• 제목/요약/키워드: SE Measurement

검색결과 949건 처리시간 0.027초

The Birefringence measurement of liquid crystal ZLI-1253

  • Cho, Chang-Ho;Jung, Gyoung-Geun;Lee, Tae-Jong;Kim, Chil-Min;Lee, Chul-Se
    • 자연과학논문집
    • /
    • 제1권
    • /
    • pp.7-14
    • /
    • 1987
  • 액정 ZLI-1253 의 복굴절 측정이 파장 및 인가전압 의존도가 He-Ne 레이저와 Ar-ion 레이저를 이용하여 비교 검토된다.

  • PDF

CAD/CAM/CAI 통합에 기초한 자유곡면의 On-Machine Measurement : I. 측정오차 모델링 (On-Machine Measurement of Sculptured Surfaces Based on CAD/CAM/CAI Integration : I. Measurement Error Modeling)

  • 조명우;이세희;서태일
    • 한국정밀공학회지
    • /
    • 제16권10호
    • /
    • pp.172-181
    • /
    • 1999
  • The objective of this research is to develop a measurement error model for sculptured surfaces in On-Machine Measurement (OMM) process based on a closed-loop configuration. The geometric error model of each axis of a vertical CNC Machining center is derived using a 4${\times}$4 homogeneous transformation matrix. The ideal locations of a touch-type probe for the scupltured surface measurement are calculated from the parametric surface representation and X-, Y- directional geometric errors of the machine. Also, the actual coordinates of the probe are calculated by considering the pre-travel variation of a probe and Z-directional geometric errors. Then, the step-by-step measurement error analysis method is suggested based on a closed-loop configuration of the machining center including workpiece and probe errors. The simulation study shows the simplicity and effectiveness of the proposed error modeling strategy.

  • PDF

Cu(In,Ga)$Se_2$ 박막의 Cu 결함 및 In, Ga 비율의 변화에 따른 구조적, 광학적, 전기적 특성 연구 (Structural, optical, and electrical properties on Cu(In,Ga)$Se_2$ thin-films with Cu-defects and In/(In+Ga) ratio)

  • 정아름;김지영;조윌렴;조현준;김대환;성시준;강진규;이동하;남다현;정현식
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.47.1-47.1
    • /
    • 2011
  • We report on a direct measurement of two-dimensional chemical and electrical distribution on the surface of photovoltaic Cu(In,Ga)$Se_2$ thin-films using a nano-scale spectroscopic and electrical characterization, respectively. The Raman measurement reveals non-uniformed surface phonon vibration which comes from different compositional distribution and defects in the nature of polycrystalline thin-films. On the other hand, potential analysis by scanning Kelvin probe force microscopy shows a higher surface potential or a small work function on grain boundaries of the thin-films than on the grain surfaces. This demonstrates the grain boundary is positively charged and local built-in potential exist on grain boundary, which improve electron-hole separation on grain boundary. Local electrical transport measurements with scanning probe microscopy on the thin-films indicates that as external bias is increases, local current is started to flow from grain boundary and saturated over 0.3 V external bias. This accounts for carrier behavior in the vicinity of grain boundary with regard to defect states. We suggest that electron-hole separation at the grain boundary as well as chemical and electrical distribution of polycrystalline Cu(In,Ga)$Se_2$ thin-films.

  • PDF

환자안전에 대한 의료서비스 소비자의 인식 조사 (Healthcare Service Consumers' Perception of Patient Safety)

  • 김정은;이남주;장선미;김영미
    • Perspectives in Nursing Science
    • /
    • 제10권2호
    • /
    • pp.133-140
    • /
    • 2013
  • Purpose: This study aimed to investigate the perspective of consumers in healthcare services regarding patient safety. Methods: The study was a descriptive study using a self-reported questionnaire. The questionnaire was based on the Senior Empowerment and Advocacy in Patient Safety (SEAPS) questionnaire, which was designed to assess patient safety health beliefs. The survey was conducted online and a convenient sample of 302 adults participated in total. The reliability of the measurement (Cronbach's ${\alpha}$) was 0.758 in attitude (ATT), 0.546 in out-come efficacy (OE), 0.757 in self-efficacy (SE), and 0.703 in behaviors (BEH). Results: The average patient safety awareness score of the healthcare service consumers was 2.72 (ATT), 2.91 (OE), 2.87 (SE), and 2.27 (BEH). Our analysis indicated that there were no differences in ATT, BEH, or SE by gender, age, or education level. However, in OE and the total score of the four subscales, there were significant differences by age and gender. Correlations were identified between BEH and SE (r=0.409, p<.01), BEH and OE (r=0.202, p<.01), ATT and SE (r=0.358, p<.01), and OE and SE (r=0.241, p<.01). Conclusion: This study measured consumer perspectives concerning patient safety. The findings demonstrate the need for developing a measurement tool to assess consumer's perception of patient safety, considering Korean healthcare system and cultural context.

  • PDF

Measurement Error Modeling for On-Machine Measurement of Sculptured Surfaces

  • Cho, Myeong-Woo;Lee, Se-Hee;Seo, Tae-Il
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제2권2호
    • /
    • pp.73-80
    • /
    • 2001
  • The objective of this research is to develop a measurement error model for sculptured surface in On-Machine Measurement(OMM) process based on a closed-loop configuration. The geometric error model of each axis of a vertical CNC machining center is derived using a 4$\times$4 homogeneous transformation matrix. The ideal locations of a touch-type probe for the sculptured surface measurement are calculated from the parametric surface representation and X-, Y- directional geometric errors of the machine. Also the actual coordinates of the probe are calculated by considering the pre-travel variation of a probe and Z-directional geometric errors. Then, the step-by-sep measurement error analysis method is suggested based on a closed-loop configuration of the machining center including workpiece and probe errors. The simulation study shows the simplicity and effectiveness of the proposed error modeling strategy.

  • PDF

$Cd_4GeSe_6$ 단결정의 deep level측정 (Measurement on the deep levels of $Cd_4GeSe_6$ single crystals)

  • 김덕태
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권6호
    • /
    • pp.504-510
    • /
    • 1994
  • In this work the crystal structure, optical absorption and photoluminescence of Cd$_{4}$GeSe$_{6}$ single srystals grown by the vertical bridgman method are investigated. From the observed results of the PICTS, we proposed on energy band model which contains deep levels between the conduction band and the valence band. The energy band model permit us to explain the mechanism of the radiative recombination for the Cd$_{4}$GeSe$_{6}$ single crystals.als.

  • PDF

카드뮴 셀레나이드 나노입자를 이용한 HF의 감지 (Detection of Hydrofluoric Acid Using Cadmium Selenide Nanoparticles)

  • 김성진
    • 통합자연과학논문집
    • /
    • 제3권2호
    • /
    • pp.112-116
    • /
    • 2010
  • Prepared CdSe nanoparticles were systems, one of the most studied and useful nanostructures. Semiconductor quantum dots (QDs) have been the subject of much interest for both fundamental reseach and technical applications in recent years, due mainly to their strong size dependent properties and excellent chemical processibility. CdSe nanocrystals were synthesized by using sol-gel process. Synthesized CdSe quantum dots were studied to evaluate the optical, electronic and structural properties using UV-absorption, and photoluminescence (PL) measurement. Prepared CdSe nanoparticles were subjected to sense hydrofluoric acid. Photoluminescence was quenched upon adding of hydrofluoric acid.

바이모달 트램의 직렬형 하이브리드 추진시스템 계측장비 개발 (Development of measurement equipment for hybrid propulsion system of bimodal tram)

  • 배창한;장세기;목재균
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.241-248
    • /
    • 2010
  • A bimodal low-floor tram can provide the punctuality of trains and the flexibility of bus together to the passengers. Its propulsion system is a series hybrid type using a set of CNG engine generator and Li-polymer battery. This paper presents a development of the measurement equipment for fine-tuning of a series hybrid propulsion system of bimodal low-floor tram. Its configuration schemes are described and certified using the measurement data of bimodal low-floor tram.

  • PDF

Auditory Model Design for Objective Audio Quality Measurement

  • Dongil Seo;Park, Se-Hyoung;Ryu, Seung-wan;Jaeho Shin
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1717-1720
    • /
    • 2002
  • Objective quality measurement schemes that in- corporate properties of the human auditory system. The basilar membrane(BM) acts as a spectrum analyzer, spatially decomposing the signal into frequency components. Each filterbank is an implementation of the ERB, gam-machirp function. This filterbank is level-dependent asymmetric compensation filters. And for the validation of the auditory model, we calculate the CPD. Quality measurement is obtained from the result.

  • PDF