• Title/Summary/Keyword: SOIL EROSION

Search Result 803, Processing Time 0.02 seconds

Effect of Temperature and Various Pre-treatments on Germination of Hippophae rhamnoides Seeds (갈매보리수나무 종자의 온도 및 여러 가지 전처리에 따른 발아반응)

  • Choi, Chung-Ho
    • Korean Journal of Plant Resources
    • /
    • v.25 no.1
    • /
    • pp.132-141
    • /
    • 2012
  • This study was carried out to test seed germination responses to temperatures and pre-treatments in Hippophae rhamnoides, which has many abilities in antioxidant activity, soil improvement and erosion control. H. rhamnoides seeds were placed at 10, 15, 20, 25, 30 and $35^{\circ}C$ under light condition. As the results, germination percentage (GP) was the highest at 15 and $20^{\circ}C$, and mean germination time (MGT), germination rate (GR) and germination value (GV) were the highest at $25^{\circ}C$. Quadratic and linear regression model were used to determine the cardinal temperatures such as base ($T_b$), maximum ($T_m$) and optimum ($T_o$) temperature for germination. In quadratic regression model using PG, $T_b$, $T_m$ and $T_o$ was estimated as 0.6, 36.4 and $18.5^{\circ}C$, respectively, and temperature range for germination was $35.8^{\circ}C$. In linear regression model using GR, $T_b$, $T_m$ and $T_o$ was estimated as 8.3, 35.4 and $25.3^{\circ}C$, respectively, and temperature range for germination was $27.2^{\circ}C$. Germination properties were investigated after H. rhamnoides seeds were treated by prechilling (1, 2, 4, 6 and 8 weeks), stratification (2, 4, 6 and 8 weeks), solid matrix priming (seed : carrier : water = 5 : 1 : 7, 8, 9 and 10), osmo-priming (-0.25, -0.5, -1.0 and -1.5 MPa) and calcium chloride ($CaCl_2$) -priming (100, 200, 300 and 400 mM). The highest GP was observed in $CaCl_2$ 300 and 400 mM treatments, and MGT was the shortest in stratification 6 and 8 weeks treatments. GR and GV were the highest and GP was the second highest when seeds were prechilled for 1 and 2 weeks. Consequently, prechilling 1 or 2 weeks treatment was considered as the appropriate method when we contemplate qualitative and quantitative effects in seedling production.

A Study On Irrigation Water Price Structure and Prescription (농업용수의 가격구조에 관한 연구)

  • 심기영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.15 no.4
    • /
    • pp.3170-3180
    • /
    • 1973
  • This study of the subject will review past and present irrigation development in Korea. Particular attention will be given to water pricing structure and a case study on the purpose of rational operation and management of irrigation water and organizations, and the optimum irrigation water and organizations, and the optimum irrigation water fee inorder to reduce farmers burden and to rationalize the farmland associations management so as to achieve development of the rural environment. In 1971, the reservoir of the Farmland Improvement A sociation (FIA) produced only 775 millison $m^3$ of irrigation water or 77% of planned capacity of 1,015 million $m^3$. It was caused by inefficient maintenance of irrigation facilities; for instance, about 21% of reservoirs, pumping stations and weirs in Korea have been silted by soil erosion which hinder to water production according to an ADC survey. The first Irritation Association was established in 1906, whcih was renamed the Farmland Assoeiation by the Rural Development Enouragement Law in 1970. By the end of 1971, 411,000 ha of rice paddies were under the control of 267 associations nationwide. The average water price assessed by Associations nationwide rose from 790 won per 0.1 ha. in 1966 to 1,886 won in 1971. The annual growth rate was 20%. The highest water price in 1971 was 4,773 won her 0.1 ha. and the lowest was 437 won. This range was caused by differences in debt burden, geographic conditions and management efficiency among the Associations. In 1971, the number of Associations which exceeded the average water price of 1,886 won per 0.1 ha. was 144, or 55.1% of all Association. In determination of water price, there are two principles; one is determined by production cost such as installation cost of irrigation facilities, maintenance cost, management cost and depreciation ect. For instance, the Yong San River Development project was required 33.7 billion won for total construction and maintenance cost is 3.1 billion won for repayment, maintenance and management cost per year. The project produces 590 million $m^3$ of irrigation water annually. Accordingly, the water price per $m^3$ is 5.25 won. The other principle is determined by water value in the crop products and in compared with production of irrigated paddy and non-irrigated paddy. By using this method, water value in compared with paddy rice vs. upland rice(Average of 1967-1971) was 14.15 won per $m^3$ and irrigated paddy vs. non-irrigated paddy was 2.98 won per $m^3$. In contrast the irrigation fee in average association of 1967-1971 was 1.54 won per $m^3$. Accordingly, the current national average irrigation fee(water price) is resonable compared with its water value. In this study, it is found that the ceiling of water price in terms of water value is 2.98 won per $m^3$ or 2,530 won per 0.1 ha. However, in 1971 55% of the associations were above the average of nationwide irrigation fees. which shows the need for rationalization of the Association's management. In connection with rationalization of the Association's management, this study recommends the following matters. (1) Irrigation fee must be assessed according to the amount of water consumption taking intoaccount the farmer's ability. (2) Irrigation fee should be graded according to behefits and crop patterns. (3) Training personnel in the operation and procedures of water management to save O&M costs. (4) Insolvent farmland association should be integrated into larger, sound associations in the same GUN in order to reduce farmers' water cost. (5) The maintenance and repair of existing irrigation facilities is as important as expansion of facilities. (6) Establishment of a new Union of Farmland Association is required to promoted proper maintenance and to protect the huge investment in irrigation facilities by means of technical supervision and guidance.

  • PDF

A Change of Stream Water Quality by Forest Types (임상에 따른 계류수의 수질변화에 관한 연구)

  • Ma, Ho-Seop;Kang, Won-Seok;Kang, Eun-Min
    • Journal of Korean Society of Forest Science
    • /
    • v.100 no.2
    • /
    • pp.142-148
    • /
    • 2011
  • This study was carried out to clarify the change characteristics of stream water quality by type of forest from June to August, 2009 in three stands (Castanea crenata, Pinus densiflora and Plantation Land) of Samgye-ri Naedong-myeon Jinju-si Gyeongsangnam-do. The pH of stream water in three stands was highest in Pinus densiflora (pH 7.18) followed by Castanea crenata (pH 6.90) and Plantation land (pH 6.90) while the electrical conductivity of stream water was highest in Plantation land followed by Castanea crenata stand and Pinus densiflora stand was the lowest. Cations contents of stream water in three stands were high in order of $Ca^{2+}$, $Na^{+}$, $Mg^{2+}$, $K^{+}$, and $NH_{4}{^{+}}$. But anions of stream water in Castanea crenata stand and Pinus densiflora stand were high in order of $SO_{4}{^{2-}}$, $Cl^{-}$ and $NO_{3}{^{-}}$ while those of stream water in Plantation land were high in order of $SO_{4}{^{2-}}$, $NO_{3}{^{-}}$ and $C\lambda^{-}$. The stream water in three stands was significant at pH, EC, $NO{^{3-}}$, $Ca^{2+}$, $Mg^{2+}$, $Na^{+}$, $Cl^{-}$, TNU and Color by duncan test. These results indicate that quality of stream water have a difference among three stands. The level of pH, $NH_{4}{^{+}}$, $Cl^{-}$, $SO_{4}{^{2-}}$ and $NO_{3}{^{-}}$ of stream water in three stands were within the domestic use standard for drinking water. but turbidity and color of stream water were more than that of domestic use standard for drinking water. Therefore, non-point sources like urban forest watersheds which are soil erosion and fertilizer application lands should be taken to the appropriate mitigation measures if they are to be used as source of drinking water.