• 제목/요약/키워드: STS304

검색결과 368건 처리시간 0.025초

금속기지 내열 경사기능 복합재료 개발에 관한 연구 (Development of the Heat-Resistant Functionally Gradient Material with Metal Substrate)

  • 김부안;남기우;조문호
    • 한국해양공학회지
    • /
    • 제13권1호통권31호
    • /
    • pp.62-69
    • /
    • 1999
  • 67Ni-22Cr-10Al-1Y and $ZrO_2-8Y_2O_3$ were coated on the substrate surface of ST304 and Al2024 by the plasma spraying method. The adgesion of the films varies depending on the substrates and the laminating method. In the case of STS304, the cracks were observed at thermal shock temperature difference ${Delta}T$ of $900^{circ}C$ in the non functionally gradient material(NFGM) and at $1100^{circ}C$ in the functionally gradient material(FGM). The film adhesion of the FGM is better than that of the NFGM in ST304. The cumulative AE count of the FGM of STS304 increased continuously at the bending test. But the NFGM of STS304 showed discontinuity of the AE count. The total AE count for the FGM of STS304 decreased as the number of thermal shock increased, and this tendency was evident as the thermal shock temperature difference increased.

  • PDF

304 스테인레스강의 고착방지성능 향상을 위한 Sn-Al 열 확산 코팅 기술 개발 (Development of Sn-Al Thermal Diffusion Coating Technology for Improving Anti-Galling Characteristics of 304 Stainless Steel)

  • 황주나;강성훈;조성필;정희종;김동욱;이방희;황준;이용규
    • 한국표면공학회지
    • /
    • 제51권5호
    • /
    • pp.297-302
    • /
    • 2018
  • The important drawback of hardware fasteners consisted of 304 stainless steel (STS) is a frequent galling caused by a combination of friction and adhesion between the sliding surface. To improve the anti-galling effect, Sn-Al coatings by a thermal diffusion have been developed. The thermal diffusion by pack cementation with an $AlCl_3$ activator at $250^{\circ}C$ for 1 hour produced an Sn-Al alloy coating layer with an average thickness of $9.9{\pm}0.5{\mu}m$ on the surface of 304 STS fasteners. Compared with the galling frequency of the 304 STS fasteners, Sn-Al coatings on the surface of 304 STS fasteners demonstrated about 2.8-time reduction of the galling frequency.

이온빔을 이용한 STS304와 알루미나 브레이징 접합효과 (Effects of the Brazing Bonding between Al2O3 and STS304 with an Ion Beams)

  • 박일수
    • 한국산학기술학회논문지
    • /
    • 제16권12호
    • /
    • pp.8679-8683
    • /
    • 2015
  • 세라믹은 고온에서 뛰어난 내마모성, 내부식성을 가지기 때문에 산업적 응용에 있어서 널리 사용된다. 세라믹은 금속과 비교해서 고온에서 더 큰 강도를 가지고 있고, 더 낮은 열전도도 및 열팽창 계수를 가진다. 그러나, 세라믹이 가진 취성의 성질은 전기전자산업과 고온에서의 구조적 적용에의 넓은 적용을 제한한다. Ti 활성금속과 STS304를 IBAD 기술을 이용해서 동시에 증착시켜 STS304 스테인레스강에 $Al_2O_3$(알루미나)의 브레이징 접합강도에 어떤 영향을 미치는지 알아보았으며, 시험편들은 Ti 타겟과 Ti+ STS304 타겟 두 종류를 이용하여 두께를 변화시켜가며 증착하였다. 브레이징 접합을 위한 삽입금속으로는 일반적으로 사용되는 Ag-Cu 공정조성의 합금이 사용되었다. 브레이징 접합품의 강도는 Ag-Cu 삽입금속과 알루미나 사이의 반응층의 두께와 반응 생성물 조직에 의해 결정되며, 본 실험에서는 계면 반응의 메커니즘을 보다 구체화하고 계면 반응에 의한 경사기능성의 접합계면을 더욱 향상시키는 결과를 얻고자 한다.

SM40C와 STS304 이종재료 마찰용접재의 파단특성 및 크랙전파특성의 연구 (A Study on the Rupture and Crack Propagation Dharacteristics in the Material Friction-Welded with Hetrogeneous Steels of SM40C and STS304)

  • 오세욱;허정원;유재환;김재철
    • Journal of Welding and Joining
    • /
    • 제10권4호
    • /
    • pp.230-239
    • /
    • 1992
  • The specimens of two base metals and material friction-welded with hetrogeneous steels of SM40C and STS304 have been prepared and the characteristics of rupture and crack propagation of them have been examined. In the friction-welded material, the width of HAZ is 3.0mm for STS304 and 3.4mm for SM40C. The hardness distribution in HAZ of SM40C is decreased gradually as being getting off interface, but that in HAZ of STS304 is decreased remarkedly and the value of hardness becomes a little lower than that of the base metal in region of 1mm from interface and becomes a little higher than that of the base metal. The tensile strength of the friction-welded material appeared a little lower than that of the base metal and rupture by tensile load is developed in HAZ of STS304 and the position of rupture is at region of low hardness(1mm from interface). The crack propagation rates(da/dN) in both HAZ of the friction-welded material are a little higher than those in both base metals, but the difference are less except for the case of SM45C in low .DELTA. K value. It has been ascertained that the crack in the interface propagates selectively along the HAZ of SM40C and consequently the crack propagation rate is almost similar to that in the HAZ of SM40C.

  • PDF

가스 냉온수기용 STS 304 배관 용접부의 부식특성에 관한 연구 (The Study on the Corrosion Characteristics of STS 304 Pipeline Steel Weldment for Gas Cooling & Heating System)

  • 김환식;임우조
    • 한국가스학회지
    • /
    • 제11권2호통권35호
    • /
    • pp.31-36
    • /
    • 2007
  • 가스 냉온수기용 STS 304 배관 용접부의 부식특성을 연구하기 위하여, 0.5M $H_2SO_4+0.01M$ KSCN 수용액 중에서 전기화학적 분극시험, 금속조직시험 과 경도시험을 실시하여 STS 304배관 용접부의 양극분극거동, 인가전위에 따른 부식거동, 용접부의 금속조직 및 경도거동를 고찰하였다. 다음과 같은 결론을 얻었다. 1) 임계양극전류밀도는 모재보다 용접열영향부에서 많이 배류되고, 기본부동태전위는 모재보다 용접열영향부에서 더 높게 된다. 2) 부동태전류밀도는 모재보다 용접열영향부에서 더 많이 배류되고, 부동태영역은 용접열영향부보다 모재가 더 크게 된다. 3)인가전압에 의한 용접열영향부의 전류밀도는 모재의 전류밀도보다 더 많이 배류된다.

  • PDF

전침 시술시 침 재료에 따른 부식성 평가 (The Corrosiveness Evaluation according to the Needle Material in the Electroacupuncture Operation)

  • 권오상;최광호;조성진;류연희;최선미;이상훈
    • Korean Journal of Acupuncture
    • /
    • 제29권2호
    • /
    • pp.216-223
    • /
    • 2012
  • Objectives : Electroacupuncture is widely used because of its diverse curative influence. However, its electrical safety is not guaranteed when applied on the human body. Therefore, in this study, we did research on the corrosiveness of electroacupuncture when applied on the body fluid. Methods : We did research using acupuncture needles which were made of STS304 or STS316 and which were coated or not coated in silicone. They were 0.25 mm in diameter and 40 mm in length. We immersed them to the depth of about 1cm in Hank's Solution and gave a stimulus in 120 Hz for 60 minutes. Then, we measured the pH of Hank's solution and mass of needles and observed their shape. Results : Acupuncture needles which were made of STS304 corroded more easily than those which were made of STS316 when they were applied on the human body. Acupuncture needles which were coated in silicone corroded much more easily than those which were not coated in silicone when they were applied on the body fluid. Conclusions : In this study, we did research on the corrosiveness of electroacupuncture when it is applied on the body fluid using several acupuncture needles. We made a conclusion that when acupuncture needles were applied on the body fluid, the coated one made of STS304 corrodes more easily than the uncoated one made of STS316. We hope that additional further researches on the effect of the corrosiveness of an acupuncture needle will be carried out.

STS 304의 선삭에서 공구수명 향상을 위한 공구형상 (Tool Geometry for Improving Tool-Life in Turning of STS 304)

  • 이재우
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.581-584
    • /
    • 2003
  • The austenitic STS 304 stainless steel was turned to clarify the effects of tool geometry on the tool wear. The wear of TiN-TiCN-TiC-TiAlN coated tungsten carbide tool was the smallest, exhibiting larger wear in the order of Si-Al-O-N ceramic, TiN coated tungsten carbide, TiN-TiCN-TiN coated tungsten carbide, TiC-TiN cermet and M20 tungsten carbide tools at the same cutting conditions. The S-type tool of M20 with large approach angle showed the longest tool life of all tools used in this tests due to preventing the groove wear of the side cutting edge. The wear of the S-type tool with the rake angle of 15$^{\circ}$became smaller than with that of -5$^{\circ}$, but the tool with the nose radius of 0.8mm did not perform much better with increasing the rake angle.

  • PDF

STS 304 선삭시의 공구마멸 특성 (Tool-Wear Characteristics in Turning of STS 304)

  • 이재우
    • 한국정밀공학회지
    • /
    • 제20권10호
    • /
    • pp.56-64
    • /
    • 2003
  • The effect of tool geometry on the tool wear in turning the austenitic stainless steel, STS 304 was investigated. The wear of TiN-TiCN-TiC-TiAlN coated tungsten carbide tool was the smallest, showing larger wear in the order of Si-Al-O-N ceramic, TiN coated tungsten carbide, TiN- TiCN- TiN coated tungsten carbide, TiC-TiN cermet and M20 tungsten carbide tools at the same cutting conditions. The S-type tool of M20 with the larger side cutting edge angle showed the smallest tool wear in all tests due to preventing the groove wear of the side cutting edge. The wear of the S-type tool with the rake angle of $15^{\circ}$ became smaller than with that of $-5^{\circ}$, but the tool with the nose radius of 0.8mm did not perform much better with increasing the rake angle.

소성가공에 따른 STS 304L 재료의 기계적 특성 및 피로평가 (Evaluation of Mechanical Properties and Fatigue Behavior of STS 304L due to Plastic Working)

  • 심현보;김영균;서창민
    • 대한기계학회논문집A
    • /
    • 제41권7호
    • /
    • pp.635-643
    • /
    • 2017
  • STS 304L 강재의 냉간압연율의 증가에 따라 t가 1.5 mm에서 1.1 mm까지 감소하면 인장강도, 항복강도, 경도치 및 UFT피로시험의 피로한도는 선형적으로 증가하였다. t=1.5 mm, t=1.4 mm, t=1.3 mm 및 t=1.1 mm인 4가지 시험편의 UFT피로시험(R= -1)결과, 회전굽힘피로시험(R= -1)의 결과처럼 $10^6$ 영역에서 S-N곡선의 피로한도가 절점(knee point)을 형성하였고, 기가사이클 피로에서 생기는 현상인 피로한도가 추가로 감소하지않았다. 또 t=1.1 mm인 경우 가장 높은 피로한도 345 MPa로 되었고, 원소재(t=1.5 mm)에 대하여 64.3 % 증가하였다. 냉간압연율에 따른 UFT피로시험결과 많은 작은 표면균열이 티어링(tearing)하면서 발생, 성장, 서로 합체하였다.

무윤활 수직-수평 복합하중 조건에서 재료조합에 따른 마모특성 변화에 관한 실험적 연구 (Experimental Study on Wear Behavior of Material Pairs under Normal and Sliding Mixed Loading Conditions)

  • 최성우;민준기;정일욱;박상후
    • 한국정밀공학회지
    • /
    • 제26권11호
    • /
    • pp.131-137
    • /
    • 2009
  • A pair of connectors for transferring torque is widely used in various types of a mechanical system. By the repetition of mechanical contact between a pair of connector, wear occurs easily. This kind of defect sometimes can cause a serious problem of health in case of the connector is used in a refrigerator. In this work, the material combination of connectors was experimentally studied to reduce the amount of wear; for the combination of connectors, various types of engineering materials including polyacetal, polycabonate, stainless steel (STS-304), NiP coated STS-304, and STS-310 were evaluated to check each wear behavior. Also an effective method of wear test was suggested for precise controlling of wear conditions such as contact area, contact force, and relative motion speed. From the test results, it was found out that a pair of polyacetal to STS-304 and STS-310 showed the lowest specific wear rates among other pairs.