• Title/Summary/Keyword: SF6 Gas

Search Result 567, Processing Time 0.027 seconds

Crystal growth studies of $SF_6$ clathrate hydrate ($SF_6$ 하이드레이트 결정의 성장 특성에 대한 연구)

  • Lee, Yoon-Seok;Lee, Ju-Dong;Lee, Bo-Ram;Lee, Hyun-Ju;Lee, Eun-Kyung;Kim, Soo-Min;Kim, Young-Seok;Yoon, Seog-Young;Kim, Yang-Do
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.19 no.5
    • /
    • pp.228-236
    • /
    • 2009
  • In this study, we investigated morphological characteristics of $SF_6$ clathrate hydrate crystals to understand its formation and growth mechanism. $SF_6$ clathrate hydrate crystals were formed in high-pressure reaction cell charged with pure water and $SF_6$ gas at constant pressure and temperature. Two-phase ($SF_6$ gas/aqueous solution) and three-phase ($SF_6$ gas/aqueous solution/$SF_6$ liquid) conditions were investigated, In both conditions, dendritic shape hydrate crystals were grown as like fibriform crystals along upward growth direction at the gas/aqueous solution interface. In the case of the reaction process of three-phase condition, when the $SF_6$ gas bubbles which were generated in $SF_6$ liquid phase due to the reduction of reaction cell pressure stuck to the gas/aqueous interfaces, the hydrate phase were appeared at the surface of the bubbles. This paper presents the detail growth characteristics of $SF_6$ hydrate crystals including crystal nucleation, migration, growth and interference.

Analysis of Cold Gas Flow in Puffer Type GCB Considering the Real Gas Property of $SF_6$ ($SF_6$ 가스의 실제 기체특성을 고려한 파퍼식 가스차단기 내의 냉가스 유동해석)

  • 김홍규;정진교;박경엽
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.129-134
    • /
    • 2004
  • To analyze the performance of the gas circuit breaker(GCB), the flow field variables such as temperature, pressure and density should be evaluated accurately In the puffer chamber of puffer type GCB, the pressure rise may Exceed 20 bar and in this range of high pressure, $SF_6$ gas deviates the ideal gas property. Therefore, the real gas property of $SF_6$ should be taken into consideration for the accurate analysis of flow field. This paper presents the analysis technique of cold gas flow in GCB employing the real gas state equation of SF6. The FVFLIC method is Employed to solve the axisymmetric Euler equation. To reduce the computational effort of real gas state equation, the relationship between density and pressure is approximated by the polynomial at the temperature of 300K. The proposed method is applied to the test GCB model and simulation results show good agreement with the experimental ones.

Installation and Test Run of Comprehensive Analysis System for SF6 in Power Equipment

  • Lee, Jeong Eun;Kim, Kwang Sin;Kim, Ah Reum;Park, Seoksoon;Kim, Kyeongsook
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.3 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • After $SF_6$, which is being used in power equipment as an insulating material, is classified as one of the 6 major greenhouse gases, the maintenance and the refinement of used $SF_6$ started to get attention. In regard to this, KEPCO Research Institute (KEPRI) is developing $SF_6$ recovery and refinement technology starting with establishing a comprehensive $SF_6$ analysis system. With the analysis system, qualitative and quantitative analyses of the purity and the impurities of $SF_6$ before and after recovery, and before and after refinement have been carried out. The analysis system is comprised of GC-DID (Gas Chromatograph -Discharge Ionization Detector) for trace impurities analysis, GC-TCD (Thermal Conductivity Detector) for analyses of $SF_6$ purity and major impurities concentration from several hundred ppm up to percent range, GC-MSD (Mass Selective Detector) for analyses of impurities not included in standard gas, FT-IR (Fourier Transform-Infrared) Spectrometer for analysis of HF and $SO_2$, and moisture analyzer for analysis of moisture below 100 ppm. With this analysis system, complete analysis method of $SF_6$ has been established. This analysis system is being used in the maintenance of power equipment and the development of $SF_6$ recovery and refinement technologies. In this paper, the analysis results of four samples - gas and liquid phase $SF_6$ samples from a $SF_6$ refinement system before and after refinement are presented.

Characteristics Analysis of Frequency Spectrum with Pressure Variation of SF6 Gas (압력 변화에 따른 SF6 가스의 주파수 스펙트럼 특성 분석)

  • Yoon, Dae-Hee;Do, Young-Hoe;Song, Hyun-Jik;Kim, Ki-Chae;Park, Won-Ju;Lee, Kwang-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.75-80
    • /
    • 2006
  • The disastrous accident happens and the economic loss comes into being at the power facilities that used a industry site, if the fault comes into being. This paper experiments the partial discharge in the GIS used a $SF_6$ insulation gas by the pressure change. We studied the influence of particles at the partial discharge in a $SF_6$ gas. We use UHF method and measure the partial discharge signal radiation electromagnetic waves and to be happened at the $SF_6$. And we analyzed the influence on the $SF_6$ gas to have the particles which the partial discharge analyzes a spectrum of the radiated electromagnetic waves and comes out. The paper results aided the prevention of breakdown accident that happened by particles when an inside pressure changes at the GIS & the power facilities used $SF_6$ gas.

A Study on A Hot Gas Velocity Measurement in GCB Using Small-Gap (Small-Gap을 이용한 가스차단기에서의 열가스 속도측정에 관한 연구)

  • Kim, Hong-Kyu;Song, Ki-Dong;Park, Kyong-Yop;Hong, Jung-Pyo;Chong, Jin-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.3
    • /
    • pp.155-158
    • /
    • 2006
  • $SF_6$ gas circuit breakers we widely used for short circuit current interruption in EHV or UHV power system. For a $SF_6$ gas circuit breaker development, the hot gas velocity measurement is necessary during $SF_6$ gas circuit breaker's trip operation. Small-gap flashover characteristics are used for this hot gas velocity measurement. This study sho was the hot gas velocity measurement results during $SF_6$ gas circuit breaker' trip operation.

Separation and Recovery of $SF_6$ Gas from $N_2/SF_6$ Gas Mixtures by using a Polymer Hollow Fiber Membranes (고분자 중공사 분리막을 이용한 $N_2/SF_6$ 혼합가스로부터 $SF_6$의 분리 및 회수)

  • Lee, Hyun-Jung;Lee, Min-Woo;Lee, Hyun-Kyung;Lee, Sang-Hyup
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • $SF_6$ (Sulfur hexafluoride) possesses high GWP (Global Warming Potential) as sepcified by the IPCC (Intergonvernmental Panel of Climate Change). Recently, the recovery-separtion of $SF_6$ research area, including permeation properties studies using various membrane's materials and the practical operation of recovery-separtion using membrane of waste $SF_6$ gas is in the initial state. The separation efficiency of a single $SF_6$ and waste $SF_6$ mixture was evaluated using a PSF (polysulfone), PC (tetra-bromo polycarbonate) and PI (polyimide) hollow fiber membranes. According to the results of single gases permeation properties, PI membrane has the highest permselectivity of $N_2$ gas in $N_2/SF_6$ gas. Under the condition of P=0.5 MPa, the highest concentration of recovered $SF_6$ is 95.6 vol % in the separation experiment of $SF_6/N_2$ mixture gas by PC membrane. Under the operation pressure of P=0.3 MPa at a fixed retentate flow rate fixed of 150 cc/min, the maximum recovery efficiency of $SF_6$ is up to 97.8% by PSF membrane. From the results above, it is thought that the separation and recovery technique of $SF_6$ gas using membrane will be used as the representative eco-technology in the $SF_6$ gas treatment in the future.

Study on The Small-Gap Measuring System for Gas Velocity Measurement of $SF_6$ Gas Circuit Breaker ($SF_6$ 가스차단기에서 가스 속도측정을 위한 Small-Gap 측정시스템에 관한 연구)

  • Kim Hong-Kyu;Dong Song-Ki;Lee Woo-Young;Park Kyong-Yop;Chong Jin-Kyo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.3
    • /
    • pp.139-144
    • /
    • 2005
  • [ $SF_6$ ] gas circuit breakers are widely used short circuit current interruption in EHV or UHV power system. For a $SF_6$ gas circuit breaker development, the $SF_6$ gas velocity measurement is necessary during $SF_6$ circuit breaker's trip operation. Small-gap flashover characteristics are used for this measurement. So, small-gap measuring system which will be used to develope GCB should be developed. This study shows the characteristic analysis and experimental results of small-gap measuring system.

AC Breakdown Voltage Characteristics of $SF_6/CF_4$ and (E/P)crit in quasi-uniform Field (준평등전계에서 $SF_6/CF_4$ 혼합가스의 절연 파괴 전압 및 임계전계 특성)

  • Lee, Byung-Taek;Hwang, Cheong-Ho;An, Jung-Sik;Huh, Chang-Su
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1455_1456
    • /
    • 2009
  • $SF_6$ is the most commonly used insulating gas in electrical systems. But In these days $SF_6$ mixtures and alternative gas has been studied because of global warming. so although many studies have been carried out about binary gas mixtures with $SF_6$, few studies were presented about breakdown characteristics of $SF_6/CF_4$ mixtures. At present study the breakdown characteristics of $SF_6/CF_4$ mixtures in quasi-uniform field was performed. This experiments were carried out under AC voltages. The rod-rod electrode was used with 5 mm gap distance. The mixture of $SF_6/CF_4$ containing 20%,50%,70% of $SF_6$ were compared with pure $SF_6$ and $CF_4$ gas and gas pressure ranged from 0.1 to 0.5 MPa. The show that the breakdown voltages of gas were linearly increased according to the pressure in quasi-uniform field. For breakdown vlotage values of $(E/P)_{crit}$ are important. Because If values of (E/P) is a little more than $(E/P)_{crit}$, electrons rapidly increase and streamer discharge gernerates. Through this experiments values of $(E/P)_{crit}$ are found to vary with the ratio of $SF_6/CF_4$ mixture according to the following relationship. $V_b=(E/P)_{crit}{\cdot}p{\cdot}d$

  • PDF

Separation of $SF_6$ from $SF_6/N_2$ Mixtures Using Polymeric Membranes (고분자 분리막을 이용하여 $SF_6/N_2$ 혼합 기체에서 $SF_6$ 분리)

  • Ko, Young-deok;Lee, Hyung-Keun;Hong, Seong-Uk
    • Membrane Journal
    • /
    • v.22 no.1
    • /
    • pp.72-76
    • /
    • 2012
  • $SF_6$ has an extremely high global worming potential (GWP). Therefore, there has been an effort to reduce the use of $SF_6$ and its emission into atmosphere. One possible solution for minimizing the use of $SF_6$ in electrical equipments is utilization of gas mixtures such as $SF_6/N_2$. The $SF_6$ concentration in the gas mixture varies from 10 to 60%. However, when the apparatus is repaired or dismantled, we have to recover $SF_6$ from the gas mixture. Since the boiling point of $SF_6$is low (${\sim}-60^{\circ}C$), the liquefaction method is difficult to apply. One possible alternative is the membrane separation technology. In this study, we investigated the $SF_6$ and $N_2$ permeation properties of 5 polymeric membranes. For example, permeability of $N_2$ in BOPP membrane at $25^{\circ}C$was 0.19 barrer, whereas that of $SF_6$ was only 0.0012 barrer, resulting in the selectivity of 158. An upper bound for $SF_6/N_2$ gas pair was suggested for the first time with n = -1.33 and k = 160 (barrer).

Atmospheric Sulfur Hexafluoride $(SF_6)$ near the Kwanak Mountain, Seoul (서울 관악산 대기 중의 $SF_6$에 관한 연구)

  • Lee, Junghyun;Kim, Kyung-Ryul
    • Atmosphere
    • /
    • v.18 no.3
    • /
    • pp.225-235
    • /
    • 2008
  • Sulfur hexafluoride ($SF_6$), man-made compound, has been paid attention as a potent greenhouse gas. After Kyoto Pototcol on Climate Change in 1997, nations established the policy aimed at minimizing release of $SF_6$ to atmosphere. We have developed and operated an automatic analytical system for monitoring atmospheric $SF_6$ using gas chromatography with electron capture detector (GC-ECD) and packed separate-column. Here, we report and discuss 4-month record of atmospheric $SF_6$ concentrations monitored at Seoul National University (SNU) pilot station near the Kwanak Mountain, Seoul. Most of observed $SF_6$ concentrations were excessively high compared with Northern Hemisphere (NH) background trend obtained from National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) monitoring stations. And the observed $SF_6$ showed extremely wide variability ranging from 4.6 pptv to $1.1{\times}10^3$ pptv, which may be affected by local sources placed nearby. Simultaneous wind data with $SF_6$ measurements show that relatively high values of $SF_6$ correspond to weak wind as well as southerly. There are many engineering installations to the south of the station. The regional value of the atmospheric $SF_6$ estimated from the data selection by wind conditions is about 6.8 pptv. This value, which is similar to concentrations of urban areas, is higher than NH background concentration.