• 제목/요약/키워드: Safety Cup

검색결과 134건 처리시간 0.024초

노말테트라데칸의 연소특성치 측정에 의한 위험성 평가 (The Evaluation of Hazard by Measurement of Combustible Characteristics of n-Tetradecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.70-76
    • /
    • 2012
  • For the safe handling of n-tetradecane, the lower flash points and the upper flash point, fire point, AITs (auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-tetradecane were calculated. The lower flash points of n-tetradecane by using closed-cup tester were measured $104^{\circ}C$ and $112^{\circ}C$. The lower flash points and fire point of n-tetradecane by using open cup tester were measured $113^{\circ}C$ and $115^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-tetradecane. The experimental AIT of n-tridecane was $207^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $104^{\circ}C$ and upper flash point $140^{\circ}C$ for n-tetradecane were 0.63 Vol.% and 3.18 Vol%.

노말펜타데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Pentadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.53-57
    • /
    • 2013
  • For the safe handling of n-pentadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-pentadecane were calculated. The lower flash points of n-pentadecane by using closed-cup tester were measured $118^{\circ}C$ and $122^{\circ}C$. The lower flash points and fire point of n-pentadecane by using open cup tester were measured $126^{\circ}C$ and $127^{\circ}C$, respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-pentadecane. The experimental AIT of n-pentadecane was $195^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $118^{\circ}C$ and upper flash point $174^{\circ}C$ for n-pentadecane were 0.54 Vol.% and 6.40 Vol.%.

노말헥사데칸의 화재 및 폭발 특성치의 측정 (The Measurement of Fire and Explosion Properties of n-Hexadecane)

  • 하동명
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.39-45
    • /
    • 2014
  • For the safe handling of n-hexadecane, the lower flash points and the upper flash point, fire point, AITs(auto-ignition temperatures) by ignition delay time were experimented. Also lower and upper explosion limits by using measured the lower and upper flash points for n-hexadecane were calculated. The lower flash points of n-hexadecane by using the Setaflash and the Pensky-Martens closed testers were measured $128^{\circ}C$ and $126^{\circ}C$, respectively. The lower flash points of the Tag and the Cleveland open cup testers were measured $136^{\circ}C$ and $132^{\circ}C$, respectively. The fire points of the Tag and the Cleveland open cup testers were measured $144^{\circ}C$. respectively. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 apparatus for n-hexadecane. The experimental AIT of n-hexadecane was $200^{\circ}C$. The calculated lower and upper explosion limit by using measured lower $128^{\circ}C$ and upper flash point $180^{\circ}C$ for n-hexadecane were 0.42 Vol.% and 4.70 Vol.%.

페놀의 연소특성치의 측정 및 예측 (Measurement and Prediction of Combustion Properties of n-Phenol)

  • 하동명
    • 한국위험물학회지
    • /
    • 제6권2호
    • /
    • pp.23-29
    • /
    • 2018
  • The fire and explosion properties necessary for waste, safe storage, transport, process design and operation of handling flammable substances are lower explosion limits(LEL), upper explosion limits(UEL), flash point, AIT( minimum autoignition temperature or spontaneous ignition temperature), fire point etc., An accurate knowledge of the combustion properties is important in developing appropriate prevention and control measures fire and explosion protection in chemical plants. In order to know the accuracy of data in MSDSs(material safety data sheets), the flash point of phenol was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of phenol was measured by ASTM 659E apparatus. The explosion limits of phenol was investigated in the reference data. The flash point of phenol by using Setaflash and Pensky-Martens closed-cup testers were experimented at $75^{\circ}C$ and $81^{\circ}C$, respectively. The flash points of phenol by Tag and Cleveland open cup testers were experimented at $82^{\circ}C$ and $89^{\circ}C$, respectively. The AIT of phenol was experimented at $589^{\circ}C$. The LEL and UEL calculated by using Setaflash lower and upper flash point value were calculated as 1.36vol% and 8.67vol%, respectively. By using the relationship between the spontaneous ignition temperature and the ignition delay time proposed, it is possible to predict the ignition delay time at different temperatures in the handling process of phenol.

이소프로필 알코올의 화재 및 폭발 특성치의 측정 및 고찰 (The Measurement and Investigation of Fire and Explosion Characteristics of Isopropyl Alcohol)

  • 하동명
    • 한국가스학회지
    • /
    • 제16권3호
    • /
    • pp.8-15
    • /
    • 2012
  • 이소프로필 알코올의 안전한 취급을 위해 $25^{\circ}C$에서 폭발한계를 고찰하였고, 실험장치를 이용하여 하부인화점, 상부인화점, 연소점 그리고 발화지연시간에 의한 발화온도를 측정하였다. 그 결과, 공정의 안전을 위한 이소프로필 알코올의 폭발 하한계는 2.0 vol%이고, 상한계는 12.0 vol%로 문헌을 통해 판단되었다. 하부인화점은 밀폐계에서 $12{\sim}14^{\circ}C$와 개방식에서 $18{\sim}19^{\circ}C$이었고, 상부인화점은 $38^{\circ}C$로 측정되었다. ASTM E659 장치를 사용하여 측정된 최소자연발화온도는 $463^{\circ}C$이었다.

가연성 이성분계 용액인 2-Propanol+Propionic acid 와 n-Hexanol+Formic acid 용액의 밀폐식 인화점의 실험적 결정 (Experimental Determination of Closed Cup Flash Point of Binary Flammable Solutions, 2-Propanol+Propionic acid and n-Hexanol+Formic Acid Solutions)

  • 하동명;이성진
    • 한국가스학회지
    • /
    • 제19권3호
    • /
    • pp.18-24
    • /
    • 2015
  • 인화점은 액체 용액의 가장 중요한 인화성 지표 중 하나이다. 인화점은, 가연성 증기의 공기 속 농도가 점화가 발생하기에 충분할 때의 온도 중 가장 낮은 온도이다. 본 연구에서는 가연성 이성분계 액체 용액인, 2-propanol+propionic acid 와 n-hexanol+formic acid 계의 인화점을 Seta flash 밀폐식 장치를 사용하여 측정하였다. 특히 n-hexanol+formic acid 계는 최소 인화점 현상을 보였다. 측정값은 라울의 법칙을 활용한 방법과 최적화 기법에 의한 계산값과 비교되었다. 그 결과 최적화 기법에 의한 계산값이 라울의 법칙에 의한 계산값 보다 측정값을 잘 모사하였다.

밀폐식 장치를 사용한 Water+1-Propanol 과 Water+2-Propanol의 인화점 측정과 계산 (The Calculation and Measurement of Flash Point for Water+1-Propanol and Water+2-Propanol Using Closed Cup Aparatus)

  • 하동명;이성진
    • 에너지공학
    • /
    • 제25권4호
    • /
    • pp.190-197
    • /
    • 2016
  • 인화점은 가연성 액체 용액을 안전하게 취급하기 위한 중요한 성질 중 하나이다. 본 논문에서는 Seta flash 밀폐식 장치를 이용하여 이성분계 용액인 water+1-propanol과 water+2-propanol계의 인화점을 측정하였다. 회귀 분석법을 이용하여 인화점을 계산하였다. 또한 라울의 법칙을 이용하여 인화점을 계산하였고, van Laar 식의 이성분계 파라미터를 최적화시키는 방법을 통해 인화점을 예측하였다. 각 인화점 계산 결과와 측정 결과를 비교하였다. 그 결과, 회귀 분석법에 의한 인화점 계산치가 가장 측정치를 잘 모사하였다.

Seta Flash 밀폐식 장치를 이용한 Water-Methanol과 Water-Ethanol계의 인화점 측정 (The Measurement of Flash Point of Water-Methanol and Water-Ethanol Systems Using Seta Flash Closed Cup Tester)

  • 하동명;박상훈;이성진
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.39-43
    • /
    • 2015
  • 인화점은 액체 혼합물의 화재와 폭발의 위험성을 특징짓는 주된 성질이다. 인화점은 가연성 액체에 불꽃이 가해졌을 때 점화가 발생하는 가장 낮은 온도로 정의된다. Seta flash 밀폐식 장치를 이용하여 이성분계 수용성 혼합물인 water-methanol계와 water-ethanol계의 인화점을 측정하였다. Wilson 식과 UNIQUAC 식과 같은 활동도 모델식을 활용한 방법을 이용하여 인화점을 계산하였다. 이 계산치와 라울의 법칙에 의한 계산치를 비교하였다. 그 결과, 활동도 계수 모델식에 의한 계산치가 라울의 법칙에 의한 계산치 보다 측정값에 보다 근접하였다.

SWAT 모형의 매개변수와 유역의 지형학적 특성 관계 (The Relationship between Parameters of the SWAT Model and the Geomorphological Characteristics of a Watershed)

  • 이웅희;이지행;박지훈;최흥식
    • Ecology and Resilient Infrastructure
    • /
    • 제3권1호
    • /
    • pp.35-45
    • /
    • 2016
  • 섬강 시험유역의 지형학적 특성 매개변수와 SWAT-CUP의 SUFI-2 알고리즘을 이용한 SWAT 모형 매개변수와의 상관관계와 이들의 관계식을 개발하였다. 개발한 상관 관계식을 이용하여 속사천 유역의 SWAT 모형의 매개변수를 추정하였다. 아울러, 속사천 유역의 2000 - 2007년의 강우-유출 자료를 대상으로 SWAT-CUP의 SUFI-2 알고리즘을 이용하여 SWAT 모형의 매개변수를 추정하였다. 개발한 식에 의해 산정한 각 매개변수의 적용성을 검토하기 위해 2000 - 2007년의 속사천 시험유역 자료를 이용하여 SWAT 모형의 유출모의를 실시하였다. 실측자료와 지형학적 특성 매개변수의 상관관계 분석으로 산정된 매개변수를 이용하여 속사천에 적용한 유출 모의결과와의 RMSE (root mean square error)는 $1.09m^3/s$이고, SWAT-CUP의 SUFI-2 최적 매개변수를 적용한 유출 모의결과와의 RMSE는 $0.93m^3/s$으로 나타났다. 따라서 지형학적 특성 매개변수를 이용한 SWAT 모형의 매개변수 추정이 적용성이 있다고 판단된다.

건설산업관리(CM)에서 안전관리정보시스템 구축 모델에 관한 연구 (A Study on the Setup Model of Safety Management Information System in the Construction Management)

  • 김영수;강경식
    • 대한안전경영과학회지
    • /
    • 제5권3호
    • /
    • pp.45-55
    • /
    • 2003
  • Construction Management(CM) system, which was introduced some years ago to large national construction projects, such as the construction of Incheon New Airport, construction of high-speed railroad and World Cup stadiums, is considered to be still in its early stage and safety at each step of CM is very poorly controlled. In an attempt to improve such inferior safety control of domestic CM, this study analyzed safety control operation system in CM home and abroad and suggested a model for the construction of safety control management information system suitable to the conditions of Korea.