• Title/Summary/Keyword: S-Dot

Search Result 497, Processing Time 0.03 seconds

Preparation of graphene oxide incorporated polyamide thin-film composite membranes for PPCPs removal

  • Wang, Xiaoping;Li, Nana;Zhao, Yu;Xia, Shengji
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.211-220
    • /
    • 2018
  • Incorporating nano-materials in thin-film composite (TFC) membranes has been considered to be an approach to achieve higher membrane performance in various water treatment processes. This study investigated the rejection efficiency of three target compounds, i.e., reserpine, norfloxacin and tetracycline hydrochloride, by TFC membranes with different graphene oxide proportions. Graphene oxide (GO) was incorporated into the polyamide active layer of a TFC membrane via an interfacial polymerization (IP) reaction. The TFC membranes were characterized with FTIR, FE-SEM, AFM; in addition, the water contact angle measurements as well as the permeation and separation performance were evaluated. The prepared GO-TFC membranes exhibited a much higher flux ($3.11{\pm}0.04L/m2{\cdot}h{\cdot}bar$) than the pristine TFC membranes ($2.12{\pm}0.05L/m2{\cdot}h{\cdot}bar$) without sacrificing their foulant rejection abilities. At the same time, the GO-modified membrane appeared to be less sensitive to pH changes than the pure TFC membrane. A significant improvement in the anti-fouling property of the membrane was observed, which was ascribed to the favorable change in the membrane's hydrophilicity, surface morphology and surface charge through the addition of an appropriate amount of GO. This study predominantly improved the understanding of the different PA/GO membranes and outlined improved industrial applications of such membranes in the future.

Study of transfer film in the sliding of nanoscale CuO-filled and fiber-reinforced polyphenylene sulfide (PPS) composites (CuO nanoparticle 및 fiber 로 구성된 PPS 복합재료의 sliding 조건하의 transfer film 에관한 연구)

  • Cho, Min-Haeng;Bahadur, Shyam;Park, Hye-Young;Kim, Yoon-Jun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.967-972
    • /
    • 2004
  • The role of transfer films formed during sliding of polymer composites against steel counterfaces was studied in terms of the tribological behaviors of composites. Four kinds of composites were included in this study: (1) unfilled PPS, (2) PPS+2%CuO, (3) PPS+2%CuO+5% carbon fiber (CF), and (4) PPS+2%CuO+15%Kevlar. The filler material CuO was in nanoscale particulate form and the reinforcing material was in the form of short fibers. The composites were prepared by compression molding at $310^{\circ}C$ and sliding tests were run in the pin-on-disk sliding configuration. The counterface was made of tool steel hardened to 55-60 HRC and finished to a surface roughness of 0.09-0.10 ${\mu}m$ Ra. Wear tests were run for 6 hrs at the sliding speed of 1 m/s and contact pressure of 0.65 MPa. Transfer films formed on the counterfaces during sliding were investigated using AFM and SEM. The results showed that as the transfer film became smooth and uniform, wear rate decreased. PPS+2%CuO+15%Kevlar composite showed the lowest steady state wear rate in this study and its transfer film showed the smoothest and the most uniform characteristics. The examination of worn surfaces of PPS+2%CuO composite using X-ray area scanning (dot mapping) showed back-transfer of steel counterface material to the polymer pin surface. This behavior is believed to strengthen the polymer pin surface during sliding thereby contributing to the decrease in wear rate.

  • PDF

THE UPDATED ORBITAL PERIOD OF LOW MASS X-ray BINARY 4U 1323-62

  • CHUANG, PO-SHENG;CHOU, YI;HU, CHIN-PING;YANG, TING-CHANG;SU, YI-HAO;LIAO, NAI-HUI;HSIEH, HUNG-EN;LIN, CHING-PING
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.585-586
    • /
    • 2015
  • 4U 1323-62, a low mass X-ray binary with an orbital period of 2.94 hr, exhibits periodic X-ray dips, which are due to absorption by the bulge of the outer accretion disk. The purpose of this study is to search for orbital period changes using archived X-ray data over a time span of 20 years. We present our preliminary results from analyzing light curves observed by RXTE, BeppoSAX, XMM-Newton and Suzaku. We used the method proposed by Hu et al. (2008) to estimate dip center time and adopted the Observed - Calculated method to measure changes in period. We obtained an orbital period of 2.941917(36) hr and a period derivative of $\dot{P}_{orb}/P_{orb}=(-9.9{\pm}3.5){\times}10^{-7}yr^{-1}$. The F-test result shows that the quadratic ephemeris is describes the evolution of the dip phases better than the linear ephemeris at a greater than 95% confidence level. More X-ray data collected from the early 80s will be included to further refine the orbital ephemeris.

Asan Medical Center Laboratory Information System (R) Information Communication System for Routine Hematology Using a Down-Sized Computer - (서울중앙병원 임상병리과 정보관리시스템(III))

  • 민원기;최윤미
    • Journal of Biomedical Engineering Research
    • /
    • v.15 no.3
    • /
    • pp.333-340
    • /
    • 1994
  • Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16 MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with two complete blood count analyzers (Sysmex WE-8000 and Coulter STKS) for unidirectional data transmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology.

  • PDF

Implementation of Security Plan from .NET Remoting Environment (닷넷 리모팅 환경에서의 보안 방안 구현)

  • Kim, Young-Sear
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.4
    • /
    • pp.256-261
    • /
    • 2009
  • While .NET and J2EE bisects recent distributed environment, .NET displays "Remoting" as a technology to call remote object. Remoting is frequently used as a protocol in OLTP's WEB program development in form of RPC that exchange data in XML form under HTTP environment. Purpose of this research is to draw problems when applying security to .NET remoting technology that is recently used in web programming, and to find effective application plan by implementing. The main discussion is following. First, network layer security should be replaced to application layer security for better performance and flexibility. Second, the serialization procedure that is repeated in both remoting and encryption module should take place once. Lastly, implementation of "Surrogate" and "Compress" will be discussed that enables to eliminate unnecessary data(table relations, keys, etc) that is used in dataset object of .NET in order to reduce the size of data. It is possible to achieve improvement in speed by two times through immediate implementation in these cases. In order for easier use, component based framework should be supplied hereafter.

  • PDF

Utilization of the Bombyx mori Hypothetical Protein 32 Promoter for Efficient Transgene Expression

  • Goo, Tae-Won;Kim, Sung-Wan;Kim, Seong-Ryul;Park, Seung-Won;Kang, Seok-Woo;Lee, Kwang-Gill;Kwon, O-Yu;Yun, Eun-Young
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • v.20 no.2
    • /
    • pp.107-114
    • /
    • 2010
  • For stable germline transformation, the promoter of Bombyx mori cytoplasmic actin gene (BmA3) has been used for ubiquitous expression of transgenes. So far, no strong promoter is available for ubiquitous expression in B. mori, excluding BmA3 promoter. To identify more powerful promoter than previously reported BmA3 promoter, we isolated 9 clones that show stronger signal compared to BmA3 by a dot blot hybridization. Among these 9 clones, we focused on one clone which has high amino acid homology (85%) with hypothetical protein 32 gene of Lonomia obliqua. This clone, named bHp32 (B. mori hypothetical protein 32) was ubiquitously expressed in all tissues and developmental stage of fifth instar B. mori larvae. As result of promoter assay using dual luciferase assay system, we found the highest transcription activity region (-1,200/+220) in the 5'-flanking region of bHp32 gene, which has 42-fold more intensive promoter activity than BmA3 promoter. Moreover, the bHp32 promoter was normally regulated in Bm5, Sf9, and S2 cells. Therefore, we suggest that bHp32 promoter may be used more powerful and effectively for transgene expression in various insects containing B. mori as a universal promoter.

A Study On The Painting Applying With Optical Art (옵아트 기법을 응용한 회화에 관한 연구)

  • Byun, Sung-Tae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.95-103
    • /
    • 2021
  • I began to produce a series of works based upon the plastic element as a visual transmission -such as points, lines, sides, volumes and cubics, movements with in time, and space- which appeared in the optical art, that emerged in the 1950s and the early 1960. My works, which portray the natural scenes such as mountains, trees, and flowers that are commonly seen around us, are completed by drawing, erasing, filling with many points and overlapping. My works also ignore the scenography. All artistic activities must be based upon humanistic values and ultimately need to work for human being. The work with application of opt art did not use the perspective, but diverse colors. The work with application of opt art did not use the perspective, but diverse colors. The work tried to express more diverse impression rather than the emotion from the familiar perspective. We hope, therefore, my works give pleasure and satisfaction to these who come to see them.

Design Of Minimized Wiring XOR gate based QCA Half Adder (배선을 최소화한 XOR 게이트 기반의 QCA 반가산기 설계)

  • Nam, Ji-hyun;Jeon, Jun-Cheol
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.10
    • /
    • pp.895-903
    • /
    • 2017
  • Quantum Cellular Automata(QCA) is one of the proposed techniques as an alternative solution to the fundamental limitations of CMOS. QCA has recently been extensively studied along with experimental results, and is attracting attention as a nano-scale size and low power consumption. Although the XOR gates proposed in the previous paper can be designed using the minimum area and the number of cells, there is a disadvantage that the number of added cells is increased due to the stability and the accuracy of the result. In this paper, we propose a gate that supplement for the drawbacks of existing XOR gates. The XOR gate of this paper reduces the number of cells by arranging AND gate and OR gate with square structure and propose a half-adder by adding two cells that serve as simple inverters using the proposed XOR gate. Also This paper use QCADesginer for input and result accuracy. Therefore, the proposed half-adder is composed of fewer cells and total area compared to the conventional half-adder, which is effective when used in a large circuit or when a half - adder is needed in a small area.

Threshold-based Pre-impact Fall Detection and its Validation Using the Real-world Elderly Dataset (임계값 기반 충격 전 낙상검출 및 실제 노인 데이터셋을 사용한 검증)

  • Dongkwon Kim;Seunghee Lee;Bummo Koo;Sumin Yang;Youngho Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.44 no.6
    • /
    • pp.384-391
    • /
    • 2023
  • Among the elderly, fatal injuries and deaths are significantly attributed to falls. Therefore, a pre-impact fall detection system is necessary for injury prevention. In this study, a robust threshold-based algorithm was proposed for pre-impact fall detection, reducing false positives in highly dynamic daily-living movements. The algorithm was validated using public datasets (KFall and FARSEEING) that include the real-world elderly fall. A 6-axis IMU sensor (Movella Dot, Movella, Netherlands) was attached to S2 of 20 healthy adults (aged 22.0±1.9years, height 164.9±5.9cm, weight 61.4±17.1kg) to measure 14 activities of daily living and 11 fall movements at a sampling frequency of 60Hz. A 5Hz low-pass filter was applied to the IMU data to remove high-frequency noise. Sum vector magnitude of acceleration and angular velocity, roll, pitch, and vertical velocity were extracted as feature vector. The proposed algorithm showed an accuracy 98.3%, a sensitivity 100%, a specificity 97.0%, and an average lead-time 311±99ms with our experimental data. When evaluated using the KFall public dataset, an accuracy in adult data improved to 99.5% compared to recent studies, and for the elderly data, a specificity of 100% was achieved. When evaluated using FARSEEING real-world elderly fall data without separate segmentation, it showed a sensitivity of 71.4% (5/7).

Evaluation of the Shield Performance of Lead and Tungsten Based Radiation Shields (납과 텅스텐 기반 차폐체의 성능 비교 평가)

  • Jeong-Hwan Park;Hyeon-Seong Lee;Eun-Seo Lee;Hyo-Jeong Han;Yun-Hee Heo;Jae-Ho Choi
    • Journal of radiological science and technology
    • /
    • v.46 no.6
    • /
    • pp.519-526
    • /
    • 2023
  • This study was intended to evaluate the shielding rate of radiation shields manufactured using 3D printers that have recently been used in various fields by comparing them with existing shields made of lead, and to find out their applicability through experiments. A 3D printer shield made of tungsten filament 1 mm, 2 mm, 4 mm shield, RNS-TX (nanotungsten) 1.1 mm, lead 0.2 mmPb, and 1mmPb were exposed to 99mTc, 18F, and 201TI for 15, 30, 45 minutes, and 60 minutes after measuring cumulative dose three times. Based on this, the shielding rate of each shield was calculated based on the dose in the absence of the shield. In addition, 99mTc, 18F, and 201TI were located 100 cm away from the phantom in which the OSLD nano Dot device was inserted, and if there was no shield for 60 minutes, the dose of thyroid was measured using 1.0 mm of lead shield, 1.1 mm of RNS-TX shield, and 2 mm of tungsten shield made by 3D printer. The use of shields during radiation shielding emitted from open radiation sources all resulted in a reduction in dose. The radiation dose emitted from the radionuclides under the experiment was all reduced when the shield was used. This study has been confirmed that tungsten is a material that can replace lead due to its excellent performance and efficiency as shield, and that it even shows the possibility of manufacturing a customized shield using 3D printer.