• Title/Summary/Keyword: S-Parameter

Search Result 5,722, Processing Time 0.042 seconds

Bond Characteristics and Splitting Bond Stress on Steel Fiber Reinforced Reactive Powder Concrete (강섬유로 보강된 반응성 분체 콘크리트의 부착특성과 쪼갬인장강도)

  • Choi, Hyun-Ki;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.651-660
    • /
    • 2014
  • Structural members using ultra high strength concrete which usually used with steel fiber is designed with guidelines based on several investigation of SF-RPC(steel fiber reinforced reactive powder concrete). However, there are not clear design method yet. Especially, SF-RPC member should be casted with steam(90 degree delicious) and members with SF-RPC usually used with precast members. Although the most important design parameter is development method between SF-RPC and steel reinforcement(rebar), there are no clear design method in the SF-RPC member design guidelines. There are many controversial problems on safety and economy. Therefore, in order to make design more optimum safe design, in this study, we investigated bond stress between steel rebar and SF-RPC according to test. Test results were compared with previously suggested analysis method. Test was carried out with direct pull out test using variables of compressive strength of concrete, concrete cover and inclusion ratio of steel fiber. According to test results, bond stress between steel rebar and SF-RPC increased with increase of compressive strength of concrete and concrete cover. Increasing rate of bond stress were decrease with increase of compressive strength of SF-RPC and concrete cover significantly. 1% volume fraction inclusion of steel fiber increase the bond stress between steel rebar and SF-RPC with two times but 2% volume fraction cannot affect the bond stress significantly. There are no exact or empirical equations for evaluation of SF-RPC bond stress. In order to make safe bond design of SF-RPC precast members, previously suggested analysis method for bond stress by Tepfers were evaluated. This method have shown good agreement with test results, especially for steel fiber reinforced RPC.

Studies on the Post-hatching Development of Sertoli and Leydig Cells in the Testis of Korean Native Chickens (한국재래 닭 고환 지지세포와 간질세포의 부화 후 발달에 관한 연구)

  • Tae H. J.;Jang B. G.;Choi C. H.;Park Y. J.;Yang H. H.;Kim I. S.
    • Korean Journal of Poultry Science
    • /
    • v.32 no.2
    • /
    • pp.125-133
    • /
    • 2005
  • Morphometric changes in testicular Sertoli and Leydig cells from hatching to adulthood were studied using Korean native chickens of 1, 2, 4, 6, 8, 10, 12, 14, 16, 18, 21, 24, 28, 32, 44, 52 and 64 weeks (n=13 chickens per group) of age. The objective of this study was to understand the developmental phase of the Sertoli and Leydig cells with age. Testis of chickens was fixed by whole body perfusion using a fixative containing $2.5\%$ glutaraldehyde in cacodylate buffer, processed and embedded in Epon-araldite. Using 1 Um sections stained with methylene blue-azure II, qualitative and quantitative (stereological) morphological studies were performed. The average volume of a testis of 1 week old Korean native chickens was determined as $0.148\;cm^3$ and the parameter increased linearly from 1 week to 21 weeks days $(28.86\;cm^3)$, and did not change from 21 weeks to 64 weeks. The volume density of the seminiferous tubules increased with age from $32.6\%$ at week 1 to $92.89\%$ at week 64. The volume density of the interstitium represents $67.4\%$ of the testicular parenchyma at week 1. This proportion progressively diminished during development to reach a value of $7.11\%$ at week 64. The volume density of the Leydig cells decreased almost linearly from 1 week $(4.9\%)$ to 14 weeks $(1.7\%)$ and remained unchanged thereafter. In contrast, the Sertoli cells occupied a volume density of $3.4\%$ at week 1, increased progressively up to 18 weeks of age $(10.79\%)$ and remained unchanged thereafter. The absolute volume of the Leydig and Sertoli cells per testis increased significantly from week 1 to week 21 but did not change significantly from week 24 to week 64. The number of Leydig cells per testis increased almost linearly from 1 week to 21 weeks, remained high and unchanged with advancing age. The number of Sertoli cells per testis increased gradually with age from 1 week to 14 weeks and remained unchanged thereafter.

Ad libitum Pasture Feeding in Late Pregnancy Does Not Improve the Performance of Twin-bearing Ewes and Their Lambs

  • Corner-Thomas, R.A.;Back, P.J.;Kenyon, P.R.;Hickson, R.E.;Ridler, A.L.;Stafford, K.J.;Morris, S.T.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.28 no.3
    • /
    • pp.360-368
    • /
    • 2015
  • The present study evaluated the effect of controlled ryegrass-white clover herbage availability from day 128 until day 142 of pregnancy in comparison to unrestricted availability, on the performance of twin-bearing ewes of varying body condition score (BCS; 2.0, 2.5, or 3.0) and their lambs. It was hypothesised that under conditions of controlled herbage availability, the performance of lambs born to ewes with a greater BCS would be greater than those born to ewes with a lower BCS. During the period that the nutritional regimens were imposed, the pre- and post-grazing herbage masses of the Control regimen ($1,070{\pm}69$ and $801{\pm}30$ kg dry matter [DM]/ha) were lower than the ad libitum regimen ($1,784{\pm}69$ and $1,333{\pm}33kg\;DM/ha$; p<0.05). The average herbage masses during lactation were $1,410{\pm}31kg\;DM/ha$. Nutritional regimen had no effect on ewe live weight, BCS and back fat depth or on lamb live weight, indices of colostrum uptake, maximal heat production, total litter weight weaned or survival to weaning (p>0.05). The difference in ewe BCSs and back fats observed among body condition groups was maintained throughout pregnancy (p<0.05). At weaning, ewes from the BCS2.0 group had lower BCS and live weight ($2.4{\pm}0.2$, $74.3{\pm}2.6kg$) than both the BCS2.5 ($2.6{\pm}0.2$, $78.6{\pm}2.4kg$) and BCS3.0 ewes ($2.7{\pm}0.2$, $79.0{\pm}2.6kg$; p<0.05), which did not differ (p>0.05). Ewe BCS group had no effect on lamb live weight at birth or weaning or on maximal heat production (p>0.05). Serum gamma glutamyl transferase concentrations of lambs born to BCS3.0 ewes were higher within 36 hours of birth than lambs born to BCS2.0 ewes and BCS2.5 ewes ($51.8{\pm}1.9$ vs $46.5{\pm}1.9$ and $45.6{\pm}1.9IU/mL$, respectively [p<0.05]). There was, however, no effect of ewe body condition on lamb plasma glucose concentration (p>0.05). Lamb survival was the only lamb parameter that showed an interaction between ewe nutritional regimen and ewe BCS whereby survival of lambs born to BCS2.5 and BCS3.0 ewes differed but only within the Control nutritional regimen ewes (p<0.05). These results indicate farmers can provide twin-bearing ewes with pre- and post-grazing ryegrass-white clover herbage covers of approximately 1,100 and 800 kg DM/ha in late pregnancy, provided that herbage covers are 1400 in lactation, without affecting lamb performance to weaning. The present results also indicate that under these grazing conditions, there is little difference in ewe performance within the BCS range of 2.0 to 3.0 and therefore they do not need to be managed separately.

The Relationship Between Son Preference and Fertility (남아 선호와 출산력간의 관계)

  • 이성용
    • Korea journal of population studies
    • /
    • v.26 no.1
    • /
    • pp.31-57
    • /
    • 2003
  • This study is intended to examine (l)whether the value of son-for example, old age security and succession of family lineage- causing son preference in the traditional society can be explained at the individual level, (2)whether women without son in the son preference country continue her childbearing until having at least one son or give up the desire of having a son at a certain level. To accomplish these purposes, the 1974 Korean National Fertility Survey data are analyzed by the quadratic hazard models controlling unobserved heterogeneity. Unlike ordinary regression model, even omitted variables that affect hazard rates and are uncorrelated with the included independent variables can distort the parameter estimates in the hazard model. Therefore the nonparametric maximum likelihood estimator(NPMLE) of a mixing distribution developed by Heckman and Singer is used to control unobserved heterogeneity. Based on the statistical result in this study, the value of son causing son preference is determined at the societal level, not at the individual level. And Korean women without a son did not continue endlessly childbearing during child bearing ages until having a son. In general, they gave up the desire having a son when she had born six daughters continuously. Thus, 30-40 years ago, the number of daughters that women without a son giving up the desire of son was six, which is about the level of total fertility rate during 1960s. In these days, we can often see many women who have only two or three daughters and do not any son. This means that the level of giving up the desire of son, which is one factor representing the strength of son preference, becomes lower. If the strength of son preference did not become much weaker, then the fertility rates in Korea could not reach the below replacement level.

The Application of Dynamic Acquisition with Motion Correction for Static Image (동적 영상 획득 방식을 이용한 정적 영상의 움직임 보정)

  • Yoon, Seok-Hwan;Seung, Jong-Min;Kim, Kye-Hwan;Kim, Jae-Il;Lee, Hyung-Jin;Kim, Jin-Eui;Kim, Hyun-Joo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.46-53
    • /
    • 2010
  • Purpose: The static image of nuclear medicine study should be acquired without a motion, however, it is difficult to acquire static image without movement for the serious patients, advanced aged patients. These movements cause decreases in reliability for quantitative and qualitative analysis, therefore re-examination was inevitable in the some cases. Consequently, in order to improve the problem of motion artifacts, the authors substituted the dynamic acquisition technique for the static acquisition, using motion correction. Materials and Methods: A capillary tube and IEC body phantom were used. First, the static image was acquired for 60 seconds while the dynamic images were acquired with a protocol, 2 sec/frame${\times}$30 frames, under the same parameter and the frames were summed up into one image afterwards. Also, minimal motion and excessive motion were applied during the another dynamic acquisition and the coordinate correction was applied towards X and Y axis on the frames where the motion artifact occurred. But the severe blurred images were deleted. Finally, the resolution and counts were compared between the static image and the summed dynamic images which before and after applying motion correction, and the signal of frequency was analysed after frequency spatial domain was transformed into 2D FFT. Supplementary examination, the blind test was performed by the nuclear medicine department staff. Results: First, the resolution in the static image and summed dynamic image without motion were 8.32 mm, 8.37 mm on X-axis and 8.30 mm, 8.42 mm on Y-axis, respectively. The counts were 484 kcounts, 485 kcounts each, so there was nearly no difference. Secondly, the resolution in the image with minimal motion applying motion correction was 8.66 mm on X-axis, 8.85 mm on Y-axis and had 469 kcounts while the image without motion correction was 21.81 mm, 24.02 mm and 469 kcounts in order. So, this shows the image with minimal motion applying motion correction has similar resolution with the static image. Lastly, the resolution in the images with excessive motion applying motion correction were 9.09 mm on X-axis, 8.83 mm on Y-axis and had 469 kcounts while the image without motion correction was 47.35 mm, 40.46 mm and 255 kcounts in order. Although there was difference in counts because of deletion of blurred frames, we could get similar resolution. And when the image was transformed into frequency, the high frequency was decreased by the movement. However, the frequency was improved again after motion correction. In the blind test, there was no difference between the image applying motion correction and the static image without motion. Conclusion: There was no significant difference between the static image and the summed dynamic image. This technique can be applied to patients who may have difficulty remaining still during the imaging process, so that the quality of image can be improved as well as the reliance for analysis of quantity. Moreover, the re-examination rate will be considerably decreased. However, there is a limit of motion correction, more time will be required to successfully image the patients applying motion correction. Also, the decrease of total counts due to deletion of the severe blurred images should be calculated and the proper number of frames should be acquired.

  • PDF

Comparison of Effectiveness about Image Quality and Scan Time According to Reconstruction Method in Bone SPECT (영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교)

  • Kim, Woo-Hyun;Jung, Woo-Young;Lee, Ju-Young;Ryu, Jae-Kwang
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.9-14
    • /
    • 2009
  • Purpose: Nowadays in the nuclear medicine, many studies and efforts are being made to reduce the scan time, as well as the waiting time to be needed to execute exams after injection of radionuclide medicines. Several methods are being used in clinic, such as developing new radionuclide compounds that enable to be absorbed into target organs more quickly and reducing acquisition scan time by increase the number of Gamma Camera detectors to examine. Each medical equipment manufacturer has improved the imaging process techniques to reduce scan time. In this paper, we tried to analyze the difference of image quality between FBP, 3D OSEM reconstruction methods that commercialized and being clinically applied, and Astonish reconstruction method (A kind of Iterative fast reconstruction method of Philips), also difference of image quality on scan time. Material and Methods: We investigated in 32 patients that examined the Bone SPECT from June to July 2008 at department of nuclear medicine, ASAN Medical Center in Seoul. 40sec/frame and 20sec/frame images were acquired that using Philips‘ PRECEDENCE 16 Gamma Camera and then reconstructed those images by using the Astonish (Philips’ Reconstruction Method), 3D OSEM and FBP methods. The blinded test was performed to the clinical interpreting physicians with all images analyzed by each reconstruction method for qualitative analysis. And we analyzed target to non target ratio by draws lesions as the center of disease for quantitative analysis. At this time, each image was analyzed with same location and size of ROI. Results: In a qualitative analysis, there was no significant difference by acquisition time changes in image quality. In a quantitative analysis, the images reconstructed Astonish method showed good quality due to better sharpness and distinguish sharply between lesions and peripheral lesions. After measuring each mean value and standard deviation value of target to non target ratio with 40 sec/frame and 20sec/frame images, those values are Astonish (40 sec-$13.91{\pm}5.62$ : 20 sec-$13.88{\pm}5.92$), 3D OSEM (40 sec-$10.60{\pm}3.55$ : 20 sec-$10.55{\pm}3.64$), FBP (40 sec-$8.30{\pm}4.44$ : 20 sec-$8.19{\pm}4.20$). We analyzed target to non target ratio from 20 sec and 40 sec images. And we analyzed the result, In Astonish (t=0.16, p=0.872), 3D OSEM (t=0.51, p=0.610), FBP (t=0.73, p=0.469) methods, there was no significant difference statistically by acquisition time change in image quality. But FBP indicates no statistical differences while some images indicate difference between 40 sec/frame and 20 sec/frame images by various factors. Conclusions: In the circumstance, try to find a solution to reduce nuclear medicine scan time, the development of nuclear medicine equipment hardware has decreased while software has marched forward at a relentless. Due to development of computer hardware, the image reconstruction time was reduced and the expanded capacity to restore enables iterative methods that couldn't be performed before due to technical limits. As imaging process technique developed, it reduced scan time and we could observe that image quality keep similar level. While keeping exam quality and reducing scan time can induce the reduction of patient's pain and sensory waiting time, also accessibility of nuclear medicine exam will be improved and it provide better service to patients and clinical physician who order exams. Consequently, those things make the image of department of nuclear medicine be improved. Concurrent Imaging - A new function that setting up each image acquisition parameter and enables to acquire images simultaneously with various parameters to once examine.

  • PDF

A Knowledge-based Approach for the Estimation of Effective Sampling Station Frequencies in Benthic Ecological Assessments (지식기반적 방법을 활용한 저서생태계 평가의 유효 조사정점 개수 산정)

  • Yoo, Jae-Won;Kim, Chang-Soo;Jung, Hoe-In;Lee, Yong-Woo;Lee, Man-Woo;Lee, Chang-Gun;Jin, Sung-Ju;Maeng, Jun-Ho;Hong, Jae-Sang
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.16 no.3
    • /
    • pp.147-154
    • /
    • 2011
  • Decision making in Environmental Impact Assessment (EIA) and Consultation on the Coastal Area Utilization (CCAU) is footing on the survey reports, thus requires concrete and accurate information on the natural habitats. In spite of the importance of reporting the ecological quality and status of habitats, the accumulated knowledge and recent techniques in ecology such as the use of investigated cases and indicators/indices have not been utilized in evaluation processes. Even the EIA report does not contain sufficient information required in a decision making process for conservation and development. In addition, for CCAU, sampling efforts were so limited that only two or a few stations were set in most study cases. This hampers transferring key ecological information to both specialist review and decision making processes. Hence, setting the effective number of sampling stations can be said as a prior step for better assessment. We introduced a few statistical techniques to determine the number of sampling stations in macrobenthos surveys. However, the application of the techniques requires a preliminary study that cannot be performed under the current assessment frame. An analysis of the spatial configuration of sampling stations from 19 previous studies was carried out as an alternative approach, based on the assumption that those configurations reported in scientific journal contribute to successful understanding of the ecological phenomena. The distance between stations and number of sampling stations in a $4{\times}4$ km unit area were calculated, and the medians of each parameter were 2.3 km, and 3, respectively. For each study, approximated survey area (ASA, $km^2$) was obtained by using the number of sampling stations in a unit area (NSSU) and total number of sampling stations (TNSS). To predict either appropriate ASA or NSSU/TNSS, we found and suggested statistically significant functional relationship among ASA, survey purpose and NSSU. This empirical approach will contribute to increasing sampling effort in a field survey and communicating with reasonable data and information in EIA and CCAU.

The Effects on Dose Distribution Characteristics by Changing Beam Tuning Parameters of Digital Linear Accelerator in Medicine (의료용 디지털 선형가속기의 빔조정 인자변화가 선량분포특성에 미치는 영향)

  • 박현주;이동훈;이동한;권수일;류성렬;지영훈
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.17-22
    • /
    • 1999
  • INJ-I, INJ-E, PFN, BMI, and PRF were selected among the various factors which constitute a digital linear accelerator to find effects on the dose distribution by changing current and voltage within the permitted scale which Mevatron automatically maintained. We measured the absorbed dose using an ion chamber, analyzed the waveform of beam output using an oscilloscope, and measured symmetry and flatness using a dosimetry system. An RFA plus (Scanditronix, Sweden) device was used as a dosimetry system. Then an 0.6cc ion chamber (PR06C, USA), an electrometer (Capintec192, USA), and an oscilloscope (Tektronix, USA) were employed to measure the changes on the dose distribution characteristics by changing the beam-tuning parameters. When the currents and the voltages of INJ-I, INJ-E, PFN, BMI, and PRF were modified, we were able to see the notable change on the dose rate by examining the change of the output pulse using the oscilloscope and by measuring them using the ion chamber. However, the results of energy and flatness graph from RF A plus were almost identical. The factors had fine differences: INJ-I, INJ-E, PFN, BMI, and PRF had 0.01∼0.02% differences in D10/D20, 0.1∼0.2 % differences in symmetry, and 0.1∼0.4% differences in flatness. Since Mevatron controlled itself automatically to keep the reference value of the factor, it was not able to see large differences in the dose distribution. There were fine differences on the dose rate distribution when the voltage and the currents of the digitized factors were modified Nonetheless, a basic operational management information was achieved.

  • PDF

Mineralogy and Geochemistry of Quaternary Fault Gouges in the Southeastern Korean Peninsula (한반도 동남부 제4기 단층 비지의 광물학적 및 지구화학적 연구)

  • 손승완;장태우;김영규
    • Journal of the Mineralogical Society of Korea
    • /
    • v.15 no.2
    • /
    • pp.85-94
    • /
    • 2002
  • XRF, XRD, EPMA have been used to investigate microstructures and mineralogical changes caused by the faulting and fluids associated with faulting in the Quaternary fault gouge zones at the Sangchon, Ipsil and Wangsan faults located at the southeastern part of the Korean Peninsula. The chemical compositions of faulted rocks and protoliths analyzed by XRF show that the fault gouges are relatively enriched in TiO$_2$, P$_2$O$_{5}$, MgO, and Fe$_2$O$_3$) compared with protoliths, indicating that the fluids associated with faulting were highly activated. XRD results show that the fault gouges predominantly consist of quartz, feldspar, calcite and clay minerals. Clay minerals formed in the gouge zones are mainly composed of smectite characterized by a dioctahedral sheet. Based on EPMA analyses various kinds of sulfide, carbonate, phosphate minerals were identified in the gouge zones and protoliths. Xenotime of grey fault gouge of the Sangchon fault and sulfide minerals of contact andesitic rock of Ipsil fault and contact grey andesitic rock of Wangsan fault were probably formed by inflow of hydrothermal solution associated with faulting prior to the Quaternary. Carbonate minerals of contact andesitic rock and gouge zone of the Ipsil fault were formed by inflow of fluid associated with faulting prior to the Quaternary. They are heavily fractured and have reaction rim on their edge, indicating that faultings and inflow of fluids were highly activated after carbonate minerals were formed. Calcites of Wangsan fault seemed to be formed in syntectonic or posttectonic Quaternary faulting.g.

Runoff of Endosulfan by Rainfall Simulation and from Soybean-grown Field Lysimeter (인공강우와 콩재배 포장 라이시메타를 이용한 endosulfan의 유출량 평가)

  • Kim, Chan-Sub;Lee, Hee-Dong;Ihm, Yang-Bin;Im, Geon-Jae
    • Korean Journal of Environmental Agriculture
    • /
    • v.26 no.4
    • /
    • pp.343-350
    • /
    • 2007
  • Three different experiments were carried out to investigate the runoff and erosion losses of endosulfan from sloped-field by rainfall. The mobility of endosulfan and which phase it was transported by were examined in adsorption study, the influence of rainfall pattern and slope degree on the pesticide loss were evaluated in simulated rainfall study, and the pesticide losses from soybean-grown field comparing with bare soil were measured in field lysimeter study. Adsorption parameter (K) of endosulfan ranged from 77 to 131 by adsorption method and K values by the desorption method were higher than those by the adsorption method. By the SSLRC's classification for pesticide mobility endosulfan was classified as non-mobile class ($K_{oc}>4,000$). Runoff and erosion loss of endosulfan by three rainfall scenarios ranged from 3.4 to 5.6%and from 4.4 to 15.6%of the amount treated. Endosulfan residues were mainly remained at the top 5 cm of soil depth after the simulated rainfall study. Pesticide loss in case of 30%-slope degree ranged from 0.6 to 0.9 times higher than those in case of 10%-slope degree. The difference of pesticide runoff loss was related with its concentration in runoff water and the difference of pesticide erosion loss would related closely with the quantity of soil eroded. Endosulfan losses from a series of lysimeter plots in sloped land by rainfall ranged from 5 to 35% of the amount treated. The erosion rate of endosulfan from soybean-plots was 66% of that from bare soil plots. The effect of slope conditions was not great for runoff loss, but was great for erosion loss as increasing to maximum $4{\sim}12$ times with slope degree and slope length. The peak runoff concentration of endosulfan in soybean-plots and bare soil plots ranged from 8 to 10 and from 7 to $9{\mu}gL^{-1}$ on nine plots with different slope degree and slope length. Therefore the difference of the peak runoff concentrations between bare soil plots and soybean-plots were not great.