic metals and polycyclic aromatic hydrocarbons were also identified locally. Prior to remediation of the site and throughout its progress, extensive liaison with the regulatory authorities and the client's professional representatives was required. In addition to meetings, numerous technical documents detailing methods and health and safety issues were required in order to comply with UK environmental and safety legislation. After initially considering a range of options to undertake remediation, the following three main techniques were selected: ex-situ bioremediation of hydrocarbon contaminated soils, skimming of free floating hydrocarbon product from the water surface at wells and excavations and air stripping of volatile organic compounds from groundwater recovered from wells. The achievements were as follows: 1) 350, 000m3 of soil was excavated and 112, 000m3 of sand and gravel was processed to remove gravel and cobble sized particles; 2) 53, 000m3 of hydrocarbon contaminated soil was bioremediated in windrows ; 3) 7000m3 of groundwater was processed by skimming to remove free floating Product; 4) 196, 000m3 of groundwater was Processed by air stripping to remove volatile organic compounds. Only 1000m3 of soil left the site for disposal in licensed waste facilities Given the costs of disposal in the UK, the selected methods represented a considerable cost saving to the Clients. All other soil was engineered back into the ground to a precise geotechnical specification. The following objective levels were achieved across the site 1) By a Risk Based Corrective Action (RBCA) methodology it was demonstrated that soil with less that 1000mg/kg total petroleum hydrocarbons did not pose a hazard to health or water resources and therefore, could remain insitu; 2) Soils destined for the residential areas of the site were remediated to 250mg/kg total petroleum hydrocarbons; in the industrial areas 500mg/kg was proven acceptable. 3) Hydrocarbons in groundwater were remediated to below the Dutch Intervegtion Level of 0.6mg/1; 4) Volatile organic compounds/BTEX group substances were reduced to below the Dutch Intervention Levels; 5) Polycyclic aromatic hydrocarbons and metals were below Inter-departmental Committee for the Redevelopment of Contaminated Land guideline levels for intended enduse. In order to verify the qualify of the work 1500 chemical test results were submitted for the purpose of validation. Quality assurance checks were undertaken by independent consultants and at an independent laboratory selected by Intergeo. Long term monitoring of water quality was undertaken for a period of one year after remediation work had been completed. Both the regulatory authorities and Clients representatives endorsed the quality of remediation now completed at the site. Subsequent to completion of the remediation work Redrew Homes constructed a prestige housing development. The properties at "Belvedere Place" retailed at premium prices. On the MEPC site the Post Office, amongst others, has located a major sorting office for the London area. Exceptionally high standards of remediation, control and documentation were a requirement for the work undertaken here.aken here.

  • PDF