• 제목/요약/키워드: SV-8

검색결과 314건 처리시간 0.027초

Selective Stimulating Effect of Flavonoids on the Antioxidant Defense System in Normal and Transformed Hepatic Cell Lines

  • Kim, Beom-Tae;Lee, Jeong-Chae
    • Natural Product Sciences
    • /
    • 제10권6호
    • /
    • pp.296-301
    • /
    • 2004
  • Previously, a flavonoid fraction, which consisted mainly of protocatechuic acid, fustin, fisetin, sulfuretin, and butein, here named RCMF $({\underline{R}}VS\;{\underline{c}}hloroform-{\underline{m}}ethanol\;{\underline{f}}raction)$, was prepared from a crude acetone extract of Rhus verniciflua Stokes (RVS) which is traditionally used as a food additive and as an herbal medicine. In this study, we evaluated the effects of RCMF on the antioxidant defense system using embryonic normal hepatic cell line (BNL CL.2) and its SV40-mediated transformed cell line (BNL SV A.8). This study demonstrates that RCMF selectively stimulated the antioxidant defense system of normal cells, as BNL CL.2 cells proved to be more sensitive to RCMF-mediated increases of superoxide dismutase, catalase, glutathione, and glutathione reductase than BNL SV A.8 cells. In particular, RCMF caused a significant increase in the malonaldehyde content of BNL SV A.8 cells, which is believed to be closely associated with cytotoxicity of RCMF and RCMF-mediated growth inhibition. Collectively, our findings suggest that the flavonoid fraction, RCMF, selectively stimulates the antioxidant defense system in normal rather than hepatic tumor cells.

핵의학 방사선 작업종사자 피폭 감소 방안에 대한 연구 (A Study on Reduction of Radiation Exposure by Nuclear Medicine Radiation Workers)

  • 이왕희;안성민
    • 한국방사선학회논문지
    • /
    • 제13권2호
    • /
    • pp.271-281
    • /
    • 2019
  • 본 연구는 다양한 종류의 차폐체가 가진 차폐 효율을 확인하고, 인체모형 팬텀을 활용해 깊이에 따른 장기별 선량을 측정한 것이다. 개인방사선량측정기를 이용한 차폐체 차폐효율 측정 결과 다양한 차폐체 중 나노텅스텐으로 구성된 1.1 mm RNS-TX가 가장 높은 차폐 효율을 보였고, 0.2 mm 납 차폐체가 가장 낮은 차폐 효율을 보였다. $^{99m}Tc$ 30 mCi를 120분 동안 팬텀에 노출시킨 뒤 장기가 받은 선량 측정 결과. 방사선 방호복을 착용하지 않은 경우, 0.25 mm Pb, 0.5 mm Pb 방호복을 착용한 경우, 장기의 평균 선량은 각각 20.53 mSv, 8.75 mSv, 6.03 mSv로 나타났다. $^{131}I$ 2 mCi를 120분 동안 팬텀에 노출시킨 뒤 장기가 받은 선량 측정 결과, 방사선 방호복을 착용하지 않은 경우, 0.25 mm Pb, 0.5 mm Pb 방호복을 착용한 경우, 장기의 평균 선량은 각각 7.71 mSv, 4.88 mSv, 2.79 mSv로 나타났다. $^{18}F$ 5 mCi를 120분 동안 팬텀에 노출 시킨 뒤 장기가 받은 선량 측정 결과. 방사선 방호복을 착용하지 않은 경우, 0.25 mm Pb, 0.5 mm Pb 방호복을 착용한 경우, 장기의 평균 선량은 각각 16.39 mSv, 15.84 mSv, 12.52 mSv로 나타났다. 핵의학 작업종사자의 피폭선량이 한도를 넘지 않는다고 하더라도, 병원 내 타 직군 종사자와 비교 했을 때, 상대적으로 높은 피폭선량을 보이므로 가볍고 차폐효율이 좋은 차폐물질로 개발된 방사선방호복 착용, 순환 업무, 업무 분담, 오토분주기와 같은 대체 장비 도입 등을 통해 핵의학 작업종사자의 선량을 줄이고, 관리할 수 있어야 한다.

방사선사의 지역별 피폭선량에 관한 연구 (A Study on Regional Irradiation Dose of Radiological Technologists)

  • 정홍량;김정구
    • 한국콘텐츠학회논문지
    • /
    • 제5권5호
    • /
    • pp.281-286
    • /
    • 2005
  • 전국 16개 시도의 44개 종합병원에서 근무하는 방사선사 623명을 대상으로, 1998년부터 2002년도까지의 5년간 병원 방사선사의 피폭선량을 2003년 7월부터 8월까지 조사했다. 조사된 방사선사의 연간 평균피폭선량은 $1.73{\pm}0.10mSv$로 나타났다. 연도별로 보면 2000년이 $1.80{\pm}0.15mSv$로 가장 높고, 1998년이 $1.36{\pm}0.12mSv$로 가장 낮은 것으로 나타났다. 그러나 병원의 방사선피폭 환경에 근무하는 방사선사는 직업상 만성피폭이 될 가능성이 있으므로 이에 대한 장기적인 대안이 제시되어야 할 것으로 사료된다.

  • PDF

Characteristics of GMR-SV Sensor for Measurement of Mineral Contents in Edible Water

  • Kim, Da-Woon;Lee, Ju-Hee;Kim, Min-Ji;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • 제14권2호
    • /
    • pp.80-85
    • /
    • 2009
  • The mineral dissolution sensor system using GMR-SV and glass/Mg(200 nm) was prepared and characterized. The magnetic field sensitivity of GMR-SV to microscopic magnetic variation was about 0.8%/Oe. The change that occurs when Mg-film dissolves in water, the solubility of water, which is one of the basic properties of mineral water, was sensed by measuring the subtle variation of an electric current. In the case of edible water with Mg mineral added, bubbles were generated on the surface of the Mg film in the first 45 minutes, and the number of drops that were dissolved more rapidly than with the tap and DI waters later reduced to zero. For the edible water samples that each had different mineral Mg concentrations, the Mg solubility speed significantly differed. After injecting Mg film into the edible water, the magnetoresistance of the output GMR-SV signal decreased from a maximum of $45.4\;{\Omega}$ to a minimum of $43.6\;{\Omega}$. The measurement time was within 1 min, giving the rate of change ${\Delta}R/{\Delta}t=0.18\;{\Omega}/s$. This measurement system can be applied to develop a mineral Mg solubility GMR-SV sensor that can be used to sense the change from edible water to reduced alkali.

두부규격방사선사진 촬영시 주요 장기의 등가선량, 유효선량 및 위험도 (EQUIVALENT DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM CEPHALOMETRIC RADIOGRAPHY TO CRITICAL ORGANS)

  • 강성숙;조봉혜;김현자
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.309-318
    • /
    • 1995
  • In head and neck region, the critical organ and tissue doses were determined, and the risks were estimated from lateral, posteroanterial and basilar cephalometric radiography. For each cephalometric radiography, 31 TLDs were placed in selected sites(18 internal and 13 external sites) in a tissue-equivalent phantom and exposed, then read-out in the TLD reader. The results were as follows: 1. From lateral cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland(3.6pSv) and the next highest dose was that received by the bone marrow(3pSv). 2. From posteroanterial cephalometric radiography, the highest effective dose recorded was that delivered to the salivary gland(2pSv) and the next highest dose was that received by the bone marrow(1.8pSv). 3. From basilar cephalometric radiography, the highest effective dose recorded was that delivered to the thyroid gland(31A p Sv) and the next highest dose was that received by the salivary gland(13.3 p Sv). 4. The probabilities of stochastic effect from lateral, posteroanterial and basilar cephalometric radiography were $0.72{\times}10^{-6}$, $0.49{\times}10^{-6}$ and $3.51{\times}10^{-6}$, respectively

  • PDF

일부 생활용품에서 발생한 공기 중 라돈과 토론의 발생 특성 및 연간 유효선량 추정 (Effective Doses Estimated According to Characteristics of Airborne Radon and Thoron Levels Generated from Some Household Products)

  • 박동욱;이성진;김소연;곽현석;이승희;박지훈
    • 한국환경보건학회지
    • /
    • 제45권2호
    • /
    • pp.99-112
    • /
    • 2019
  • Objective: This study aims to analyze the characteristics of airborne radon and thoron level ($Bq/m^3$) generated from household products containing monazites, and estimate the effective doses (mSv/yr). Method: Radon & Thoron detector EQF3220 was used to monitor real-time airborne radon and thoron level ($Bq/m^3$), and their daughters ($Bq/m^3$) were recorded every two hours. Effective doses (mSv/yr) for radon and thoron were estimated according to models developed by International Commission on Radiological Protection (ICRP) and United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR). Results: The average levels of radon and thoron were $87.8Bq/m^3$ (range; $20.8-156.3Bq/m^3$) and $1,347.5Bq/m^3$ (range; $4-5,839.7Bq/m^3$), respectively. The average equilibrium factors (F) were 0.23 and 0.007, respectively. The levels of radon progeny were far higher than that thoron. Latex mattress showed the highest F (0.38). The average effective doses were estimated to be ICRP (1.9 mSv/yr) and UNSCER (1.3 mSv/yr) for radon and UNSCEAR (1.6 mSv/yr) for thoron. Conclusions: Our results have far exceeded the allowable effective dose for general population (1 mSv/yr). The government's actions such as the ban of use of consumer products containing monazite and the establishment of surveillance system to evaluate health effects for the people affected should be taken as early as possible.

복부직경에 따른 CT유효선량 및 화질변화 비교 분석 (A Comparison Analysis of CT Effective Dose and Image Quality according to Abdominal Diameter)

  • 윤준;김현주
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.821-826
    • /
    • 2018
  • 본 연구는 경기도 소재 대학병원에 2018년 1월1일부터 2018년 6월30일까지 복부 CT검사를 위해 내원한 모든 환자의 영상 중 무작위로 선정하여 복부 면적의 크기 별로 20명 씩 60명을 총 3군으로 분류하여 복부 CT영상의 면적에 따른 유효선량과 화질의 변화정도를 알아보았다. 그 결과 평균면적 군 에서 유효선량이 7.34 mSv로, 평균면적이상 군은 8.39 mSv, 평균면적이하 군은 5.89 mSv로 측정 되었다. 화질분석을 위해 복부면적에 따라 동일한 3영역에 ROI를 그려 비교해본 결과 3군으로 분류한 복부면적에서 모두 CT value가 유의한 차이가 있는 것으로 분석되었다(p<0.05). 향후 실제 임상에서 적용할 수 있는 프로토콜을 개발 시 본 연구결과를 기초자료로 활용할 수 있을 것으로 사료되며 현재 임상에서 CT검사 시 적용하고 있는 다양한 선량감소 프로그램을 적용 및 복부 면적 외 다양한 환자의 변환 조건 등을 고려하여 연구와 고찰을 도출한다면 화질과 피폭선량 감소에 도움을 줄 수 있을 것으로 사료된다.

중증외상환자의 전산화단층촬영 및 중재술에 의한 방사선 유효선량 및 생애 귀속위험도 (Effective Radiologic Doses and Lifetime Attributable Risks in Patients with Trauma Critical Pathway Activation)

  • 이원효;공태영;김승환;유제성;박유석;이재길;정성필
    • Journal of Trauma and Injury
    • /
    • 제26권3호
    • /
    • pp.198-206
    • /
    • 2013
  • Purpose: This study was performed to calculate and analyze the effective radiation doses from computed tomography (CT) and radiologic intervention in patients in the emergency department (ED) with trauma critical pathway (CP) activation and further to estimate the lifetime attributable risks (LARs) for the incidence of and mortality from cancers induced by the radiation dose. Methods: Through a retrospective electrical chart review of 104 injured patients who trauma critical pathway were activated from November 2012 to March 2013, we calculated effective radiologic doses by taking the product of the dose-linear product of the scan and the conversion coefficient. After a determination of the image results, we divided the patients into two groups, negative or positive, and calculated the effective dose for each group. With these results, we estimated the LARs for the incidence of and the mortality from cancers by using the table in the Biologic Effects of Ionizing Radiation (BEIR)-VII report. Results: A total of 76 patients were enrolled. The mean age was $49.0{\pm}8.5$ years. The mean injury severity score (ISS) was $12.7{\pm}8.4$. The cumulative effective dose (CED) for individual patients varied from 2.8 mSv to 238.8 mSv, and the mean was $47.6{\pm}39.9$ mSv. The CED in patients with an $ISS{\geq}16$($63.2{\pm}26.6$ mSv) was higher than that of patients whose ISS<16($33.5{\pm}23.1$ mSv) (p<0.001). The CED in patients who were treated with surgery or intervention($69.0{\pm}45.2$ mSv) was higher than that of patients who were treated conservatively($33.6{\pm}22.4$ mSv) (p<0.001). The LARs for cancer incidence and mortality were $328.5{\pm}308.6$ and $189.0{\pm}159.3$ per 100,000 people, respectively. Conclusion: The CED and the LAR for trauma CP-activated patients in the ED were significant, so efforts should be made to decrease the effective dose received by severely injured patients.

Using 2-mSv Appendiceal CT in Usual Practice for Adolescents and Young Adults: Willingness Survey of 579 Radiologists, Emergency Physicians, and Surgeons from 20 Hospitals

  • Hyuk Jung Kim;Kyoung Ho Lee;Min-Jeong Kim;Sung Bin Park;Yousun Ko;LOCAT Group
    • Korean Journal of Radiology
    • /
    • 제21권1호
    • /
    • pp.68-76
    • /
    • 2020
  • Objective: To survey care providers' willingness to use 2-mSv computed tomography (CT) in their usual practice for adolescents and young adults with suspected appendicitis. Materials and Methods: An ethical committee approved this prospective study. We introduced 2-mSv CT in 20 hospitals through a pragmatic clinical trial. At the final phase of the trial, we invited 698 potentially-involved care providers in the survey regarding their willingness to use 2-mSv CT. Multivariable logistic regression analyses were performed to identify factors associated with willingness. Nine months after the completion of the trial patient recruitment, we surveyed whether the hospitals were using 2-mSv CT in usual practice. Results: The analyses included responses from 579 participants (203 attendings and 376 trainees; 221 radiologists, 196 emergency physicians, and 162 surgeons). Regarding the willingness to immediately change their standard practice to 2-mSv CT, 158 (27.3%), 375 (64.8%), and 46 (7.9%) participants responded as "yes" (consistently), "partly" (selectively), and "no", respectively. Willingness varied considerably across the hospitals, but only slightly across the participants' departments or job titles. Willingness was significantly associated with attendings (p = 0.004), intention to maintain the dedicated appendiceal CT protocol (p < 0.001), belief in compelling evidence on the carcinogenic risk of conventional-dose CT radiation (p = 0.028), and hospitals having more than 1000 beds (p = 0.031). Fourteen of the 20 hospitals kept using 2-mSv appendiceal CT in usual practice after the trial. Conclusion: Despite the extensive efforts over the years of this clinical trial, many care providers were willing to use 2-mSv CT selectively or not willing to use.

감마선분광분석기를 이용한 괴산 옥천하부천매암대 일대의 감마선량 평가 (Assessment of Gamma-radiation dose Rate in the Ogcheon Lower Phyllite Area, Goesan County, Korea, Using Gamma-ray Spectrometry)

  • 윤욱;조병욱
    • 지질공학
    • /
    • 제29권4호
    • /
    • pp.461-468
    • /
    • 2019
  • 휴대용 감마선분광분석기를 이용하여 괴산지역 옥천하부천매암대(og2) 주변 일대 77개 지점에서 감마선량을 측정하였다. 전체 시료의 40K 함량은 1.8-8.8% 범위(평균 4.6%)로 Kgr에서 함량이 가장 높았으 며, eU의 함량 범위는 0.2-217.9 ppm (평균 16.7 ppm)인데 og2에서 가장 높았으며(중앙값 29.6 ppm)다. eTh의 함량 범위는 11.9-76.5 ppm (평균 29.5 ppm) 이었는데 Kgr의 평균 함량은 45.4 ppm으로 og1, og2, og3의 함량(26.6-30.6 ppm)보다 높았다. og2에 속하는 일부 고 우라늄 지점을 제외한 연구지역의 감마선량에 기여하는 방사성물질은 40K가 절대적이다. 연구지역의 옥외 유효선량률은 0.08-1.71 mSv/y (평균 0.28 mSv/y)의 범위로 나타났다. 유효선량률이 1 mSv를 넘는 지점은 함 우라늄 층이 협재된 og2의 덕평리지역 3지점이며 이를 제외한 나머지 대부분 지역은 정상적인 자연방사선지역에 해당한다.