DOI QR코드

DOI QR Code

The first private-hospital based proton therapy center in Korea; status of the Proton Therapy Center at Samsung Medical Center

  • Chung, Kwangzoo (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Han, Youngyih (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Jinsung (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Ahn, Sung Hwan (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Ju, Sang Gyu (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Jung, Sang Hoon (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Chung, Yoonsun (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Cho, Sungkoo (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Jo, Kwanghyun (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Shin, Eun Hyuk (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Hong, Chae-Seon (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Shin, Jung Suk (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Seyjoon (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Dae-Hyun (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Kim, Hye Young (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Lee, Boram (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Shibagaki, Gantaro (Industrial Equipment Division, Sumitomo Heavy Industries Ltd.) ;
  • Nonaka, Hideki (Industrial Equipment Division, Sumitomo Heavy Industries Ltd.) ;
  • Sasai, Kenzo (Industrial Equipment Division, Sumitomo Heavy Industries Ltd.) ;
  • Koyabu, Yukio (Industrial Equipment Division, Sumitomo Heavy Industries Ltd.) ;
  • Choi, Changhoon (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Huh, Seung Jae (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Ahn, Yong Chan (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Pyo, Hong Ryull (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Lim, Do Hoon (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Hee Chul (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Park, Won (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Oh, Dong Ryul (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Noh, Jae Myung (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Yu, Jeong Il (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Song, Sanghyuk (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Lee, Ji Eun (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Lee, Bomi (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine) ;
  • Choi, Doo Ho (Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University School of Medicine)
  • Received : 2015.08.21
  • Accepted : 2015.12.02
  • Published : 2015.12.31

Abstract

Purpose: The purpose of this report is to describe the proton therapy system at Samsung Medical Center (SMC-PTS) including the proton beam generator, irradiation system, patient positioning system, patient position verification system, respiratory gating system, and operating and safety control system, and review the current status of the SMC-PTS. Materials and Methods: The SMC-PTS has a cyclotron (230 MeV) and two treatment rooms: one treatment room is equipped with a multi-purpose nozzle and the other treatment room is equipped with a dedicated pencil beam scanning nozzle. The proton beam generator including the cyclotron and the energy selection system can lower the energy of protons down to 70 MeV from the maximum 230 MeV. Results: The multi-purpose nozzle can deliver both wobbling proton beam and active scanning proton beam, and a multi-leaf collimator has been installed in the downstream of the nozzle. The dedicated scanning nozzle can deliver active scanning proton beam with a helium gas filled pipe minimizing unnecessary interactions with the air in the beam path. The equipment was provided by Sumitomo Heavy Industries Ltd., RayStation from RaySearch Laboratories AB is the selected treatment planning system, and data management will be handled by the MOSAIQ system from Elekta AB. Conclusion: The SMC-PTS located in Seoul, Korea, is scheduled to begin treating cancer patients in 2015.

Keywords

References

  1. Particle Therapy Co-Operative Group. Particle therapy facilities under construction [Internet]. [place unknown]: Particle Therapy Co-Operative Group; c2013 [cited 2015 July 14]. Available from: http://www.ptcog.ch/index.php/facilities-under-construction.
  2. Perl J, Shin J, Schumann J, Faddegon B, Paganetti H. TOPAS: an innovative proton Monte Carlo platform for research and clinical applications. Med Phys 2012;39:6818-37. https://doi.org/10.1118/1.4758060
  3. Agostinelli S, Allison J, Amako K, et al. Geant4: a simulation toolkit. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 2003;506:250-303.
  4. Chung K, Kim JS, Kim DH, Ahn SH, Han YY. The proton therapy nozzles at Samsung Medical Center: a Monte Carlo Simulation Study using TOPAS. J Korean Phys Soc 2015;67:170-4. https://doi.org/10.3938/jkps.67.170
  5. Kim JS, Shin JS, Kim D, et al. Feasibility study of the neutron dose for real-time image-guided proton therapy: a Monte Carlo study. J Korean Phys Soc 2015;67:142-6. https://doi.org/10.3938/jkps.67.142
  6. Paganetti H, Niemierko A, Ancukiewicz M, et al. Relative biological effectiveness (RBE) values for proton beam therapy. Int J Radiat Oncol Biol Phys 2002;53:407-21. https://doi.org/10.1016/S0360-3016(02)02754-2
  7. Wedenberg M, Toma-Dasu I. Disregarding RBE variation in treatment plan comparison may lead to bias in favor of proton plans. Med Phys 2014;41:091706. https://doi.org/10.1118/1.4892930

Cited by

  1. Clinical outcomes of tissue expanders on adjuvant radiotherapy of resected retroperitoneal sarcoma vol.95, pp.28, 2015, https://doi.org/10.1097/md.0000000000004123
  2. Radiotherapy as valid modality for hepatocellular carcinoma with portal vein tumor thrombosis vol.22, pp.30, 2016, https://doi.org/10.3748/wjg.v22.i30.6851
  3. Secondary Neutron Dose Measurement for Proton Line Scanning Therapy vol.27, pp.3, 2015, https://doi.org/10.14316/pmp.2016.27.3.162
  4. Analysis of Treatment and Delay Times by Disease Site and Delivery Technique at Samsung Medical Center - Proton Therapy Center vol.27, pp.4, 2016, https://doi.org/10.14316/pmp.2016.27.4.258
  5. Commissioning and Validation of a Dedicated Scanning Nozzle at Samsung Proton Therapy Center vol.27, pp.4, 2015, https://doi.org/10.14316/pmp.2016.27.4.267
  6. Clinical Outcomes of Salvage Chemoradiotherapy for Locally Recurrent Biliary Tract Cancer vol.103, pp.4, 2015, https://doi.org/10.5301/tj.5000666
  7. Malignant Peripheral Nerve Sheath Tumor in the Lesser Sac Masquerading as a Gastrointestinal Stromal Tumor of the Stomach: A Case Report vol.14, pp.1, 2015, https://doi.org/10.5812/iranjradiol.39609
  8. Impacts of gantry angle dependent scanning beam properties on proton PBS treatment vol.62, pp.2, 2015, https://doi.org/10.1088/1361-6560/aa5084
  9. Development of an Analytic Software Using Pencil Beam Scanning Proton Beam vol.28, pp.1, 2015, https://doi.org/10.14316/pmp.2017.28.1.22
  10. A Pilot Study of the Scanning Beam Quality Assurance Using Machine Log Files in Proton Beam Therapy vol.28, pp.3, 2015, https://doi.org/10.14316/pmp.2017.28.3.129
  11. Abstract ID: 98 Measurement of the induced neutron ambient dose equivalent during proton therapy in scanning mode vol.42, pp.suppl1, 2015, https://doi.org/10.1016/j.ejmp.2017.09.054
  12. Valproic Acid Sensitizes Hepatocellular Carcinoma Cells to Proton Therapy by Suppressing NRF2 Activation vol.7, pp.None, 2015, https://doi.org/10.1038/s41598-017-15165-3
  13. MEASUREMENT OF NEUTRON AMBIENT DOSE EQUIVALENT IN PROTON RADIOTHERAPY WITH LINE-SCANNING AND WOBBLING MODE TREATMENT SYSTEM vol.177, pp.4, 2017, https://doi.org/10.1093/rpd/ncx056
  14. Increased Efficiency of Range Verification in Routine QA for Pencil-Beam Scanning Proton Therapy vol.73, pp.7, 2018, https://doi.org/10.3938/jkps.73.983
  15. Proton range verification in inhomogeneous tissue: Treatment planning system vs. measurement vs. Monte Carlo simulation vol.13, pp.3, 2015, https://doi.org/10.1371/journal.pone.0193904
  16. Initial clinical outcomes of proton beam radiotherapy for hepatocellular carcinoma vol.36, pp.1, 2015, https://doi.org/10.3857/roj.2017.00409
  17. The Clinical Utilization of Radiation Therapy in Korea between 2011 and 2015 vol.50, pp.2, 2015, https://doi.org/10.4143/crt.2017.096
  18. The impact of pencil beam scanning techniques on the effectiveness and efficiency of rescanning moving targets vol.63, pp.14, 2018, https://doi.org/10.1088/1361-6560/aacd27
  19. Proton therapy for hepatocellular carcinoma: Current knowledges and future perspectives vol.24, pp.28, 2015, https://doi.org/10.3748/wjg.v24.i28.3090
  20. Initial Experience of Patient-Specific QA for Wobbling and Line-Scanning Proton Therapy at Samsung Medical Center vol.30, pp.1, 2015, https://doi.org/10.14316/pmp.2019.30.1.14
  21. Development of an Assemblable, Daily, Quality-Assurance Device for Line-Scanning Proton Therapy vol.75, pp.4, 2015, https://doi.org/10.3938/jkps.75.344
  22. Early clinical outcomes of helical tomotherapy/intensity‐modulated proton therapy combination in nasopharynx cancer vol.110, pp.9, 2019, https://doi.org/10.1111/cas.14115
  23. Cyclin D1 is Associated with Radiosensitivity of Triple-Negative Breast Cancer Cells to Proton Beam Irradiation vol.20, pp.19, 2019, https://doi.org/10.3390/ijms20194943
  24. Feasibility study of a plastic scintillating plate‐based treatment beam fluence monitoring system for use in pencil beam scanning proton therapy vol.47, pp.2, 2015, https://doi.org/10.1002/mp.13922
  25. Development of a Daily-Treatment Beam-Monitoring System Based Gafchromic EBT3 Film for Pencil-Beam Scanning Proton Therapy vol.76, pp.8, 2015, https://doi.org/10.3938/jkps.76.769
  26. Comparison of clinical outcomes between passive scattering versus pencil-beam scanning proton beam therapy for hepatocellular carcinoma vol.146, pp.None, 2015, https://doi.org/10.1016/j.radonc.2020.02.019
  27. Early Clinical Outcomes of Intensity Modulated Radiation Therapy/Intensity Modulated Proton Therapy Combination in Comparison with Intensity Modulated Radiation Therapy Alone in Oropharynx Cancer Pati vol.13, pp.7, 2015, https://doi.org/10.3390/cancers13071549
  28. An alternative proposal for the regulatory framework of the large accelerator facilities in the Korean Nuclear Safety Act vol.41, pp.3, 2021, https://doi.org/10.1088/1361-6498/ac0497
  29. Current role of proton beam therapy in patients with hepatocellular carcinoma vol.10, pp.4, 2015, https://doi.org/10.18528/ijgii210043