• 제목/요약/키워드: SM.040

검색결과 6건 처리시간 0.017초

기계구조용 탄소강(SM45C)의 단속절삭 시 절삭력예측을 위한 회귀방정식 도출 (Regression Equation Deduction for Cutting Force Prediction during Interrupted Cutting of Carbon Steel for Machine Structure (SM45C))

  • 배명일;이이선
    • 한국기계가공학회지
    • /
    • 제15권4호
    • /
    • pp.40-45
    • /
    • 2016
  • Interrupted cutting has different cutting characteristics compared with continuous cutting. In interrupted cutting, the workpiece has a groove that regularly impacts the cutting tool and workpiece. Therefore, tool damage occurs rapidly, and this increases the cutting force and surface roughness. In this study, we performed interrupted cutting of carbon steel for machine structure (SM45C) using a coated carbide tool (TT7100). To predict the cutting force, we analyzed the experimental results with a regression analysis. The results were as follows: We confirmed that the factors affecting the principal force and radial force were cutting speed, depth of cut, and feed rate. From the multi-regression analysis, we deduced regression equations, and their coefficients of determination were 89.6, 89.27, and 28.27 for the principal, radial, and feed forces, respectively. This means that the regression equations were significant for the principal and radial forces but not for the feed force.

쌍곡면 측정 null 렌즈 설계 (Design of null lenses for testing of hyperbolic surfaces)

  • 김연수;김병윤;이윤우
    • 한국광학회지
    • /
    • 제12권5호
    • /
    • pp.352-355
    • /
    • 2001
  • 고해상도 원격관측용 카메라로 설계된 비축 3반사 광학계의 제1거울인 쌍곡면 형상 측정을 위한 null 렌즈를 설계하였다. Null 렌즈는 autostigmatic 방식과 mixed 방식으로 설계하였으며, 렌즈의 곡률반경, 두께등의 변수에 대한 상대적 민감도를 비교 분석하여 보다 측정이 용이한 null 렌즈를 제시하였다.

  • PDF

경증의 아토피 환자에서 한약 추출물 함유 외용제에 대한 임상 연구 (A Clinical Study for the Effect of External Applications Containing Herbal Extracts on Mild Atopic Dermatitis Patients)

  • 강민서;김정범;김희택
    • 한방안이비인후피부과학회지
    • /
    • 제27권3호
    • /
    • pp.40-55
    • /
    • 2014
  • Objectives : The purpose of this study is to confirm the effects of external applications(CLANCHE SM A Clinic) containing herbal extracts on patient with atopic dermatitis. Methods : A total of 24 patients who visited Semyung Oriental Medical Center from January 15th, 2014 to February 20th, 2014 were included in the study. In this study, the patients were treated with external applications(CLANCHE SM A Clinic) containing herbal extracts. For 4 weeks of gross examination and instrumental assesment were made before and after the study. Results : 1. In the primary endpoint, SCORAD index showed a statistically significant decline. 2. In the secondary endpoint, index of skin hydration and index of TEWL showed statistical significance. 3. In the secondary endpoint, index of skin pH showed no statistically significant result. 4. To evaluate the safety of the products for the human body, vital sign check were conducted and showed no statistically significant result. And There were no severe adverse events during this study. Therefore, it is suggested that the safety of the products, if used for certain period, should be safe for the human body. 5. In global assesment of efficacy, both experimenter and subjects evaluated external applications were effective. Conclusions : According to the above experiments, it is suggested that external applications(CLANCHE SM A Clinic) containing herbal extracts should be effective for the atopic dermatitis.

매개하향변환 과정에서 발생하는 광자쌍의 상관관계에 따른 동시계수 측정 (Effects of the decorrelation on the coincidence detection with correlated photons in a parametric down-conversion)

  • 김헌오;고정훈;김태수
    • 한국광학회지
    • /
    • 제12권6호
    • /
    • pp.431-436
    • /
    • 2001
  • 자발적인 매개하향변환과정에서 발생하는 광자쌍을 이용하여, 광학계내의 광손실에 따른 상관관계의 감소가 단일광자계수 와 두-광자 동시계수에 미치는 영향을 조사하였다. 두 검출기 앞에 얇은 유리판을 설치하고 유리판의 편광에 따른 투과율을 변화시켜 두 광자들간의 상관관계를 인위적으로 조절하였다. 상관관계의 정도에 따라 측정된 단일광자계수는 광자를 측정하는 검출기 앞에 놓인 유리판의 투과율에 비례하는 반면에, 두-광자 동시계수는 두 검출기 안에 놓인 두 유리판의 투과율의 곱에 비례하였다.

  • PDF

분광복사휘도 측정용 광검출기의 특성 평가 (Characteristics of Photodetectors for spectral radiance measurements)

  • 서정철;박승남;김봉학
    • 한국광학회지
    • /
    • 제12권5호
    • /
    • pp.376-381
    • /
    • 2001
  • 광원의 분광복사휘도를 측정하기 위한 실험 장치를 구성하였으며, PMT, Si, InGaAs a c IR enhanced InGaAs 광검출기의 특성을 평가하였다. 구성된 분광복사휘도 측정 장치의 파장 영역은 250~2500nm이며, 1.0 $\mu$A 이하의 신호에서 비선형 감응도가 0.1% 이하로 선형성이 우수하므로 분광복사휘도의 국가 표준 장치로 사용될 수 있음을 알 숭 있었다.

  • PDF

연속발진 불화중수소 화학 레이저 출력특성 (Output characteristics of a continuous wave deuterium fluoride chemical laser)

  • 이정환;박병서;김재기
    • 한국광학회지
    • /
    • 제13권1호
    • /
    • pp.65-69
    • /
    • 2002
  • 불소원자(F)와 D$_2$ 기체 발열반응에 의해 레이저 이득매질인 DF 여기분자를 생성시키는 구조의 연속발진형 불화중수소 (DF)화학 레이저를 설계, 제작하고 발진 실험을 수행하였다. 불소원자는 F$_2$ 기체와 H$_2$ 기체를 연소시켜 생성시키고, 불소원자를 초음속 노즐을 통과시킨 직후에 D$_2$ 기체를 분사하여 형성된 DF 여기분자 초음속 흐름을 활성 매질로 사용하여 레이저를 발진시켰다. 본 연구에서 얻은 레이저 발진 출력은 101W이며, 최적의 유량조건에서 얻은 화학 효율은 5.12%, 비출력은 96.5 J/g이다.