Evaluation of Efficiency of SVE from Lab-scale Model Tests and Numerical Analysis (실내모형시험과 수치해석을 통한 SVE의 효율성 평가)

  • Suk, Heejun;Seo, Min Woo;Ko, Kyung-Seok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1B
    • /
    • pp.137-147
    • /
    • 2008
  • Soil Vapor Extraction (SVE) has been extensively used to remove volatile organic compounds (VOCs) from the vadoze zone. In order to investigate the removal mechanism during SVE operation, laboratory modeling experiments were carried out and tailing effect could be observed in later stage of the experiment. Tailing effect means that removal rate of contaminants gets significantly to decrease in later stage of SVE operation. Also, mathematical model simulating the tailing effect was used, which considers rate-limited diffusion in a water film during mass transfer among gas, liquid, and solid phases. Measurement data obtained through the experiment was used as input data of the numerical analyses. Sensitivity analysis was performed to examine the effect of each parameter on required time to reach final target concentration. Finally, it was found that the concentration in the soil phase decreased significantly with a liquid and gas diffusion coefficient larger, actual path length shorter, and water saturation smaller.

Removal of diesel hydrocarbons by microwave-enhanced soil vapor extraction (Focused on Loss and Kinetic constant for Diesel Hydrocarbons)

  • 김종운;박갑성
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.223-226
    • /
    • 2004
  • In this paper, removal of diesel hydrocarbons (C$_{10}$-C$_{22}$) for dry and moist soil was investigated so that microwave-enhanced soil vapor extraction(SVE) reduced soil treatment time and raised remediation efficiency. Kinetic constants of diesel hydrocarbons with microwave energy were 7 times on dry soil and 1580 times on moist soil as much as those of SVE process without microwave energy. The diesel removals were 67.7~78.4% for $C_{10}$ and $C_{12}$, and 0~18.5% for $C_{14}$~C$_{22}$ for dry and moist soil with SVE process only. On the other hand, dry soil with microwave-enhanced SVE process showed 89.3~99.4% removal for $C_{10}$ and $C_{12}$ and 35.6~67.0% for hydrocarbons over $C_{14}$. All hydrocarbons(C$_{10}$~C$_{22}$) studied were significantly removed (93.6~99.8%) for moist soil with microwave-enhanced SVE process. Almost all diesel hydrocarbons were usually considered as semi-volatile compounds(SVOCs). Microwave-enhanced SVE process might have a great potential for remediation of soils contaminated with SVOCs.OCs.

  • PDF

Application of Enhanced Soil Vapor Extraction Using PVDs (연직배수재를 이용한 토양증기추출법의 적용)

  • Shin, Eun-Chul;Park, Jeong-Jun;Kim, Jong-In;Choi, Min-Guen
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.10a
    • /
    • pp.382-388
    • /
    • 2005
  • Soil vapor extraction(SVE) is an effective and cost efficient method of removing volatile organic compounds(VOCs) and petroleum hydrocarbons from unsaturated soils. However, soil vapor extraction becomes ineffective in soils with low gas permeability, for example soils with air permeabilities less than 1 Darcy. Prefabricated vertical drains(PVDs) have been used for dewatering fine-grained soils for more than 25 years. Incorporating PVDs in and SVE system can extend the effectiveness of SVE to lower permeability soils by shortening the air flow-paths and ultimately expediting contaminant removal. The objective of the work described herein was to effectively incorporate PVDs into a SVE remediation system and to demonstrate a PVDs enhanced SVE system at full scale. The finding from this research will facilitate the design of field PVD-SVE systems in terms by providing insight into the optimal spacing between PVDs, the radius of influence of the wells and the flow rates to be used to capture and extract gas phase contaminants.

  • PDF

SVE & Bioventing Techniques for the Treatment of Hydrocarbon (SVE와 Bioventing 기술을 이용한 유류 오염토양의 복원)

  • 김무훈;강순기;조미영;정우성;박덕신
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.137-140
    • /
    • 2000
  • The purpose of this study is to see the effect of SVE (Soil Vapor Extraction) and Bioventing (biostimulation) hydrocarbon contaminated areas. The removal rate of VOC for three weeks were 17.43 kg on 3.6 ㎥/hr at steady-state. In the application of Bioventing, every flow rate were tested, and it was found that 4.0 ㎥/hr were adequate for best control of the system. At this stage, the addition of microbial agent accelerated the biodegradation of the hydrocarbon.

  • PDF

Remediation of the Diesel Contaminated Soils Using Thermally Enhanced Soil Vapor Extraction Process with Microwave Heating (마이크로웨이브 가열 토양증기추출 공정에 의한 경유 오염 토양처리)

  • 김종운;박갑성
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.1
    • /
    • pp.39-46
    • /
    • 2004
  • Removal efficiencies for diesel fuel and diesel hydrocarbons ($C_10$$C_22$) using microwave-enhanced SVE process were evaluated with dry and moist soil, respectively. Diesel removal rates of microwave-enhanced SVE process were 7 times for dry soil and 1580 times for moist soil as great as those of the SVE process without microwave heating. High dielectric property of water contents may accelerate the absorption of microwave energy into soil and thus vaporized the diesel fuel components drastically. The diesel removals were 67.7∼78.4% for $C_10$ and $C_12$, and 0∼18.5% for $C_14$$C_22$ for dry and moist soil with SVE process only. On the other hand, dry soil with microwave-enhanced SVE process showed 89.3∼99.4% removal for $C_10$ to and $C_12$ and 35.6∼67.0% for hydrocarbons over $C_14$. All hydrocarbons ($C_10$$C_22$) studied were significantly removed (93.6∼99.8%) for moist soil with microwave-enhanced SVE process.

The Study on the Remediation of Contaminated Soil as TPH using SVE and Bioremediation (SVE 및 생물학적 공법을 이용한 TPH 오염토양처리에 관한 연구)

  • Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.17 no.1
    • /
    • pp.97-105
    • /
    • 2008
  • This study examined the contaminated soils with an indicator of TPH using SVE (Soil Vapor Extraction) and biological treatments. Their results are as follows. Water content in the polluted soils slowly decreased from 15% during the initial experimental condition to 10% during the final condition. Purification of polluted soils by Bioventing system is likely to hinder the microbial activity due to decrease of water content. Removal rate of TPH in the upper reaction chamber was a half of initial removal rate at the 25th day of the experiment. The removal rate in the lower reaction chamber was 45% with concentration of 995.4 mg/kg. When the Bioventing is used the removal rate at the 14th day of the experiment was 53%, showing 7 day shortenting. Since the Bioventing method control the microbial activity due to dewatering of the polluted soil, SVE method is likely to be preferable to remove in-situ TPH. The reactor that included microbes and nutrients showed somewhat higher removal rate of TPH than the reactor that included nurtients only during experimental period. In general, the concentration showed two times peaks and then decreased, followed by slight variation of the concentration in low concentration levels. Hence, in contrast to SVE treatment, the biological treatment tend to show continuous repetitive peaks of concentration followed by concentration decrease.

Remediation for Gasoline Contaminated Soils with SVE (soil vapor extraction) Including a Post-treatment System of Extraction Gases (배출가스의 후처리 공정을 포함한 토양증기추출법을 이용한 가솔린 오염 토양 복원)

  • 이민희;강현민;이병헌;빈정인
    • Journal of Soil and Groundwater Environment
    • /
    • v.9 no.2
    • /
    • pp.28-40
    • /
    • 2004
  • Box experiments were performed to evaluate the removal efficiency of SVE (soil vapor extraction) for gasoline in soil. An activated carbon sorption tower and a biofilter were operated as post-treatment processes to remove VOCs extracted from extraction wells of SVE. An acrylic resin box (65 cm${\times}$20 cm${\times}$30 cm) was used to make artificial soil layers and two injection wells and one extraction well were built for SVE process in the box. Gases from extraction wells flew into the activated carbon sorption tower or the biofilter. Gasoline concentrations of VOCs emitted from the extraction well were compared with those after post treatments. More than 92% of initial gasoline mass in soil were removed by SVE within few days, suggesting that SVE is very available to remove VOCs from contaminated soils. To treat VOCs from extraction wells of SVE, an activated carbon sorption tower and a biofilter were attached to SVE process and their gasoline removal efficiencies were measured. These post treatment systems lowered gasoline concentrations to below 1.0 ppm within few days. Average remediation efficiency was 98% of gasoline for the activated carbon sorption tower and 84.1% for the biofilter. The maximum removal capacity of a biofilter was 10.7 g/L/hr, which was ten times higher than general biofilter removal capacity. Results from the study suggest that the activated carbon sorption tower and the biofilter would be available for the post treatment process to remove VOCs generated from SVE process.

A Study on Air Permeability and Radius of Influence During SVE/Bioventing (SVE/Bioventing시 토양의 투기계수 및 영향반경에 관한 연구)

  • 이철효;장원용;전연호;이진용;이강근
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.24-31
    • /
    • 2000
  • Soil air permeability and influence of radius in air injection/extraction tests were estimated. These are important factors in the determination of optimal design for SVE or bioventing system. For evaluation of the effects of air leakage from the ground surface on those factors, Theis (1935) and Hantush (1960) methods were used in the data analysis. The air permeability of the studied area was in the range of 1.64$\times$$10^{-7}$~5.66$\times$$10^{-6}$ $\textrm{cm}^2$, and this result would be used for the design of SVE or bioventing system.

  • PDF

Assessment of Environmental Impacts and $CO_2$ Emissions from Soil Remediation Technologies using Life Cycle Assessment - Case Studies on SVE and Biopile Systems - (전과정평가(LCA)에 의한 토양오염 정화공정의 환경영향분석 및 $CO_2$ 배출량 산정 - SVE 및 Biopile 시스템 중심으로 -)

  • Jeong, Seung-Woo;Suh, Sang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.267-274
    • /
    • 2011
  • The environmental impacts of 95% remediation of a total petroleum hydrocarbon-contaminated soil were evaluated using life cycle assessment (LCA). LCA of two remediation systems, soil vapor extraction (SVE) and biopile, were conducted by using imput materials and energy listed in a remedial system standardization report. Life cycle impact assessment (LCIA) results showed that the environmental impacts of SVE were all higher than those of biopile. Prominent four environmental impacts, human toxicity via soil, aquatic ecotoxicity, human toxicity via surface water and human toxicity via air, were apparently found from the LCIA results of the both remedial systems. Human toxicity via soil was the prominent impact of SVE, while aquatic ecotoxicity was the prominent impact of biopile. This study also showed that the operation stage and the activated carbon replacement stage contributed 60% and 36% of the environmental impacts of SVE system, respectively. The major input affecting the environmental impact of SVE was electricity. The operation stage of biopile resulted in the highest contribution to the entire environmental impact. The key input affecting the environmental impact of biopile was also electricity. This study suggested that electricity reduction strategies would be tried in the contaminated-soil remediation sites for archieving less environmental impacts. Remediation of contaminated soil normally takes long time and thus requires a great deal of material and energy. More extensive life cycle researches on remedial systems are required to meet recent national challenges toward carbon dioxide reduction and green growth. Furthermore, systematic information on electricity use of remedial systems should be collected for the reliable assessment of environmental impacts and carbon dioxide emissions during soil remediation.

SVE 및 미생물제제를 이용한 유류 오염토양의 현장 복원

  • 박영준;염규진;김선미;이문현;박광진;이영신
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.103-106
    • /
    • 2003
  • This study was conducted to evaluate in-situ bioremediation ability of Bioil-D, microbial material for oil degradation, at a gas station that had been treated by SVE system. TPH concentrations and total contaminated soil volume were rapidly decreased after Bioil-D treatment. The performance of Bioil-D was also estimated based on the observation of microbial population at the soil samples and $CO_2$ concentration produced at the extraction wells. The field study showed a successful work of Bioil-D.

  • PDF