SR-Ivocap resin system의 물리적 특성과 체적 안정성에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES AND VOLUMETRIC STABILITY OF SR-IVOCAP RESIN SYSTEM)

  • 은성식;권혁신;정재헌
    • 대한치과보철학회지
    • /
    • 제36권3호
    • /
    • pp.453-467
    • /
    • 1998
  • This study helps to clarify conflicting reports by comparing the physical properties and accuracy of complete denture processed by the pack and press technique, continuous- pressure injection technique(SR-Ivocap system) and Mark press technique. The 6 different specimens have been evaluated using the SEM, Impact test, DSC (Differential Scanning Calorimetry) and DMTA (Dynamic Mechanical Thermal Analysis). Each sample was made of SR-Ivocap resin and QC-20 resin by different processing methods. The results were as follows ; 1. As the result of the observation on the fracture surface of resin by use of SEM, sample SR-Ivocap resin cured by continuous pressure injection method showed the most homogeneous structure. This is why molecules in SR-Ivocap resin have no orientation. 2. As the result of the Impact test in order to measure the deformity, fracture energy and impact resistance of resin, the samples with QC-20 acrylic resin and SR-Ivocap resin cured by continuous pressure injection method were exellent. 3. In consequence of measuring ${\alpha}$-glass transition temperature by use of DSC on the basis of temperature change, the glass transition temperatures of sample QC-20 resin cured by pack and press method and sample SR-Ivocap resin cured by continuous pressure injection method were very similar. Thus volumetric stability could not be evaluated only by glass transition temperature. 4. In comparing volumetric stability data by DMTA, the glass transition temperature(Tg) showed $137.88^{\circ}C$ at sample QC-20 resin cured by pack and press method and $139.78^{\circ}C$ at sample SR-Ivocap resin cured by continuous pressure injection method. Therefore sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in the dimensional stability at high temperature. 5. In comparing storage modulus data by DMTA, the storage modulus of sample SR-Ivocap resin cured by continuous pressure injection method was higher than that of sample QC-20 resin cured by pack and press method. So. sample SR-Ivocap resin cured by continuous pressure injection method seems to be superior to sample QC-20 resin cured by pack and press method in impact strength.

  • PDF

상악 완전 무치악 환자에서 CM LOC® Pekkton® attachment를 이용한 임플란트 유지 피개의치 수복 증례 (Implant-retained overdenture with CM LOC® Pekkton® in maxillary edentulous patient)

  • 홍문기;신수연
    • 구강회복응용과학지
    • /
    • 제33권4호
    • /
    • pp.321-328
    • /
    • 2017
  • 무치악은 총의치나 임플란트 보철물로 수복이 가능하며 임플란트를 이용한 피개의치는 총의치보다 유지와 안정이 우수하고, 임플란트 고정성 보철물에 비해 저렴하고 심미적이다. CM $LOC^{(R)}$ $Pekkton^{(R)}$ 어태치먼트는 여자부가 poly-ether-ketone-ketone으로 마모저항성이 뛰어나다. 한편, SR Ivocap system은 가압주사성형법으로 의치의 수직고경 변화가 적고 강도가 우수하다. 본 증례에서 상악은 4개의 임플란트 식립 후 CM $LOC^{(R)}$ $Pekkton^{(R)}$ 어태치먼트와 SR Ivocap system을 이용한 임플란트 유지 피개의치를, 하악은 가철성 국소의치를 제작하였고 심미적 및 기능적으로 만족스러운 결과를 얻었기에 이를 보고하는 바이다.

Reverse Engineering 기법의 레이저 스캐너를 이용한 의치상의 정확도에 관한 연구 (DIMENSIONAL ACCURACY OF DENTURE BASE USING LASER SCANNER OF REVERSE ENGINEERING TECHNIC)

  • 이시혁;장익태;임순호
    • 대한치과보철학회지
    • /
    • 제37권2호
    • /
    • pp.167-184
    • /
    • 1999
  • The purpose of this study was to evaluate and compare the at of denture bases processed by injection pressing technic using laser scanner of reverse engineering technic. The auther duplicated 20 maxillary edentulous models and 20 mandibular edentulous models, which were scanned on HYSCAN 45C 3D BCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co. U.S.A.) software program. After 40 dentures were cured by PERform Inkovac system, SR-Ivocap system, Palajet system, and Sulfon system, they were stored in water at room temperature fir 24 hours. The dentures were scanned on HYSCAN 45C 3D SCANNER(Hymarc Co., Canada). The scanned data were stored in the personal computer using SURFACER (Imageware Co., U.S.A.) software program. By overlapping two images using the same program, the fit between two surfaces was scaled by positive and negative errors. The obtained results were as follows 1. In the upper denture, most of the positive errors occurred on the lingual side of anterior alveolar ridge and the negative errors were on the flange of denture bases. 2. In the lower denture, most of the positive errors occurred on the inner side of lingual flange and the negative errors were on the border of anterior labial flange areas, 3. There were no statistical differences among the positive errors of the four types of injection denture curing methods and also no statistical differences between negative errors except only in negative maximum errors. 4. In PERform system and SR-Ivocap system, they have the tendency of inaccurate at of lower denture bases comparing to that of upper denture bases. 5. The negative error scales were greater than the positive error scales in all types of injection denture curing methods.

  • PDF

지속적 가압 주사식 열중합 의치상 레진에 대한 열중합, 자가중합 및 광중합 레진의 결합력에 관한 비교분석 (COMPARATIVE TENSILE BOND STRENGTH OF HEAT-CURED, COLD-CURED, AND LIGHT CURED DENTURE BASE RESINS BONDED TO CONTINUOUS-PRESSURE INJECTION TYPE DENTURE BASE RESIN)

  • 황승우;정문규
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.385-393
    • /
    • 1993
  • Injection processing of denture base resin was introduced by Pryer in 1942, in an attempt to reduce processing shrinkage. More recently a continuous-pressure injection type technique has been developed (SR-Ivocap, Ivoclar AG, Schaan, Liechtenstein.), and it reduced processing error and increased resin density. The purpose of this study was to compare tensile bond strength of heat-cured, cold-cured, and light-cured denture base resin bonded to continuous-pressure injection type resin. To know it, 60 cylindrical resin specimens were fabricated, and tensile bond strength were measured. The results were as follows : 1. The mean tensile bond strength bonded to continuous-pressure injection type resin was lower than bonded to conventional heat cured resin. But tensile bond strength of conventional heat cured resin bonding with light cured resin was lower than continuous-pressure injection type resin. 2. Of the tensile bond strength bonded to continuous-pressure injection type resin, tensile bond strength bonding with continuous-pressure injection type resin was the greatest(but not significantly different from bonding with conventional heat cured resin), followed by cold-cured, light-cured resin. 3. Of the tensile bond strength bonded to conventional heat cured resin, tensile bond strength bonding with conventional heat cured resin was the greatest and followed by continuous-pressure injection type resin, cold-cured resin, light-cured resin. According to these results, bonding of continuous-pressure injection type resin with conventional heat cured resin or continuous-pressure injection type resin is acceptable, but bonding with light-cured resin is questionable.

  • PDF

Comparing accuracy of denture bases fabricated by injection molding, CAD/CAM milling, and rapid prototyping method

  • Lee, Suji;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권1호
    • /
    • pp.55-64
    • /
    • 2019
  • PURPOSE. The accuracy of denture bases was compared among injection molding, milling, and rapid prototyping (RP) fabricating method. MATERIALS AND METHODS. The maxillary edentulous master cast was fabricated and round shaped four notches were formed. The cast was duplicated to ten casts and scanned. In the injection molding method, designed denture bases were milled from a wax block and fabricated using SR Ivocap injection system. Denture bases were milled from a pre-polymerized block in the milling method. In the RP method, denture bases were printed and post-cured. The intaglio surface of the base was scanned and surface matching software was used to measure inaccuracy. Measurements were performed between four notches and two points in the mid-palatal suture to evaluate inaccuracy. The palatine rugae resolution was evaluated. One-way analysis of variance was used for statistical analysis at ${\alpha}=.05$. RESULTS. No statistically significant differences in distances among four notches (P>.05). The accuracy of the injection molding method was lower than those of the other methods in two points of the mid-palatal suture significantly (P<.05). The degree of palatine rugae resolution was significantly higher in the injection molding method than that in other methods (P<.05). CONCLUSION. The overall accuracy of the denture base is higher in milling and RP method than the injection molding method. The degree of fine reproducibility is higher in the injection molding method than the milling or RP method.

위상이동 형상측정법을 이용한 의치 중합 방법에 따른 적합도 검사 (FITNESS TEST USING THE PHASE-SHIFTING PROFILOMETRY ACCORDING TO THE DENTURE CURING METHODS)

  • 이청희;조광헌;최부병
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.474-493
    • /
    • 1999
  • According to repeated measurements and correction procedures, the accuracy of the phase-shifting profilometry was developed. At first, after 20 final models for maxillary complete denture were duplicated , the mucosa sur-faces of models were measured with the phase-shifting proflometry and each mirror view of these was calibrated. Maxillary casts were divided into 4 groups of 5 casts per each, and wax dentures with 2 sheets of baseplate wax and artificial teeth were made and then cured according to the curing method of each group. Group I ; quick curing with QC-20 acrylic resin Group II ; 9 hour curing with QC-20 acrylic resin Group III ; SR-Ivocap system Group IV ; metal base and quick curing with QC-20 acrylic resin. After curing, polishing, and storing at $37^{\circ}C$ in saline for 30 days, the forms of the impression surface of the dentures were measured with the phase-shifting profilometry. Then, the impression surface form of each denture was placed in the optimal position of com-parison with the mirror view of the same final cast. The amount and direction of distortion of each denture was analyzed and the effects of polishing and storage in each denture were compared, The obtained results were as follows : 1. In Group I, the denture was observed as the appearance distorted in the opposite direction of the mucosa and the postero-lateral part of palatal portion of the denture was observed as the appearance separated from the mucosa. Also, the buccal flanges of the denture were observed as the appearance distorted in the direction of the mucosa. 2. In Group II, the postero-lateral part of palatal portion of the denture was observed as the appearance separated slightly from the mucosa. The bilateral buccal flanges of denture were observed as the appearance distorted severely in the direction of the mucosa. 3. In Group III the bilateral part of the residual ridge crest portions and the buccal flanges of the denture were observed as the appearance distorted in the direction of the mucosa, and specially, the buccal flanges of the maxillary tuberosities were distorted severely. 4. In Group IV, the acrylic resin base of the buccal portion of the denture was observed as the appearance distorted in the opposite direction of the mucosa. 5. The phase-shifting profilometry, done with repeated measurements and correction procedures, was effective in comparing the amount and direction of distortion at every position after the laboratory work and the delivery of maxillary complete denture.

  • PDF