• 제목/요약/키워드: SLA surface.

검색결과 103건 처리시간 0.022초

Comparison of removal torques between laser-treated and SLA-treated implant surfaces in rabbit tibiae

  • Kang, Nam-Seok;Li, Lin-Jie;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.302-308
    • /
    • 2014
  • PURPOSE. The purpose of this study was to compare removal torques and surface topography between laser treated and sandblasted, large-grit, acid-etched (SLA) treated implants. MATERIALS AND METHODS. Laser-treated implants (experimental group) and SLA-treated implants (control group) 8 mm in length and 3.4 mm in diameter were inserted into both sides of the tibiae of 12 rabbits. Surface analysis was accomplished using a field emission scanning electron microscope (FE-SEM; Hitachi S-4800; Japan) under ${\times}25$, ${\times}150$ and ${\times}1,000$ magnification. Surface components were analyzed using energy dispersive spectroscopy (EDS). Rabbits were sacrificed after a 6-week healing period. The removal torque was measured using the MGT-12 digital torque meter (Mark-10 Co., Copiague, NY, USA). RESULTS. In the experimental group, the surface analysis showed uniform porous structures under ${\times}25$, ${\times}150$ and ${\times}1,000$ magnification. Pore sizes in the experimental group were 20-40 mm and consisted of numerous small pores, whereas pore sizes in the control group were 0.5-2.0 mm. EDS analysis showed no significant difference between the two groups. The mean removal torque in the laser-treated and the SLA-treated implant groups were 79.4 Ncm (SD = 20.4; range 34.6-104.3 Ncm) and 52.7 Ncm (SD = 17.2; range 18.7-73.8 Ncm), respectively. The removal torque in the laser-treated surface implant group was significantly higher than that in the control group (P=.004). CONCLUSION. In this study, removal torque values were significantly higher for laser-treated surface implants than for SLA-treated surface implants.

EFFECT OF TITANIUM SURFACE ROUGHNESS ON CELL ADHESION OF HUMAN OSTEOBLAST-LIKE CELLS (MG63)

  • Yim Soon-Ho
    • 대한치과보철학회지
    • /
    • 제42권3호
    • /
    • pp.261-266
    • /
    • 2004
  • Statement of problem. The effects of surface roughness have not or insufficiently been analyzed on earlier events such as cell adhesion though cell behavior most germane to implant performance is cell adhesion. Purpose. The purpose of this study was to evaluate cell adhesion of osteoblast-like cells (MG63) onto three types of titanium disks with varying roughness using the Elisa assay. Materials and methods. Representative disks from each group (SLA, HA, machined) were subjected to surface analysis and surface roughness was measured by the optical interferometer (Accura 2000, Intekplus Co., Seoul, Korea). Following this, MG63 cells were cultured on the titanium disks and released. Cell adhesion measurements using the Elisa assay were performed specifically at three points: after 24, 48, and 72 hours of culture. Results. Among the 3 types of surface analyzed, the SLA surface was the roughest with a Ra value of $1.114{\mu}m$ followed by HA coated surface and machined surface, consecutively. The optical density values for the SLA surface group was significantly higher than that of the machined and HA coated surface groups following 24 and 48 hours of culture. The cell culture on HA coated surface showed significantly higher values compared to the machined surface following 24, 48 and 72 hours of culture. Conclusion. The results suggest that surface treatment of titanium surfaces enhanced cell adhesion of human osteoblast-like cells (MG63).

임플랜트 표면 처리 방법에 따른 골조직 반응에 대한 연구 (ON THE BONE TISSUE REACTION TO IMPLANTS WITH DIFFERENT SURFACE TREATMENT METHODS)

  • 김용재;조인호
    • 대한치과보철학회지
    • /
    • 제45권1호
    • /
    • pp.71-84
    • /
    • 2007
  • Statement of problem: Implant surface characteristics plays an important role in clinical success and many studies have been made for improvement of success by changing surface roughness. Purpose: Appropriate increase of surface roughness increases the activity of osteoblast and enhance contact and retention between bone and implant. Material and method- Machined, SLA and RBM surface implants, which are the most commonly used implants were implanted into the tibia of rabbits and after 1 week, 4 weeks, 8 weeks and 12 weeks there were histologic and histomorphometric analysis and study for bone gradient and change of Ca/P ratio using EDS(Energy Dispersive X-ray Spectroscope). Results: Comparison of bone-implant contact showed no significant difference among each implant. In comparison of bone area rates, SLA showed higher value with significant difference at 1 week and 4 weeks, and SLA and RBM at 8 weeks than Machined implant (p<0.05). In analysis of bone constituents with EDS, titanium was specifically detected in new bones and the rates were constant by surface treatment method or period. In case of Ca/P ratio, according to surface treatment method, each group showed significant difference. Lots of old bone fragments produced during implantation remained on the rough surface of RBM implant surface and each group showed histological finding with active synthesis of collagen fibers until 12 weeks. In transmission electronic microscopic examination of sample slice after elapse of twelve weeks, tens nm of borderline (lamina limitans like dense line)was seen to contact the bone, on the interface between bone and implant. Conclusion: SLA and RBM implant with rough surface shows better histomorphometrical result and the trend of prolonged bone formation and maturation in comparison with Machined implant. In addition, implant with rough surface seems to be helpful in early stage bone formation due to remaining of old bone fragments produced in implantation. From the results above, it is considered to be better to use implant with rough surface in implantation.

Determination of Process Parameters in Stereo lithography Using Neural Network

  • Lee, Eun-Dok;Sim, Jae-Hyung;Kweon, Hyeog-Jun;Paik, In-Hwan
    • Journal of Mechanical Science and Technology
    • /
    • 제18권3호
    • /
    • pp.443-452
    • /
    • 2004
  • For stereo lithography process, accuracy of prototypes is related to laser power, scan speed, scan width, scan pattern, layer thickness, resin characteristics and etc. An accurate prototype is obtained by using appropriate process parameters. In order to determine these parameters, the stereolithography (SLA) machine using neural network was developed and efficiency of the developed SLA machine was compared with that of the traditional SLA. Optimum values for scan speed, hatching spacing and layer thickness improved the surface roughness and build time for the developed SLA.

SLA 3D 프린팅 소재의 후처리에 따른 표면특성 변화 연구 (A Study on the Changes in Surface Properties According to Post-treatment of SLA 3D Printing Materials)

  • 배서준;임도진
    • Korean Chemical Engineering Research
    • /
    • 제60권1호
    • /
    • pp.132-138
    • /
    • 2022
  • 본 연구에서는 광경화 3D 프린팅 방식인 SLA (Stereo Lithography Apparatus) 방식 출력물의 후처리 방법에 따른 표면 특성의 변화를 체계적으로 비교하고, 용도에 맞는 후처리 방법에 대한 정보를 제공하기 위한 기초 연구를 수행하였다. SLA 방식 출력물은 연마를 통해 표면의 불규칙한 미세구조를 규칙적으로 변화시켜 투명도를 일부 개선할 수는 있었으나, 유리와 같은 충분한 투명도를 확보하기는 어려웠다. 연마에 따른 접촉각 특성 변화는 연마 시간이 증가할 수록 그리고 사용된 사포의 입도가 작을 수록 다소 증가하는 경향을 보였으나 샘플 간 편차가 크고 평균 77~90°의 접촉각을 나타내어 대부분 통계적으로 유의미한 차이를 보이지는 않았다. 연마 이외 다양한 방법을 통한 표면처리 방법이 시도되었으며, 시판되는 차량용 흠집제거제나 실리콘 오일 등을 도포하여 쉽고 간단하게 투명도를 개선하는 것이 가능함을 확인하였다. 또한, 입도 사이즈를 줄이며 순차적으로 연마한 후 흠집제거제를 사용함으로써 유리와 같은 높은 투명도를 확보할 수 있는 방법을 제안하였다. 마지막으로 연마와 다양한 방법을 통해 표면처리를 하더라도 접촉각은 90° 이상을 확보하기 어려웠으며 소수성의 특성을 필요로 하는 경우, 본 연구에서 사용된 다양한 방법 외 소수성 코팅과 같은 추가적인 처리가 필요함을 확인하였다.

Comparison of removal torques between laser-etched and modified sandblasted acid-etched Ti implant surfaces in rabbit tibias

  • Park, Kyung-Soon;Al Awamleh, Abdel Ghani Ibrahim;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권1호
    • /
    • pp.73-78
    • /
    • 2018
  • PURPOSE. The purpose of this study was to analyze the effects of two different implant surface treatments on initial bone connection by comparing the Removal Torque Values (RTQs) at 7 and 10 days after chemically modified, sandblasted, large-grit and acid-etched (modSLA), and Laser-etched (LE) Ti implant placements. MATERIALS AND METHODS. Twenty modSLA and 20 LE implants were installed on the left and right tibias of 20 adult rabbits. RTQs were measured after 7 and 10 days in 10 rabbits each. Scanning electron microscope (SEM) photographs of the two implants were observed by using Quanta FEG 650 from the FEI company (Hillsboro, OR, USA). Analyses of surface elements and components were conducted using energy dispersive spectroscopy (EDS, Horiba, Kyoto, Japan). RESULTS. The mean RTQs were $12.29{\pm}0.830$ and $12.19{\pm}0.713$ Ncm after 7 days (P=.928) and $16.47{\pm}1.324$ and $16.17{\pm}1.165$ Ncm after 10 days (P=.867) for LE and modSLA, respectively, indicating no significant inter-group differences. Pore sizes in the LE were $40{\mu}m$ and consisted of numerous small pores, whereas pore sizes in the modSLA were $5{\mu}m$. In the EDS analysis, Ti, O, and C were the only three elements found in the LE surfaces. Na, Ca, Cl, and K were also observed in modSLA, in addition to Ti, O, and C. CONCLUSION. The implants showed no significant difference in biomechanical bond strength to bone in early-stage osseointegration. LE implant can be considered an excellent surface treatment method in addition to the modSLA implant and can be applied to the early loading of the prosthesis clinically.

CLIMATIC TRENDS OF SOME PARAMETERS OF THE SOUTHERN OCEAN DERIVED FROM REMOTE SENSING DATA

  • Lebedev, S.A.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume II
    • /
    • pp.1023-1026
    • /
    • 2006
  • As it was shown recently, climate changes in Antarctica resulted in interannual trends of some climatic parameters like sea level pressure, surface air temperature, ice thickness and others. These tendencies have effect on the Southern Ocean meteorological and hydrological regime. The following remote sensing data: AVHRR MCSST data, satellite altimetry data (merged data of mission ERS-2, TOPEX/Poseidon, Jason-1, ENVISAT, GFO-1) are used to analyse the interannual and/or climatic tendency of sea surface temperature (SST) and sea level anomaly (SLA). According to the obtained results, SST has negative trend $-0.02{\pm}0.003^{\circ}C/yr$ for 24-yr record (1982-2005) and SLA has positive trend $0.01{\pm}0.005$ cm/yr for 24-yr record (1982-2005) and $0.24{\pm}0.026$ cm/yr for 12-yr record (1993-2005). However in some areas (for example, Pacific-Antarctic Ridge) SST and SLA tendencies are stronger $-0.065{\pm}0.007^{\circ}C/yr$ and $-0.21{\pm}0.05$ cm/yr, respectively.

  • PDF

표면처리 시간에 따른 임플란트 미세구조의 변화;SLA와 TB 표면 임플란트 (Microstructural Change of Implant Surface conditioned with Tetracycline-HCI;SLA and TB surface implant)

  • 우정아;허익;권영혁;박준봉;정종혁
    • Journal of Periodontal and Implant Science
    • /
    • 제35권4호
    • /
    • pp.921-937
    • /
    • 2005
  • Mechanical and chemical methods are the two ways to treat the implant surfaces. By using mechanical method, it is difficult to eliminate bacteria and by-products from the rough implant surface and it can also cause the structural change to the implant surface. Therefore, chemical method is widely used in order to preserve and detoxicate the implant surface more effectively. The purpose of this study is to evaluate the effect of tetracylcline- HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used in this study. Implant surface was rubbed with sponge soaked in 50mg/ml tetracycline - HCl solution for $\frac{1}{2}$ min., 1min., $1\frac{1}{2}$ min., 2 min., and $2\frac{1}{2}min.$ respectively in the test group and with no treatment in the control group. The sponge was soaked in every 30 seconds. Then, the specimens were processed for scanning electron microscopic observation. Based upon the analysis of photographs by three dentists who are not related with this study, the results were obtained as follows; 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. Subsequently, the acid-etching process created the micro roughness, which thus was superimposed on the macro roughness. Irrespective of the application time of 50mg/ml tetracycline - HCl solution, in general, test specimens were similar to control. 3. In the $TiO_2blasted$ surfaces, the control specimen showed the rough surface With small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline - HCl solution was lessened and the flattened areas got wider after 1 minute.

염산테트라싸이클린의 적용시간에 따른 임플란트 표면변화에 관한 주사전자현미경적 연구 (Scanning Electron Microscopic Study of the Effect of Tetracycline-HCl on the Change of Implant Surface Microstructure according to Application Time)

  • 김우영;이만섭;박준봉;허익
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.523-537
    • /
    • 2002
  • The present study was performed to evaluate the effect of tetracycline - HCl on the change of implant surface microstructure according to application time. Implants with pure titanium machined surface, SLA surface and $TiO_2blasted$ surface were used. Implant surface was rubbed with 5Omg/ml tetracycline - HCl solution for ${\frac}{1}{2}$ min., 1 min., $1{\frac}{1}{2}$ min., 2 min., and 3min. respectively in the test group and with no conditioning in the control group. Then, the specimens were processed for scanning electron microscopic observation. The following results were obtained. 1. In the pure titanium machined surfaces, the control specimen showed a more or less rough machined surface composed of alternating positive and negative lines corresponding to grooves and ridges. After treatment, machining line was more pronounced for the control specimens. but in general, test specimens were similar to control. 2. In the SLA surfaces, the control specimen showed that the macro roughness was achieved by large-grit sandblasting. subsequently, the acid-etching process crated the micro roughness, which thus was superimposed on the macro roughness. 3. In the SLA surfaces, irrespective of the application time of 50mg/ml tetracycline-HCl solution, in general, test specimens were similar to control. 4. In the $TiO_2blasted$ surfaces the control specimen showed the rough surface with small pits. The irregularity of the $TiO_2blasted$ surfaces with 50mg/ml tetracycline-HCl solution was lessened and the flattened areas were wider relative to the application time of tetracycline - HCl solution. In conclusion, pure titanium machined surfaces and SLA surfaces weren't changed irrespective of the application time of tetracycline-HCl solution. And the $TiO_2blasted$ surfaces conditioned with tetracycline - HCl solution began to be changed from $1{\frac}{1}{2}$ min. This results are expected to be applied to the regenerative procedures for peri-implantitis treatment.

SLA surface를 가진 taper straight designed implant의 방사선학적 평가와 생존율: 1년 추적 관찰을 통한 후향적 연구 (Radiologic evaluation and survival rate of taper-straight designed implant with SLA surface: A 1-year follow-up retrospective study)

  • 김지은;김예슬;김옥수
    • 대한치과보철학회지
    • /
    • 제59권4호
    • /
    • pp.405-414
    • /
    • 2021
  • 목적: 이번 연구는 최근 시판되고 있는 국내산 taper straight 타입의 SLA surface를 가진 임플란트의 변연골 흡수도와 생존율을 평가하여 임상적 유용성을 알아보기 위해 시행하였다. 대상 및 방법: 전남대학교 치과병원 치주과에서 2016년 8월부터 2019년 12월까지 KISPLANT®가 식립된 성인남녀 83명의 125개의 임플란트 중 포함 기준을 충족시키는 19명의 40개의 임플란트를 1년 동안의 관찰 대상으로 하였다. 처음과 1년 후의 치근단 방사선 사진에서 변연골 수준을 측정하고, 이를 이용하여 임플란트 생존율과 성공률을 분석하였다. 또한 치주염 심도, SPT, 식립 부위, 치아 발거 이유, 즉시 식립 여부, 전신질환에 따라 변연골 흡수도에 유의한 차이가 있는지를 확인하기 위해 t-test를 수행하였다. 결과: 근심측 변연골 흡수도는 0.74 ± 1.07 mm, 원심측 변연골 흡수도는 0.53 ± 1.04 mm로 나타났다. 1년 동안 40개의 임플란트 중 3개의 임플란트에서 2 mm 이상의 변연골 흡수가 일어나 임플란트 성공률은 92.5%이고 생존율은 100%이었다. t-test를 수행한 결과 근심측 변연골 흡수도와 식립 부위에서 유의한 차이가 있었고 나머지 요인에서는 유의한 차이가 없었다. 결론: 이번 연구에서 변연골 흡수도와 성공률, 생존율을 평가해 본 결과 임플란트 식립 1년 후 높은 생존율과 성공률을 보였고 낮은 변연골 흡수도를 보여 taper straight 타입의 SLA surface를 가진 임플란트는 우수한 임상 결과를 보였다.