• 제목/요약/키워드: SF6 가스

검색결과 348건 처리시간 0.022초

$SF_{6}$-Ar혼합가스에서의 압력 의존도 해석 (The analysis of dependence on the gas number density in $SF_{6}$-Ar mixtures)

  • 전병훈;하성철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.248-251
    • /
    • 2002
  • We measured the electron drift velocity, W, in 0.5% $SF_{6}$-Ar mixture over the E/N range from 30 Td to 300 Td and gas pressure range from 0.1 to 8 Torr by the double shutter drift tube with a variable drift distance. This coefficient in the mixture was calculated over the same E/N and gas pressure range by using the two-term approximation of the Boltzmann equation. And the measured and calculated values at different gas number density at each E/N was appreciable dependence in the results on the gas number density,

  • PDF

불평등 전계중에서 $SF_6$가스의 절연특성 (Dielectric Characteristics of $SF_6$ Gas in Inhomogeneous Field)

  • 이창준;이복희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1870-1872
    • /
    • 1996
  • This paper presents dielectric characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The propose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane and two needles-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was 22 mm and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

$SF_{6}$ 가스중에서의 전리성장에 관한 연구 (A study on the ionization growth in $SF_{6}$ Gas)

  • 백용현;정주영;전덕규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 전기.전자공학 학술대회 논문집
    • /
    • pp.753-755
    • /
    • 1988
  • In this paper, the effective ionization coefficients (${\alpha}-{\eta}$/Po) are measured by the steady state Townsend method in Townsend discharge domain. The effective ionization coefficients are measured in the range 75${\leqq}$E/Po${\leqq}$150(V/Torr. cm) in $SF_{6}$. The values of the effective ionization coefficients are easily and precisely determined by means of the linearization of current growth equation. The effective ionization coefficients of $SF_{6}$ were agreement with that of Bhalla and Craggs.

  • PDF

$SF_6$ 가스중 V-t절연파괴특성 (Voltage Time characteristic of electrical breakdown in $SF_6$)

  • 서길수;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1770-1772
    • /
    • 1997
  • In this paper, Voltage-time characteristics of lightning impulse and switching surge breakdown in SF6 is studied on the gap and various pressure. The characteristics is categorized into three pattern depending on the configuration of the gap and gas pressure. The properties of the voltage-time characteristics in these patterns are generalized as semi-empirical formula which will be useful in the quantitation voltage evaluation of insulation coordination and the abnormal voltage protection of SF6 insulated power equipment.

  • PDF

콘덴서 콘 방식의 345KV OF 케이블용 $SF_6$ 가스중 종단접속함의 절연 설계 (A INSULATING DESIGN OF $SF_6$ GAS SEALING END OF CONDENSER CONE TYPE USED FOR 345KV OF CABLE)

  • 김화종;이상찬;오응종;이희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1553-1555
    • /
    • 1994
  • In this paper, we describes the research in condenser cone of $SF_6$ gas sealing end for 345KV oil-filled cable. The designed of condenser cone based on the results electric field analysis by electrostatics theory ana FEM. As a results. we have been designed the condenser cone and the inner insulation part of $SF_6$ seating end, the width and length, the number of condenser, the length of stress relief slope, the total length of condenser cone.

  • PDF

배전선로용 가스절연부하개폐기의 신뢰성 향상책 (Reliability for SF6 gas load break switch of distribution system)

  • 박승재;허종철;신영준;강영식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.452-454
    • /
    • 2003
  • $SF_6$ gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, most of power companies adopted the $SF_6$ gas-type load break switch for increasing the reliability of distribution network by its superior durability against external environmental condition, in substitution for air-type and oil-type switches. But, it is important to establish the general estimation process for the testing and estimation for long-term reliability. Accordingly, this paper presents the reliability testing method for $SF_6$ gas load break switch which is based on the analysis of the failure mode and the statistics.

  • PDF

교란된 평등전계에서 고기압 $SF_{6}$ 가스의 연속절연 파괴강도에 관한 연구 (A study on the repeated breakdown field strength of compressed $SF_{6}$ in uniform field perturbed by protrusion)

  • 이동인
    • 전기의세계
    • /
    • 제29권2호
    • /
    • pp.129-132
    • /
    • 1980
  • For large gas-insulated systems, the conductor utilized possess some degree of surface roughness which locally enhances the applied field at highpressure in $SF_{6}$. In order to investigate the effect of field enhancement on the breakdown field strength, the spheric protrusion was employed which gives a quantitative analysis on field enhancement. For further investigations on the breakdown level and polarity effect in $SF_{6}$, the repeated breakdown tests were performed with d.c. voltage at pressures up to about 4 bar. The experimental results show that the breakdown level does vary noticeably due to successive voltage applications and the breakdown field strength measured for a test gap with the cathode protrusion is markedly lower than that determined from the identical anode protrusion.

  • PDF

불평등 전계중에서 SF$_6$ 가스의 전구방전현상 (Predischarge Phenomena of SF$_6$ Gas in Non-uniform Fields)

  • 이복희;전덕규;이창준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.480-483
    • /
    • 1997
  • This paper describes dielectric characteristics and discharge development mechanisms of SF$_{6}$ gas stressed by very fast transient overvoltages in inhomogeneous electric field. Predischarge phenomena of SF$_{6}$ gas in non-uniform fields are statistically investigated with positive and negative very fast trannsient overvoltages. It was confirmed that all of the predischarges of the positive and negative polarities develop in a regime of stepwise leader extension. i.e, the predischarge developments leading to breakdown against very fast transient overvoltages are similar to the non-oscillating impulse voltages.ges.

  • PDF

불평등전계중에서 VFTO에 의한 $SF_6$가스의 방전특성 (Dielectric Characteristics of $SF_6$ Gas Stressed by VFTO in inhomogeneous Field)

  • 이복희;이창준;안창환;이경옥;하성철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.282-284
    • /
    • 1996
  • This paper presents prebreakdown characteristics of $SF_6$ gas stressed by the non-oscillating and oscillating impulse voltages in inhomogeneous fields disturbed by metallic protrusion. The purpose of this investigation is to present the predischarge development and dielectric characteristics of $SF_6$ gas under VFTOs. The experiments were carried out using a needle-to-plane gap geometries in the gas pressure ranges from 0.1 to 0.5 MPa. The gap separation was22 mm, and the needle-shaped protrusions were made of stainless steel 10 mm in length and 1.0 mm in diameter. As a result, it was found that the breakdown mechanism and predischarge current are principally dependent on applied voltage waveform and polarity.

  • PDF

가공용 가스절연부하개폐기 가속수명시험 (Accelerated life test of SF_6 gas load break switch for overhead line)

  • 박승재;허종철;김맹현;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.551-553
    • /
    • 2004
  • SF_6 gas has been increasingly used as the insulating and arc-suppressing medium in switchgears which are used as the protection devices of power system. Nowadays, with these trends, SF_6 load break switches have rapidly substituted for the air or oil-type load break switches, in order to get higher reliability. And, the national standard was made for reliability assessment of SF_6 gas load break switch and testing facilities was also set in KERI(Korea Electrotechnology Research Institute ). This paper introduces the synopsis for the reliability assessment requirements specified in the standard and the assessment results.

  • PDF