• Title/Summary/Keyword: STEP-LENGTH

Search Result 1,046, Processing Time 0.026 seconds

Chronological Study on the Deposits by Indicators of Woody Plants (수목지표(樹木指標)에 의한 하상퇴적지(河床堆積地)의 연대학적(年代學的) 연구(硏究))

  • Chun, Kun Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.81 no.3
    • /
    • pp.263-272
    • /
    • 1992
  • In a torrential river, the flow of debris forms deposits in the river bed, which show the characteristics of the channel bed movement in the watershed. The annual rings of the trees, in the natural evenaged forests on the deposits, indicate when each deposit occurred. Based on the topographical and vegetational indicators on the sediment of Yongcheon and Yeounae rivers, the movement occurrence years were estimated. 1. The cross sectional shapes of deposits in torrential river are in tiers and even-aged forests tend to establish on each tier. 2. Generally the older the forest age is, the higher the height of step from the lowest base tend to become, which indicates discrete movement in magnitude and frequency. 3. The ages of trees indicate the year when deposition occurred, and so may be useful as plant indicator to get spatial-temporal information of deposits. 4. The deposits volumes(F. V.) were dependent on the age distribution of deposits in length, average width and average height. And the average width and the average height of deposits were increasing with the age.

  • PDF

Evaluation of Thermal Movements of a Cable-Stayed Bridge Using Temperatures and Displacements Data (온도와 변위 데이터를 이용한 사장교의 온도신축거동 평가)

  • Park, Jong Chil
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.4
    • /
    • pp.779-789
    • /
    • 2015
  • Because cable-supported bridges have long spans and large members, their movements and geometrical changes by temperatures tend to be bigger than those of small or medium-sized bridges. Therefore, it is important for maintenance engineers to monitor and assess the effect of temperature on the cable-supported bridges. To evaluate how much the superstructure expands or contracts when subjected to changes in temperature is the first step for the maintenance. Thermal movements of a cable-stayed bridge in service are evaluated by using long-term temperatures and displacements data. Displacements data are obtained from extensometers and newly installed GNSS (Global Navigation Satellite System) receivers on the bridge. Based on the statistical data such as air temperatures, each sensor's temperatures, average temperatures and effective temperatures, correlation analysis between temperatures and displacements has been performed. Average temperatures or effective temperatures are most suitable for the evaluation of thermal movements. From linear regression analysis between effective temperatures and displacements, the variation rate's of displacement to temperature have been calculated. From additional regression analysis between expansion length's and variation rate's of displacement to temperature, the thermal expansion coefficient and neutral point have been estimated. Comparing these parameters with theoretical and analytical results, a practical procedure for evaluating the real thermal behaviors of the cable-supported bridges is proposed.

Development of Portable-Type Electrode for the Determination of Highly Concentrated Hydrogen Peroxide (휴대용 고농도 과산화수소 측정 전극의 개발)

  • Lee, Jin Seo;Cui, Gang;Kim, Sang Jin;Cha, Geun Sig;Nam, Hakhyun;Rho, Kyung Lae;Kim, Jin Doo
    • Analytical Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.125-129
    • /
    • 1999
  • Portable-type two electrode system for the determination of highly concentrated hydrogen peroxide (10-75%) has been studied. The electrode body was made with teflon rod (length=10 cm, diameter=1.5 cm) to withstand the highly corrosive power of hydrogen peroxide. Glass carbon rod (diameter=3 mm) was used as the working electrode and a carbon cylinder (i.d.=5 mm; o.d.=9 mm) was used as counter electrode. The applied voltage for the determination of $H_2O_2$ was 0.8 V. Diluting the highly concentrated samples taken from the industrial batch to 10% or less, it was possible to make quantitative determinations, while eliminating the interference from the stabilizer contained in the sample and preventing the surface of the electrode from oxidative corrosion. Employing hydrogen peroxide permeable membrane (teflon membrane${\leq}100{\mu}m$) for the electrode system, it was possible to measure the content of $H_2O_2$ in highly concentrated samples directly, quantitatively and reproducibly with no extra dilution step. However, it was necessary to change the internal electrolyte frequently to maintain the analytical performance of the electrode.

  • PDF

Characterization of Transgenic Lettuce (Lactuca sativa L.) Using a BL1 Gene Encoding Bromelain Isolated from Pneapple (제주산 파인애플 유래 Bromelain관련 유전자 (BL1)를 이용반 형질전환 상추의 특성)

  • Jung, Yu-Jin;Kim, Gi-Hyun;Choi, Jang-Sun;Lee, Soon-Youl;Nou, Il-Sup;Park, Jin-Heui;Kang, Kwon-Kyoo
    • Journal of Plant Biotechnology
    • /
    • v.33 no.1
    • /
    • pp.27-32
    • /
    • 2006
  • To clarify the roles of bromelain in plants, we isolated BL1 gene encoding bromelain from pineapple stem tissues and sequenced. The full length cDNA is 933 bp and encodes a polypeptide of 311 amino acid residues. The cDNA is most similar 94% at the amino acid level to bromelain previously isolated from pineapple (BAA21929). Explants of Lactuca sativa were co-cultivated with Agrobacterium tume-faciences LBA 4404 strains containing nptII and BL1 gene for transformation. Through initial selection of regenerated explants by culturing on a kanamycin and carbenicillin containing MS medium, multiple shoots were obtained after 2 months of culture. For a complementary step of selection, putative transgenic shoots were transferred to 1/2 Ms basal medium supplemented with 100 mg/L kanamycin and 500 mg/L carbenicillin. The selected shoots were obtained T1 generation seeds with emasculation, and tested with PCR analysis using 35S promoter and BL1 specific primers whether BL1 gene was introduced to genome of the plants. These results confirmed that produced the specific PCR bands in the putative transgenic lines. Additionally the Northern blot and endo protease activity showed that transcripts of BL1 gene were detected in transgenic lines. Theses results suggest that BL1 gene be successfully integrated and transcripted in the transgenic lettuce plants.

The Effects of Health Exercise Program on Walking ability, Depression and WHOQOL-BREF in the Fall experienced Women Elderly (건강체조 프로그램이 낙상경험 여성노인의 보행능력, 우울 및 삶의 질에 미치는 효과)

  • Kim, Young-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.10
    • /
    • pp.3726-3732
    • /
    • 2010
  • The purpose of this study was to investigate the effects of health exercise program to old Women's walking ability, depression and WHOQOL-BREF. Data were collected from April to June, 2007 from the falls experienced 70 women elderly. All subjects participated in 12 week health exercise program which was designed in order to develop walking ability. The data were analyzed using frequency, %, paired t-test. The results of this study were as followings; First, there was significant differences in the average time of chair stand (t=2.291, p=.025), one leg standing(Rt. leg)(t=2.236, p=.029), step length between before and after(t=4.015, p=.000) training of 12 week health exercise program. Second, there was non significant differences in depression(t=1.044, p=.300) but, significant differences in WHOQOL-BREF(t=3.528, p=.001). The WHOQOL-BREF in general quality of life(t=2.923, p=.005), physical(t=3.039, p=.003), psychological(t=2.481, p=.016), social(t=2.531, p=.014) and environment domain(t=4.259, p=.000) were significant differences. The results suggest that the 12 week health exercise program can improve the muscle endurance and balance, QOL.

Flexural Behavior of Segmental U-Girder and Composite U-Girder Using Ultra High Performance Concrete (초고강도 섬유보강 콘크리트를 사용한 분절형 U거더 및 합성 U거더의 휨거동)

  • Lee, Seung-Jae;Makhbal, Tsas-Orgilmaa;Kim, Sung-Tae;Han, Sang-Mook
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.3
    • /
    • pp.290-297
    • /
    • 2017
  • The flexural behavior tests of UHPC segmental U-girder and composite U-girder which has 160MPa compressive strength and 15.4m length were carried out. The test variables are volume fraction of steel fibers and slab over the U-girder. Each U-girder has longitudinal re-bars in web and lower flange. PS tendons which has 2 of 15.2mm diameter in upper flange and PS tendons which has 7 of 15.2mm diameter in lower flange were arranged and prestressed at onetime in U-girder connection stage. Enough strong prestressing force which applied to U-girder due to ultra high performance concrete strength can withstand the self weight and dead load in U-girder stage. By comparison with the brittle behavior of U-girder, composite U-girder showed the stable and ductile behavior. After the construction of slab over U-girder, flexural load capacity of composite U-girder can bear the design load in final construction stage with only one time prestressing operation which already carried out in U-girder stage. This simple prestressing method due to the ultra high strength concrete have the advantage in construction step and cost. The shear key which has narrow space has the strong composite connection between ultra high strength concrete U-girder and high strength concrete slab didn't show any slip and opening right before failure load.

High-$T_c$ 2nd-order SQUID Gradiometer for Use in Unshielded Environments (비차폐 환경에서의 고온초전도 SQUID 2차 미분기의 특성연구)

  • 박승문;강찬석;이순걸;유권규;김인선;박용기
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.50-54
    • /
    • 2003
  • We have fabricated $∂^2$$B_{z}$ /$∂x^2$ type planar gradiometers and studied their properties in operation under various field conditions. $YBa_2$$Cu_3$$O_{7}$ film was deposited on $SrTiO_3$ (100) substrate by a pulsed laser deposition (PLD) system and patterned into a device by the photolithography with ion milling technique. The device consists of 3 pickup loops designed symmetrically Inner dimension and the width of the square side loops are 3.6 mm and 1.2 mm, respectively, and the corresponding dimensions of the center loop are 2.0 mm and 1.13 mm. The length of baseline gradiometer is 5.8 mm. Step-edge junction width is 3.0 $\mu\textrm{m}$ and the hole size of the SQUID loop is 3 $\mu\textrm{m}$ ${\times}$ 52 $\mu\textrm{m}$. The SQUID inductance is estimated to be 35 pH. The device was formed on a 20 mm ${\times}$ 10 mm substrate. We have tested the behavior of the device in various field conditions. The unshielded gradiometer was stable under extremely hostile conditions on a laboratory bench. Noise level 0.45 pT/$\textrm{cm}^2$/(equation omitted)Hz and 0.84 pT/$\textrm{cm}^2$/(equation omitted)Hz at 1 Hz for the shielded and the unshielded cases, which correspond to equivalent field noises of 150 fT/(equation omitted)Hz and 280 fT/(equation omitted)Hz, respectively. In spite of the short baseline of 5.8 mm, the high common-mode-rejection-ratio of the gradiometer, $10^3$, allowed us to successfully record magnetocardiogram of a human subject, which demonstrates the feasibility of the design in biomagnetic studies.

  • PDF

Association between muscular strengths and gait characteristics of elderly people aged 65 to 74 and 75 and above (전·후기 노인의 근력과 보행 특성의 관계)

  • Back, Chang-Yei;Joo, Ji-Yong;Kim, Young-Kwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.2
    • /
    • pp.415-422
    • /
    • 2020
  • This study investigates the relationship between muscular strengths and gait characteristics of the elderly. Totally, 107 subjects, aged 65 to 85 years, participated in this study. Researchers measured muscle strengths (grip force, toe grip force, gluteus medius, and gluteus maximus forces) and walking characteristics (walking speed, cadence, step length, single leg support, and double legs support). Dynamometers and inertial measurement unit-based shoe systems were used for measuring muscular strength and gait characteristics, respectively. No significant difference was observed in strengths and walking characteristics between the young elders (YE, 65-74 years) and the old elders (OE, 75-85 years). For each age, muscular strength significantly correlated with some gait parameters. Forces of gluteus medius and gluteus maximus muscles showed better significant correlations between some gait parameters for all age groups, as compared to grip force and toe grip force. Regression coefficients between walking speed and grip force did not vary with age. We conclude that muscular strengths in OE better explained the gait characteristics than in YE subjects. Even though grip strength is an easily measured variable for senior fitness test, forces of gluteus medius and gluteus maximus muscles are more meaningful for understanding the walking characteristics of elderly people.

Characterization of TRAF4 mRNA and Functions related to tight junction in pig (돼지에서 TRAF4 유전자 특성 및 Tight junction 관련 기능 분석)

  • Yun, Jeong-hee;Hwang, In-Sul;Hwang, Seongsoo;Park, Mi-Ryung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.216-222
    • /
    • 2020
  • Tumor necrosis factor receptor associated factor 4 (TRAF4) is found to be overexpressed in human breast cancer. It plays a role in cancer metastasis, production of reactive oxygen species, and cell polarity at membranes. The characteristics and functions of TRAF4 in pigs have not yet been identified. As the first step of research, the mRNA sequence of TRAF4 in porcine cells has been determined. To obtain the full-length sequence, rapid amplification of cDNA ends (RACE) has been carried out. Upon cloning, 2,030 bp of nucleotides were found to encode 470 amino acids, and 8 and 12 amino acids were different from those of the human and mouse TRAF4, respectively. The coding region of porcine TRAF4 was shown to be 93% and 90% homologous to human and mouse TRAF4, respectively. qPCR was conducted to determine the relative expression level of TRAF4. TRAF4 expression in pK15 was enhanced by cell-cell contacts. The mRNA levels of CLDN4, OCLN, and TJP1 at 60% and 80% confluency were significantly higher than at 40% confluency. Further, TRAF4 and tight junction-related genes were down-regulated upon treatment with TRAF4 siRNA. Thus, TRAF4 may affect the function of tight junctions in pig.

A Study on the Nursing Needs and Service Satisfactory of Users in the Post-Partum Care Center (산후조리원을 이용한 산모의 간호요구 및 만족도)

  • Jung, Hyun
    • Women's Health Nursing
    • /
    • v.5 no.2
    • /
    • pp.222-229
    • /
    • 1999
  • These days, as the society has been in the trends of highly industrialized and the family has been downsized, there is remarkably increasing number of women who follow occupation. These changes have made it more difficult for the family to help post-partum mother, which had been performed in side of house. By the help of social believe that during at least 1 month after childbirth professional nursing program is indispensable for both maternity protection and physical-mental recuperation, now many post-partum care centers for post-partum mother have been in operation. Although these post-partum care center have in use for a long time, no study was performed before this study on the same subject. Data were analyzed using by SAS. The results of study are as follow : 1. The general features of the user of the post-partum care center. The predominant band of user's age is extended from 26 to 30. The users are mainly housewives and they are in higher level of incomes and educations. As for the feature of delivery methods, they performed the normal spontaneous vaginal delivery method by 58.0% and the Caesarean operation method by 42.0%. As for the sexuality for babies, 59.3% of infants are male, and 40.7% are female. The highest delivery order of users is first and admission after 1-3days delivery is highest. 2. The results for the investigation into the actual condition of the post-partum care center are as follow : About the main reason for entrance of the post-partum care center was found to be the needs for the better nursing programs for recuperation after childbirth. This demands are also supported by their husbands. The average length of stay in the post-partum care center is 17.6 days and the besides promised expense ; powdered milk, milk-suckers, disposable dippers, skin cares, body shape cares, entrophics, injections. The post-partum have private rooms for mother and infants. Over the half of average expense is 229 million won. They are paying accessory fees the post-partum care center have similar step organization : the nurses, the skin carers, the cleaners. Mostly both ways of feeding powdered milk and breast feeding are in use, and mother's milk is preserved in the night time to be given to infant by nurse in charge. 3. The results of the investigation on users' nursing demand to the post-partum care center and satisfaction are as follow : The ranking order of nursing demand of mothers who used the is that ; infant care demands, environmental demands, emotional and mental care demands, education and training demands. As much as 70% of the respondents have dissatisfaction in nursing program, The ranking order of service satisfaction of mothers who used appears to be higher following order ; satisfaction in infant care demand, satisfaction in physical nursing demand, satisfaction in emotional and mental nursing demand, satisfaction in education and training demand, satisfaction in environment nursing demand. The results of pearson correlation. between nursing demand and service satisfaction of mothers who used are found to be relative noticeable in the level of 0.05. only infant care. The 61.7% of the women who used the post-partum care center. are responding that they will reuse the same post-partum care center again.

  • PDF