광파표지 등광에 관한 고찰과 향후 기술개발에 대한 전망 (The Study of lantern-lighting in navigational aids system and the view of its hereafter technical development)

  • 권혁동;홍태호;박계각
    • 해양환경안전학회:학술대회논문집
    • /
    • 해양환경안전학회 2003년도 춘계학술발표회
    • /
    • pp.117-123
    • /
    • 2003
  • It is impossible to apply present standards and test methods because the radiation principle and mechanism of a new marine lantern using light emitting diodes is different from those of the existing marine lantern which uses an incandescent electric lamp. Thus. in this study, we discuss the research and development on the light emitting diodes marine lantern and specifications.

  • PDF

A STUDY ON THE EXPLOSION SAFETY ASSESSMENT OF HYDROCARBON REFRIGERANT REFRIGERATOR

  • Oh, Kyu-Hyung;Kim, Min-Kyu;Chu, Euy-Sung;Lim, Byung-Han;Kim, Man-Hoe;Park, Yoon-Ser
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.289-296
    • /
    • 1997
  • This paper discribes an experimental explosion risk assessment study on refrigerators containing flammable hydrocarbon refrigerant. A refrigerator used in this study is a larder fridge type, 215 liter in volume. The hydrocarbon refrigerant used in the refrigerator is iso-butane(C$_4$H$_{10}$). For the explosion safety assessment of the refrigerator, temperature of compressor, cooling air circulation fan motor, defrost heater and inner lamp were measured during the operation. And to confirm the ignitablity of flammable gas by the electric spark of the switches of the refrigerator, ON-OFF test of all switches were conducted with compulsorily near the stoichiometric concentration atmosphere of iso-butane-air mixture. As the result of experiment above mentioned and another experiment for the explosion safety assessment, we can conclude that explosion hazard in connection with the use of hydrocarbon refrigerant was few.w.

  • PDF

농업용 트랙터 제동등 광도 성능 평가 (Evaluation of the Luminous Intensity Distribution of Stop Lamp for Agricultural Tractors)

  • 김형권;김유용;신승엽;김병갑;이호상
    • Journal of Biosystems Engineering
    • /
    • 제36권6호
    • /
    • pp.416-421
    • /
    • 2011
  • This study was initiated to prevent rear-end collision which causes the most frequent human damage by agricultural tractors. Therefore, this study was aimed to evaluate the luminous performance of a stop lamp for an agricultural tractor which could reduce rear-end collision. The performance test of luminous intensity distribution was conducted for a total of 12 tractor models classified by size (above 44 kW for large, 30~43 kW for medium, and below 29 kW for small) and production area (domestic, foreign manufacture) in accordance with Regulation No.7 of UNECE Vehicle Regulations-1958 Agreement considering ${\pm}$20 standard deviation. Three out of 5 large, 3 out of 4 medium, and all small tractors were resulted as inadequate for the test criterion. This study found that the luminous performance results were better as the size of agricultural tractors became bigger. One out of 4 foreign and 2 out of 8 domestic manufacturers were suitable for the test criterion, and overall no difference from the luminosity test results was observed between domestic and foreign manufacturers. In addition, the measuring points, HV, 5L, 5R, 5U and 5D with the minimal luminosity revealed flaws (80% of the proportion of faulty products). Therefore, it is urgent to improve the quality for measuring points (HV, 5U, 5L, 5R, 5D) of stop lamps to apply Regulation No. 7.

방전램프의 역률 보상용 콘덴서를 이용한 저가형 LED 구동회로 (Low-Cost LED Driver Circuit using Power Factor Compensation Capacitor of Discharge Lamp)

  • 고재하;황정구;박성미;박성준
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.16-25
    • /
    • 2013
  • Now it's a trend to install a series of white fluorescent light and orange high pressure sodium lamps because tunnel lighting should be opaque to the safety of drivers from soot, dust, humidity, and fog. Also fluorescent lighting is replaced to LED due to the fact that it improves amenity and object recognition and LED lighting has gradually been improved its nature. In this paper, we have implemented the circuits of the yellow series of high-pressure sodium lamps and white series of LED lights at one board to improve the transparency and recognition of objects. It is possible for inductive high-pressure sodium lamps and the capacitive LED drivers to circuit without power factor compensation. Two circuit parts share only a small number of parts, so low cost LED drivers compared to conventional ones are possible. Therefore, the implementation of the hybrid lighting with high-pressure sodium lamps and LED lights that can be driven at the same time by one driving circuit is possible. The LED capacitive power factor was 0.91 while individually implemented the sodium lamp power factor was 0.98. It shows not only the 2% improvement of hybrid forms but also the efficiency and THD.

임대주택단지의 생활안전 위해요인 해소방안 (Resolution Method of Hazard Factor for Life Safety in Rental Housing Complex)

  • 손정락;조건희;김진원;송상훈
    • 토지주택연구
    • /
    • 제8권1호
    • /
    • pp.1-11
    • /
    • 2017
  • The government has been constructing and supplying public rental housing to ordinary people in order to stabilize housing since 1989. However, the public rental houses initially supplied to ordinary people are at high risk for safety accidents due to the deterioration of the facilities. Therefore, this study is aimed to propose a solution to solve the life safety hazards of the old rental housing complex as a follow-up study of Analysis of Accident Patterns and Hazard Factor for Life Safety in Rental Housing Complex. Types of life safety accidents that occur in public rental housing complexes are sliding, falling, crash, falling objects, breakage, fire accidents, traffic accidents and criminal accidents. The types of safety accidents that occur in rental housing complexes analyzed in this study are sliding, crashes, falling objects, and fire accidents. Although the incidence of safety accidents such as falling, breakage, traffic accidents and crime accidents in public rental housing complexes is low, these types are likely to cause safety accidents. The method of this study utilized interviews and seminar results, and it suggested ways to solve the life safety hazards in rental housing complexes. Interviews were conducted with residents and managers of rental housing complexes. Seminars were conducted twice with experts in construction, maintenance, asset management, housing welfare and safety. Through interviews and seminars, this study categorizes the life safety hazards that occur in rental housing complexes by types of accidents and suggests ways to resolve them as follows. (1) sliding ; use of flooring materials with high friction coefficient, installation of safety devices such as safety handles, implementation of maintenance, safety inspections and safety education, etc. (2) falling ; supplementation of safety facilities, Improvement of the design method of the falling parts, Safety education, etc. (3) crash ; increase the effective width of the elevator door, increase the effective width of the lamp, improve the lamp type (U type ${\rightarrow}$ I type), etc. (4) falling objects and breakage ; design of furniture considering the usability of residents, replacement of old facilities, enhancement of safety consciousness of residents, safety education, etc. (5) fire accidents ; installation of fire safety equipment, improvement by emergency evacuation, safety inspection and safety education, etc. (6) traffic accidents ; securing parking spaces, installing safety facilities, conducting safety education, etc. (7) criminal accidents; improvement of CCTV pixels, installation of street lights, removal of blind spots in the complex, securing of security, etc. The roles of suppliers, administrators and users of public rental housing proposed in this study are summarized as follows. Suppliers of rental housing should take into consideration the risk factors that may arise not only in the design and construction but also in the maintenance phase and should consider the possibility of easily repairing old facilities considering the life cycle of rental housing. Next, Administrators of rental housing should consider the safety of the users of the rental housing, conduct safety checks from time to time, and immediately remove any hazardous elements within the apartment complex. Finally, the users of the rental housing needs to form a sense of ownership of all the facilities in the rental housing complex, and efforts should be made not to cause safety accidents caused by the user's carelessness. The results of this study can provide the necessary information to enable residents of rental housing complexes to live a safe and comfortable residential life. It is also expected that this information will be used to reduce the incidence of safety accidents in rental housing complexes.

Effects of Security Lighting Lamps on Discomfort Glare to Indoor Occupants

  • Lee, Yoon Jeong;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • 제15권4호
    • /
    • pp.21-28
    • /
    • 2015
  • Purpose: Although security lights are used to secure pedestrian visibility and safety at nighttime, they can generate light trespass in the neighboring residential space. To prevent this, standards for acceptance limits on vertical illuminance and light pollution by the windows of residential buildings are presented. Method: This study thus representatively selected three types of lamps and, through an evaluation and analysis of the physical and subjective discomfort glare per lamp, proposed a discomfort glare index for each lamp. The evaluation and analysis according to the lamps were conducted through experiments. The variables were the security lights' lamps (NH 100W, MH 70W, LED 50W), installation angles ($0^{\circ}$, $20^{\circ}$), and installation distances (3m, 5m, 7m, 9m). Result: According to the results of the discomfort glare evaluation depending on the angles and distances of the security lights, the following minimum standards are proposed: for NH 100W, a discomfort glare index of 30 and an installation distance of 4m; for MH 70W, a discomfort glare index of 32 and an installation distance of 4m; and, for LED 50W, a discomfort glare index of 31 and an installation distance of 6m, respectively. In addition, this paper recommends the use of MH 70W, when the road width is 4m-6m, and LED 50W, when the road width is over 6m, respectively.

배선 단선과 에어 누설에 관련된 자동차 ECS 시스템의 고장사례 고찰 (Study of Failure Examples of Automotive Electronic Control Suspension System Including Cases with Wiring Disconnection and Air Leakage)

  • 이일권;박종건;신명신;장주섭
    • Tribology and Lubricants
    • /
    • 제29권3호
    • /
    • pp.180-185
    • /
    • 2013
  • The purpose of this study was to analyze the tribological characteristics of the Electronic control suspension System in a car. In the first example, the cilp used to attach the front electronic control suspension(ECS) system's control actuator was fastened very tightly. Thus, the wire was cut because of continual rotation of the shock-up shover piston rod used to adjust the height of the car. This verified the disconnection phenomenon where wire damaged makes it impossible for the ECS system to send signal to the actuator. The second example, involved a minute hole that allowed gas to leak from the ECS system. As a result, the height of the car verified the down phenomenon. In the third example, the resistance of a wire measured at $0.21{\Omega}$, when the G sensor was disconnected from the system. This verified the system shutdown and lighting of the ECS warning lamp because of body interference caused by a slight pressure on the battery cover. Therefore, quality control is always necessary to ensure safety and durability of a car.

항공기 승객용 화학적 비상산소 공급 및 조명시스템에 대한 연구 (Research for the Chemical Emergency Oxygen Supply and Lighting System for Aircraft Passengers)

  • 김영인
    • 한국항공운항학회지
    • /
    • 제30권2호
    • /
    • pp.55-60
    • /
    • 2022
  • A PSU (passenger service unit) is mounted on passenger seats in a cabin on an aircraft and consists of a crew call lamp, a reading lights, an information display lamp, an emergency oxygen generator, and an emergency oxygen mask. It is a safety device for providing convenience to passengers and providing oxygen to passengers in an emergency. This paper is a study on emergency oxygen supply systems and light systems of aircraft PSUs and a control device was developed to operate the system by analyzing the B767-300 aircraft's PSU circuit diagram. And the temperature generated by the B777-200ER aircraft's emergency oxygen generator was also measured by operating it directly. Through this, precautions for explaining the operation of an oxygen mask in an emergency were described and improvements were presented. Data acquired in these research processes can be used in the future to develop aircraft PSU (passenger service unit) and emergency oxygen generators.

미세조류 4종(Chlorella vulgaris, Nitzschia sp., Phaeodactylum tricornutum, Skeletonema sp.)의 성장에 미치는 발광다이오드 단일파장의 영향 (Effect of Monochromatic Light Emitting Diode on the Growth of Four Microalgae Species (Chlorella vulgaris, Nitzschia sp., Phaeodactylum tricornutum, Skeletonema sp.))

  • 오석진;권형규;전진영;양한섭
    • 해양환경안전학회지
    • /
    • 제21권1호
    • /
    • pp.1-8
    • /
    • 2015
  • 본 연구는 규조류 Nitzschia sp., Phaeodactylum tricornutum, Skeletonema sp.와 녹조류 Chlorella vulgaris의 성장에 미치는 발광다이오드(LED) 단일파장의 영향을 파악하였다. 4종의 미세조류는 청색 LED(450 nm), 황색 LED(590 nm), 적색 LED(650 nm) 그리고 형광램프(복수파장)에서 배양하였다. Nitzschia sp., P. tricornutum 그리고 Skeletonema sp.의 최대성장속도와 최대세포밀도는 청색 LED에서 가장 높았고 형광램프, 적색 LED, 황색 LED 순이지만, C. vulgaris는 적색 LED에서 가장 높았다. 이는 청색 LED는 다른 파장에 비해서 규조류의 성장을 촉진시키는 작용을 하는 것으로 보인다. 따라서 미세조류의 단일파장 하에서 성장속도는 종 특이성 또는 분류군 특이성을 보이는 것으로 생각된다. 또한 이러한 결과는 향후 LED와 미세조류를 활용한 중금속 오염 퇴적물의 복원을 위한 중요한 정보로 활용 할 수 있을 것이다.

기능 안전성을 위한 대칭형 각도센서 보상기에 기반한 안전한 적응형 전조등 제어기의 설계 (Safe Adaptive Headlight Controller with Symmetric Angle Sensor Compensator for Functional Safety Requirement)

  • 윤지애;인멍디;안중현;조정훈;박대진
    • 대한임베디드공학회논문지
    • /
    • 제10권5호
    • /
    • pp.297-305
    • /
    • 2015
  • AFLS (Adaptive front lighting System) is being applied to improve safety in driving automotive at night. Safe embedded system for controlling head-lamp has to be tightly designed by considering safety requirement of hardware-dependent software, which is embedded in automotive ECU(Electronic Control Unit) hardware under severe environmental noise. In this paper, we propose an adaptive headlight controller with newly-designed symmetric angle sensor compensator, which is integrated with ECU-based adaptive front light system. The proposed system, on which additional backup hardware and emergency control algorithm are integrated, effectively detects abnormal situation and restore safe status of controlling the light-angle in AFLS operations by comparing result in symmetric angle sensor. The controlled angle value is traced into internal memory in runtime and will be continuously compared with the pre-defined lookup table (LUT) with symmetric angle value, which is used in normal operation. The watch-dog concept, which is based on using angle sensor and control-value tracer, enables quick response to restore safe light-controlling state by performing the backup sequence in emergency situation.