• Title/Summary/Keyword: Safety Standard Guideline

Search Result 175, Processing Time 0.03 seconds

A Study on the Actual Condition and Improvement of Safety Management for Promising Small & Medium Enterprise (In Capital City Area) (유망 중소기업의 안전관리 실태와 대책에 관한 연구 (수도권을 중심으로))

  • 명노풍;태순호;김용수
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.2
    • /
    • pp.140-147
    • /
    • 1999
  • Currently, the consumer pattern is directed to small quantity and high variety these days. World market is led by technological innovations and changes rapidly. To survive in this environment, the raising of small and medium enterprises is highly desirable. In the context of nationwide restructuring, competitive medium and small industries which are in good financial status should lead the nation's economy. But general ignorance of the safety issues could lead to a miss management of this industry in this field. In this study, actual condition and improvement of safety management are as follows; We have to 1) find out the factors which endangers this industry, and set a proper guideline for safety management. 2) encourage safety management of these industries by themselves, and advertise and provide technical support for using PC and internet. 3) set a higher standard of safety issue when accrediting a prospective medium and small industry, and have a firm control of this issue once accredited. 4) supply more governmental financial aids to terms of safety issues for medium and small industries.

  • PDF

Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline (공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석)

  • Shin, Hansu;Song, Hye-Jin;Byun, Jin-Kyu
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.

A Basic Study on the Improvement of Software Reliability of Signaling Safety System (신호보안시스템의 소프트웨어 신뢰성 향상에 관한 기초연구)

  • 김종기;이종우;정의진;조봉관
    • Proceedings of the KSR Conference
    • /
    • 2001.05a
    • /
    • pp.319-326
    • /
    • 2001
  • Railway signaling safety system organizes equipments and facilities of railway, increases transport efficiency and assures safe operation of railway. In the early days of signaling system railway managers made sure of safety by using relay logic technology based on fail-safe concept. But the development result of computer and science having been introduced to railway industry, railway signaling equipments begin to be operated through micro electronic control system. Accordingly high speed and high density operation of train became possible. Software reliability and safety technology that controls important systems of railway was highlighted. In the middle of 1990s the standard or guideline of railway reliability and safety were studied and established, and are being reviewing in Europe, Japan etc. Our reliability and safety technology have depended largely on foreign countries. In this study we performed a basic study about the reliability of software that controls the railway signaling system.

  • PDF

Need for Korean Industrial Standards (KS) for Acupuncture Needle (침의 한국산업규격(KS) 도입 필요성에 대한 고찰)

  • Jang, In-soo;Park, Jong-bae;Seo, Jung-chul
    • Journal of Acupuncture Research
    • /
    • v.21 no.5
    • /
    • pp.149-162
    • /
    • 2004
  • Quality assurance with high safety profile is one of the most critical issues to medical device manufacturing. In general, this issue was not paid proper attention with respect to acupuncture needle and its related devices. Acupuncture needles are manufactured through various standards ranging from purely hand-made, partially hand-made and partially machine-made, to fully machine-made mainly in China, Korea, and Japan. There is a large difference in quality between needles from different manufacturers. In order to provide a standard manufacturing guideline, it seems necessary to make a Korean Industrial standard (KS). The authors review this topic from an historical view point, investigate the current situation of the standardization of acupuncture needles in other developed countries, and inspect the general procedure to establish a KS in Korea in order to suggest a KS for acupuncture needles.

  • PDF

A Study on the Improvement of Performance Standard and Classification for the Firestop Accreditation System (내화충전구조 인정제도의 성능기준 및 등급분류 개선에 관한 연구)

  • Lee, H.D.;Choi, Y.J.;An, J.H.;Jeong, A.Y.;Seo, H.W.;Park, Jin O
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.32-39
    • /
    • 2020
  • The fire compartments with fire-resistant construction are installed in the principal structural parts of a building in order to reduce damage in the event of a building fire. As a fire may spread through a crack in the fire compartment, the firestop with secured performance is used according to the procedure, methods, and standards specified in the detailed operation guideline. According to the current detailed operation guideline, vertical members (wall penetration) and horizontal members (floor penetration) are classified into different categories respective to each other for the classification of the firestop. Therefore, an accreditation applicant must apply for the performance test for each structure even if the wall and the floor have the same structure. Also, Grade T is used for the firestop that penetrates the fire compartment. However, in the case of foreign countries, the use of Grade F for the firestop is allowed even if it penetrates the fire compartment. The result of the precedent studies also showed that there was a significantly low possibility of fire to spread even if Grade F was applied for a metallic duct that penetrated the fire compartment. In this study, the improved scheme for the classification and performance standard of firestops was presented by analyzing the results of precedent studies regarding the firestop and domestic and overseas firestop qualification systems.

Study on the Negligible Extent(NE) and Release Characteristic of KS C IEC 60079-10-1(2015) Standard (KS C IEC 60079-10-1 규격의 무시할 수 있는 정도와 누출특성에 관한 연구)

  • Cho, Pil-rae;Lee, Hyang-jig;Baek, Jong Bae
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.111-117
    • /
    • 2020
  • When KS C IEC 60069-10-1(2015) standard is applied to estimate a hazardous area, the chart showing the relationship between a hazardous area distance and release characteristic is used as a guide to determine the extent of hazardous zones for various forms of release. Three release characteristic lines based on the three types of release as an unimpeded jet release with high velocity, a diffusive jet release with low velocity, and a release of heavy gases or vapours that spread along horizontal surfaces are given. As these characteristic lines have the low limit threshold, it is difficult to estimate the hazardous area distance when the value of release characteristic is under the low limit threshold. And KS C IEC 60079-10-1(2015) standard shows the concept for a zone of Negligible extent(NE) which can be considered as non hazardous area, but it is also difficult to apply the concept of a Negligible extent. The purpose of this paper is to suggest the guideline for the release characteristic to decide a hazardous area distance and the Negligible extent(NE) being considered as non-hazardous area when deciding a hazardous area distances by the KS C IEC 60079-10-1 standard.

Discussion about the Self Disposal Guideline of Medical Radioactive Waste (의료용 방사성폐기물 자체처분 가이드라인에 관한 고찰)

  • Lee, Kyung-Jae;Sul, Jin-Hyung;Lee, In-Won;Park, Young-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.21 no.2
    • /
    • pp.13-27
    • /
    • 2017
  • Purpose In the procedure of domestic medical radioactive self-disposal, there are many requests of supplementation and difficulties on the screening process. In this regard, presentation of basic guideline will improve the work processing efficiency of medical institution radioactive waste. From 2015 to 2016, We reviewed and compared a supplementary requests of domestic fifteen medical institution radioactive self-disposal Plan & Procedure manual. In connection with this, we derive the details of the radioactive waste document based on the relative regulation of nuclear safety Act. The representative supplementary requests of Korea Institute of Nuclear Safety are disposal method of non-flammability radioactive waste, storage method of scheduled self-disposal waste, the legitimacy of self-disposal and pre-treatment of self-disposal, reference radioactivity of disused filter and output of storage period, attachment the evidential matter of measurement efficiency when using a gamma counter. Through establishing a medical radioactive waste guideline, we can clearly suggest a classification standard of radioactive nuclide and the type of occurrence. As a result, we can confirm the reduction of examination processing period while preparing a self-disposal document and there is no spending expenses for business agency. Also, the storage efficiency of facility will better and reduce the economic expenses. On the basis of this guideline, we will expect a contribution to the improvement of work efficiency for officials who has a working-level difficulty of radioactive waste self-disposal.

  • PDF

A Basic Study on Safe Mooring Guide for Dangerous Goods Berths in Ul-San Port (울산항 위험물 부두의 안전계류에 관한 기초연구)

  • Kang, Won-Sik;Park, Young-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.1
    • /
    • pp.67-73
    • /
    • 2016
  • This study analyzed the state of the vessels which were using the berth for dangerous goods more than its carrying capacity in the major dangerous cargo handling port of Ulsan in Korea, The result of the analysis showed that a ship which has 3 times more than the maximum berthing capacity was moored at berth. Accordingly, a simulation model for 50,000 DWT berth was built and carried out the mooring safety analysis with 50,000 DWT, 70,000 DWT and 100,000 DWT vessels by mooring assessment program. The evaluation was carried out according to the standard environment presented in OCIMF standards. 50,000 DWT vessel was evaluated to meet the acceptable criteria but, 70,000 DWT and 100,000 DWT vessels exceeded the acceptable limit as per external conditions. Consequently, safe mooring guidelines were suggested and also proposed the building of common 'Mooring safety guideline' for port with assessment of different cases.

Study on the Safety Assurance for the Temporary Structures (가설구조물 안전성 확보 방안 연구)

  • Lee, Jung Seok;Moon, Seong Oh;Youn, Ye Bin;Lim, Nam Gi;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.73-80
    • /
    • 2018
  • According to the statistics publication of KOSHA, more than half of serious accidents at the construction sites were related to the temporary works and/or the temporary structures such as scaffoldings, shores, earth retaining walls, etc. The structural failures are occurred because of the overload acting on the structures or lack of performance of the one or more members of the structures. For the prevention of the collapse accidents relating to the temporary structures at the construction sites, we have to control construction processes not to occur the overload and also to control the performance and quality of each member of the temporary structures. MOLIT has amended the "Construction Technology Promotion Act" on Jan. 7th, 2015 to ensure the structural safety of the temporary structures. According to the Act, the designers of the construction design projects should check the structural integrity of the structures including the temporary structures and the construction companies have to let 'the Relative Professionals' confirm the structural integrity of temporary structures, the shores(${\geq}5m$ high) and the scaffolds(${\geq}31m$ high), before construction. Also, MOLIT has amended the "Regulation for Construction Technology Promotion Act" on Jul. 4th, 2016 for quality management and testing of temporary equipments. According th this regulation, the construction companies and supervisors should manage and test the temporary equipments before using them. In this paper, the standard drawings of the shores(< 5 m high) and the scaffolds(< 31 m high) and the amended "Business Guideline for Quality Management of Construction Work" are presented. As the result of this study, MOLIT noticed the amended "Business Guideline for Quality Management of Construction Work" on Jul. 1st, 2017.

Analysis of multiple spurious operation scenarios of Korean PHWRs using guidelines of nuclear power plants in U.S.

  • Kim, Jaehwan;Jin, Sukyeong;Kim, Seongchan;Bae, Yeonkyoung
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1765-1775
    • /
    • 2019
  • Multiple spurious operations (MSOs) mean multiple fire induced circuit faults causing an undesired operation of one or more systems or components. The Nuclear Energy Institute (NEI) of the United States published NEI 00-01 as guidelines for solving MSOs. And this guideline includes MSO scenarios of pressurized water reactor (PWR) and boiling water reactor (BWR). Nuclear power plant operators in U.S. analyzed MSOs under MSO scenarios included in NEI 00-01 and operators of PWRs in Korea also analyzed MSOs under the scenarios of NEI 00-01. As there are no pressurized heavy water reactors (PHWRs) in the United States, MSO scenarios of PHWRs are not included in the NEI 00-01 and any feasible scenarios have not been developed. This paper developed MSO scenarios which can be applied to PHWRs by reviewing the 63 MSO scenarios included in NEI 00-01. This study found that seven scenarios out of the 63 MSO scenarios can be applied and three more scenarios need to be developed.