• Title/Summary/Keyword: SD-WAN

Search Result 107, Processing Time 0.024 seconds

A SEMG analysis of knee joint angle during close kinetic chain exercise and open kinetic chain exercises in quadriceps muscle (단일관절운동과 복합관절운동 시 슬관절 각도에 따른 대퇴사두근의 표면 근전도 비교 분석)

  • Han Sang-Wan
    • The Journal of Korean Physical Therapy
    • /
    • v.16 no.3
    • /
    • pp.192-204
    • /
    • 2004
  • The surface electromyographic(sEMG) analyses were knee joint angle during open kinetic chain exercise (OKC) and close kinetic chain exercise (CKC) in vastus medialis (VM), vastus lateralis (VL), and rectus femoralis (RF). Ten subjects with normal , aged 20 to 30(X=27.4, SD=3.23), were randomized Statistical techniques for data analysis were applied paired t-test. The 0.05 level of significane was used as the critical level for rejection of the null hypotheses for the study. And the results were: 1) Both OKC and CKC improved the strength of quadriceps muscle as the knee joint flexion was increased. 2) In OKC, the strength of VM was improved the most at the 30 degree angle. 3) In CKC, the strength of VM was improved the most at the 30 degree angle. 4) The VM/VL ratio was the largest at the 10 and 20 degree angles in OKC and CKC. 5) The VM/VL ratio at 10, 20, and 30 degree angles was significantly different between OKC and CKC (P < 0.05). Base on the results, the OKCE is recommended for the knee joint patients, especially for the patellofemoral pain syndrome patients, during the early phase of rehabilitation. In order to improve strength of the quadriceps, muscle strength training at 30 degree angle is recommended. In order to improve VM/VL ratio, 10 and 20 degree angles are recommended during OKCE and CKCE, respectively. Future researches are warranted comparing electromyographic analysis between OKCE and CKCE in the quadriceps at a certain work lead, and muscle strength performance in the quadriceps at different positions of foot.

  • PDF

Preparation of Monodispersed Polystyrene Latex Spheres (PLS) as Artificial Dusts (인공 먼지로서 단분산 Polystyrene Latex Spheres (PLS)의 제조)

  • Kim, Ok Hee;Ryu, Dong Wan;Sung, Dong Chan;Moon, Hee
    • Applied Chemistry for Engineering
    • /
    • v.23 no.1
    • /
    • pp.59-64
    • /
    • 2012
  • Polystyrene latex spheres (PLS) were prepared as artificial dusts by the emulsion polymerization with potassium persulfate (KPS) and sodium dodecyl sulfonate (SDS) as an initiator and a stabilizer, respectively. The reaction temperature and the concentration of the initiator and stabilizer were chosen as variables to control the PLS particle size. As temperature increased, the particle size decreased considerably. Furthermore, the PLS particle size and their size distributions can be controlled minutely by adjusting the concentrations of KPS and SDS. It is confirmed that the PLS prepared in this work is monodispersed with the coefficient of variance less than 7% and are in the range of 0.1~0.5 ${\mu}m$, which are good for using as artificial dusts.

The Effect of Forward Walking and Backward Walking on Quadriceps Muscles with Treadmill Inclination: Surface Electromyographic Analysis (경사진 트레드밀에서 전방 걷기와 후방걷기 동안 넙다리네갈래근 활동성 비교: 표면 근전도 분석)

  • Han, Sang-Wan
    • Physical Therapy Korea
    • /
    • v.12 no.1
    • /
    • pp.63-70
    • /
    • 2005
  • To compare the effects of forward walking and backward walking on surface electromyographic analysis of quadriceps muscles at treadmill grades of 0%, 5% and 10%, subjects were randomized to eleven athletics (5 females, 6 males), with a mean age of 17.8 years, and a SD of 4.66 years. The values of the surface electromyographic (SEMG) activity of the rectus femoris (RF), vastus lateralis (VL) and vastus medialis oblique (VMO) were measured during forward walking and backward walking on a treadmill at grades of 0, 5 and 10%. The subjects walked for approximately 10 seconds at 4.0 km/h. The data were analyzed by repeated measuring of the two-way ANOVA and analyzed by a paired t-test between forward walking and backward walking. The SEMG activity levels of the RF, VL and VMO were the highest when both the forward walking and backward walking increased incrementally for treadmill grades of 0% to 10%, but the VMO/VL ratio had no significant changes. The SEMG activity levels of the RF, VL and VMO were significantly different between directions. However, SEMG activity levels of the RF, VL, VMO and VMO/VL ratio did not show significant difference among the treadmill grades. No statistically significant interactions were detected between the direction of walking and treadmill grade. Backward walking on the treadmill at 4 km/h and grades of 0%, 5%, 10% elicited a greater SEMG activity on the quadriceps muscles than did forward walking under the same conditions. The results suggest that the quadriceps may be effectively activated by performance at treadmill grades of 10%. This investigation confirms that backward walking up an incline may place additional muscular demands on individuals.

  • PDF

The Effect of Flavonoid Fraction Extracted from Rhus verniciflua Stokes on Sexual Behavior in SD Male Rats (옻나무 플라보노이드가 수컷 백서의 성행동에 미치는 영향)

  • Na Chun-Soo;Choi Bum-Rak;Choo Dong-Wan;Choi Won-Il;Kim Jin-Bum;Kim Hyun-Jung;Chung Yun Jun;Park Young In;Dong Mi-Sook
    • YAKHAK HOEJI
    • /
    • v.49 no.6
    • /
    • pp.471-476
    • /
    • 2005
  • Rhus verniciflua Stokes (RVS) has been used as a food supplement and a traditional herbal medicine for a men's sexual enhancement. In this study, we prepared a flavonoid fraction (RWE) from a hot water extract of RVS and its influence on sexual behavior was studied in male rats which were orally administered varying doses of RWE for 2 weeks. All doses of RWE stimulated sexual behavior in male rats such as reducing mounting latency and enhancing mount frequencies. However, intermission numbers were not changed and none of group can observe the ejaculation during behavioral testing time 5 min. Testosterone levels were Increased about 0$\∼$53$\%$ and 92$\∼$164$\%$ by the treatment of RWE for 1 and 2 weeks, respectively. However, estrogen levels in male rats tended to decrease in a dose dependent manner of RWE. At the dose of RWE 200 mg/kg, estrogen level was reduced to 77.5$\%$ and 70.3$\%$ of control after 1 and 2 weeks treatment. These findings suggest that the Rhus flavonoid fraction can stimulate the androgen-dependent male sexual behavior and it can be applied to the material of functional food for enhancing the sexual function.

Circuit Parameter Optimization and Significantly Enhanced ACPR of W-CDMA Signals of Feedforward Analog Optical Transmitter through Systemetic Approach (시스템적 접근을 통한 피드포워드 아날로그 광 송신기의 회로 파라미터 최적화와 W-CDMA 신호의 ACPR 개선)

  • Lee Joon-Jae;Park Sang-Hyun;Yun Young-Seol;Moon Yon-Tae;Choi Young-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.5 s.347
    • /
    • pp.17-24
    • /
    • 2006
  • The optical feedforward is known as a complicated technique in spite of its superior linearization. Here we optimized the feedforward circuit parameters using a systematic approach for optimum efficiency. A systematic approach was verified by transmission experiments of 2.14 GHz two tones. The compared third order IMD was enhanced by 38 dB for two-tone case. The experimental results for transmission of W-CDMA signals were described. The ACPR was enhanced by 20 dB for 1 W-CDMA carrier and by 16 dB for 3 W-CDMA carriers. Also, noise level was reduced by 7 dB.

High Speed Inductive Link Using Complementary Switching Transmitter and Integrating Receiver (상보적으로 스위칭하는 송신기와 적분형 수신기를 이용한 고속 인덕티브 링크)

  • Kim, Hyun-Ki;Roh, Joon-Wan;Chun, Young-Hyun;Kwon, Kee-Won;Chun, Jung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.12
    • /
    • pp.37-44
    • /
    • 2011
  • This paper presents the method of improving the data rate and BER in the inductive coupling link using a BPM signaling method. A complementary switching transmitter is used to remove invalid glitches at transmitted data, and the concept of pre-distortion is introduced to optimize received data. Also, an integrating receiver is used to increase the sampling margin and equalizing transistors are added in the pre-charge path of the integrator and comparator for high frequency operation. The transceiver designed with a 0.13 um CMOS technology operates at 2.4 Gb/s and consumes 5.99 mW from 1.2 V power supply.

1$\times$16 DMUX Using Holographic Volume Gratings (홀로그래픽 부피격자를 이용한 1$\times$16 DMUX)

  • Lee, Kwon-Yeon;An, Jun-Won;Kim, Nam;Lee, Hyun-Jae;Seo, Wan-Seok
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.5
    • /
    • pp.31-38
    • /
    • 2000
  • We propose a new photorefractive demultiplexer(DMUX) which can select the 16 channel signal in WDM optical communication system using the wavelength selectivity and the demultiplexing property through multiple recording of holographic volume grating in photorefractive Fe-LiNbO$_{3}$ crystal. For the multiple writing of the 16 channels having uniform diffraction efficiency, the rotation multiplexing technique and the exposure time schedule are used. Designed DMUX has the 16 channels with 0.5nm spacing between 670nm and 677.5nm and the bandwidth of 0.16nm. From the experimental results, the diffraction efficiency of each channel is 8.3 $\pm$0.62%, the optical loss from fresnel reflection and absorption on the crystal is 0.4cm-1, the 3㏈ bandwidth is 0.16 $\pm$0.005nm and the channel spacing is 0.46~0.5nm.

  • PDF

Design of an Infrared Multi-touch Screen Controller using Stereo Vision (스테레오 비전을 이용한 저전력 적외선 멀티 터치스크린 컨트롤러의 설계)

  • Jung, Sung-Wan;Kwon, Oh-Jun;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.2
    • /
    • pp.68-76
    • /
    • 2010
  • Touch-enabled technology is increasingly being accepted as a main communication interface between human and computers. However, conventional touchscreen technologies, such as resistive overlay, capacitive overlay, and SAW(Surface Acoustic Wave), are not cost-effective for large screens. As an alternative to the conventional methods, we introduce a newly emerging method, an optical imaging touchscreen which is much simpler and more cost-effective. Despite its attractive benefits, optical imaging touchscreen has to overcome some problems, such as heavy computational complexity, intermittent ghost points, and over-sensitivity, to be commercially used. Therefore, we designed a hardware controller for signal processing and multi-coordinate computation, and proposed Infrared-blocked DA(Dark Area) manipulation as a solution. While the entire optical touch control took 34ms with a 32-bit microprocessor, the designed hardware controller can manage 2 valid coordinates at 200fps and also reduce energy consumption of infrared diodes from 1.8Wh to 0.0072Wh.

Differential switching operation of vertical cavity laser with depleted optical thyristor for optical logic gates (광 로직 게이트 구현을 위한 차동구조 Vertical Cavity Laser - Depleted Optical Thyristor에 관한 연구)

  • Choi, Woon-Kyung;Kim, Doo-Gun;Choi, Young-Wan
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.7 s.361
    • /
    • pp.24-30
    • /
    • 2007
  • Latching optical switches and optical logic gates with AND or OR, and the INVERT functionality are demonstrated, for the first time, by the monolithic integration of a differential typed vertical cavity laser with depleted optical thyristor (VCL-DOT) structure with a low threshold current of 0.65 mA, a high slope efficiency of 0.38 mW/mA, and high sensitivity to input optical light. Many kinds of logic functions (AND, OR, NAND, NOR, and INVERT) are experimentally demonstrated using a differential switching operation scheme changing the intensity of a reference input beam without any changes of electrical circuits.

Seismic Performance Evaluation of Steel Moment Frames in Korea Using Nonlinear Dynamic Analysis (비선형동적해석을 통한 국내 철골 모멘트골조의 내진성능 평가)

  • Kim, Tae-Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • Domestic steel moment resisting frames were designed in accordance with the former KBC2005 and the current KBC2009, and then their seismic performance was evaluated in accordance with FEMA355F by utilizing nonlinear dynamic analysis. The results from the procedure in FEMA355F were different with those from the capacity spectrum method utilizing nonlinear static push-over analysis. In particular, the domestic steel moment resisting frames have a weak panel zone, so their behavior can be estimated more precisely by nonlinear dynamic analysis. The domestic steel moment resisting frames satisfied the performance goal if located at a site class $S_B$ or $S_C$, regardless of the story number and the response modification factor. However, if they are located at a site class $S_D$ or $S_E$, performance goal satisfaction cannot be guaranteed. No matter what standard is used for the design, KBC2005 or KBC2009, the domestic steel moment resisting frames may possess satisfactory seismic performance if the site condition is relatively good.