• Title/Summary/Keyword: STEP-LENGTH

Search Result 1,050, Processing Time 0.033 seconds

Manufacture of Printing and Writing Papers from Old Corrugated Containers (OCC) (Old Corrugated Containers (OCC)로부터 인쇄·필기용지 제조)

  • Lee, Goo;Ahn, Byoung-Jun;Paik, Ki-Hyon
    • Applied Chemistry for Engineering
    • /
    • v.10 no.3
    • /
    • pp.367-373
    • /
    • 1999
  • Increasing consumer demand for recycle of most paper products is challenging manufacturers to use lower value raw materials while maintaining high quality. This study was carried out to investigate the composition of old corrugated containers (OCC) and to manufacture printing and writing papers of over 85% (ISO) brightness by ECF and TCF bleaching from OCC. Fiber length of American old corrugated container (AOCC) was longer than that of Korean old corrugated container (KOCC) in fiber length. The former was composed of unbleached kraft pulp (UKP) of about 80 percentage, the latter about 20 percentage. OCC is feasible for manufacturing of pulps i.e., AOCC is for printing and writing papers and KOCC is for whiteboards, in the aspects of brightness and mechanical properties on the other hand, the cost of manufacturing upgraded papers by OCC is high because of bleaching chemicals. Neverthless, considering various aspects, especially environment, there are many advantages in recycling. In case of the treated AOCC pulp, over 85% (ISO) brightness can be achieved through TCF or ECF bleaching step, while the treated KOCC pulp did not allow high brightness through TCF bleaching. The tensile index of the bleached KOCC pulp was lower than that of the bleached AOCC pulp, but the burst and tear index of KOCC was higher than that of AOCC.

  • PDF

Unsteady 2-D flow field characteristics for perforated plates with a splitter

  • Yaragal, Subhash C.
    • Wind and Structures
    • /
    • v.7 no.5
    • /
    • pp.317-332
    • /
    • 2004
  • Wind tunnel experiments were conducted under highly turbulent and disturbed flow conditions over a solid/perforated plate with a long splitter plate in its plane of symmetry. The effect of varied level of perforation of the normal plate on fluctuating velocities and fluctuating pressures measured across and along the separation bubble was studied. The different perforation levels of the normal plate; that is 0%, 10%, 20%, 30%, 40% and 50% are studied. The Reynolds number based on step height was varied from $4{\times}10^3$ to $1.2{\times}10^4$. The shape and size of the bubble vary with different perforation level of the normal plate that is to say the bubble is reduced both in height and length up to 30% perforation level. For higher perforation of the normal plate, bubble is completely swept out. The peak turbulence value occurs around 0.7 to 0.8 times the reattachment length. The turbulence intensity values are highest for the case of solid normal plate (bleed air is absent) and are lowest for the case of 50% perforation of the normal plate (bleed air is maximum in the present study). From the analysis of data it is observed that $\sqrt{\overline{u^{{\prime}2}}}/(\sqrt{\overline{u^{{\prime}2}}})_{max}$, (the ratio of RMS velocity fluctuation to maximum RMS velocity fluctuation), is uniquely related with dimensionless distance y/Y', (the ratio of distance normal to splitter plate to the distance where RMS velocity fluctuation is half its maximum value) for all the perforated normal plates. It is interesting to note that for 50% perforation of the normal plate, the RMS pressure fluctuation in the flow field gets reduced to around 60% as compared to that for solid normal plate. Analysis of the results show that the ratio [$C^{\prime}_p$ max/$-C_{pb}(1-{\eta})$], where $C^{\prime}_p$ max is the maximum coefficient of fluctuating pressure, $C_{pb}$ is the coefficient of base pressure and ${\eta}$ is the perforation level (ratio of open to total area), for surface RMS pressure fluctuation levels seems to be constant and has value of about 0.22. Similar analysis show that the ratio $[C^{\prime}_p$ max/$-C_{pb}(1-{\eta})]$ for flow field RMS pressure fluctuation levels seems to be constant and has a value of about 0.32.

Chip-level NFP Calibration and Verification Using Improved Probe for NFS Standardization (NFS 표준을 위한 개선된 프로브를 이용한 칩 수준 NFP 측정값 교정 및 검증)

  • Lee, Pil-Soo;Wee, Jae-Kyung;Kim, Boo-Gyoun;Choi, Jai-Hoon;Yeo, Soon-Il
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.49 no.6
    • /
    • pp.25-34
    • /
    • 2012
  • New calibration method for the near-field scanning (NFS) system is presented. The proposed calibration method consisted of a new near-field antenna (NFP) and newly devised patterns as circular patch patterns (CPPs) and meander patterns (MPs). The proposed patterns were used for improving spatial resolutions and simplifying a calibration procedure of the NFP compared to the conventional method defined in the IEC61967-3 and 6. Also, the effect of the length of NFPs on attenuation characteristics was investigated with length of 8mm and 30mm. For them, we designed and fabricated CPPs of diameter (D) = 20, 40, 60, and 100mm and MPs of various widths and spaces. We found the reverse relations between spatial resolutions and heights of measuring points by using simplified calibration procedure. The testing result shows that the spatial resolution of $120{\mu}m$ at height of $200{\mu}m$ was verified without complex correlation algorithms under 8GHz. For manufacturing cost all patterns and the NFP were realized with low-cost fabrication using PCB (FR-4) not by a conventional LTCC process. For verification of chip-level EMC from the results, near-field scanning system (NFSS) having step resolution of Sub-micron scale was produced and by using the proposed NFSS and proposed NFP measurement of chip shows accurately the shape of the resolution of $200{\mu}m$ patterns for securing a high level of chip-level EMC verification.

EFFECT OF CALCIUM HYDROXIDE REMNANT AS AN INTRACANAL DRESSING ON THE APICAL LEAKAGE (근관내 잔존 Calcium Hydroxide제재가 치근단 미세누출에 미치는 영향)

  • 신수일;조용범
    • Restorative Dentistry and Endodontics
    • /
    • v.26 no.1
    • /
    • pp.77-85
    • /
    • 2001
  • The purpose of this in vitro study was to compare the apical leakage in extracted teeth filled with gutta-percha subsequent to dressing with one of three different calcium hydroxide preparations. Thirty six extracted teeth with single canal were used in this study. After working length determination, canals were prepared with K flexo files to a #40 at the working length. Step-back flaring was produced by using #45, #50 K flexo files and #2, #3, #4 Gates Glidden burs. The teeth were randomly divided into 3 groups of 10 each : the remaining six teeth were used for negative and positive leakage control: Group 1, dressed with pure calcium hydroxide powder (Sigma, USA) mixed with distilled water; Group 2, dressed with Metapaste (Metadent, Korea) ; Group 3, dressed with Vitapex (Neo Dental, Japan). Teeth were sealed with Caviton (GC, Japan) and incubated in 100% humidity, at 37$^{\circ}C$ for 1 wk. All kinds of calcium hydroxide were removed from the canal with a MAF and 5% NaOCl. The canals were filled with AH-26$^{\circledR}$ sealer and gutta-percha using lateral condensation technique, incubated in 100% humidity, at 37$^{\circ}C$ for 2 days for the sealer to be set. The teeth were coated twice with nail varnish except for an area of approximately 2mm surrounding the apical foramen. All specimens were placed in 2% methylene blue solution for 2 days. The root were sectioned longitudinally, the amount of apical leakage was measured to the most coronal part of the root canal to which the dye had penetrated. The independent measurements were made for each root using a stereomicroscope ($\times$40 magnification) and the average was recorded for statistical analysis. The results were as follows ; 1. The mean of apical leakage in group of pure calcium hydroxide ranged 0.102$\pm$0.156mm, in Metapaste$^{\circledR}$ ranged 0.062$\pm$0.069mm, and in Vitapex$^{\circledR}$ ranged 0.067$\pm$0.072mm. 2. Group of pure calcium hydroxide exhibited more leakage than those of 2 manufactured calcium hydroxide preparations, but it was not statistically significant. 3. Group of water-based Metapaste$^{\circledR}$ showed lesser leakage than that of oil-based Vitapex$^{\circledR}$, but it was not statistically significant.

  • PDF

Comparative Analysis of Korean and American Body Sizes & Shapes using 3D Scanned Anthropometric Data (한국과 미국 성인의 3차원 인체 치수 비교)

  • Yi, Kyong-Hwa;Istook, Cynthia;Kang, Yeo-Sun;Choi, Hei-Sun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.31 no.6 s.165
    • /
    • pp.892-901
    • /
    • 2007
  • This research is the initial step for establishing a convertible body sizing table applicable to the Korean and American female apparel industry. All 3D female measurement data of the two countries were obtained from Size Korea Project and SizeUSA Project. The sample subjects used in this study were 1,988 Korean and 6,306 American females. Thirty-four(34) variables were chosen as the principal measurements in making garments. The conclusion of this research was as follow: First, it was determined that American women were larger and longer than Korean women in all measurement except shoulder slope measurement. Second, according to the differences analysis of the each age group in Korean Females, all measurements except hip girth had significant differences among the age groups. In case of American females, all measurements except arm length(shoulder to wrist) had significant differences among the age groups. Third, in the comparison of differences between the age groups of the two countries' women, some dimensions varied significantly with age, while others did not show any statistical significance among the age groups. Fourth, according to the t-tests of same age groups between Korean & American female measurements, American female measurements were larger and longer than Korean in all measurements except crotch length total, shoulder slope, hip girth-bust girth and hip girth-waist girth.

n-Gram/2L: A Space and Time Efficient Two-Level n-Gram Inverted Index Structure (n-gram/2L: 공간 및 시간 효율적인 2단계 n-gram 역색인 구조)

  • Kim Min-Soo;Whang Kyu-Young;Lee Jae-Gil;Lee Min-Jae
    • Journal of KIISE:Databases
    • /
    • v.33 no.1
    • /
    • pp.12-31
    • /
    • 2006
  • The n-gram inverted index has two major advantages: language-neutral and error-tolerant. Due to these advantages, it has been widely used in information retrieval or in similar sequence matching for DNA and Protein databases. Nevertheless, the n-gram inverted index also has drawbacks: the size tends to be very large, and the performance of queries tends to be bad. In this paper, we propose the two-level n-gram inverted index (simply, the n-gram/2L index) that significantly reduces the size and improves the query performance while preserving the advantages of the n-gram inverted index. The proposed index eliminates the redundancy of the position information that exists in the n-gram inverted index. The proposed index is constructed in two steps: 1) extracting subsequences of length m from documents and 2) extracting n-grams from those subsequences. We formally prove that this two-step construction is identical to the relational normalization process that removes the redundancy caused by a non-trivial multivalued dependency. The n-gram/2L index has excellent properties: 1) it significantly reduces the size and improves the Performance compared with the n-gram inverted index with these improvements becoming more marked as the database size gets larger; 2) the query processing time increases only very slightly as the query length gets longer. Experimental results using databases of 1 GBytes show that the size of the n-gram/2L index is reduced by up to 1.9${\~}$2.7 times and, at the same time, the query performance is improved by up to 13.1 times compared with those of the n-gram inverted index.

SEM EVALUATION OF THE PREPARED ROOT CANALS BY HAND AND Ni-Ti ROTARY ROOT CANAL INSTRUMENTS (Hand & rotary root canal instrument의 근관내 삭제 형태에 관한 전자현미경적 비교)

  • Oh, Tae-Seok;Park, Jeong-Won
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.477-486
    • /
    • 1998
  • Recently the development of rotary instrument makes it possible that in root canal treatment operator saves much more time, maintans original curved canal shape and easily prepares continuous tapered root canal. The purpose of this experiment was to examine the smoothness of the internal surface of prepared root canal and the effectiveness of debridement in prepared root canal by SEM for the comparison of hand and Ni-Ti rotary instrument. 25 extracted human teeth were access opened and # 10 K-type file was introduced into canal until it was appeared at the apical foramen. The working length was established by subtracting 0.5mm from this measurement. Group 1. The root canal preparation was done to # 30 with working length and then step-back until # 45 with K-Flexofile (Maillefer, Swiss). Group 2. Root canal preparation was done by Naviflex Ni-Ti file (Brasseler, USA) as the same technique with group 1. Group 3. Canal was prepared by Profile .04 (Maillefer, Swiss) taper until #30. Group 4. With use of Quantec (Tycom, USA) root canal was prepared from file number 1 to 8. In group 1 and 2, the root canal irrigant was NaOCl and the other groups, NaOCl and RC-prep (Premine Dental Products, USA) was used. The prepared teeth were notched with high-speed bur as bucco-lingual direction and fractured with chisel and mallet, then examined with SEM. Group 1 showed smooth internal surface. There were scratches mainly to the axial direction. Group 2 showed similar characteristics to those in group 1. Group 3 showed more smoother and linear cutting surface with bised scratches. Group 4 has the almost same characteristics group 3 and there was no difference in the file design. Ni-Ti rotary root canal instrument prepare the dentinal wall more smoother than hand instrument. The effectiveness of debridement was not fully affected by file design. The isthmus area and accessory canals of the root canal system were not prepared in any group. According to the result, hand and rotary type instrumentation techniques were effective in removal of major amount of tissue from root canal but it was not complete. In the direction of cutting movement there was difference between them.

  • PDF

Simulation Study of a Large Area CMOS Image Sensor for X-ray DR Detector with Separate ROICs (센서-회로 분리형 엑스선 DR 검출기를 위한 대면적 CMOS 영상센서 모사 연구)

  • Kim, Myung Soo;Kim, Hyoungtak;Kang, Dong-uk;Yoo, Hyun Jun;Cho, Minsik;Lee, Dae Hee;Bae, Jun Hyung;Kim, Jongyul;Kim, Hyunduk;Cho, Gyuseong
    • Journal of Radiation Industry
    • /
    • v.6 no.1
    • /
    • pp.31-40
    • /
    • 2012
  • There are two methods to fabricate the readout electronic to a large-area CMOS image sensor (LACIS). One is to design and manufacture the sensor part and signal processing electronics in a single chip and the other is to integrate both parts with bump bonding or wire bonding after manufacturing both parts separately. The latter method has an advantage of the high yield because the optimized and specialized fabrication process can be chosen in designing and manufacturing each part. In this paper, LACIS chip, that is optimized design for the latter method of fabrication, is presented. The LACIS chip consists of a 3-TR pixel photodiode array, row driver (or called as a gate driver) circuit, and bonding pads to the external readout ICs. Among 4 types of the photodiode structure available in a standard CMOS process, $N_{photo}/P_{epi}$ type photodiode showed the highest quantum efficiency in the simulation study, though it requires one additional mask to control the doping concentration of $N_{photo}$ layer. The optimized channel widths and lengths of 3 pixel transistors are also determined by simulation. The select transistor is not significantly affected by channel length and width. But source follower transistor is strongly influenced by length and width. In row driver, to reduce signal time delay by high capacitance at output node, three stage inverter drivers are used. And channel width of the inverter driver increases gradually in each step. The sensor has very long metal wire that is about 170 mm. The repeater consisted of inverters is applied proper amount of pixel rows. It can help to reduce the long metal-line delay.

Comparison of gait ability according to types of assistive device for ankle joint of chronic hemiplegic stroke survivors (발목관절 보조 도구에 따른 만성 뇌졸중 편마비 장애인의 보행 비교)

  • Park, Dong-Chun;Jung, Jung-Hee;Kim, Won-Deuk;Son, Il-Hyun;Lee, Yang-Jin;Lee, GyuChang
    • Journal of Korean Physical Therapy Science
    • /
    • v.28 no.2
    • /
    • pp.30-39
    • /
    • 2021
  • Background: The purpose of this study was to compare the differences in gait and mobility according to the types of assistive device for ankle joint including ankle foot orthosis (AFO), non-elastic tape, elastic tape, and high ankle shoes in chronic hemiplegic stroke survivors. Design: A cross-over design. Methods: Twelve hemiplegic stroke survivors participated in this study, and they walked under 5 different conditions including bare feet, wearing a AFO, wearing a non-elastic tape, wearing a elastic tape, and wearing a high ankle shoes. During the participants walked, the spatio-temporal gait analysis and mobility examinations were performed. For the spatio-temporal gait analysis (gait velocity and cadence, step length, stride length, and single and double leg support time) and mobility examinations, the gait mat, TUG and TUDS were used. Results: As s results, on the AFO, non-elastic tape, elastic tape, and high ankle shoes, there were significantly differences in the all spatio-temporal gait parameters, TUG, and TUDS compared to barefoot (p<0.05). In particular, all spatio-temporal gait parameters, TUG, TUDS were significantly improved with AFO compared to barefoot. TUG was significantly improved with AFO compared to non-elastic tape, TUG and TUDS were significantly improved with AFO compared to elastic tape, gait velocity was significantly improved with non-elastic tape compared to high ankle shoes, gait velocity and TUG were significantly improved with elastic tape compared to high ankle shoes, and TUDS was significantly improved with non-elastic tape compared to elastic tape. Conclusion: The AFO, non-elastic tape, elastic tape, and high ankle shoes showed a positive effect on gait and mobility compared to barefoot, and among them, wearing AFO was most effective for improving gait and mobility of chronic hemiplegic stroke survivors.

Study on Adsorption Characteristics of Perfluorinated Compounds(PFCs) with Structural Properties (과불화화합물 구조적 속성에 따른 흡착 특성 연구)

  • Choi, HyoJung;Kim, Deok Hyun;Yoon, JongHyun;Kwon, JongBeom;Kim, Moonsu;Kim, Hyun-Koo;Shin, Sun-Kyoung;Park, Sunhwa
    • Journal of Soil and Groundwater Environment
    • /
    • v.26 no.5
    • /
    • pp.20-28
    • /
    • 2021
  • Perfluorinated compounds(PFCs), an emerging environmental pollutant, are environmentally persistent and bioaccumulative organic compounds that possess a toxic impact on human health and ecosystems. PFCs are distributed widely in environment media including groundwater, surface water, soil and sediment. PFCs in contaminated solid can potentially leach into groundwater. Therefore, understanding PFCs partitioning between the aqueous phase and solid phase is important for the determination of their fate and transport in the environment. In this study, the sorption equilibrium batch and kinetic experiment of PFCs were carried out to estimated the sorption coefficient(Kd) and the fraction between aqueous-solid phase partition, respectively. Sorption branches of the PFDA(Perfluoro-n-decanoic acid), PFNA(Perfluoro-n-nonanoic acid), PFOA(Perfluoro-n-octanoic acid), PFOS(Perfluoro-1-octane sulfonic acid) and PFHxS(Perfluoro-1-hexane sulfonic acid) isotherms were nearly linear, and the estimated Kd was as follow: PFDA(1.50) > PFOS(1.49) > PFNA(0.81) > PFHxS(0.45) > PFOA(0.39). The sorption kinetics of PFDA, PFNA, PFOA, PFOS and PFHxS onto soil were described by a biexponential adsorption model, suggesting that a fast transport into the surface layer of soil, followed by two-step diffusion transport into the internal water and/or organic matter of soil. Shorter times(<20hr) were required to achieve equilibrium and fraction for adsorption on solid(F1, F2) increased with perfluorinated carbon chain length and sulfonate compounds in this study. Overall, our results suggested that not only the perfluorocarbon chain length, but also the terminal functional groups are important contributors to electrostatic and hydrophobic interactions between PFCs and soils, and organic matter in soils significantly affects adsorption maximum capacity than kinetic rate.