• Title/Summary/Keyword: S-Parameters Extraction Method

Search Result 122, Processing Time 0.028 seconds

A posteriori registration and subtraction of periapical radiographs for the evaluation of external apical root resorption after orthodontic treatment

  • Kreich, Eliane Maria;Chibinski, Ana Claudia;Coelho, Ulisses;Wambier, Leticia Stadler;Zedebski, Rosario de Arruda Moura;de Moraes, Mari Eli Leonelli;de Moraes, Luiz Cesar
    • Imaging Science in Dentistry
    • /
    • v.46 no.1
    • /
    • pp.17-24
    • /
    • 2016
  • Purposes: This study employed a posteriori registration and subtraction of radiographic images to quantify the apical root resorption in maxillary permanent central incisors after orthodontic treatment, and assessed whether the external apical root resorption (EARR) was related to a range of parameters involved in the treatment. Materials and Methods: A sample of 79 patients (mean age, $13.5{\pm}2.2years$) with no history of trauma or endodontic treatment of the maxillary permanent central incisors was selected. Periapical radiographs taken before and after orthodontic treatment were digitized and imported to the Regeemy software. Based on an analysis of the post-treatment radiographs, the length of the incisors was measured using Image J software. The mean EARR was described in pixels and relative root resorption (%). The patient's age and gender, tooth extraction, use of elastics, and treatment duration were evaluated to identify possible correlations with EARR. Results: The mean EARR observed was $15.44{\pm}12.1pixels$ (5.1% resorption). No differences in the mean EARR were observed according to patient characteristics (gender, age) or treatment parameters (use of elastics, treatment duration). The only parameter that influenced the mean EARR of a patient was the need for tooth extraction. Conclusion: A posteriori registration and subtraction of periapical radiographs was a suitable method to quantify EARR after orthodontic treatment, and the need for tooth extraction increased the extent of root resorption after orthodontic treatment.

LLE and SLM studies for Pd(II) separation using a thiodiglycolamide-based ligand

  • Kumbhaj, Shweta;Prabhu, Vandana;Patwardhan, Anand V.
    • Membrane and Water Treatment
    • /
    • v.9 no.6
    • /
    • pp.463-471
    • /
    • 2018
  • The present paper deals with the liquid-liquid extraction and flat sheet supported liquid membrane studies of Pd(II) separation from nitric acid medium using a novel synthesized ligand, namely, N,N,N',N'-tetraethyl-2,2-thiodiethanthiodiglycolamide (TETEDGA). The effect of various diluents and stripping reagents on the extraction of Pd(II) was studied. The liquid-liquid extraction studies showed complete extraction of Pd(II) in ~ 5 min. The influence of nitric acid and TETEDGA concentration on the distribution of Pd(II) has been investigated. The increase in nitric acid concentration resulted in increase in extraction of Pd(II). Stoichiometry of the extracted species was found to be $Pd(NO_3)_2{\cdot}TETEDGA$ by slope analysis method. Extraction studies with SSCD solution showed negligible uptake of Pt, Cr, Ni, and Fe, thus showing very high selectivity and extractability of TETEDGA for Pd(II). The flat sheet supported liquid membrane studies showed quantitative transport of Pd(II), ~99%, from the feed ($3M\;HNO_3$) to the strippant (0.02 M thiourea diluted in $0.4M\;HNO_3$) using 0.01 M TETEDGA as a carrier diluted in n-dodecane. Extraction time was ~160 min. Parameters such as feed acidity, TETEDGA concentration in membrane phase, membrane porosity etc. were optimized to achieve maximum transport rate. Permeability coefficient value of $2.66{\times}10^{-3}cm/s$ was observed using TETEDGA (0.01 M) as carrier, at 3 M, $HNO_3$ feed acidity across $0.2{\mu}m$ PTFE as membrane. The membrane was found to be stable over five runs of the operation.

Optimal EEG Locations for EEG Feature Extraction with Application to User's Intension using a Robust Neuro-Fuzzy System in BCI

  • Lee, Chang Young;Aliyu, Ibrahim;Lim, Chang Gyoon
    • Journal of Integrative Natural Science
    • /
    • v.11 no.4
    • /
    • pp.167-183
    • /
    • 2018
  • Electroencephalogram (EEG) recording provides a new way to support human-machine communication. It gives us an opportunity to analyze the neuro-dynamics of human cognition. Machine learning is a powerful for the EEG classification. In addition, machine learning can compensate for high variability of EEG when analyzing data in real time. However, the optimal EEG electrode location must be prioritized in order to extract the most relevant features from brain wave data. In this paper, we propose an intelligent system model for the extraction of EEG data by training the optimal electrode location of EEG in a specific problem. The proposed system is basically a fuzzy system and uses a neural network structurally. The fuzzy clustering method is used to determine the optimal number of fuzzy rules using the features extracted from the EEG data. The parameters and weight values found in the process of determining the number of rules determined here must be tuned for optimization in the learning process. Genetic algorithms are used to obtain optimized parameters. We present useful results by using optimal rule numbers and non - symmetric membership function using EEG data for four movements with the right arm through various experiments.

The Peculiarities of New Textile Hand Evaluation Method

  • Eugenija, Strazdiene;Matas, Gutauskas
    • Fibers and Polymers
    • /
    • v.7 no.4
    • /
    • pp.414-419
    • /
    • 2006
  • The paper presents information concerning metrological and technical characteristics of KTU-Griff-Tester device, the optimization of its parameters and the cases of its application. It was defined that the behaviour of textile material during its extraction through a rounded hole depends upon its structure. Variations of geometrical shape of woven and knitted specimens can be described by mathematical expressions of shortened epicycloids and Cassini ovals. It is shown that waving process of disc shaped specimen can be predicted on the basis of the law of sine curve. The examples of textiles treatment with different types of commercial softeners are presented, herewith showing the suitability (sensitiveness) of the new device to detect the changes of textile hand. Meantime it is shown that the level of materials anisotropy can be decided on the basis of transformations of specimen's geometrical shape.

Analytical Methods for the Extraction of PV panel Single-Diode model parameters from I-V Characteristic (I-V 특성곡선을 통한 태양전지 패널의 모델 파라미터 추출 방법)

  • Choi, Sung-Won;Ryu, Ji-Hyung;Lee, Chang-Goo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.2
    • /
    • pp.847-851
    • /
    • 2011
  • Photovoltaic System is increasing install capacity based on environmental-friendly characteristics. It have been actively studied to improve the efficiency. In order to design highly efficient system, it is important to understand the output characteristics of solar panels. The single diode model can represent the physical characteristics of solar panel. But it needs complex process such as mutli-step measurement and numerical analysis to get the exact parameters. In this paper, The method for extracting characteristic parameters of the single diode model based on the I-V characteristic curves in the panel manufacturer's data-sheet is presented. To verify the proposed method, solar cell model constructed in simulink. Simulink model output compared with output graph in datasheet.

Accurate RF C-V Method to Extract Effective Channel Length and Parasitic Capacitance of Deep-Submicron LDD MOSFETs

  • Lee, Sangjun;Lee, Seonghearn
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.6
    • /
    • pp.653-657
    • /
    • 2015
  • A new paired gate-source voltage RF capacitance-voltage (C-V) method of extracting the effective channel length and parasitic capacitance using the intersection between two closely spaced linear regression lines of the gate capacitance versus gate length measured from S-parameters is proposed to remove errors from conventional C-V methods. Physically verified results are obtained at the gate-source voltage range where the slope of the gate capacitance versus gate-source voltage is maximized in the inversion region. The accuracy of this method is demonstrated by finding extracted value corresponding to the metallurgical channel length.

A Study on Signal Feature Extraction of Partial Discharge Types Using Discrete Wavelet Transform Technique (이산웨이블렛 변환기법을 이용한 부분방전종류의 신호특징추출에 관한연구)

  • Park, Jae-Jun;Jeon, Byung-Hoon;Kim, Jin-Seong;Jeon, Hyun-Gu;Baek, Kwan-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.170-176
    • /
    • 2002
  • In this papers, we proposed the feature extraction method due to partial discharge type of transformers. For wavelet transform, Daubechie's filter is used, we can obtain wavelet coefficients which is used to extract feature of statistical parameters (maximum value, average value, dispersion, skewness, kurtosis) about acoustic emission signal generated from each partial discharge type. The defects which could occur in a transformer were simulated by using needle-plane electrode, IEC electrode and Void electrode. Also, these coefficients are used to identify signal of partial discharge type electrode fault in transformer. As a result, from compare of acoustic emission amplitude and acoustic average value, we are obtained results of IEC electrode> Void electrode> Needle-Plane electrode. otherwise, In case of skewness and kurtosis, we are obtained results of Needle-Plane electrode electrode> Void electrode> IEC electrode.

  • PDF

Feature Extraction of Shape of Image Objects in Content-based Image Retrieval (내용기반으로한 이미지 검색에서 이미지 객체들의 외형특징추출)

  • Cho, June-Suh
    • The KIPS Transactions:PartB
    • /
    • v.10B no.7
    • /
    • pp.823-828
    • /
    • 2003
  • The main objective of this paper is to provide a methodology of feature extraction using shape of image objects for content-based image retrieval. The shape of most real-life objects is irregular, and hence there is no universal approach to quantify the shape of an arbitrary object. In particular. electronic catalogs contain many image objects for their products. In this paper, we perform feature extraction based on individual objects in images rather than on the whole image itself, since our method uses a shape-based approach of objects using RLC lines within an image. Experiments show that shape parameters distinctly represented image objects and provided better classification and discrimination among image objects in an image database compared to Texture.

Boundary Extraction Using Statistical Edge and Curvature Model

  • Park, Hae-Chul;Lee, J. S.;H. C. Shin;J. H. Cho;Kim, S. D.
    • Proceedings of the IEEK Conference
    • /
    • 2001.09a
    • /
    • pp.403-406
    • /
    • 2001
  • We propose an algorithm for extracting the boundary of an object. In order to take full advantage of global shape, our approach uses global shape parameters derived from Point Distribution Model (PDM). Unlike PDM, the proposed method models global shape using curvature as well as edge. The objective function of applying the shape model is formulated using Bayesian rule. We can extract the boundaries of an object by evaluating iteratively the solution maximizing the objective function. Experimental results show that the proposed method can reduce computation cost than the PDM and it is robust to noise, pose variation, and some occlusion.

  • PDF

Effective determination of nicotine enantiomers from e-liquids and biological fluids by high performance liquid chromatography (HPLC) using dispersive liquid-liquid microextraction (DLLME)

  • Song, Seunghoon;Myung, Seung-Woon
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.180-190
    • /
    • 2021
  • This study compared the efficacy of chiral GC and chiral HPLC for the analysis of nicotine. To develop a suitable dispersive liquid-liquid microextraction (DLLME) method, the following parameters were optimized: pH, extraction solvent, dispersive solvent, type and quantity of salt, and laboratory temperature. The validation of the method was carried out by the established HPLC method. The LODs were 0.11 ㎍/mL and 0.17 ㎍/mL for the (S)- and (R)- enantiomers, respectively. The LOQs were 0.30 ㎍/mL and 0.44 ㎍/mL, respectively. The optimal calibration range was between 0.30-18 ㎍/mL and 0.44-4.40 ㎍/mL, respectively, and the correlation coefficient (r2) was 0.9978-0.9996. The intra-day accuracy was 79.9-110.6 %, and the intra-day precision was 1.3-12.0 %. The inter-day accuracy was 87.8-108.0 %, and the inter-day precision was 4.0-12.8 %. E-liquid and biological fluids (urine and saliva) were analyzed using the established method.