• 제목/요약/키워드: S&P 잡음

검색결과 153건 처리시간 0.022초

내측기어 성형용 사출성형 금형구조의 개발 (Development of the injection mold structure for internal gears)

  • 권윤숙;정영득
    • 동력기계공학회지
    • /
    • 제12권6호
    • /
    • pp.78-82
    • /
    • 2008
  • Plastic gears are more and more widely used in many industrial machine elements. Plastic gear has higher properties such as light weight, wear resistance, and vibration absorbing ability than metallic gears. But, in case of using an inaccurate plastic gear, its tooth breakage happen and fatigue life is shortened due to increase of applying load and temperature rising on the tooth flank. Inaccuracy of plastic gears such as pitch circle roundness and tooth profile generates vibration and noise. In this study, an internal plastic gears which is molded by a new injection mold structure are developed. The new mold structure is called the HR3P(hot runner type 3plate mold) that has an improved runner system in order to have good filling balance. As a result from this study, an internal gear with very accurate roundness was developed by using design of experiment.

  • PDF

한국인 정신분열병 환자의 안구추적운동 이상과 Dystrobrevin Binding Protein 1(DTNBP1) 유전자의 SNP A와 P1763 다형성의 연합에 대한 연구 (Relationship between SNP A and P1763 Polymorphisms on Dystrobrevin Binding Protein 1(DTNBP1) Gene and Smooth Pursuit Eye Movement(SPEM) Abnormality in Korean Schizophrenic Patients)

  • 이창희;박병래;김령효;김동현;조숙현;박진수;김임렬;이인상;서한길;변기욱;김봉조;한규희;김기훈;신태민;신형두;우성일
    • 생물정신의학
    • /
    • 제13권4호
    • /
    • pp.279-288
    • /
    • 2006
  • 목 적: 정신분열병 환자의 안구추적운동 이상은 유력한 생물학적인 지표이나 유전자적인 원인에 대한 연구가 활발히 진행되지 못하였다. 최근 여러 연구들에서 dystrobrevin binding protein 1(DTNBP1, dysbindin)이 정신분열병의 원인 유전자의 후보 유전자로서 시사되었으나 정신분열병 환자의 안구운동 이상의 원인으로 작용할 것인지에 대한 연구는 거의 없었다. 본 연구의 목적은 DTNBP1 유전자상에 존재한 비교적 인접한 두개의 단염기 다형성들인 SNP A와 P1763이 정신분열병 환자의 안구추적운동 이상의 유전자적인 원인으로 작용할 것인지를 알아보고자 시행되었다. 방 법: 대상군은 217명의 입원한 만성 정신분열병 환자들이며 안구운동(SPEM)을 측정하였고, 신호/잡음의 자연대수 값(Ln S/N ratio)을 구하여 안구운동이 우수한 군과 열등한 군으로 구분하였다. 이후 대상군의 혈액에서 추출한 DNA로부터 DTNBP1 유전자상의 단 염기 다형성들인 SNP A와 P1763를 분석하여 유전자형과 대립인자형을 알아낸 후, 안구운동 이상 유무에 따른 두 군사이의 분포의 차이를 조사하였다. 결 과: 정신분열병 환자들 중 안구운동이 우수한 군의 신호/잡음의 자연대수 값(Ln S/N ratio)의 평균과 표준편차는 $4.39{\pm}0.33$이었고, 안구운동이 열등한 군의 신호/잡음의 자연 대수 값(Ln S/N ratio)의 평균과 표준편차는 $3.17{\pm}0.71$이었다. 두 군 사이에 나이나 성별비율의 차이는 통계적으로 의미가 없었다. SNP A와 P1763의 유전자형과 대립인자형의 분포의 차이는 안구운동 이상 유무에 따라 구분한 두군 사이에 나타나지 않았다. 결 론: DTNBP1 유전자상에 존재한 SNP A와 P1763은 정신분열병 환자의 안구추적운동 이상의 유전자적인 원인으로 작용한다는 증거를 얻지 못하였다.

  • PDF

한국의 eLoran FOC 구현을 위한 전략에 관한 연구

  • 국승기;김정록;박혜리
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2013년도 추계학술대회
    • /
    • pp.366-369
    • /
    • 2013
  • 위치, 항법 및 시각정보가 육상, 해상, 항공 등 지구상 거의 모든 공간에서 다양한 목적으로 활용되고 있는 위성항법시스템(GNSS, Global Navigation Satelite System)은 그 중요성이 더욱 높아지고 있으며 미국이 제공해 주는 GPS의 고의잡음(SA)제거 및 성능 향상을 통하여 GNSS를 이용한 응용분야의 발전은 더욱 확대되고 있는 실정이다. 이러한 위성항법시스템의 P.N.T(Position, Navigation and Timing) 서비스 기능을 사회의 전박적인 주요 인프라 시설에 기초적인 원리의 정확성을 더하고 지속성과 무결함성을 제공할 수 있기 때문에 신뢰성을 가지고 여러분야에 활용되고 있으나 지상에서 약20,200km 고도에 위치한 인공위성에서 미약한 신호를 송신함으로써 GNSS 수신기가 의도적이든 비의도적이든 동일한 주파수 밴드의 신호에 영향을 받을 경우 정상적인 역할을 할 수 없다. 우리나라의 경우 P.N.T 서비스 기반 자체가 GPS에 전적으로 의존하고 있으며 유사시 이를 대체할 항법 시스템을 별도로 갖추고 있지 않고 있어 미국의 고의적인 GPS 서비스의 중단이나 주변국가의 방해전파 송신으로 인한 GPS 신호 중단사태가 발생할 경우에는 우리나라 국가 주요 인프라에 치명적인 피해를 입힐 수 있기 때문에 대체항법을 시스템을 구축하여 독자적인 P.N.T 서비스를 제공할 수 있는 시스템 구축이 국가적인 차원에서 절실하게 필요하다.

  • PDF

Self Seeded F-P LD를 이용한 WDM-PON에서의 파장 가변 레이저 소스 구현 (Implementation of tunable laser source for WDM-PON using an self seeded F-P LD)

  • 오영국;황지홍;이혁재;이창희
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2012년도 추계학술대회
    • /
    • pp.439-441
    • /
    • 2012
  • 본 논문에서는 Self-Seeding 방식의 F-P LD를 이용하여 WDM-PON에서의 새로운 파장 가변 광원 구조에 대하여 제안한다. 제안된 광원은 매우 간단한 구조를 갖고도 약 20 nm 정도의 큰 파장 대역을 갖는 장점을 가졌다. 상대적 잡음 밀도(RIN)은 약 -124dB/Hz로 나타났으며, 외부 변조기를 통해 외부 변조한 결과 10Gb/s 신호에 대한 변조 가능성을 확인 할 수 있었다.

  • PDF

자동노출제어를 적용한 흉부 방사선 검사 시 인체 이식형 의료기기가 선량과 화질에 미치는 영향 (Effect of Human Implantable Medical Devices on Dose and Image Quality during Chest Radiography using Automatic Exposure Control)

  • 이강민
    • 한국방사선학회논문지
    • /
    • 제18권3호
    • /
    • pp.257-265
    • /
    • 2024
  • 본 연구는 자동노출제어 흉부 방사선 검사 시 신체 기능 일부를 대체 보조하거나 의약품 등을 주입하는 인체 이식형 의료기기가 흉부 영상의 선량과 화질에 영향을 미치는지 알아보고자 하였다. 제조회사와 모델이 다른 3대의 디지털 X선 발생장치와 인체모형 팬텀을 사용하여 흉부 검사와 동일한 방법으로 위치잡이를 선정 후 선행 연구에서 선량의 변화가 관찰된 인공심장박동기(Pacemaker), 심장 재동기화 치료기(CRT), 케모포트(Chemoport) 3개의 HIMD(Human Implantable Medical Device)를 상단 이온전리조센서에 부착한 후 Monte Carlo 방법론 기반의 프로그램 PCXMC 2.0을 사용하여 실험에서 도출된 DAP(Dose Area Product) 값을 입력하여 유효선량을 측정하였다. 또한 흉부 영상의 화질 평가를 하기 위해 가슴 부위에 관심 영역 3곳과 잡음영역 1곳을 설정하고 신호대잡음비(SNR; Signal to Noise Ratio), 대조도대잡음비(CNR; Contrast to Noise Ratio)를 측정하였다. 연구 결과는 유효선량의 유의미한 차이를 보여주었으며 AEC 적용과 미적용 그룹을 비교하였을 때 Pacemaker와 CRT는 유의한 차이가 있었다. (p<0.05) AEC 적용 시 Pacemaker에서 37%, CRT에서 52% 유효선량이 증가하였다. Chemoport는 유효선량의 10% 차이는 있었지만, 유의미한 차이를 보이지 않았다. (p>0.05) 영상 품질 평가에서는 모든 HIMD 삽입과 AEC 적용 유무에 따른 SNR, CNR의 유의미한 차이를 보이지 않았다. (p>0.05) 최종 결론은 AEC 적용 후 HIMD가 삽입된 환자의 흉부 X-ray 검사 시 유효선량이 증가하였으며 AEC 적용 유무에 따른 흉부 영상의 품질 차이는 없음을 알 수 있었다. 이는 HIMD가 삽입된 환자의 흉부 검사 시 AEC 미사용이 환자의 선량을 낮추는 타당성을 확인한 것이며 과피폭을 주의하고 피폭 저감화를 위한 다양한 방법을 모색하여야 한다.

머리뼈 전-후 축 방향검사 시 Tube 방향설정에 따른 표면선량과 영상분석에 관한 연구 (A Study on the Comparative Analysis of Images and Doses According to Tube Orientation During Anterior-Posterior Axial Projection Examination of the Skull)

  • 정성훈;유제현;임청환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권4호
    • /
    • pp.301-306
    • /
    • 2021
  • The skull has peripheral organs such as the crystalline lens and thyroid gland, which are highly radiosensitive, but the examination is performed without considering the uneven dose distribution due to the heel effect at the time of the current Skull Town's examination. However, no studies have been conducted on the exposure dose of surrounding organ tissues due to the difference in image density due to the heel effect and the non-uniformity of the dose. Using the cathode (-) and anode (+) set on the Tube to measure the scattered radiation along the Tube direction as a guide, change 30° and 37° in the cathode direction and 30° and 37° in the anode direction. It was given and investigated 5 times to obtain scattered radiation. image measurements were SNR, PSNR, RMSE, and MAE. Measurement results Measurement results of surrounding organ doses when the Tube direction was 30° and 37° The dose was low when the direction was cathodic in all organs (p<0.000). Both cathodes were higher in the image measurements(p<0.04). Continuous research may be needed for diagnostically valuable imaging and minimization of patient exposure dose.

잔향시간이 양이를 사용한 한국어 단음절 인지에 미치는 영향 (Effects of reverberation time on binaural Korean monosyllabic word recognition in normal hearing subjects)

  • 임덕환
    • 한국음향학회지
    • /
    • 제40권6호
    • /
    • pp.678-682
    • /
    • 2021
  • 실내에서 소음과 함께 존재하는 잔향시간은 어음인지에 영향을 미친다. 그 정도는 청취 조건이나 사용된 언어의 특성에 따라서 그 내용이 다를 수 있다. 본 연구에서는 양이 청취 조건에서 잔향시간이 정상 성인 10인의 표준화 된 한국어 단음절 변별력에 미치는 효과를 확인하고자 하였다. 양이 청취효과는 diotic(양이 소음간 동일 위상) 조건과 dichotic(양이 소음 간 위상차 존재, π) 조건에서 신호대잡음비를 0 dB로 고정하였다(55 dB HL). 잔향시간 효과를 관찰할 수 있는 3.4 s에서 대상의 단음절 변별력인 Word Recognition Score(WRS)점수를 분석하였다. 결과에서 dichotic인 경우에는 단측 청취 결과와 비교하여 유의한 변별력 개선이 보였고(p < 0.05), diotic 조건에서는 단측청취와 유의한 차이를 관찰할 수 없었다. 이러한 결과는 잔향시간을 고려한 여러 소음 음향 환경 분석에 참고가 될 수 있을 것으로 판단된다.

뇌 수막종 및 낭종에서 자기공명영상 펄스 시퀀스 변화에 따른 신호대잡음비의 통계적 접근 (Statistical Approach of Measurement of Signal to Noise Ratio in According to Change Pulse Sequence on Brain MRI Meningioma and Cyst Images)

  • 이을규;최관우;정회원;장서구;김기원;손순룡;민정환;손진현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권3호
    • /
    • pp.345-352
    • /
    • 2016
  • 본 연구는 뇌 자기공명영상에서 질환관심영역(ROI)을 설정하여 신호대잡음비(SNR)를 펄스 시퀀스 별로 분석하여 MRI CAD 개발에 필요한 기초자료를 활용하고자 하는 것이 본 연구의 목적이다. 연구대상은 2005년 1월부터 2015년 12월까지 서울소재 대학병원에서 뇌 조영자기공명영상(Brain MRI Contrast Enhancement)을 검사한 환자 117명이다. 측정이 용이한 질환 2종류 수막종(Meningioma), 낭종(Cyst)을 측정대상으로 하였고, 측정방법은 Image J 프로그램을 사용하였다. 뇌질환의 SNR값을 측정하여 SPSS Statistics21 통계프로그램으로 ANOVA 분석을 하였으며 p < 0.05에서 유의한 것으로 판단하였다. 표본의 인구사회학적 특성, 시퀀스별 SNR의 평균값, 95% 신뢰 구간 값, SNR 평균차이 값 등을 분석하였다. 각 질환의 시퀀스별 분석결과는 Meningioma: T1CE > T2 > T1, FLAIR (p<0.05); Cyst: T2 > T1, T1CE > FLAIR (p < 0.05)였다. SNR 수치로 시퀀스들의 특징을 조합하여 질환의 특성을 파악할 수 있어 향후 자기공명영상검사의 정확성과 편의성을 제공하고, 판독보조진단 프로그램 개발의 기초자료로 활용될 수 있을 것으로 기대된다.

유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가 (Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography)

  • 정홍량
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.435-441
    • /
    • 2021
  • The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 cm2). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 cm2. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver's method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver's method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver's method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver's method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver's method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver's method. This was found to be statistically significant(p<0.000).

GPS 재밍 기법과 항재밍 GPS 기술 (GPS Jamming Techniques and Anti-Jamming GPS Technologies)

  • 조인화;김형석;박태용
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.573-575
    • /
    • 2015
  • 위성을 이용한 측위 장치인 GPS는 위치를 구하는 용도 뿐 아니라 항법, 시간 정보 획득 등 다양한 분야에 활용되며, 특히 미사일 등 정밀 유도무기의 정밀도를 향상시키는데 중요한 역할을 하고 있다. 그러나 민간에 공개된 상용 코드(C/A 코드)를 사용하는 GPS는 대전자전 기능이 없다. 그러므로, 다양한 재밍 기법에 취약하고, 암호화된 군용 코드(P 코드)의 경우에도 인접한 곳에서 잡음 재밍 공격을 가할 경우 취약할 수 있다. 본 논문에서는 GPS의 재밍 기법과 과거 북한의 GPS 재밍 사례에 대해 조사하고, 항재밍 GPS에 적용되는 기술에 대해 설명하였다.

  • PDF