• Title/Summary/Keyword: SSSC

Search Result 60, Processing Time 0.021 seconds

Improvement of Line Protection Methods by Dynamic Analysis on a FACTS-compensated transmission line (FACTS 보상 송전선의 동적 해석을 통한 송전선 보호 방안 개선)

  • Lim Jung-Uk;Runolfsson Thodur
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.12
    • /
    • pp.573-579
    • /
    • 2005
  • Dynamic analysis of a transmission line which is compensated by a FACTS device such as STATCOM, SSSC and UPFC is carried out in this paper and the impacts on conventional line protection methods such as the DCPM (Differential Current Protection Method) and the DPM (Distance Protection Method) are reviewed. A refined DCRM is proposed to detect faults properly regardless of the FACTS operation. The proposed method is applied to a FACTS-compensated line with a variety of faults and is verified by simulation results. An adaptive DPM on a FACTS-compensated line was proposed previously in the literature. In order to emphasize the necessity of the modified DPM, the conventional DPM is applied to a FACTS-compensated system. Significant factors such as fault types, fault locations, and fault resistances as well as FACTS device types are considered for relaying setting.

Algorithm of reactive power injection on Distributed Static Series Compensator (송전 전력 제어를 위한 분산 정지형 직렬 보상기의 무효전력 주입 기법)

  • Yoon, Hanjong;Lee, Taeyoung;Cho, Younghoon
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.214-215
    • /
    • 2017
  • Distributed Flexible AC Transmission System(D-FACTS) was proposed as a solution for weakness of FACTS device s. The D-FACTS device DSSC(Distributed Static Series Co mpensator) can provide controllable reactance compensation in transmission line such as SSSC(Static Synchronous Series Compensator). This paper introduce the algorithm of reactive power injection on DSSC and propose the method of current balancing by reactive power injection. The proposed algorithm has been verified with simulation and experiment results.

  • PDF

The Study of 80VMA UPFC operation (80MVA UPFC 운전 결과 분석)

  • Kim, S.Y.;Yoon, J.S.;Jeon, Y.S.;Park, C.S.;Yoo, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.416-418
    • /
    • 2003
  • 한국전력공사에서는 전압원 인버터형 FACTS 기기인 UFPC를 전남 강진군 강진변전소에 설치하였다. 강진 UPFC는 한전과 (주)효성이 공동으로 투자하고, 지멘스와의 기술제휴를 통해 개발하였으며, 40MVA 병럴인버터, 40MVA 직렬인버터로 구성되어 총 80MVA 용량이다. 강진 UPFC는 GTO를 이용한 3레벨 인버터 모듈 20MVA 총 4대로 구성되어 있으며, STATCOM, SSSC, UPFC의 3가지 운전모드를 갖는다. 현재 병렬인버터는 강진 모선전압 제어, 직렬인버터는 강진-장흥간의 조류제어에 기여하며, 상용운전 중이다. 본 논문에서는 강진 UPFC의 운전결과 및 효과를 분석하였다.

  • PDF

Dynamic Characteristic Analysis of Novel Unified Power Flow Controller Using 3-Level Half-Bridge Inverter Modules (3-레벨 반브리지 인버터로 구성된 새로운 UPFC의 동특성 분석)

  • Baek, Seung-Taek;Soh, Yong-Chul;Han, Byung-Moon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.3
    • /
    • pp.116-121
    • /
    • 2004
  • This paper proposes a novel UPFC based on 3-level Half-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC, assuming that the UPFC is connected with the 138-kV transmission line of one-machine-infinite-bus power system. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of 3-level Half-bridge modules.

Study on Power Capacity Design of Active Controller for Distribution System Reconfiguration (배전망 재구성을 위한 능동 제어기 용량선정 연구)

  • Jeong, Da-Woom;Kim, Soo-Yeon;Park, Sung-Jun;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.328-329
    • /
    • 2019
  • 급격한 전력 수요의 증가로 인한 송전 용량 부족 시, 수용가에 원활한 전력 공급을 위하여 타 배전 선로와 연계 운전을 통해 부족한 전력 공급이 이루어진다. 이때 각각의 연계 지점 전압 정보가 불일치할 시, 선로에 돌입 전류 및 순환 전류가 야기되어 안정적인 전력 공급에 어려움이 있다. 문제 대책 방안으로 선로에 SSSC(Static Synchronous Series Compensator) 기반의 능동 제어기를 구축하여 배전망을 재구성함으로써, 전압 안정도를 향상시킨다. 따라서 본 논문에서는 제어기의 최적화된 용량 선정을 통하여 효율적인 연계 운영을 시행하였으며, 제안하는 이론을 Simulation Tool을 통해 검증하였다.

  • PDF

Modeling and Analysis of the KEPCO UPFC System by EMTDC/PSCAD

  • Yoon, Jong-Su;Kim, Soo-Yeol;Chang, Byung-Hoon;Lim, Seong-Joo;Choo, Jin-Boo
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.3
    • /
    • pp.148-154
    • /
    • 2003
  • This paper describes the development of KEPCO's 80MVA UPFC electromagnetic transient model and the analysis of its performance in the actual Korean power system. KEPCO's 80MVA UPFC is currently undergoing installation and will be ready for commercial operation from the year 2003. In order to apply a new FACTS device such as the UPFC to the actual power system, the utility needs, in advance, both load flow stability studies and transient studies. Therefore, KEPRI, the research institute of KEPCO, developed a detailed transient analysis model that is based on the actual UPFC S/W algorithm and H/W specifications. This simulation model is implemented by an EMTDC/PSCAD package. The results of the simulation show the effectiveness of UPFC operation in the KEPCO power system.

Development of a Real-Time Water Quality Monitoring System using Coastal Passenger Ships and PCS Telemetry

  • Jin, Jae-Youll;Park, Jin-Soon;Lee, Jong-Kuk;Park, Kwang-Soon;Lee, Dong-Young;Yum, Ki-Dai
    • Ocean and Polar Research
    • /
    • v.21 no.2
    • /
    • pp.117-126
    • /
    • 1999
  • To meet increasing needs for environmentally sustainable management of coastal area, there has been compelling pressure to establish a cost-effective and long-term coastal water quality (CWQ) monitoring system. A remote CWQ monitoring system, STAMP, has been developed and is in operation along the route between Kyema harbor and Anma Island in the southwestern coastal area of Korea. STAMP uses a PCS phone as a telemetry unit to transmit acquired data for monitoring general water quality parameters, and a routinely operating coastal passenger ship or car ferry. STAMP has various merits of low-cost operations; long-term monitoring with secure instrumentation; and stable real-time telemetry of acquired data with-out the loss and noise. It is expected that the system will serve as a very useful tool in the CWQ managing programs of Korea taking the advantage of many coastal passenger ships in various routes including the ships departing from the coastal industrial cities. The acquired data compiled on suspended surface sediment concentrations (SSSC) will be also valuably helpful in understanding the sediment budget across the routes of the vessel.

  • PDF

Study on Capacity Design of Active Phase Controller for Distribution Line Reconfiguration (배전선로 재구성을 위한 능동위상제어기의 용량 선정 연구)

  • Jeong, Da-Woom;Kim, Soo-Yeon;Park, Sung-Jun;Kim, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.5
    • /
    • pp.369-375
    • /
    • 2020
  • Distribution energy resources have been increasing in recent years. However, output power is limited for distribution network stability. This study proposes an active distribution network that can reconfigure distribution lines by using an active phase controller. A conventional distribution network has a fixed structure, whereas an active distribution network has a variable structure. Therefore, the latter can increase the output power of distribution energy resources and decrease the overload of distribution line facilities. An active phase controller has two operation modes for minimizing circulating current during dynamic reconfiguration. In this study, voltage and current control algorithms are proposed for active phase controllers. The simulation of the proposed methods for active phase controllers is performed using PSIM software.

Circulating Current Reduction Method during Distribution Network Dynamic Reconfiguration using Active Phase Controller (능동위상제어기를 이용한 배전선로 자율 재구성 시 순환전류 감소 기법)

  • Kim, Soo-Yeon;Jeong, Da-Woom;Park, Sung-Jun;Kim, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.25 no.1
    • /
    • pp.6-12
    • /
    • 2020
  • In recent years, the demand for the distribution of energy resource has been increasing. However, the output power is limited by the stability of the distribution network. This study proposes an active distribution network that can reconfigure the distribution line using an active phase controller. The conventional distribution network has a fixed structure, whereas the proposed active distribution network has a variable structure. Therefore, the active distribution network can increase the output power of the distribution energy resource and reduce the overload of distribution line facilities. The active phase controller has two operation modes to minimize the circulating current during dynamic reconfiguration. In this study, the voltage and current control algorithms are proposed for the active phase controller. The proposed method for the active phase controller is simulated via PSIM simulation.

Modeling, Simulation and Fault Diagnosis of IPFC using PEMFC for High Power Applications

  • Darly, S.S.;Vanaja Ranjan, P.;Justus Rabi, B.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.4
    • /
    • pp.760-765
    • /
    • 2013
  • An Interline Power Flow Controller (IPFC) is a converter based controller which compensates and balance the power flow among multi-lines within the same corridor of the multi-line subsystem. The Interline Power Flow Controller consists of a voltage source converter based Flexible AC Transmission System (FACTS) controller for series compensation. The reactive voltage injected by individual Voltage Source Converter (VSC) can be controlled to regulate active power flow in the respective line in which one VSC regulates the DC voltage, the other one controls the reactive power flows in the lines by injecting series active voltage. In this paper, a circuit model for IPFC is developed and simulation of interline power flow controller is done using the proposed circuit model. Simulation is done using MATLAB Simulink and PSPICE. The results obtained by MATLAB are compared with the results obtained by PSPICE and compared with theoretical values.