• Title/Summary/Keyword: SNR(Signal to noise ratio)

Search Result 1,135, Processing Time 0.029 seconds

A Study Radiograph Techniques for Diagnosis of Axillary Fracture Ribs in X-ray (X-ray 갈비뼈 촬영에서 겨드랑이쪽의 골절된 갈비뼈 진단을 위한 촬영법 연구)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.979-986
    • /
    • 2019
  • The purpose of this study devised a method for the examination of the images of the first and second rib fractures of the axillary using Rib Rando Phantom. The position of the phantom and the angle of the X-ray tube were changed to vertical, head 5° and foot 5°. The Radiological Technologists subjectively evaluated the acquired images and the evaluation data were analyzed by SPSS 3.0 ver. The signal to noise ratio(SNR) was calculated using the ImageJ Program. As a result, the cronbach alpha value was significantly higher at 0.789. The SNR was highest at 6.038 when the X-ray tube was tilted 5° toward the head in the front of the ribs and highest at 7.860 when the X-ray tube was tilted 5° toward the foot. Radiographic Techniques proposed axillary ribs this study are as follows. The anterior rib scan is examined by elevating the fractured area and changing the X-ray tube angle by 5° towards the head. The posterior ribs scan is examined by attaching the fractured area and changing to the X-ray tube angle by 5° towards the foot. It is considered that such an inspection method can obtain a sharp image.

Performance Improvement of the Combined AMC-MIMO Systems with Independent MCS Level Selection Method (독립적인 MCS 레벨 선택 방식이 적용된 AMC-MIMO 결합 시스템의 성능 개선)

  • Hwang, In-Tae;Choi, Kwang-Wook;Ryoo, Sang-Jin;Lee, Kyung-Hwan;You, Cheol-Woo;Hong, Dae-Ki;Kang, Min-Goo;Kim, Cheol-Sung
    • Journal of Internet Computing and Services
    • /
    • v.8 no.1
    • /
    • pp.47-55
    • /
    • 2007
  • In this paper, we propose and observe a system that adopts Common-MCS (Modulation and Coding Scheme) level over all layer and Independent-MCS level for each layer in the combined AMC-V-BLAST (Adaptive Modulation and Coding-Vertical-Bell-lab Layered Space-Time) system. Also, comparing with the combined system using Common-MCS level, we observe throughput performance improvement in case of Independent-MCS level. As a result of simulation, Independent-MCS level case adapts modulation and coding scheme for maximum throughput to each channel condition in separate layer, resulting in improved throughput compared to Common-MCS level case. Especially, the results show that the combined AMC-V-BLAST system with Independent-MCS level achieves a gain of 700kbps in $7{\sim}9dB$ SNR (Signal-to-Noise Ratio) range against using Common-MCS level. In addition, the combined AMC-V-BLAST system using MMSEnulling method with receive diversity is verified that the difference of throughput between Independent MCS level system and common MCS level system in $7dB{\sim}9dB$ SNR is about 350kbps more or less.

  • PDF

Cooperative Communication Scheme Based on channel Characteristic for Underwater Sensor Networks (수중 센서 네트워크를 위한 채널 특성기반의 협력 통신 기법)

  • Ji, Yong-Joo;Choi, Hak-Hui;Lee, Hye-Min;Kim, Dong-Seong
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.6
    • /
    • pp.21-28
    • /
    • 2016
  • This paper presents a cooperative transmission scheme for underwater acoustic sensor networks to improve packet transmission rate and reduce energy consumption. Source node transmits duplicated information relayed by distributed antennas called a virtual antenna array. Destination node combines that information to reduce packet error rate. The suggested cooperative scheme enhances the reliability by providing high diversity gains through intermediate relay nodes to overcome the distinct characteristics of the underwater channel, such as high transmission loss, propagation delay, and ambient noises. It is suggested that the algorithm select destinations and potential relays from a set of neighboring nodes that utilize distance cost, the residual energy of each node and local measurement of the channel conditions into calculation. Simulation results show that the proposed scheme reduces average energy consumption, response time, and increases packet delivery ratio compared with the SPF(Shortest Path First) and non-cooperative scheme using OPNET Moduler.

A Study on Techniques for Focusing Circumferential Array Guided Waves for Long Range Inspection of Pipes (배관 원거리 진단을 위한 원주방향 배열 유도초음파 집속기술 개발)

  • Kang, To;Kim, Hak-Joon;Song, Sung-Jin;Cho, Young-Do;Lee, Dong-Hoon;Cho, Hyun-Joon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.114-121
    • /
    • 2009
  • Ultrasonic guided waves have been widely utilized for long range inspection of structures. Especially, development of array guided waves techniques and its application for long range gas pipe lines(length of from hundreds meters to few km) were getting increased. In this study, focusing algorithm for array guided waves was developed in order to improve long range inspectability and accuracy of the array guided waves techniques for long range inspection of gas pipes, and performance of the developed techniques was verified by experiments using the developed array guided wave system. As a result, S/N ratio of array guided wave signals obtained with the focusing algorithm was increased higher than that of signals without focusing algorithm.

Quantitative Assessment and Ligament Traceability of Volume Isotropic Turbo Spin Echo Acquisition (VISTA) Ankle Magnetic Resonance Imaging: Fat Suppression versus without Fat Suppression (발목관절 VISTA 자기공명영상에서 정량평가와 인대의 Traceability: 지방억제 대비 지방억제기법)

  • Cho, Kyung Eun;Yoon, Choon-Sik;Song, Ho-Taek;Lee, Young Han;Lim, Daekeon;Suh, Jin-Suck;Kim, Sungjun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.110-122
    • /
    • 2013
  • Purpose : To compare the image quality and ligament traceability in ankle images obtained using Volume Isotropic Turbo Spin Echo Acquisition (VISTA) MRI with and without fat suppression. Materials and Methods: The signal-to-noise ratios (SNRs) in images from a phantom and from the ankle of a volunteer were compared. Ten ankles from 10 non-symptomatic volunteers were imaged for comparisons of contrast ratio (CR) and ligament traceability. All examinations were performed using VISTA sequences with and without fat suppression on a 3T MRI scanner. The SNRs were obtained from images with subjects and without subjects (noise-only). Contrast ratios from images of the 10 ankles were acquired between fluid and tendon (F-T), F-cartilage (C), F-ligament (L), fat (f)-T, f-C and f-L. Two musculoskeletal radiologists independently scored the traceability of 7 ligaments, in sagittal, axial and coronal images respectively, based on a 4-point scale (1 as not traceable through 4 as clearly traceable). The Wilcoxon signed-rank test was used to compare the CR. Fisher's exact test and Pearson's chi-squared test were used to compare the ligament traceability. Results: The SNRs did not differ significantly between the two sequences except in bone marrow. VISTA SPAIR showed the higher CR only in F-T (p = 0.04), whereas VISTA showed higher CR in f-T (p = 0.005), f-C (p = 0.005) and f-L (p = 0.005). The calcaneofibular ligament traceability with VISTA was superior to that obtained with VISTA SPAIR (p < 0.05) in all planes. Conclusion: VISTA showed significant superiority to VISTA SPAIR in tracing CFL due to the superior CR between fat and ligament.

Multi-Level Correlation LMS Algorithm for Digital On-Channel Repeater System in Digital TV Broadcasting System Environment (DTV 방송 시스템 환경에서 동일 채널 중계기를 위한 다중 레벨 상관 LMS 기법)

  • Lee, Je-Kyoung;Kim, Jeong-Gon
    • Journal of Broadcast Engineering
    • /
    • v.15 no.1
    • /
    • pp.63-75
    • /
    • 2010
  • In this paper, the equalizer techniques that is able to adopt the digital on-channel repeater for 8VSB-based DTV system has been analyzed and we propose an effective equalizer structure which can reduce the error propagation phenomenon by the feedback signal and improve the receiver performance at the same time. In order to confirm the effective cancellation of the feedback signal, the multi-level Correlation LMS scheme is proposed through the analysis of conventional basic LMS based DFE and Correlation LMS algorithm and as compared with the conventional method, we can confirm the reduction of error propagation. When performing the computer simulation, as the Brazil channel model which is very popular for DTV broadcasting system is adopted, the result is drawn by comparing and analysing the equalizer algorithm. We have examine the symbol error rate which is in the range of 15~25dB of operation receipt SNR and MSE(Mean Square Error) in the DTV broadcasting system. As a result of comparing with the existing method, the signal-noise ratio which is necessary for maintain the bit error correction ability that the means of proposal is same is reduced by about 2~5dB, and in the rate of convergence through the MSE, we found the reduction of needed time.

Performance of Detection Probability with Adaptive Threshold Algorithm for CR Based on Ad-Hoc Network (인지 무선 기반 애드 혹 네트워크에서 적응적 임계치 알고리즘을 이용한 센싱 성능)

  • Lee, Kyung-Sun;Kim, Yoon-Hyun;Kim, Jin-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.632-639
    • /
    • 2012
  • Ad-hoc networks can be used various environment, which it is difficult to construct infrastructures, such as shadowing areas, disaster areas, war area, and so on. In order to support to considerable and various wireless services, more spectrum resources are needed. However, efficient utilization of the frequency resource is difficult because of spectrum scarcity and the conventional frequency regulation. Ad-hoc networks employing cognitive radio(CR) system that guarantee high spectrum utilization provide effective way to increase the network capacity. In conventional CR based ad-hoc network, it uses constant threshold value to detect primary user signal, so the results become not reliable. In this paper, to solve this problem, we apply adaptive threshold value to the CR based ad-hoc network, and adaptive threshold is immediately changed by SNR(Signal to Noise Ratio). From the simulation results, we confirmed that proposed algorithm has the greatly better detection probabilities than conventional CR based ad-hoc network.

Improvement of the Adaptive Modulation System with Optimal Turbo Coded V-BLAST Technique using STD Scheme (선택적 전송 다이버시티 기법을 적용한 최적의 터보 부호화된 V-BLAST 적응변조 시스템의 성능 개선)

  • Ryoo, Sang-Jin;Choi, Kwang-Wook;Lee, Kyung-Hwan;You, Cheol- Woo;Hong, Dae-Ki;Hwang, In-Tae;Kim, Cheol-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.2
    • /
    • pp.6-14
    • /
    • 2007
  • In this paper, we propose and observe the Adaptive Modulation system with optimal Turbo Coded V-BLAST (Vertical-Bell-lab Layered Space-Time) technique that is applied the extrinsic information from MAP (Maximum A Posteriori) Decoder in decoding Algorithm of V-BLAST: ordering and slicing. The extrinsic information is used by a priori probability and the system decoding process is composed of the Main Iteration and the Sub Iteration. And comparing the proposed system with the Adaptive Modulation system using conventional Turbo Coded V-BLAST technique that is simply combined V-BLAST with Turbo Coding scheme, we observe how much throughput performance has been improved. In addition, we observe the proposed system using STD (Selection Transmit Diversity) scheme. As a result of simulation, Comparing with the conventional Turbo Coded V-BLAST technique with the Adaptive Modulation systems, the optimal Turbo Coded V-BLAST technique with the Adaptive Modulation systems has better throughput gain that is about 350 Kbps in 11 dB SNR range. Especially, comparing with the conventional Turbo Coded V-BLAST technique using 2 transmit and 2 receive antennas, the proposed system with STD (Selection Transmit Diversity) scheme show that the improvement of maximum throughput is about 1.77 Mbps in the same SNR range.

Baseline Correction in Computed Radiography Images with 1D Morphological Filter (CR 영상에서 기저선 보정을 위한 1차원 모폴로지컬 필터의 이용에 관한 연구)

  • Kim, Yong-Gwon;Ryu, Yeunchul
    • Journal of radiological science and technology
    • /
    • v.45 no.5
    • /
    • pp.397-405
    • /
    • 2022
  • Computed radiography (CR) systems, which convert an analog signal recorded on a cassette into a digital image, combine the characteristics of analog and digital imaging systems. Compared to digital radiography (DR) systems, CR systems have presented difficulties in evaluating system performance because of their lower detective quantum efficiency, their lower signal-to-noise ratio (SNR), and lower modulation transfer function (MTF). During the step of energy-storing and reading out, a baseline offset occurs in the edge area and makes low-frequency overestimation. The low-frequency offset component in the line spread function (LSF) critically affects the MTF and other image-analysis or qualification processes. In this study, we developed the method of baseline correction using mathematical morphology to determine the LSF and MTF of CR systems accurately. We presented a baseline correction that used a morphological filter to effectively remove the low-frequency offset from the LSF. We also tried an MTF evaluation of the CR system to demonstrate the effectiveness of the baseline correction. The MTF with a 3-pixel structuring element (SE) fluctuated since it overestimated the low-frequency component. This overestimation led the algorithm to over-compensate in the low-frequency region so that high-frequency components appeared relatively strong. The MTFs with between 11- and 15-pixel SEs showed little variation. Compared to spatial or frequency filtering that eliminated baseline effects in the edge spread function, our algorithm performed better at precisely locating the edge position and the averaged LSF was narrower.

Calibration of ShadowCam

  • David Carl Humm;Mallory Janet Kinczyk;Scott Michael Brylow;Robert Vernon Wagner;Emerson Jacob Speyerer;Nicholas Michael Estes;Prasun Mahanti;Aaron Kyle Boyd;Mark Southwick Robinson
    • Journal of Astronomy and Space Sciences
    • /
    • v.40 no.4
    • /
    • pp.173-197
    • /
    • 2023
  • ShadowCam is a high-sensitivity, high-resolution imager provided by NASA for the Danuri (KPLO) lunar mission. ShadowCam calibration shows that it is well suited for its purpose, to image permanently shadowed regions (PSRs) that occur near the lunar poles. It is 205 times as sensitive as the Lunar Reconnaissance Orbiter Camera (LROC) Narrow Angle Camera (NAC). The signal to noise ratio (SNR) is greater than 100 over a large part of the dynamic range, and the top of the dynamic range is high enough to accommodate most brighter PSR pixels. The optical performance is good enough to take full advantage of the 1.7 meter/pixel image scale, and calibrated images have uniform response. We describe some instrument artifacts that are amenable to future corrections, making it possible to improve performance further. Stray light control is very challenging for this mission. In many cases, ShadowCam can image shadowed areas with directly illuminated terrain in or near the field of view (FOV). We include thorough qualitative descriptions of circumstances under which lunar brightness levels far higher than the top of the dynamic range cause detector or stray light artifacts and the size and extent of the artifact signal under those circumstances.