• Title/Summary/Keyword: SPS500-20

Search Result 6, Processing Time 0.023 seconds

Effect of Space Holder Content on Pore Size and Distribution in HA/β-TCP Composites Consolidated by SPS (SPS로 제조된 HA/β-TCP 복합재의 기공의 크기와 분포에 미치는 지지체 량의 영향)

  • Lee, Tack;Woo, Kee-Do;Kang, Dong-Soo;Lee, Hae-Cheol;Jang, Jun-Ho
    • Korean Journal of Materials Research
    • /
    • v.25 no.4
    • /
    • pp.165-170
    • /
    • 2015
  • Ceramics biomaterials are useful as implant materials in orthopedic surgery. In this study, porous HA(hydroxyapatite)/${\beta}$-TCP(tricalcium phosphate) composite biomaterials were successfully fabricated using HA/${\beta}$-TCP powders with 10-30 wt% $NH_4HCO_3$ as a space holder(SH) and $TiH_2$ as a foaming agent, and MgO powder as a binder. The HA/${\beta}$-TCP powders were consolidated by spark plasma sintering(SPS) process at $1000^{\circ}C$ under 20 MPa conditions. The effect of SH content on the pore size and distribution of the HA/${\beta}$-TCP composite was observed by scanning electron microscopy(SEM) and a microfocus X-ray computer tomography system(SMX-225CT). These microstructure observations revealed that the volume fraction of the pores increased with increasing SH content. The pore size of the HA/${\beta}$-TCP composites is about $400-500{\mu}m$. The relative density of the porous HA/${\beta}$-TCP composite increased with decreasing SH content. The porous HA/${\beta}$-TCP composite fabricated with 30%SH exhibited an elastic modulus similar to that of cortical bone; however, the compression strength of this composite is higher than that of cortical bone.

The Implementation of photovoltaic simulator system with ATEasy Tool and PPS (ATEasy Tool과 PPS를 이용한 태양광 시뮬레이터 시스템 구현)

  • Kim, Sang-Mo;Jang, Ki-Young;Kim, Ki-Hyun;Lee, Seung-Hee;Yu, Gwon-Jong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.103-106
    • /
    • 2009
  • In this paper, the implemented photovoltaic array simulator is the power supply based on a common photovoltaic characteristic. This simulator is consisted of a common DC power supply and PC for controlling output. User can select the number of PV modules and solar radiation energy and then can get output whatever user wants. This simulator is a very helpful system to PV generating test and unexpensive than the existing PV simulators.

  • PDF

아파트 거주자의 변인에 따른 주거환경 만족도의 차이에 대한 연구 -부동산 관련 창업자를 위한 소비자 정보제공을 목적으로-

  • Jin, Seon-Jin;Ha, Gyu-Su
    • 한국벤처창업학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.81-108
    • /
    • 2009
  • 본 연구는 서울지역 아파트 거주자를 대상으로 거주자의 주거환경 만족도, 인구통계학적 특성과 주거형태에 따른 주거환경 만족에 차이, 그리고 주거환경 만족도간에는 상관관계가 있는지를 알아보고자 하였다. 이를 위해 서울지역 아파트 거주자 500명을 대상으로 2009년 9월 1일부터 2009년 9월 20일까지 조사를 실시하여 자료를 수집하였다. 수집된 자료는 SPSS를 이용하여 빈도 백분율, 평균, 표준편차, t-test, ANOVA, Duncan Multiple Ranger's Test 등을 계산하였다. 본 연구의 결과는 다음과 같다. 첫째, 서울지역 아파트 거주자의 주거환경만족도는 중간이상의 수준을 나타냈으며, 사회환경 중 단지질서 만족도가 가장 높았다. 둘째, 거주자 변인에 따른 시설환경 만족도는 유의한 차이가 있었다. 셋째, 거주자 변인에 따른 근린, 사회환경 만족도는 유의한 차이가 있었다. 4) 주거환경 만족도 변수상호간에는 주택환경 만족도와 단지 내 환경 만족도, 단지 내 환경 만족도와 관리상태 만족도간 밀접한 상관관계가 있었다.

  • PDF

A Study on the Development of a Work Operation Process Chart for Smart Distribution Board Fabrication (스마트 분전반 제작을 위한 작업 공정도 개발에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.3
    • /
    • pp.15-20
    • /
    • 2017
  • This study presented the strength of the materials and parts for smart distribution board fabrication, and developed a work operation process chart for smart distribution board fabrication. This work operation process chart for smart distribution board fabrication complied with SPS-KEMC regulations, and the applicable range and object are less than 1,000 V and 1,000 Hz for the AC distribution board and less than 1,500 V for the DC distribution board. The power supply is 3 phase 4 wires ($3{\Phi}$ 4W), divided into a single phase circuit and a 3 phase circuit. In addition, the circuit was configured so that the leakage current flowing through the distribution line of the load could be monitored in real time by using the sensor module installed at the rear end of the circuit breaker. Therefore, the administrator can easily find the risk factor of the load since engineer can check the leakage current of each distribution line. In addition, if a leakage current greater than standard value flows, it is possible to generate an alarm against a short circuit and cut off the leakage current. The work operation process chart for the smart distribution board fabrication consists of the following steps: raw and subsidiary materials, sheet metal work, tube making, welding, painting, busbar fabrication, assembly and wiring, product inspection, shipment, etc. Moreover, symbols, ${\Delta}$, ${\nabla}$, ${\bigcirc}$, ${\Rightarrow}$, etc. were used according to the type of work and work progress so that workers can easily understand the progress of the work.

Feasibility Evaluation of Micro Hole Drilling and the Material Properties of Si3N4/hBN Ceramic with hBN Contents (hBN의 첨가량에 따른 Si3N4/hBN 세라믹의 재료특성 및 마이크로 홀가공 유용성 평가)

  • Park, Kwi-Deuk;Go, Gun-Ho;Lee, Dong-Jin;Kim, Jin-Hyeong;Kang, Myung Chang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.16 no.1
    • /
    • pp.36-41
    • /
    • 2017
  • In this paper, $Si_3N_4/hBN$ ceramics with various hexagonal boron nitride (hBN) contents (0, 10, 20, or 30 wt%) were fabricated via spark plasma sintering (SPS) at $1500^{\circ}C$, 50MPa, and 10m holding time. The material properties such as the relative density, hardness, and fracture toughness were systematically evaluated according to the hBN content in the $Si_3N_4/hBN$ ceramics. The results show that relative density, hardness, and fracture toughness continuously decreased as the hBN content increased. In addition, peak-step drilling (with tool diameter $500{\mu}m$) was performed to observe the effects of hBN content in micro-hole shape and cutting force. A machined hole diameter of $510{\mu}m$ (entrance) and stable cutting force were obtained at 30 wt% hBN content. Consequently, $Si_3N_4/30wt%$ hBN ceramic is a feasible material upon which to apply semi-conductor components, and this study is very meaningful for determining correlations between material properties and machining performance.

The Frequency of Chromosomal Aberrations of Peripheral Lymphocytes according to Radiation Dose and Dose Rate (선량 및 선량률 변화에 따른 말초혈액 임파구의 염색체 이상의 빈도)

  • Jeong Tae Sik;Baek Heum Man;Shin Byung Chul;Moon Chang Woo;Kim Mi Hyang;Lee Yong Hwan;Yum Ha Yong
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.138-149
    • /
    • 2000
  • Purpose : It was studied that the relationship between radiation dose, dose rate and the frequency of chromosomal aberrations in peripheral lymphocytes. Methods and Materials : Peripheral lymphocytes were irradiated in vitro with 6 MeV X-ray at dose ranges from 50 cGy to 800 cGy. The variations of the frequency of chromosomal aberrations were observed according to different radiation dose rate from 20 cGy/min to 400 cGy/min at constant total dose of 400 cGy which it was considered as factor to correct biological radiation dose measurement. Results : The yields of lymphocytes with chromosomal aberrations (dicentric chromosome, ring chromosome, acentric fragment pairs) are 0% at 50 cGy, 9% at 100 cGy, 20% at 200 cGy, 27% at 300 cGy, 55% at 400 cGy, 88% at 600 cGy, and 100% at 800 cGy. The value of Ydr is 0.000 at 50 cGy, 0.093 at 100 cGy, 0.200 at 200 cGy, 0.354 at 300 cGy, 0.612 at 400 cGy, 2.040 at 600 cGy, and 2.846 at 800 cGy. The relationship between radiation (D) and the frequency of dicentrlc chromosomes and ring Chromosomes (Ydr) can be expressed as Ydr=0.188${\times}$10$^{-2}$ D/Gy+0.422${\times}$10$^{-4}$/Gy$^{2}$${\times}$D$^{2}$ The Value of Qdr is 0.000 at 50 cGy, 1.000 at 100 cGy, 1.000 at 200 cGy, 1.333 at 300 cGy, 1.118 at 400 cGy, 2.318 at 600 cGy, and 2.846 at 800 cGy. When 400 cGy is irradiated with different dose rate each of 20, 40, 60, 80, 100, 160, 240, 320, and 400 cGy/min, Ydr is each of 0.982, 0.837, 0.860, 0.732, 0.763, 0.966, 0.909, 1.006, and 0.806, and Qdr is each of 1.839, 1.555, 1.654, 1.333, 1.381, 1.750, 1.6000, 1.710, and 1.318. Conclusion : There are not the significant variations of Ydr and Qdr values according to different dose rate. And so radiation damage is influenced by total exposed radiation doses and is influenced least of all by different dose rate when it is acute single exposure.

  • PDF