• 제목/요약/키워드: SMC Materials

검색결과 60건 처리시간 0.025초

중질 탄산칼슘의 입자 크기와 첨가량 변화에 따라 제조된 수지 조성물의 강도 및 열변형온도 (Strength and Heat Deflection Temperature of Resin Compounds Prepared Using Different Size and Content of Ground Calcium Carbonate)

  • 이윤주;허석;김영희;김수룡;권우택
    • 한국재료학회지
    • /
    • 제26권7호
    • /
    • pp.359-362
    • /
    • 2016
  • Mineral filler is used for resin compounds, because it increases the stiffness and thermal stability of a resin compound, and it also cuts down the cost. Calcium carbonate, silica, magnesium oxide, and others are used as filler materials in general, and the type of filler material, the size, and content can affect the physical properties of compounds. Those factors also influence the viscosity of resin mixtures and the workability, and should be adjusted by changing the contents of the filler, which depends on the size. In this study, five kinds of ground calcium carbonate, which were different in size, were used to produce polyester compounds ; the physical properties were compared with the filler size and contents. The mechanical properties were measured by bending strength and tensile strength, and the heat deflection temperature was obtained for thermal stability.

Valorization of swine manure into low cost activated carbons capable of Cr(VI) removal

  • Gonsalvesh, Lenia;Gryglewicz, Grazyna;Carleer, Robert;Yperman, Jan
    • Advances in environmental research
    • /
    • 제6권2호
    • /
    • pp.95-111
    • /
    • 2017
  • The valorization of swine manure samples, i.e., de-watered cake (SMc) and solid digestate (SMd), in products with beneficial value, i.e., low cost activated carbons (ACs), is studied. For this purpose slow pyrolysis and steam activation at three different duration times are applied. Additionally, the obtained ACs are characterized and tested towards removal of Cr(VI) from aqueous solutions. It is revealed that BET surface area varies in the range of $236-267m^2/g$ for ACs prepared from SMc sample and in the range of $411-432m^2/g$ for ACs prepared from SMd sample. Despite the low determined surface area of prepared ACs, a high total Cr removal capacity is observed occurring through a "coupled adsorption-reduction" mechanism. Higher Cr(VI) removal capacity is demonstrated for ACs having higher surface area ($q_m$ is 140.9 mg/g according Langmuir modelling). Cr(VI) removal is found to be pH dependent with a maximum at pH 1. However at that pH significant amounts of Cr remain in the solution as Cr(III). At pH 2 lower amount of Cr(VI) is removed compensated by a higher removal of Cr(III) resulting in a higher amount of adsorbed $Cr_{tot}$. Therefore adsorption at pH 2 is found to be appropriate. The removal capacity of the studied ACs towards Cr(VI) is almost independent of activation time.

Psychological effects and risk perception after genetic counseling

  • Shin, Sunghwan;Ryu, Mi Ra;Kwon, Won Kyung;Kim, Suhee;Jang, Ja-Hyun;Kim, Jong-Won
    • Journal of Genetic Medicine
    • /
    • 제18권1호
    • /
    • pp.38-43
    • /
    • 2021
  • Purpose: Demand for genetic counseling on cancer predisposition syndrome is increasing. We evaluated the psychological effect on counselees after genetic counseling at a clinic in a single center. Materials and Methods: We surveyed a total of 72 enrolled participants who visited a genetic counseling clinic at the Samsung Medical Center (SMC). The initial survey was conducted before the first genetic counseling session, and the second survey was conducted after the second genetic counseling session. A total of 43 participants completed both the initial and second surveys. Results: The initial survey of 72 participants indicated higher feelings of guilt in the group with religion, higher depression and anxiety in the group with a diagnosis of self, and higher anxiety in the group on self-referral to the genetic counseling clinic. In the completed survey of 43 participants, overall decreased depression was observed after the second genetic counseling session (P=0.013). Risk perception and anxiety decreased in the group diagnosed with benign variant/variant of uncertain significance (BV/VUS, 25/3) and increased in the group diagnosed with pathogenic variant (PV, 15). Risk perception and anxiety differed between the BV/VUS and PV groups (P<0.001 and P=0.03, respectively). Conclusion: The genetic counseling clinic at the SMC was effective in ameliorating the depression score. Assessment of survey results revealed different depression scores, feelings of guilt and anxiety, and different effects of the genetic counseling clinic, depending on the subgroups. Understanding the needs and psychological characteristics of different groups is necessary for improving genetic counseling services.

불포화 폴리에스터 (UPR)에 폴리우레탄을 첨가하여 강인성을 부여한 유리섬유 복합소재 (Glass Fiber Composite Material with Polyurethane Toughener in Unsaturated Polyester Resin (UPR))

  • 백창완;장태우;김태희;김혜진;김창윤;김현국;서봉국;임충선
    • 접착 및 계면
    • /
    • 제22권2호
    • /
    • pp.63-68
    • /
    • 2021
  • Unsaturated Polyester Resin (UPR)은 유리섬유와 같은 강화제와 함께 사용되어 복합재료로 사용된다. 열경화성 수지인 UPR은 복합재료의 다양한 성형법 중 생산성이 우수하고 대량생산에 유리한 sheet molding compound (SMC) 성형법으로 산업에서 사용되고 있다. UPR을 기지재로 하는 섬유강화복합재료는 가볍고, 물성이 뛰어난 장점이 있지만 충격에 약하여 깨지기 쉽고, 경화 이후에는 부피가 감소하는 단점이 있기 때문에 강인성과 유연성을 부여할 수 있는 폴리올과 캡핑제를 달리하는 폴리우레탄 4종을 합성하여 첨가하여 그 단점을 극복하고자 하였다.

통계적 기법을 이용한 선삭가공 절삭조건에 따른 공구온도 예측 (A Study on the Tool Temperature Estimation for Different Cutting Conditions in Turning Using a Statistical Method)

  • 송길용;문홍현;박병규;김성청;이응석
    • 한국정밀공학회지
    • /
    • 제19권11호
    • /
    • pp.96-102
    • /
    • 2002
  • This study is on the estimation method of toot temperature for different tool nose radius and cutting conditions in turning. Experimental analysis has been performed in different cutting conditions such as cutting speed, feed rate, and depth of cut for the tool nose radius, 0.4R, 0.8R using SMC workpiece materials. Tool temperature is measured using a thermo-couple which is embedded in the insert tip. Using multiple linear regression method, the tool temperature can be determined as an exponential equation with cutting variables and tool nose diameters for the different tool materials. The equations determined in this study show a good correlation for the cutting conditions and can be used for a tool temperature estimation technique. The result indicates that the tool temperature decreases for increasing the tool nose radius in general. Also, nose radius hardly influences on the tool temperature compared with cutting speed, feed rate and depth of cut. This method will be useful for the estimation of tool life and temperature using limited experimental data for given cutting conditions.

폐 FRP/불포화 폴리에스테르 수지 복합재의 기계적 물성에 미치는 실란계 커플링제 (3-methylacryloxyvinyl silane) 영향 (Effect of Coupling Agent(3-methylacryloxyviny1silane) on the Mechanical Properties of wasfeaste FRP/Unsaturated Polyester Composites)

  • 황택성;최돈묵;최장락;임정훈;박정기
    • 한국재료학회지
    • /
    • 제8권1호
    • /
    • pp.13-18
    • /
    • 1998
  • SMC(Sheet molding compound)욕조 생산시 발생하는 폐 FRP를 보강재로서 재활용하기 위하여 불포화 폴리에스테르 매트릭스 수지에 보강하고 보강재와 매트릭스 수지의 계면 결합력을 증진시키기 위하여 보강재를 실란계 커플링제[3-methylacryloxyviny1 silane (MAOS)]로 전 처리하여 복합재를 제조하고 기계적 물성 및 계면현사에 대하여 관찰하였다. 보강률이 20wt%인 복합재의 굴곡강도 및 굴곡탄성률이 각 각 110MPa, 8.0GPa로 가장 우수하였으며 커플링제(MAOS)의 노동가 0.50wt%인 복합재의 굴곡강도 및 굴곡탄성률은 약 10%정도 향상되어 각 각 120MPa, 9.2GPa을 나타내었다. 또한 주사전자현미경 관찰 결과 보강재를 커플링제(MAOS)로 처리한 복합재의 보강재와 매트릭스 수지는 물리, 화학적을 잘 결합하여 보강재와 매트릭스 수지의 계면에서 pull out현상이 확인되지 않았으며 크랙도 발생하지 않았다.

  • PDF

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo;Han, Youngyih;Kim, Jinsung;Ahn, Sung Hwan;Ju, Sang Gyu;Jung, Sang Hoon;Chung, Yoonsun;Cho, Sungkoo;Jo, Kwanghyun;Shin, Eun Hyuk;Hong, Chae-Seon;Shin, Jung Suk;Park, Seyjoon;Kim, Dae-Hyun;Kim, Hye Young;Lee, Boram;Shibagaki, Gantaro;Nonaka, Hideki;Sasai, Kenzo;Koyabu, Yukio;Choi, Changhoon;Huh, Seung Jae;Ahn, Yong Chan;Pyo, Hong Ryull;Lim, Do Hoon;Park, Hee Chul;Park, Won;Oh, Dong Ryul;Noh, Jae Myung;Yu, Jeong Il;Song, Sanghyuk;Lee, Ji Eun;Lee, Bomi;Choi, Doo Ho
    • Radiation Oncology Journal
    • /
    • 제33권4호
    • /
    • pp.337-343
    • /
    • 2015
  • Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

아동의 삶의 질에 대한 개념 분석 (A Concept Analysis of the Quality of Life for the Children)

  • 장은영;오진아
    • 부모자녀건강학회지
    • /
    • 제11권2호
    • /
    • pp.127-137
    • /
    • 2008
  • Purpose: The purpose of this study was to attempt an accurate understanding of the quality of life for the children and provide basic materials for application to nursing research, intervention and further theoretical development. Method: Data obtained from such research methods as the lexical and literature review were analysed according to Walker and Avant's(1995) process of concept analysis. Results: As a result of analysis, it was found that the attributes of the concept of the quality of life for the children included value/acceptance, family relationship, safety, good relationship with friends, right of children, school life, parent relationship, leisure, economical stability, not child abuse, and health. There was the coexistence between antecedent element and the outcomes of subjective judgement - health, family, economic strength, education, friends, welfare, social-cultural environment which indicates the coexistence of positive and negative emotions. Conclusion: nursing intervention should be provided for children by concentrating focus on the coordination of internal and external situations in order to prompt them to express their life with positive emotions. Experiential reference was used to suit the purpose of this study based on the use of objective and subjective indicators, and the development of the instrument considering the children were proposed because of the absence of the unified measurement instrument.

  • PDF

Fabrication and Evaluation of Polyelectrolyte Complexes of Dextran Derivatives for Drug Coating of Coronary Stents

  • Jang, Eun-Jae;Lee, So-Youn;Bae, In-Ho;Park, Dae Sung;Jeong, Myung Ho;Park, Jun-Kyu
    • 공업화학
    • /
    • 제30권5호
    • /
    • pp.586-590
    • /
    • 2019
  • The aim of this study was to fabricate a dextran polyelectrolyte multi-layer on a bare metal stent (BMS) and to evaluate bio-physical properties of the layer. Diethylaminoethyl-dextran (DEAE-D) as a polycation and dextran sulfate (DS) as a polyanion were successively coated on the bare metal stent by a well-known layer-by-layer procedure. The morphology of the stent surface and its cell adhesion were studied after each coating step by scanning electron microscopy. The stent showed more blotched and slightly rougher morphology after dextran-DS coating. The contact angle of the DEAE-DS group ($39.5{\pm}0.15^{\circ}$) was significantly higher than that of the BMS group ($45.16{\pm}0.08^{\circ}$), indicating the improvement of hydrophilic. The SMC proliferation inhibition in the DEAE-DS-coated stent group ($20.9{\pm}0.04%$) was stronger than that in the control group ($21.7{\pm}0.10%$ in DS-coated group only). The DEAE-DS coating is desired for stent coating materials with biocompatibility and anti-restenosis effect.

Agreement and Reliability between Clinically Available Software Programs in Measuring Volumes and Normative Percentiles of Segmented Brain Regions

  • Huijin Song;Seun Ah Lee;Sang Won Jo;Suk-Ki Chang;Yunji Lim;Yeong Seo Yoo;Jae Ho Kim;Seung Hong Choi;Chul-Ho Sohn
    • Korean Journal of Radiology
    • /
    • 제23권10호
    • /
    • pp.959-975
    • /
    • 2022
  • Objective: To investigate the agreement and reliability of estimating the volumes and normative percentiles (N%) of segmented brain regions among NeuroQuant (NQ), DeepBrain (DB), and FreeSurfer (FS) software programs, focusing on the comparison between NQ and DB. Materials and Methods: Three-dimensional T1-weighted images of 145 participants (48 healthy participants, 50 patients with mild cognitive impairment, and 47 patients with Alzheimer's disease) from a single medical center (SMC) dataset and 130 participants from the Alzheimer's Disease Neuroimaging Initiative (ADNI) dataset were included in this retrospective study. All images were analyzed with DB, NQ, and FS software to obtain volume estimates and N% of various segmented brain regions. We used Bland-Altman analysis, repeated measures ANOVA, reproducibility coefficient, effect size, and intraclass correlation coefficient (ICC) to evaluate inter-method agreement and reliability. Results: Among the three software programs, the Bland-Altman plot showed a substantial bias, the ICC showed a broad range of reliability (0.004-0.97), and repeated-measures ANOVA revealed significant mean volume differences in all brain regions. Similarly, the volume differences of the three software programs had large effect sizes in most regions (0.73-5.51). The effect size was largest in the pallidum in both datasets and smallest in the thalamus and cerebral white matter in the SMC and ADNI datasets, respectively. N% of NQ and DB showed an unacceptably broad Bland-Altman limit of agreement in all brain regions and a very wide range of ICC values (-0.142-0.844) in most brain regions. Conclusion: NQ and DB showed significant differences in the measured volume and N%, with limited agreement and reliability for most brain regions. Therefore, users should be aware of the lack of interchangeability between these software programs when they are applied in clinical practice.