• Title/Summary/Keyword: Safety Management Evaluation System

Search Result 667, Processing Time 0.035 seconds

Improving Efficiency of Food Hygiene Surveillance System by Using Machine Learning-Based Approaches (기계학습을 이용한 식품위생점검 체계의 효율성 개선 연구)

  • Cho, Sanggoo;Cho, Seung Yong
    • The Journal of Bigdata
    • /
    • v.5 no.2
    • /
    • pp.53-67
    • /
    • 2020
  • This study employees a supervised learning prediction model to detect nonconformity in advance of processed food manufacturing and processing businesses. The study was conducted according to the standard procedure of machine learning, such as definition of objective function, data preprocessing and feature engineering and model selection and evaluation. The dependent variable was set as the number of supervised inspection detections over the past five years from 2014 to 2018, and the objective function was to maximize the probability of detecting the nonconforming companies. The data was preprocessed by reflecting not only basic attributes such as revenues, operating duration, number of employees, but also the inspections track records and extraneous climate data. After applying the feature variable extraction method, the machine learning algorithm was applied to the data by deriving the company's risk, item risk, environmental risk, and past violation history as feature variables that affect the determination of nonconformity. The f1-score of the decision tree, one of ensemble models, was much higher than those of other models. Based on the results of this study, it is expected that the official food control for food safety management will be enhanced and geared into the data-evidence based management as well as scientific administrative system.

Management of asymptomatic to mild COVID-19 patients with Cheongpebaedok-tang on the telemedical basis: A retrospective observational case series

  • Sung-Woo Kang;Kwan-Il Kim;Mideok Song;Jinhwan Roh;Namhun Cho;Heung Ko;Sung-Se Son;Minjeong Jeong;Jun-Yong Choi;Ojin Kwon;Seojung Ha;Hee-Jae Jung;Beom-Joon Lee
    • The Journal of Korean Medicine
    • /
    • v.44 no.4
    • /
    • pp.41-58
    • /
    • 2023
  • Objectives: This retrospective observational study aimed to investigate the efficacy and safety of Cheongpebaedok-tang, a traditional Korean herbal medicine, provided via telemedicine to patients with asymptomatic to mild COVID-19 in Korea. Methods: From February to April 2020, a retrospective analysis investigated COVID-19 patients treated via Korean telemedicine. The study involved asymptomatic to mild cases receiving Cheongpebaedok-tang more than three times, along with continuous Korean medicine care in convalescence. Diagnoses and treatment adhered to the telemedicine guidelines of the Association of Korean Medicine, with varied Cheongpebaedok-tang prescriptions based on symptom severity. Symptom evaluation involved a detailed assessment using a 15-item tool at initial and final sessions. Results: The study included 27 patients, with a mean age of 48.7 ± 2.3 years (mean ± standard error). Patients began self-administering oral Cheongpebaedok-tang for an average of 19.4 ± 1.8 days after the date of COVID-19 diagnosis confirmation and continued the medication for 15.8 ± 1.2 days. The reported side effects of the Cheongpebaedok-tang included palpitations (11.1%), insomnia (7.4%), dizziness (3.7%), and diarrhea (3.7%). All side effects disappeared after adjusting the prescription according to standard treatment guidelines. The occurrence of all COVID-19-related adverse symptoms, except fatigue and myalgia, decreased. Fatigue was the most common chronic symptom persisting after 6 months (51.9%), followed by ocular symptoms (37.0%) and sore throat (22.2%). Conclusions: This study implies Cheongpebaedok-tang may offer a potentially safe, symptom-alleviating approach for managing mild COVID-19 cases via telemedicine, although further comprehensive research is warranted.

A study on measures for the mitigation of fire damage in Korea super high-rise building through the improvement of domestic·foreign standards (국·내외 기준개선을 통한 국내 초고층 건축물의 화재피해경감 대책에 관한 연구)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.2
    • /
    • pp.233-248
    • /
    • 2017
  • Uniform laws and regulations and reasonable design is necessary for the prevention of possible fire in super high-rise building. To this end, this study focused on super high-rise and massive building-related architectural review performance-based design (PBD) evaluation disaster impact assessment (DIA), and provided fire engineering measures for improving fire prevention on the basis of performance-based design by analyzing the buildings subject to these systems and problems in terms of contents. Above all, in the aspect of law and standard improvement, first, with regard to dual parts of two statutes though significant portion of them has the same contents in performance-based design (PBD) evaluation and disaster impact assessment (DIA), it is necessary to operate the systems after making them conform with each other and consolidating or abolishing them. Second, if it is impossible to consolidate or abolish performance-based design (PBD) evaluation and disaster impact assessment (DIA), the areas of contents of performance-based design (PBD) evaluation and disaster impact assessment (DIA) should be precisely classified and established. Next, engineering improvement measures against fire hazard in super high-rise building are as follows. First, it is necessary to revise the provisions of straight-run stairs in special escape stairs. And in case of installing a mechanical smoke exhaust system instead of smoke vent, sandwich pressurization used in the United Stated should be permitted. Second, with regard to smoke control system for special escape stairs, it was shown that there was necessity for revising the standards in order to enable air to be supplied according to section in case of fire, carrying out performance-based design, and the like from the early design stages to the completion stages. In the future, it is expected that an epoch-making contribution will be made to a decrease in casualties and property damage due to fire in case of super high-rise building where the results can be reflected after carrying out a study on maintenance and carrying out an additional study on other considerations of super high-rise building together with reflecting the improvement measures provided in the above-mentioned study.

Improvement of Certification Criteria based on Analysis of On-site Investigation of Good Agricultural Practices(GAP) for Ginseng (인삼 GAP 인증기준의 현장실천평가결과 분석에 따른 인증기준 개선방안)

  • Yoon, Deok-Hoon;Nam, Ki-Woong;Oh, Soh-Young;Kim, Ga-Bin
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.40-51
    • /
    • 2019
  • Ginseng has a unique production system that is different from those used for other crops. It is subject to the Ginseng Industry Act., requires a long-term cultivation period of 4-6 years, involves complicated cultivation characteristics whereby ginseng is not produced in a single location, and many ginseng farmers engage in mixed-farming. Therefore, to bring the production of Ginseng in line with GAP standards, it is necessary to better understand the on-site practices of Ginseng farmers according to established control points, and to provide a proper action plan for improving efficiency. Among ginseng farmers in Korea who applied for GAP certification, 77.6% obtained it, which is lower than the 94.1% of farmers who obtained certification for other products. 13.7% of the applicants were judged to be unsuitable during document review due to their use of unregistered pesticides and soil heavy metals. Another 8.7% of applicants failed to obtain certification due to inadequate management results. This is a considerably higher rate of failure than the 5.3% incompatibility of document inspection and 0.6% incompatibility of on-site inspection, which suggests that it is relatively more difficult to obtain GAP certification for ginseng farming than for other crops. Ginseng farmers were given an average of 2.65 points out of 10 essential control points and a total 72 control points, which was slightly lower than the 2.81 points obtained for other crops. In particular, ginseng farmers were given an average of 1.96 points in the evaluation of compliance with the safe use standards for pesticides, which was much lower than the average of 2.95 points for other crops. Therefore, it is necessary to train ginseng farmers to comply with the safe use of pesticides. In the other essential control points, the ginseng farmers were rated at an average of 2.33 points, lower than the 2.58 points given for other crops. Several other areas of compliance in which the ginseng farmers also rated low in comparison to other crops were found. These inclued record keeping over 1 year, record of pesticide use, pesticide storages, posts harvest storage management, hand washing before and after work, hygiene related to work clothing, training of workers safety and hygiene, and written plan of hazard management. Also, among the total 72 control points, there are 12 control points (10 required, 2 recommended) that do not apply to ginseng. Therefore, it is considered inappropriate to conduct an effective evaluation of the ginseng production process based on the existing certification standards. In conclusion, differentiated certification standards are needed to expand GAP certification for ginseng farmers, and it is also necessary to develop programs that can be implemented in a more systematic and field-oriented manner to provide the farmers with proper GAP management education.

Evaluation on Feasibility of Industrial By-products for Development of Mono-Layer Landfill Cover System (산업부산물을 이용한 단층형 매립지 복토시스템 개발을 위한 적용 타당성 평가)

  • Kim, Soon-Oh;Kim, Pil-Joo;Yu, Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.11
    • /
    • pp.1075-1086
    • /
    • 2008
  • In order to investigate the applicability and suitability of the industrial by-products to apply mono-layer cover system for non-sanitary landfill sites, 6 different industrial by-products, such as construction waste, bottom ash, gypsum, blast furnace and steel manufacture slags, and stone powder sludge, were evaluated. Various physicochemical and hydrodynamic properties of the industrial byproducts were investigated. The environmental safety was monitored using batch and long-term leaching tests as well. In addition, the flexibility of plants was observed by cultivating them in the industrial by-products. The results for physicochemical properties indicate that most of the materials considered appeared to be suitable for landfill cover. Particularly, the concentration levels of hazardous elements regulated by the Korean Law for Waste Management did not exceed the regulatory limits in all target materials. In addition, the concentrations of regulated elements for the Korean Soil Conservation Law were examined below the regulatory limits in most of materials considered, except for the stone powder sludge. The results of batch and long-term experiments showed bottom ash and construction waste were the most suitable materials for landfill cover among the industrial by-products considered. The results of plant studies indicate that the bottom ash among industrial by-products considered was most effective in developing vegetation on landfill site, showing fast germination and large growth index. At the final covering system made of mixture of soil and bottom ash, the optimum application rate of farmyard manure was observed to be 40-50 Mg/ha.

Developing a Model for Crime Prevention Hardware Performance Test and Certification System (방범하드웨어의 침입범죄 저항성능 시험·인증 체계에 관한 모형 연구)

  • Park, Hyeon-ho
    • Korean Security Journal
    • /
    • no.36
    • /
    • pp.255-292
    • /
    • 2013
  • Burglary (also called breaking and entering and sometimes housebreaking) is a crime, the essence of which is illegal entry into a building for the purposes of committing an offence. It is one of the most common types of crime and also a serious issue for every society. A house that is left insecure is an accessible and attractive target for burglars and therefore burglary resistance test & certification system for doors and windows has been developed in many countries. This paper explores several advanced foreign burglary resistance test/certifcation cases (the British SBD, the Dutch KOMO SKH/SKG, the Japanese CP mark, the Australian Standard Certification) for security products and domestic test/certification systems for fire safety products as a comparative study so that any improvement points can be gained for South Korea in the field of security product performance. The comparative analysis results show that South Korea is far behind the security product certification system and needs a lot of improvement in the system by benchmarking foreign cases. The domestic test/certification systems for fire safety products also give some insights for burglary-related security products' performance certification system in Korea. Overall, the need for relevant rules and regulations, the establishment of standards regarding testing and certification, including certified security +hardware product in building security certification system, performance testing as well as production testing (i.e. quality management system evaluation), the basic competency of testers, incentive system for certified/high quality security products were suggested in order to make an optimal model for the security production performance testing and certification system in Korea.

  • PDF

Risk Perception of the Firefighters Responsible for Nuclear Power Plants: Construct Validity (원자력발전소 화재에 대한 관할 지역 소방관의 위험인식: 측정도구의 개발과 타당화)

  • Choi, HaeYoun;Lee, SangKyu;Choi, Jong-An
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.94-102
    • /
    • 2019
  • As the importance of first responses for fire accidents has grown in the safety management of nuclear power plants, a systematic approach to measure firefighters' psychological states and competence is needed. The current study investigated the construct of the risk perception of the firefighters working near nuclear power plant sites, and then developed and validated a new scale to measure firefighters' risk perception regarding nuclear power plant accidents. The scale items were developed on the basis of literature review and interviews with the firefighters working near nuclear power plant sites. In order to validate the new scale, we recruited 180 firefighters from five fire stations in the vicinity of the nuclear power plants in Jeonnam Province, Gyeongbuk Province, and Busan. The results of exploratory factor analyses revealed that the scale consisted of five factors: "manual" reflecting a lack of response guidelines and manuals for fire incidents and radioactive material release; "fear" reflecting a fear of fire incidents in the nuclear power plants and their catastrophic consequences; "resource" reflecting a lack of protective equipment and manpower for responding to fire incidents in the nuclear power plants; "trust" reflecting trust and cooperation with the counterpart institutions for firefighting in the nuclear power plants; and "knowledge" reflecting the knowledge of radioactivity and firefighting in the nuclear power plants. Further analyses provided statistical evidence supporting for the 15-item scale's internal consistency and construct validity. Finally, We discussed the implication and limitations of the current research.

Evaluation of Low Toxic and Residual Toxicity of Pesticides Registrated on Sweet Pepper Greenhouse to Orius strigicollis (으뜸애꽃노린재 성충에 대한 착색단고추에 등록된 농약의 저독성 및 잔류독성 평가)

  • Choi, Byeong-Ryeol;Park, Hyung-Man;Kim, Jeong-Hwan;Lee, Si-Woo
    • Korean journal of applied entomology
    • /
    • v.46 no.3
    • /
    • pp.415-423
    • /
    • 2007
  • For the development of integrated pest management system by harmonizing biological and chemical control, some experiments were carried out to select low toxic pesticides and to evaluate residual toxicity to natural enemies. Leaf dipping method and body dipping method were set up for evaluating toxicity to minute pirate bug, Orius strigicollis adult. We had tested 52 kinds of pesticides (33 insecticides, 19 fungicides) commonly used to control greenhouse insects, mites, and disease pests to natural enemies at the recommended concentration. Fourteen insecticides by body dipping method, 12 insecticides by leaf dipping method and 19 fungicides were selected as low toxic pesticides to O. strigicollis adult. After insecticide spraying at recommending dose on the sweet pepper plant, we examined residual effect of insecticides by introducing natural enemies on different days. Safety interval for introduction of O. strigicollis adult was established according to residual toxicity of pesticides. Safety insecticides at one day after treatment were pyraclofos, methomyl, thiodicarb, esfenvalerate bifenthrin, alpha-cypermethrin, etofenprox, fenvalerate, imidacloprid, acetamiprid, abamectin, emamectin benzoate, spinosad, indoxacarb. However, residual toxicity of nee-nicotinoids last up to 21 days to O. strigicollis adults.

A Study on the Standard Test Method for Thermal Resistance of Military Textile Thermal Insulator for Winter Season (방한을 목적으로 하는 군용 섬유제품 충전재의 보온성 시험방법에 대한 표준화 연구)

  • Yeo, Yong-heon;Hong, Seong-don;Lee, Min-hee;Kim, Kyung-pil;Chung, Il-han
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.492-500
    • /
    • 2018
  • The performance evaluation of cold weather clothing is mainly carried out with thermal resistance. However, the results of the revised test method regarding the same specimen were decreased compare to previous one. In addition, there were deviations of the results among the authorized testing institutes according to the different interpretation of the KS test method. This makes it a considerable difficulty to the quality assurance of combat supplies. The purpose of this study is to minimize the variation of the results before and after the revision by analyzing the cause of the decrease in the heat insulation rate according to the revised test method. For this purpose, the difference between the test conditions before and after the revision of KS is analyzed and the possible results are reviewed. In addition, we want to minimize the result deviation between testing laboratories by analyzing the cause of the result deviation between test laboratories according to arbitrary interpretation of the standard. Based on this, we propose a standardized test method to prevent the decrease of the heat insulation rate by checking the pre-revision test method and the condition with the least deviation.

Heavy concrete shielding properties for carbon therapy

  • Jin-Long Wang;Jiade J Lu;Da-Jun Ding;Wen-Hua Jiang;Ya-Dong Li;Rui Qiu;Hui Zhang;Xiao-Zhong Wang;Huo-Sheng Ruan;Yan-Bing Teng;Xiao-Guang Wu;Yun Zheng;Zi-Hao Zhao;Kai-Zhong Liao;Huan-Cheng Mai;Xiao-Dong Wang;Ke Peng;Wei Wang;Zhan Tang;Zhao-Yan Yu;Zhen Wu;Hong-Hu Song;Shuo-Yang Wei;Sen-Lin Mao;Jun Xu;Jing Tao;Min-Qiang Zhang;Xi-Qiang Xue;Ming Wang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2335-2347
    • /
    • 2023
  • As medical facilities are usually built at urban areas, special concrete aggregates and evaluation methods are needed to optimize the design of concrete walls by balancing density, thickness, material composition, cost, and other factors. Carbon treatment rooms require a high radiation shielding requirement, as the neutron yield from carbon therapy is much higher than the neutron yield of protons. In this case study, the maximum carbon energy is 430 MeV/u and the maximum current is 0.27 nA from a hybrid particle therapy system. Hospital or facility construction should consider this requirement to design a special heavy concrete. In this work, magnetite is adopted as the major aggregate. Density is determined mainly by the major aggregate content of magnetite, and a heavy concrete test block was constructed for structural tests. The compressive strength is 35.7 MPa. The density ranges from 3.65 g/cm3 to 4.14 g/cm3, and the iron mass content ranges from 53.78% to 60.38% from the 12 cored sample measurements. It was found that there is a linear relationship between density and iron content, and mixing impurities should be the major reason leading to the nonuniform element and density distribution. The effect of this nonuniformity on radiation shielding properties for a carbon treatment room is investigated by three groups of Monte Carlo simulations. Higher density dominates to reduce shielding thickness. However, a higher content of high-Z elements will weaken the shielding strength, especially at a lower dose rate threshold and vice versa. The weakened side effect of a high iron content on the shielding property is obvious at 2.5 µSv=h. Therefore, we should not blindly pursue high Z content in engineering. If the thickness is constrained to 2 m, then the density can be reduced to 3.3 g/cm3, which will save cost by reducing the magnetite composition with 50.44% iron content. If a higher density of 3.9 g/cm3 with 57.65% iron content is selected for construction, then the thickness of the wall can be reduced to 174.2 cm, which will save space for equipment installation.