• Title/Summary/Keyword: S-Parameters Extraction Method

Search Result 122, Processing Time 0.028 seconds

Extraction of Extrinsic Parameters for GaAs MESFET by S-parameters (S-파라미터를 이용한 GaAs MESFET의 외부 파라미터 추출)

  • 조영송;나극환;박광호;신철재
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.2 no.2
    • /
    • pp.30-37
    • /
    • 1991
  • The modified method which determines the extrinsic parameters at the small signal equivalent model for GaAs MESFET is presented. It is important that extrinsic parameters are completely eliminated, in order to calculate exact intrinsic parameters. Extrinsic circuit is established by transmission lines, parasitic inductors and capacitors. After these are extracted by S-parameters, intrinsic parameters are calculated. Especially, frequency dependence of parastic inductance and capacitance is considerally constant.

  • PDF

Determination of VOC in aqueous samples by the combination of headspace (HS) and solid-phase microextraction (SPME) (HS-SPME 방식에 기초한 물 중 VOC 성분의 분석기법에 대한 연구: 3가지 실험 조건의 변화와 분석감도의 관계)

  • Park, Shin-Young;Kim, Ki-Hyun;Yang, H.S.;Ha, Joo-Young;Lee, Ki-Han;Ahn, Ji-Won
    • Analytical Science and Technology
    • /
    • v.21 no.2
    • /
    • pp.93-101
    • /
    • 2008
  • The application of solid phase microextraction (SPME) is generally conducted by directly immersing the fiber into the liquid sample or by exposing the fiber in the head space (HS). The extraction temperature, the time of incubation, and application of stirring are often designated to be the most important parameters for achieving the best extraction efficiencies of HS-SPME analysis. In this study, relative importance of these three analytical parameters involved in the HS-SPME method is evaluated using a polydimethylsiloxane/carboxen (PDMS/CAR) fiber. To optimize its operation conditions the competing relationships between different parameters were investigated by comparing the extraction efficiency based on the combination of three parameters and two contracting conditions: (1) heating the sample at 30 vs. 50 C, (2) exposing samples at two durations of 10 vs. 30 min, and (3) application of stirring vs. no stirring. According to our analysis among 8 combination types of HS-SPME method, an extraction condition termed as S50-30 condition ((1) 1200 rpm stirring, (2) $50^{\circ}C$ exposure temp, and (3) 30 min exposure duration) showed maximum recovery rate of 45.5~68.5% relative to an arbitrary reference of direct GC injection. According to this study, the employment of stirring is the most crucial factor to improve extraction efficiency in the application of HS-SPME.

Analysis of Flavor Composition of Coriander Seeds by Headspace Mulberry Paper Bag Micro-Solid Phase Extraction

  • Cha, Eun-Ju;Won, Mi-Mi;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.11
    • /
    • pp.2675-2679
    • /
    • 2009
  • This paper reports the example of headspace mulberry paper bag micro solid phase extraction (HS-MPB-$\mu$-SPE) as a new sampling method for the determination of volatile flavor composition of coriander seeds. Adsorption efficiencies between two configurations of mulberry paper bag were compared, and several parameters affecting the HS-MPB-$\mu$-SPE were investigated and optimized. The optimized technique uses an adsorbent (Tenax TA, 0.1 mg) contained in a mulberry paper bag of front configuration where fine surface was outside, and minimal amount of organic solvent (0.6 mL). Linalool and $\gamma$-terpinene were found as abundant flavor compounds from coriander seeds. The limit of detection (LOD) and the limit of quantitation (LOQ) for linalool of major flavor in coriander seeds were 10.3 ng/mL and 34.4 ng/mL, respectively. The proposed method showed good reproducibility and good recovery. The HS-MPB-$\mu$-SPE is very simple to use, inexpensive, requires small sample amounts and solvent consumption. Because the solvent for extraction is reduced to only a very small volume, there is minimal waste or exposure to toxic organic solvent and no further concentration step.

Accurate RF Extraction Method for Gate Voltage-Dependent Carrier Velocity of Sub-0.1㎛ MOSFETs in the Saturation Region (Sub-0.1㎛ MOSFET의 게이트전압 종속 캐리어 속도를 위한 정확한 RF 추출 방법)

  • Lee, Seonghearn
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.9
    • /
    • pp.55-59
    • /
    • 2013
  • A new method using RF Ids determined from measured S-parameters is proposed to extract the gate-voltage dependent effective carrier velocity of bulk MOSFETs in the saturation region without additional dc Ids measurement data suffering parasitic resistance effect that becomes larger with continuous down-scaling to sub-$0.1{\mu}m$. This method also allows us to extract the carrier velocity in the saturation region without the difficult extraction of bias-dependent parasitic gate-source capacitance and effective channel length. Using the RF technique, the electron velocity overshoot exceeding the bulk saturation velocity is observed in bulk N-MOSFETs with a polysilicon gate length of $0.065{\mu}m$.

A Novel External Resistance Method for Extraction of Accurate Effective Channel Carrier Mobility and Separated Parasitic Source/Drain Resistances in Submicron n-channel LDD MOSFET's (새로운 ERM-방법에 의한 미세구조 N-채널 MOSFET의 유효 캐리어 이동도와 소스 및 드레인 기생저항의 정확한 분리 추출)

  • Kim, Hyun-Chang;Cho, Su-Dong;Song, Sang-Jun;Kim, Dea-Jeong;Kim, Dong-Myong
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.37 no.12
    • /
    • pp.1-9
    • /
    • 2000
  • A new method, the external resistance method (ERM method), is proposed for accurate extraction of the gate bias-dependent effective channel carrier mobility (${\mu}_{eff}$) and separated parasitic source/drain resistances ($R_S$ and $R_D$) of n-channel MOSFET's. The proposed ERM method is applied to n-channel LDD MOSFETs with two different gate lengths ($W_m/L_m=30{\mu}m/0.6{\mu}m,\;30{\mu}m/1{\mu}m$) in the linear mode of current-voltage characteristics ($I_D-V_{GS},\;V_{DS}$). We also considered gate voltage dependence of separated $R_2$ and $R_D$ in the accurate modeling and extraction of effective channel carrier mobility. Good agreement of experimental data is observed in submicron n-channel LDD MOSFETs. Combining with capacitance-voltage characteristics, the ERM method is expected to be very useful for accurate and efficient extraction of ${\mu}_{eff},\;R_D,\;R_S$, and other characteristic parameters in both symmetric and asymmetric structure MOSFET's in which parasitic resistances are critical to the improvement of high speed performance and reliability.

  • PDF

New RF Empirical Nonlinear Modeling for Nano-Scale Bulk MOSFET (나노 스케일 벌크 MOSFET을 위한 새로운 RF 엠피리컬 비선형 모델링)

  • Lee, Seong-Hearn
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.12 s.354
    • /
    • pp.33-39
    • /
    • 2006
  • An empirical nonlinear model with intrinsic nonlinear elements has been newly developed to predict the RF nonlinear characteristics of nano-scale bulk MOSFET accurately over the wide bias range. Using an extraction method suitable for nano-scale MOSFET, the bias-dependent data of intrinsic model parameters have been accurately obtained from measured S-parameters. The intrinsic nonlinear capacitance and drain current equations have been empirically obtained through 3-dimensional curve-fitting to their bias-dependent curves. The modeled S-parameters of 60nm MOSFET have good agreements with measured ones up to 20GHz in the wide bias range, verifying the accuracy of the nano-scale MOSFET model.

Headspace Hanging Drop Liquid Phase Microextraction and Gas Chromatography-Mass Spectrometry for the Analysis of Flavors from Clove Buds

  • Jung, Mi-Jin;Shin, Yeon-Jae;Oh, Se-Yeon;Kim, Nam-Sun;Kim, Kun;Lee, Dong-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.2
    • /
    • pp.231-236
    • /
    • 2006
  • A novel sample pretreatment technique, headspace hanging drop liquid phase microextraction (HS-LPME) was studied and applied to the determination of flavors from solid clove buds by gas chromatography-mass spectrometry (GC-MS). Several parameters affecting on HS-LPME such as organic solvent drop volume, extraction time, extraction temperature and phase ratio were investigated. 1-Octanol was selected as the extracting solvent, drop size was fixed to 0.6 $\mu$L. 60 min extraction time at 25 ${^{\circ}C}$ was chosen. HS-LPME has the good efficiency demonstrated by the higher partition equilibrium constant ($K_{lh}$) values and concentration factor (CF) values. The limits of detection (LOD) were 1.5-3.2 ng. The amounts of eugenol, $\beta$-caryophyllene and eugenol acetate from the clove bud sample were 1.90 mg/g, 1.47 mg/g and 7.0 mg/g, respectively. This hanging drop based method is a simple, fast and easy sample enrichment technique using minimal solvent. HSLPME is an alternative sample preparation method for the analysis of volatile aroma compounds by GC-MS.

Electrochemically polyaniline-coated microextraction needle for phthalates in water

  • Hwang, Yura;Lee, Yelin;Ahn, Soyoung;Bae, Sunyoung
    • Analytical Science and Technology
    • /
    • v.33 no.2
    • /
    • pp.76-85
    • /
    • 2020
  • A stainless-steel needle (Hamilton 90022, 22 gauge, 718-㎛ o.d., 413-㎛ i.d., 51-mm length, bevel tip) with an electrochemically coated polyaniline layer having a microbore tunnel was newly prepared as a device for headspace in-needle microextraction. For designing the needle, the polyaniline layer length was optimized, and to evaluate the extraction efficiency for polycyclic aromatic hydrocarbons, numerous cyclic voltammetry scans were conducted. In addition, the optimization of the analytical conditions (including the adsorption and desorption parameters) and the validation of the analytical method were conducted. The optimized adsorption and desorption conditions were 40 ℃ for 30 min and 230 ℃ for 60 s, respectively. Finally, in this study, a polyaniline layer was electrochemically deposited on the in-needle surface, and it exhibited good thermal stability. The needle with the polyaniline layer was repeatedly used more than 200 times during this study. This method has some advantages in terms of the extraction time, extraction efficiency, and analysis cost.

A New Small-Signal Modeling Method of HEMT Using Weakly Pinched-Off Cold-HEMT (약하게 핀치오프된 Cold-HEMT를 이용한 새로운 HEMT 소신호 모델링 기법)

  • 전만영
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.4
    • /
    • pp.743-749
    • /
    • 2003
  • By biasing the gate of cold-HEMT with a voltage slightly lower than the pinch-off point, a new small-signal modeling method that is free from gate degradation problem and requires no additional DC measurement is proposed in this paper. The method has shown excellent agreement between modeled and measured S-parameters up to 62 GHz at 49 different normal operating bias points.

A Study on the GaAs MESFET Model Parameter Extraction (GaAs MESFET 모델 매개변수 추출에 관한 연구)

  • 박의준;박진우
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.7
    • /
    • pp.628-639
    • /
    • 1991
  • A new efficient method for GaAs MESFET model parameter extraction is proposed, which is based on the bias dependance of each parameter characteristics derved from the analytic model. The requiremnts of the method are only small-signal S-parameter measurements under the three bias variations. Fixation of the linear model parameter values in the optimization process is made using the sensitivity information of the model parameter obtained by the weighted Broyden update method, it is to improve the uniqueness and reliablility of the solution. The validity of the extracted values of the FET model parameters is confirmed by comparing the simulation results with the experimental data.

  • PDF