• 제목/요약/키워드: Safety Apparatus

검색결과 328건 처리시간 0.025초

전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구 (A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus)

  • 장한솔;정우령;문정현;최성경;성원석;황민섭;이승덕;김경호;윤종화;김은정
    • 대한한의학회지
    • /
    • 제43권3호
    • /
    • pp.150-163
    • /
    • 2022
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

비점화(非點火)(Non-Incendive)형(型) 방폭(防爆) 전기기기(電氣機器)의 구조특성(構造特性) 및 평가방법(評價方法) (Constructional Properties and Evaluation Methods of the Non-Incendive Type of Explosion-Proof Electrical Apparatus)

  • 최상원;이관형;문정기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.110-113
    • /
    • 1994
  • In the hazardous areas where explosive substances in the form of gases, vapor or mists exist, electrical apparatus and installations must be of explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, six types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, and special types. If electrical apparatus are made of explosion-proof construction in a way other than five above-mentioned types, and their performance is tested and approved by the reponsible authorities, they may be categorized as special type apparatus. In this paper, we introduced a special type of explosion-proof electrical apparatus, called non-incendive type, and presented its constructional requirements. We also investigated evaluation methods of non-incendive type apparatus to assure the explosion-proof performance, and proposed a new classification method of hazardous areas using probabilistic concept.

  • PDF

스마트폰을 활용한 근로자 안전활동 감지장치 개발 및 특성 (Development and Its Characterization of a Worker's Safety Activity Detection Apparatus using Smart Phone)

  • 최상원
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.20-25
    • /
    • 2015
  • It is predicted the mass retirement of the post-war generation and the lack of young people according to reduces the recruitment. Therefore, industry fields are concerned by the low level of occupational safety and health from issued problem in a variety of industries; the charge of expanding business range/multi-functional, black box of technology, difficulty of systematic training, relative decrease in the skill of workers, loss of know-how in the field of information followed restricted site information. In response to these problems, it is necessary to establish the long-termly and actively based on for the adoption of a safety and health management techniques utilizing IT, which is digital assistant(tablet PC, PDA, etc.), RFID/USN/ICT, database systems, and etc. In this study, we developed and evaluated a worker's safety sensing apparatus using smart phone. The apparatus may be useful to prevent accidents in the construction industry as well as confined space work.

적외선 열화상을 이용한 수전설비 온라인 감시 (On-Line Monitoring of Power Apparatus with Infrared Thermography)

  • 임용배;정승천
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.441-444
    • /
    • 2004
  • Each electrical apparatus radiates various infrared as the condition of surface and load current. Because heat distribution of the apparatus changes as the condition, it is able to analyze the condition of the apparatus by using the distribution. However, methods having been used to measure the heat distribution cannot compare normal condition with abnormal, and the apparatus has diagnosed by intuition. This paper deal with a program that is able to analyze changed temperature distribution. The program is to analyze temperatures on pixels in selected region of interest or position and is able momently and logically to analyze condition of the apparatus. The results are able to apply to a on-line monitoring system.

  • PDF

방전전극 재질과 최소점화에너지에 관한 실험 연구 (An Experimental Study on the Minimum Ignition Energy in Low Voltage Spark Discharge by Electrode Material)

  • 최상원
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.63-70
    • /
    • 2012
  • In the hazardous areas where explosive gases, vapor or mists exist, electrical apparatus and installations must be the explosion-proof construction to prevent or limit the danger of the ignition of potentially explosive atmosphere. In Korea, nine types of protection have been specified in the government regulations at present: flameproof enclosure, pressurization, oil immersion, increased safety, intrinsic safety, non-incendive, powder filling, encapsulation, and special types. Among these types, the intrinsic safety has the construction which limit or by-pass igniting the electric energy using electronic devices. This type has lots of merits but at the same time requires a high-degree of technology. In this paper, we investigated several dominating factors which affect the minimum ignition energy; this energy plays a very important role in design and evaluation of the intrinsic safety type electrical apparatus. Electrode material, which is one of the most important factors, was intensively studied for the five sorts of material(Al, Cd, Mg, Sn, and Zn) with performing experiment in a low-voltage inductive circuit using IEC-type(International Electro-technical Commission) spark apparatus. The experimental results show that the minimum ignition energy of electrode material is varied: highest in Cd and lowest in Sn. We also confirmed the effect of electrode make-and-break speed.

erratum : 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구 (erratum : A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus)

  • 장한솔;정우령;문정현;최성경;성원석;황민섭;이승덕;김경호;윤종화;김은정
    • 대한한의학회지
    • /
    • 제44권1호
    • /
    • pp.128-128
    • /
    • 2023
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

적외선 열화상 카메라를 이용한 수전설비 온도분포해석 (The Analysis of Temperature Distribution Electric incoming Apparatus Using a Infrared Thermal Imaging System)

  • 정승천;임용배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1113-1116
    • /
    • 2004
  • This paper presents the method for analyzing surface temperature of Electric incoming Apparatus. For the experiment, the surface temperature of electric power apparatus was measured and analyzed by using a infrared thermal imaging system. Surface Discharges(SD) have very complex characteristics of discharge patterns, therefore it requires the development of precise analysis methods. recently, studies on infrared thermal imaging system are carried out to analyze temperature distribution of power equipments through condition diagnosis and to diagnose the degradation of power equipments. The changes in suface temperature was measured by using the infrared thermal imaging system under hot line condition. The system was set up based on the diagnostic method of the electric incoming apparatus.

  • PDF

이동정보 기록장치를 이용한 전철 계단 피난평가 연구 (Performance Evaluation of Evacuation in Subway Station Stairs using Movement Recording Apparatus)

  • 김영길;김응식
    • 한국안전학회지
    • /
    • 제33권6호
    • /
    • pp.123-127
    • /
    • 2018
  • Recent catastrophic accidents at the underground subway stations in South Korea have proven that the subway evacuation is an important safety concern. Previous studies have used commercial programs for safety assessment or have been focused on development of computing algorithms rather than the basic analysis data which form the foundation of studies. In this study, we designed a new movement recording apparatus which measured and analyzed crowd movements including but not limited to moving velocity, specific flow rate and crowd density. Moreover, We propose new effective analysis method for evacuation studies with this apparatus.

석면분석 정도관리용 표준시료 개발연구 I - 석면분석 정도관리용 표준시료 제조장치 개발 및 시료제조 방법 확립 - (Development of Asbestos Quality Control Sample for Proficiency Analytical Testing 1 - Development of Manufacturing Apparatus and Sample Preparing Procedure for Asbestos Quality Control Sample -)

  • 이광용;이종한;정시정;박두용
    • 한국산업보건학회지
    • /
    • 제19권2호
    • /
    • pp.81-87
    • /
    • 2009
  • Final purpose of this study was designed to develop the quality control(QC) sample for proficiency analytical testing of asbestos. This study consisted of two parts; first, development of manufacturing apparatus and sample preparing procedure for asbestos quality control(QC) sample: second, validation of the QC samples made by our developed method as asbestos proficiency analytical testing sample. The main results of the first part research are as followed We developed the apparatus for manufacturing the asbestos QC sample, consisted of filter hold, filter holder manifolder, vacuum system, and vacuum pump. The most proper filter of making the QC samples was a cellulose ester membrane filter with 25 mm diameter, pore size 0.8 um. And we presented the optimal procedure for preparing the asbestos QC sample by using the developed apparatus. We will verify the manufactured asbestos QC samples by this method, and present the validation results to confirm the reliability as a asbestos QC sample in next paper.