• Title/Summary/Keyword: SPT-N값

Search Result 39, Processing Time 0.021 seconds

Energy Correction and Use of Standard Penetration Test N Value (표준관입시험 N값의 올바른 보정 및 사용)

  • 이우진;유재명;류동헌
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2001.10a
    • /
    • pp.241-264
    • /
    • 2001
  • Due to the variation of equipments and test procedure, level of energy transferred to split spoon sampler varies and thus measured N value. Since the properties and parameters are estimated from empirical correlations related to N value, the correction of N value with respect to specific energy level is essential. Factors affecting N value are discussed and the results of previous studies on energy correction of SPT N value is reviewed. Part of results from joint research works with KHC are presented and the range of energy levels for the hammer and release system typically used in Korea is suggested.

  • PDF

Study on Correlation between Large Earthquake-Induced Underground Structure Uplift and Geological Settings (대지진에 의한 지하구조물 부상과 지질학적 특성의 상관성 연구)

  • Kang, Gi-Chun;Kim, Ji-Seong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.15 no.4
    • /
    • pp.9-16
    • /
    • 2016
  • During the 2004 Niigata-ken Chuetsu, Japan, earthquake, more than 1,450 underground structures, known as sewer manhole, were uplifted up to 1.5m in Nagaoka and Ojiya city. The uplift damage can be a serious matter because they not only hinder the flow of wastewater systems, as a part of lifeline systems, but also disturb traffic flows. For restoration works, an open-cut investigation of damaged wastewater system was conducted by the Nagaoka city government. The results from the investigation compiled valuable data sets for buried pipeline damage due to earthquakes. In the present study, the factors affecting the uplift amount of the underground structure is investigated by using the data sets which include locations of damaged sections and inclination of pipeline before and after the earthquake and the SPT borehole logs in the affected area. Correlation analysis between the underground structure uplift and the geological settings in the affected area revealed that ground water depth and original subsoil, including thickness of clay layer, SPT N-value and fill thickness are the key parameters for the uplift phenomenon.

Cross-Validation of SPT-N Values in Pohang Ground Using Geostatistics and Surface Wave Multi-Channel Analysis (지구통계기법과 표면파 다중채널분석을 이용한 포항 지반의 SPT-N value 교차검증)

  • Kim, Kyung-Oh;Han, Heui-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.393-405
    • /
    • 2020
  • Various geotechnical information is required to evaluate the stability of the ground and a foundation once liquefaction occurs due to earthquakes, such as the soil strength and groundwater level. The results of the Standard Penetration Test (SPT) conducted in Korea are registered in the National Geotechnical Information Portal System. If geotechnical information for a non-drilled area is needed, geostatistics can be applied. This paper is about the feasibility of obtaining ground information by the Empirical Bayesian Kriging (EBK) method and the Inverse Distance Weighting Method (IDWM). Esri's ArcGIS Pro program was used to estimate these techniques. The soil strength parameter of the drilling area and the level of groundwater obtained from the standard penetration test were cross-validated with the results of the analysis technique. In addition, Multichannel Analysis of Surface Waves (MASW) was conducted to verify the techniques used in the analysis. The Buk-gu area of Pohang was divided into 1.0 km×1.0 km and 110 zones. The cross-validation for the SPT N value and groundwater level through EBK and IDWM showed that both techniques were suitable. MASW presented an approximate section area, making it difficult to clearly grasp the distribution pattern and groundwater level of the SPT N value.

A Study on the Skin Friction of Piles Driven into Residual Soils (풍화잔류토 지반에 타설된 말뚝의 주면마찰 특성 연구)

  • 이명환;이인모
    • Geotechnical Engineering
    • /
    • v.8 no.2
    • /
    • pp.21-30
    • /
    • 1992
  • Though the pile skin friction can take substantial amount of load carrying capacity, it has often been ignored in the design. Even when the pile skin friction is taken into consideration, it is questionable about the reliability of estimating it. It has been even worse in Korea. since in most cases the available information is only the SPT N values and not much information has been known about the correlation between N value and the pile skin friction in residual soils. With SPLT (Simple Pile Loading Test) it is possible to measure the pile skin friction separately from the tip resistance. In this research, results of the measured pile skin friction in residual soils are analysed. And a new design correlation based on SPT N value is proposed.

  • PDF

Numerical Simulation of Ground Expansion Induced by Pulse Discharge Technology (펄스 방전 기술에 의한 지반 확공 현상 수치해석 모사)

  • Park, Hyun-Ku;Lee, Seung-Rae;Kim, Seon-Ju;Cho, Gyu-Yeon
    • Journal of the Korean Geotechnical Society
    • /
    • v.26 no.3
    • /
    • pp.25-34
    • /
    • 2010
  • In the present paper, a numerical study was carried out to simulate ground expansion induced by an application of pulse discharge technology. Based on laboratory pulse discharge tests, the characteristics of shockwave were investigated, and then the laboratory tests were numerical1y simulated using underwater explosion model implemented in a coupled acoustic-structural finite element analysis. In addition, for clayey soils, the expansion of ground was also studied using soil properties obtained from empirical correlations with SPT N values. It was found that the calculation results well agreed with the field test results.

Study on the Fractures Types of PHC Pile by Impact Load of Follower (보조말뚝의 충격하중에 의한 PHC말뚝의 파손유형 고찰)

  • Seo, Dong-Nam;Choi, Sang-Ho;Kim, Jin-Sik;Kim, Min-Kab;Lee, Dong-Hyeon;Cho, Seong-Jun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.144-145
    • /
    • 2021
  • This study analyzed the cases of cracks in piles due to the use of followers under construction conditions where water exists inside the piles, and confirmed whether the piles were cracked through a field test simulating the construction conditions in which water pressure inside the piles was generated by a hammer. According to the construction case, under the construction condition where the pile length is 20% to 30% shorter than the drilled length, about 80% cracks occur, so there is a high possibility of cracking due to water inside the pile. A field test was conducted to confirm the type of pile failure due to hammer under the construction condition in which water exists inside the pile. The pile head was not destroyed by the compressive load, and one or more longitudinal cracks occurred along the PC steel wire. The closed end pile generates water pressure by hammer. the follower and cushion(compression plywood) must be drilled at least 0.4D. It is expected that improved quality control will be possible as the water pressure inside the pile is reduced.

  • PDF

Characteristics of Undrained Shear Strength and Development of Modified SPT on Very Soft Ground in Korea (국내 초연약지반의 비배수전단강도 특성 및 개량표준관입시험기 개발)

  • Jung, Hyuksang;Cho, Changkoo;Chun, Byungsik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.6
    • /
    • pp.105-115
    • /
    • 2009
  • In this study, SPT, FV, and CPT tests were performed at five very soft grounds in southern coast of Korea to characterize the $S_u$ of very soft ground. In addition, a new modified SPT that is applicable to very soft ground was developed. Tests results showed that in very soft ground (N<2), the $S_u$ was lower than 12.5 kPa using the empirical N-Su correlation, and lower than 50 kPa and 65 kPa using vane shear test and CPT, respectively. It was shown that the results of in-situ tests were higher than those estimated from the N-Su correlation, and it was also demonstrated that the range of estimated $S_u$ was quite wide. New correlations that relate the modified SPT $N_m$ with Su from FV and CPT were developed, which are $S_u=1.76N_m-10.47$ and $S_u=1.82N_m-9.71$, respectively.

  • PDF

Driveability and Bearing Capacity Characteristics Analysis of 590 MPa Grade High Strength Steel Pipe Pile at Songdo Area through Dynamic Load Tests (동재하시험결과 분석을 통한 송도지역 590MPa급 고강도 강관말뚝의 항타관입성 및 지지력 특성 분석)

  • La, Seung-Min;Hong, Bong-Kyun;Yoo, Han-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.81-90
    • /
    • 2011
  • Domestic usage of high strength steel for pile has been limited to steel with yield strength (YS) of 490 MPa. However, design and construction cases abroad show beneficial usage of steel pipe with YS ranging in 500~700 MPa. In this study, YS 590 MPa steel pipe has been tested for driven pile foundation in Songdo area. Pile dynamic analysis (PDA) was carried out for 18 piles of which 16 piles have been reviewed for comparison of the PDA test results with those of GRLWeap analysis using SPT N value. Back analysis of PDA analysis was also carried out to narrow the deviation of standard SPT N value used in GRLWeap analysis. A regression equation is suggested for the shaft and toe resistance according to SPT N values for future GRLWeap analysis that can be used in the designing stage at Songdo area.

Applicability of Bearing Capacity for Single Drilled Shaft Using Empirical equation based on Ground Condition (토질특성에 따른 현장타설말뚝 지지력 산정 경험식의 적용성)

  • Kim, Daehyeon;Jeong, Sangguk
    • Journal of the Korean Geosynthetics Society
    • /
    • v.18 no.4
    • /
    • pp.167-180
    • /
    • 2019
  • Friction piles are being constructed in Southeast Asia (Myanmar, Cambodia, Vietnam, etc.) where the soft ground is deep, and many cases of friction piles are accumulated in terms of experience. In this study, we used the results of four static load test and load transfer test conducted in Myanmar sites to analyze the skin friction of soil layer. In addition, we proposed a relationship chart with skin friction measured in the N-value of Standard Penetration Test (SPT) and the load transfer test result of the single drilled shaft. In the case of Myanmar sites, the range of soil layers was deeper than domestic sites, so the conventional formula of skin friction using the N-value of SPT is different from domestic sites. In sandy layer, fs = 0.096 N in Myanmar sites showed a similar result of the domestic fs = 0.106 N. In clayey layer, fs = 0.315 N, in Myanmar sites showed about 5.0 times higher than the domestic fs = 0.062 N. The results of this study are based on limited data. Therefore, if we analyze the results of more load transfer tests, we can suggest a conventional formula for skin friction according to the N-value. It is expected to be used as important basic data in the future.

Analysis of Pile Head Lateral Load-Deflection Behavior of Steel-Concrete Composite Drilled Shafts (강관합성 현장타설말뚝 머리의 수평하중-변위 거동 분석)

  • Lee, Yong-An;Chung, Moon-Kyung;Park, Jae-Hyun;Lee, Ju-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.12
    • /
    • pp.97-106
    • /
    • 2011
  • To analyze the lateral load-deflection behavior of steel-concrete composite drilled shafts, a series of lateral pile load tests were performed. The test results were compared with the results from various analytical methods for lateral pile behaviors using the coefficients of subgrade reaction ($k_h$) estimated by pressuremeter test (PMT) and standard penetration test (SPT). As a result, it was found that the analytical methods using the $k_h$ estimated by SPT N value were not suitable for evaluating the pile head lateral load-deflections of the piles within the allowable deflection. However, the methods using the $k_h$ calculated from PMT were able to represent the initial lateral behavior at the head of the piles fairly well. Also, the method by the pressuremeter curve, which was applied directly to the p-y curve of the piles, offered a reasonable lateral behavior estimation by applying the correction factor to the pile materials.