• Title/Summary/Keyword: SPI system

Search Result 128, Processing Time 0.025 seconds

Acoustic screening test for laryngeal cancer (음성을 이용한 후두암의 집단선별검사)

  • 박헌수
    • Korean Journal of Bronchoesophagology
    • /
    • v.7 no.2
    • /
    • pp.161-167
    • /
    • 2001
  • Background and Objectives: Total laryngectomy is often required for advanced cases. But this operation induced the many inconvenience of basic daily life. Early diagnosis of laryngeal cancer is very important to prevent from this disastrous condition. In this point of view, mass screening test for early detection of laryngeal cancer is necessary. Screening test using voice has many advantages such as simple, less interventional. Voice collection by Automatic Response System(ARS) is comfortable and easy to got acoustic sample. Thus author tried to got the acoustic parameters which can differentiate normal, benign. and malignant laryngeal diseases and also checked the availability of parameters on neural network system. Materials and Methods: Author has evaluated the voice from 17 laryngeal cancer patients and 45 benign laryngeal disease patients who visited at Department of Otolaryngology, Pusan National University Hospital from May 1998 to April 2001, and 15 normal control. Author chose the sir Parameters (Jitt. vFo, Shim, vAm, NHR, SPI) that was thought to be related with voice collected by ARS among thirty-three parameters analysed by a Multi-Dimensional Voice Program (MDVP). Two-step neural network was used for the availability of six parameters. Results: The detection rate of normal voice by ARS voice analysis is 78.5% and detection rate of abnormal voice was 97.1 o/o. Among abnormal voice, the detection rate of benign laryngeal diseases and laryngeal cancers were 82.4 o/o, 70.6% respectively. Conclusion: Author concluded that six parameters and Matlab based neural network software may be effective in development of acoustic screening system for laryngeal cancer and further study should be necessary for development of new acoustic parameters.

  • PDF

Real-time 256-channel 12-bit 1ks/s Hardware for MCG Signal Acquisition (심자도 신호획득을 위한 실시간 256-채널 12-bit 1ks/s 하드웨어)

  • Yoo, Jae-Tack
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.11
    • /
    • pp.643-649
    • /
    • 2005
  • A heart diagnosis system adopts Superconducting Quantum Interface Device(SQUD) sensors for precise MCG(MagnetoCardioGram) signal acquisitions. Such system needs to deal with hundreds of sensors, requiring fast signal sampling md precise analog-to-digital conversions(ADC). Our development of hardware board, processing 64-channel 12-bit in 1 ks/s speed, is built by using 8-channel ADC chips, 8-bit microprocessors, SPI interfaces, and specially designed parallel data transfers between microprocessors to meet the 1ks/s, i.e. 1 mili-second sampling interval. We extend the design into 256-channel hardware and analyze the speed .using the measured data from the 64-channel hardware. Since our design exploits full parallel processing, Assembly level coding, and NOP(No Operation) instruction for timing control, the design provides expandability and lowest system timing margin. Our result concludes that the data collection with 256-channel analog input signals can be done in 201.5us time-interval which is much shorter than the required 1 mili-second period.

Real-time Monitoring System for Smoking Detection in Indoor Public Areas (실내 공공장소 흡연감지를 위한 실시간 모니터링 시스템 구현)

  • Han, Seungmin;Hong, Hyunseok;Yu, Heejin;Kim, Yonghee;Lee, Jongkyung;Gim, Jangwon;Jeong, Dongwon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2017.11a
    • /
    • pp.1267-1270
    • /
    • 2017
  • 이 논문에서는 라즈베리파이카메라를 이용하여 실내 흡연감지를 실시간으로 모니터링하는 시스템을 제안한다. 기존에 라즈베리파이에 가스센서를 SPI 통신으로 연결하여 실외 흡연감지 기능을 제공하는 시스템에 대한 연구가 진행되었다. 그러나 기존의 시스템은 부정확한 센서 값의 원인과 흡연이 감지되어도 흡연자를 조치하는 부분에 대한 문제점이 있다. 이 논문에서 제안하는 것은 연기센서, 가스센서를 시리얼통신으로 연결하여 공공장소 실내 흡연여부를 판단해 라즈베리파이카메라를 사용하여 실시간으로 흡연감지 하는 시스템을 제안한다. 이 논문에서 제안 시스템은 공공장소에서 실내흡연을 감지하고 이미지조회기능으로 보다 더 신뢰성있는 흡연감지 시스템에 대해 기대된다.

Analog-Digital Signal Processing System Based on TMS320F28377D (TMS320F28377D 기반 아날로그-디지털 신호 처리 시스템)

  • Kim, Hyoung-Woo;Nam, Ki Gon;Choi, Joon-Young
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.14 no.1
    • /
    • pp.33-41
    • /
    • 2019
  • We propose an embedded solution to design a high-speed and high-accuracy 16bit analog-digital signal processing interface for the control systems using various external analog signals. Choosing TMS320F28377D micro controller unit (MCU) featuring high-performance processing in the 32-bit floating point operation, low power consumption, and various I/O device supports, we design and build the proposed system that supports both 16-bit analog-digital converter (ADC) interface and high precision digital-analog converter (DAC) interface. The ADC receives voltage-level differential signals from fully differential amplifiers, and the DAC communicates with MCU through 50 MHz bandwidth high-fast serial peripheral interface (SPI). We port the boot loader and device drivers to the implemented board, and construct the firmware development environment for the application programming. The performance of the entire implemented system is demonstrated by analog-digital signal processing tests, and is verified by comparing the test results with those of existing similar systems.

An Implementation of Spirometry System Based Differential Pressure Method (차동 압력 방식을 이용한 호흡측정 시스템 구현)

  • 김요한;신창민;김영길
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.440-447
    • /
    • 2002
  • This paper considerated about exact flow volume calculation method from factors having an influence on measurement and introduced in anesthesia ventilator realized spirometry system. System used differential pressure sensing method with factors, that is temperature, pressure, gas density, humidity and mucus etc. System optimized for low power system for mobile system. System composed analog interface part, signal processing part, display part. Analog interface part have differential pressure flow sensor and defferential pressure sensor. Signal processing part have AVR processor for low power system display part use serial port (RS232, SPT). so it display at pc monitor or send to anesthesia ventilator. System is stable by linearizing 2th characteristics of flow-differential pressure, auto correction of sensor. Noise reduced by algorithm with analog filter and digital processing. Small, light, low power system is good at mobile system and applied to patient in emergency or mobile. and, System is useful at anesthesia ventilator by using flow sensor.

  • PDF

A study on the characteristics of cyanobacteria in the mainstream of Nakdong river using decision trees (의사결정나무를 이용한 낙동강 본류 구간의 남조류 발생특성 연구)

  • Jung, Woo Suk;Jo, Bu Geon;Kim, Young Do;Kim, Sung Eun
    • Journal of Wetlands Research
    • /
    • v.21 no.4
    • /
    • pp.312-320
    • /
    • 2019
  • The occurrence of cyanobacteria causes problems such as oxygen depletion and increase of organic matter in the water body due to mass prosperity and death. Each year, Algae bloom warning System is issued due to the effects of summer heat and drought. It is necessary to quantitatively characterize the occurrence of cyanobacteria for proactive green algae management in the main Nakdong river. In this study, we analyzed the major influencing factors on cyanobacteria bloom using visualization and correlation analysis. A decision tree, a machine learning method, was used to quantitatively analyze the conditions of cyanobacteria according to the influence factors. In all the weirs, meteorological factors, temperature and SPI drought index, were significantly correlated with cyanobacterial cell number. Increasing the number of days of heat wave and drought block the mixing of water in the water body and the stratification phenomenon to promote the development of cyanobacteria. In the long term, it is necessary to proactively manage cyanobacteria considering the meteorological impacts.

A Indoor Management System using Raspberry Pi (라즈베리 파이를 이용한 실내관리 시스템)

  • Jeong, Soo;Lee, Jong Jin;Jung, Won Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.745-752
    • /
    • 2016
  • In the era of the Internet of Things, where all physical objects are connected to the Internet, we suggest a remote control system using a Raspberry Pi single-board computer with ZigBee, which can turn an indoor light-emitting diode (LED) and a multiple-tap on and off, and with a smart phone can control the brightness of the LED as well as an electronic door lock. By connecting an infrared (IR) transmitter module to the Raspberry Pi, we can control home appliances, such as an air conditioner, and we can also monitor indoor images, indoor temperatures, and illumination by using a smart phone app. We developed a method of finding out IR transmission codes required for remote-controllable appliances with an AVR micro-controller. We suggest a method to remotely open and shut an office door by novating the door lock. The brightness level of an LED (between 0 and 10) can be controlled through a PWM signal generated by an ATmega88 microcontroller. A mutiple-tap is controlled using an ATmega32, a photo-coupler, and a TRIAC. The signals for measured temperature and illumination are converted from analog to digital by using the ATtiny44A microcontroller transmitting to a Raspberry Pi through SPI communication. Then, we connect a camera to the CSI head of the Raspberry Pi. We can turn on the smart multiple-tap for a certain period of time, or we can schedule the multi-tap to turn on at a specific time. To reduce standby power, people usually pull out a power code from multiple-taps or turn off a switch. Our method helps people do the same thing with a smart phone, if they are away from home.

Design and Fabrication of Low Power Sensor Network Platform for Ubiquitous Health Care

  • Lee, Young-Dong;Jeong, Do-Un;Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1826-1829
    • /
    • 2005
  • Recent advancement in wireless communications and electronics has enabled the development of low power sensor network. Wireless sensor network are often used in remote monitoring control applications, health care, security and environmental monitoring. Wireless sensor networks are an emerging technology consisting of small, low-power, and low-cost devices that integrate limited computation, sensing, and radio communication capabilities. Sensor network platform for health care has been designed, fabricated and tested. This system consists of an embedded micro-controller, Radio Frequency (RF) transceiver, power management, I/O expansion, and serial communication (RS-232). The hardware platform uses Atmel ATmega128L 8-bit ultra low power RISC processor with 128KB flash memory as the program memory and 4KB SRAM as the data memory. The radio transceiver (Chipcon CC1000) operates in the ISM band at 433MHz or 916MHz with a maximum data rate of 76.8kbps. Also, the indoor radio range is approximately 20-30m. When many sensors have to communicate with the controller, standard communication interfaces such as Serial Peripheral Interface (SPI) or Integrated Circuit ($I^{2}C$) allow sharing a single communication bus. With its low power, the smallest and low cost design, the wireless sensor network system and wireless sensing electronics to collect health-related information of human vitality and main physiological parameters (ECG, Temperature, Perspiration, Blood Pressure and some more vitality parameters, etc.)

  • PDF

Optimal Road Maintenance Section Selection Using Mixed Integer Programming (혼합정수계획법을 활용한 도로포장 보수구간 선정 최적화 연구)

  • Cho, Geonyoung;Lim, Heejong
    • International Journal of Highway Engineering
    • /
    • v.19 no.3
    • /
    • pp.65-70
    • /
    • 2017
  • PURPOSES : Pavement Management System contains the data that describe the condition of the road. Under limited budget, the data can be utilized for efficient plans. The objective of this research is to develop a mixed integer program model that maximizes remaining durable years (or Lane-Kilometer-Years) in road maintenance planning. METHODS : An optimization model based on a mixed integer program is developed. The model selects a cluster of sectors that are adjacent to each other according to the road condition. The model also considers constraints required by the Seoul Metropolitan Facilities Management Corporation. They select two lanes at most not to block the traffic and limit the number of sectors for one-time construction to finish the work in given time. We incorporate variable cost constraints. As the model selects more sectors, the unit cost of the construction becomes smaller. The optimal choice of the number of sectors is implemented using piecewise linear constraints. RESULTS : Data (SPI) collected from Pavement Management System managed by Seoul Metropolitan City are fed into the model. Based on the data and the model, the optimal maintenance plans are established. Some of the optimal plans cannot be generated directly in existing heuristic approach or by human intuition. CONCLUSIONS:The mathematical model using actual data generates the optimal maintenance plans.

Sorption Characteristics of Binary Mixture of Corn Starch- Soy Protein Isolates in Plastic film Packaging (Plastic필름 포장에 따른 옥수수 전분과 분리 대두단백질의 이성분 혼합물의 흡습특성)

  • Kim, Duck-Woong;Woo, Sang-Gyu
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.17 no.3
    • /
    • pp.191-197
    • /
    • 1988
  • Sorption properties of corn starch(CS) and Soy protein isolates(SPI) in plastic films packaging were investigates for binary system. The mixture were sealed in plastic films of low density polyethylene(LDPE), oriented polypropylene(OPP) and LDPE/OPP coated film and packaging effect on the changes of moisture sorption during storage at $40^{\circ}C$ were studied. The following results were obtained. The water vapor permeability of material films was $32.6g/m^2/24hrs(below\;g)$ for 0.02mm LDPE film, 14.01g for 0.04mm LDPE film, 7.30g for 0.02mm OPP film, 3.37g for 0.04mm OPP film and 4.869 for 0.02mm LDPE/0.02 mm OPP confine film at $40^{\cire}C$ 90%RH, therefore the OPP film was more effective than LDPE film on the resistance of relative humidity. And the OPP film packaging sealed mixture of food samples was also more elective then LDPE film, having same thickness for increase of water vapor permeability during storage at $40^{\cire}C$. A general increase in sorption rate was found more in SPI than CS in the packaged mixtures.

  • PDF