• Title/Summary/Keyword: SLIPA

Search Result 2, Processing Time 0.014 seconds

Comparison of Three Supraglottic Airway Devices in Neutral and Cervical Neck Collar Position (융복합적 기술이 적용된 성문위기구들의 삽관용이성 비교)

  • Tak, Yang-Ju
    • Journal of Digital Convergence
    • /
    • v.14 no.12
    • /
    • pp.369-375
    • /
    • 2016
  • Purpose of this study was to compare the easiness of insertion of three Supraglottic airway devices(SADs) in a neutral and cervical neck collar position in a manikin setting. Three different SADs-Laryngeal Mask Classic (LMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. Thirty nine emergency medical technicians (EMTs) who are working in Korea 119 rescue services were taught briefly about the use of the LMA, I-gel and SLIPA in a manikin setting. The time to effective ventilation was shorter in I-gel ($10.5{\pm}2.2$, $11.4{\pm}5.7$) and SLIPA ($12.3 {\pm}5.1$, $12.0{\pm}6.8$) than LMA ($17.2{\pm}3.2$, $18.5{\pm}5.5$) in a neutral and cervical neck collar position, respectively(p<0.05). There was no difference between head positions in each of the airways. In conclusion, in the speed of insertion, I-gel and SLIPA were superior to LMA in the neutral and cervical collar setting of a manikin.

Comparative assessment of the easiness and speed of insertion of three supraglottic airway devices - A manikin study - (3가지 성문위기도기(Supraglottic airway device)의 삽관 용이성과 삽관시간 비교 - 마네킨을 이용한 연구-)

  • Kim, Sang-Tae;Kang, Bo-Ra;Tak, Yang-Ju
    • The Korean Journal of Emergency Medical Services
    • /
    • v.16 no.2
    • /
    • pp.23-30
    • /
    • 2012
  • Purpose : This study was designed to compare the easiness and speed of insertion of three supraglottic airway devices(SADs) in a manikin setting. Methods : Three different SADs - Laryngeal Mask Classic(cLMA), I-gel and Streamlined Liner of the Pharynx Airway(SLIPA) were applied. One hundred and nineteen paramedical students with(group H) or without (group L) previous airway experience were taught brief manikin training about the use of the cLMA, I-gel and SLIPA. The students inserted each device in a randomized order. Time to effective ventilation was recorded in seconds from holding the device to the first chest inflation. Success was determined as adequate chest wall movement. Results : The insertion attempts were lesser in I-gel($1.00{\pm}0.00$) and SLIPA($1.05{\pm}0.27$) than cLMA($1.16{\pm}0.41$, p<.05). The shortest time to insertion was recorded for I-gel($10.5{\pm}3.0sec$), followed by the SLIPA($12.9{\pm}4.5sec$) and cLMA($19.6{\pm}4.1sec$, p<.05). There were no significant differences in the insertion attempts and insertion time of I-gel between group L and group H. But in cLMA, longer insertion time and more insertion attempts were recorded in group L than group H. Conclusion : Both I-gel and SLIPA were superior to cLMA in the easiness and speed of insertion. Even in novice students, I-gel showed an excellent result in a manikin.