• Title/Summary/Keyword: SM 400

Search Result 89, Processing Time 0.03 seconds

An Experimental Study of Concussion Blasting for Structural Steel (구조용 강재에 대한 폭파절단실험 연구)

  • Yang, Hyung-Sik;Jang, Hyong-Doo;Ko, Young-Hun;Kim, Sung-Jun;Moon, Hee-Sook
    • Explosives and Blasting
    • /
    • v.29 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • Concussion shots were conducted for SS400, a general structural steel, and SM490, a structural steel for welding, using TNT, which is used as a standard explosive. The ability to cut the steels was compared for different combinations of charges and materials. The results show that the amount of explosives used for SM490 requires more 30% than SS400.

A study on application of high strength steel SM570 in bridge piers with stiffened box section under cyclic loading

  • Kang, Lan;Suzuki, Motoya;Ge, Hanbin
    • Steel and Composite Structures
    • /
    • v.26 no.5
    • /
    • pp.583-594
    • /
    • 2018
  • Although a lot of experimental and analytical investigations have been carried out for steel bridge piers made of SS400 and SM490, the formulas available for SS400 and SM490 are not suitable for evaluating ultimate load and deformation capacities of steel bridge piers made of high strength steel (HSS) SM570. The effect of various parameters is investigated in this paper, including plate width-to-thickness ratio, column slenderness ratio and axial compression force ratio, on the ultimate load and deformation capacities of steel bridge box piers made of SM570 steel subjected to cyclic loading. The elasto-plastic behavior of the steel bridge piers under cyclic loads is simulated through plastic large deformation finite element analysis, in which a modified two-surface model (M2SM) including cyclic hardening is employed to trace the material nonlinearity. An extensive parametric study is conducted to study the influences of structural parameters on the ultimate load and deformation capacities. Based on these analytical investigations, new formulas for predicting ultimate load and deformation capacities of steel bridge piers made of SM570 are proposed. This study extends the ultimate load and deformation capacities evaluation of steel bridge piers from SS400, SM490 steels to SM570 steel, and provides some useful suggestions.

A Study on the Properties of SM 400 for Evaluation of Structural Stability at High Temperature (고온 시의 구조내력 평가를 위한 SM 400강재의 고온 특성 평가 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.27 no.4
    • /
    • pp.7-12
    • /
    • 2013
  • Recently, the risk of fire outbreak is going up because of newly developed combustible materials are intended to apply more. Especially the steel framed structure can lose its load-bearing capacity when it is exposed to higher temperature condition such as a fire. So the pre-evaluation of fire resistance of the structure is very essential that the mechanical properties of yield strength and elastic modulus and thermal properties such as conductivity and linear expansion be required. To get the databases for SM 400 or welding structural steels at high temperature, various temperature conditions were used for deriving the yield strength, elastic modulus, linear expansion, and conductivity and the results were compared to those of SS 400, ordinary structural steel, respectively.

Fatigue of SS490A and SS400 Corroded Specimens (SM490A와 SS400 대기부식 시편의 피로 특성 평가)

  • Goo, Byeong-Choon
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.725-731
    • /
    • 2009
  • For structural design and diagnosis, quantitative relationship between corrosive degradation and variation of mechanical properties such as tensile strength and fatigue strength is needed. But it is difficult to find experimental data associated with corrosive degradation of structural structures in the literature. In this study, first of all I established the atmospheric corrosion test procedure. And using specimens of SM490A and SS400 on the atmospheric corrosion test bed, I carried out tensile and fatigue tests at regular intervals. And we studied the effect of post-weld heat treatment on the tensile and fatigue behaviour. It is found fatigue strength decreases as the atmospheric corrosion period increases.

An Experimental Study on the Atmospheric Corrosion and Fatigue of SS490A and SS400 (SM490A와 SS400의 대기부식 및 피로강도의 실험적 연구)

  • Goo, B.C.
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1787-1791
    • /
    • 2007
  • For structural design and diagnosis, quantitative relationship between corrosive degradation and variation of mechanical properties such as tensile strength and fatigue strength is needed. But it is difficult to find data associated with corrosive degradation of structural structures. In this study, first of all we established the atmospheric corrosion test procedure. And using specimens of SM490A and SS400 on the atmospheric corrosion test bed, we carried out tensile and fatigue tests at regular intervals. And we studied the effect of post-weld heat treatment on the tensile and fatigue behaviour. It is found fatigue strength decreases as the atmospheric corrosion period increases.

  • PDF

A Study on the Materials Characteristics of High Tensile Strength Steel(SM570) Plates (고장력(SM570)강재의 재료특성에 관한 연구)

  • Im, Sung Woo;Ko, Sang Ki;Ha, Dong Woo;Oh, Sang Hoon;Chang, In Hwa
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.649-659
    • /
    • 2000
  • In this study, the chemical compositions and mechanical properties of high tensile strength steel plates in accordance with their thickness are quantitatively estimated, that are steel plates SM570 to be purposed to use in building structure. Test results of steel plates SM570 are compared with those of steel plates SS400 and steel plates SM490 mostly using building structure. It is found that chemical compositions, carbon equivalent, parameter of welding crack susceptibility, yield strength, tensile strength, elongation, and impact strength have satisfied the prescribed value in KS code for all case of thickness.

  • PDF

Physical and Chemical Properties of (Sr,Mg)FeO3-y System Heat-treated in N2 (N2 분위기에서 열처리한 (Sr,Mg)FeO3-y계의 물리 및 화학적 성질)

  • Lee, Eun-Seok
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.10
    • /
    • pp.642-647
    • /
    • 2015
  • The perovskite solid solutions of the $Sr_{1-x}Mg_xFe{^{3+}}_{1-{\tau}}Fe{^{4+}}_{\tau}O_{3-y}$ system (x=0.0, 0.1, 0.2, and 0.3) were synthesized in $N_2$ at $1,150^{\circ}C$. X-ray powder diffraction study assured that all the four samples had cubic symmetries(SM-0: $3.865{\AA}$, SM-1: $3.849{\AA}$, SM-2: $3.833{\AA}$, and SM-3: $3.820{\AA}$) and that the lattice volumes decreased steadily from $57.7{\AA}^3$ to $55.7{\AA}^3$ with x values. The nonstoichiometric chemical formulas were determined by Mohr salt analysis and with the increase of x values the amounts of $Fe^{4+}$ ion and oxygen were decreased simultaneously. Thermal analysis showed that SM-0 started to lose its oxygen at $450^{\circ}C$ and SM-1, Sm-2, and SM-3 began to lose their oxygen at around $350{\sim}400^{\circ}C$. SM-0 showed almost reversible weight change in the cooling process. All the samples exhibited semiconducting behaviors in the temperature range of $10{\sim}400^{\circ}C$. Conductivities of the 4 samples were decreased in the order of SM-0, SM-1, SM-2, and SM-3 at constant temperature. The activation energies of the conductions were in the range of 0.176 eV~0.244 eV.

Improved Effort Estimation Process for Work Load Balancing in SM Project. (SM 조직의 Effort Estimation 프로세스 개선을 통한 업무 Load Balancing 방안 연구)

  • Kim, Suk-Yong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2005.11a
    • /
    • pp.397-400
    • /
    • 2005
  • SM 프로젝트는 SI 프로젝트와 달리 고객의 요청 사항(CSR)이 있을 때 마다 개발 계획을 세우고 관리를 하여야 하며 동시에 고객의 개발 요청 내용 외에도 운영업무에 대한 계획도 같이 세워 져야 한다. 하지만 대부분의 SM 프로젝트에서는 한 두 사람의 경험이나 판단으로 계획이 작성, 할당되며 운영업무에 대한 계획의 정확도도 떨어져 업무 load balancing 이 잘 되지 않는다. 본 논문에서는 이러한 문제 해결을 위해 효과적인 SM 프로젝트에서의 EFFROT ESTIMATION 프로세스를 제안하여 업무 load balancing 을 이루는 방안을 제시하고자 한다.

  • PDF

Effect of Alloy Elements on Microstructure of Modified Area via Friction Stir Process in Steel Materials (마찰교반공정을 통한 강재의 개질 영역에서의 미세조직에 미치는 합금원소의 영향)

  • Kim, Sang Hyuk;Lee, Kwang Jin;Woo, Kee Do
    • Korean Journal of Materials Research
    • /
    • v.25 no.8
    • /
    • pp.370-375
    • /
    • 2015
  • In this study, to confirm the effect of alloying elements on the phase transformation and conditions of the friction stir process, we processed two materials, SS400 and SM45C steels, by a friction stir process (FSP) under various conditions. We analyzed the mechanical properties and microstructure of the friction stir processed zone of SS400 and SM45C steels processed under 400RPM - 100mm/min conditions. We detected no macro (tunnel defect) or micro (void, micro crack) defects in the specimens. The grain refinement in the specimens occurred by dynamic recrystallization and stirring. The microstructure at the friction stir processed zone of the SS400 specimen consisted of an ${\alpha}$-phase. On the other hand, the microstructure at the friction stir processed zone of the SM45 specimen consisted of an ${\alpha}$-phase, $Fe_3C$ and martensite due to a high cooling rate and high carbon content. Furthermore, the hardness and impact absorption energy of the friction stir processed zone were higher than those of base metals. The hardness and impact absorption energy of FSPed SM45C were higher than that of FSPed SS400. Our results confirmed the effect of alloying elements on the phase transformation and mechanical properties of the friction stir processed zone.

A study on the corrosive behaviour of Rolling stock structures by electrochemical experiments (전기화학시험에 의한 구조물의 부식 특성 연구)

  • Oh Chang-Rok;Kim Yong-Ki;Jang Se-Ky;Goo Byeong-Chun
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.284-289
    • /
    • 2004
  • The present paper describes an experimental study on the corrosive behaviour of Rolling stock structures. It is important to predict corrosive behaviour of rolling stock structures for safe service and to know relation between corrosion and fatigue life. This paper practiced electrochemical corrosion test of SS400 and SM490A. This study will examine the corrosive properties and differences of SS400 and SM490A from measuring corrosion potential and corrosion current density.

  • PDF