• Title/Summary/Keyword: Rx

Search Result 394, Processing Time 0.02 seconds

RFID Antenna Module with High Isolation Characteristic between Tx and Rx (송.수신 격리 특성을 개선한 RFID 안테나 모듈)

  • Park, Dong-Hoon;Kim, Gui-Sung;Kim, Hyung-Eun;Park, Hye-Mi;Wei, Kai;Lim, Eun-Cheon;Lee, Moon-Que
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.370-375
    • /
    • 2011
  • In this paper, we propose an antenna module with high isolation between Tx and Rx in RFID reader module. The proposed module consists of a quadrafilar antenna and a directional coupler with a switchable dummy load to improve the directivity. The proposed module achieves the isolation higher than 20 dB between Tx and Rx. To show the validity of the proposed scheme, we have performed the measurement of tagging range and multi-tagging ability. The experiment results show that the detecting range and multi-tagging ability are enhanced by 81% and 200%, respectively.

Implementation of Inductive Wireless Power Transfer System based on LLC Converter without Wireless Communication between Tx and Rx (Tx-Rx간 무선통신이 필요 없는 LLC 컨버터 기반 유도형 무선전력전송 시스템 구현)

  • Kim, Moon-Young;Choi, Shin-Wook;Kang, Jeong-il;Han, Jonghee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.24 no.5
    • /
    • pp.311-318
    • /
    • 2019
  • In general wireless power transfer systems (WPTSs), power transfer is controlled by the wireless communication between a transmitter (Tx) and a receiver (Rx). However, WPTS is difficult to apply in electronic products that do not have batteries, such as TVs. A WPTS with resonators based on a transformer of LLC series resonant converter is proposed in this study to eliminate wireless communication units between a Tx and an Rx. The proposed system operates at the boundary of the resonance frequency, and the required power can be stably supplied to authorized devices even though some misalignment occurs. Moreover, standby power standards for the electronic product can be satisfied.

Magnetic Resonant Wireless Power Transfer with L-Shape Arranged Resonators for Laptop Computer

  • Choi, Jung Han;Kang, Seok Hyon;Jung, Chang Won
    • Journal of electromagnetic engineering and science
    • /
    • v.17 no.3
    • /
    • pp.126-132
    • /
    • 2017
  • In this study, we designed, measured, and analyzed a rearranged L-shape magnetic resonance coupling wireless power transfer (MR-WPT) system for practical applications with laptops. The typical four resonator MR-WPT (Tx part: source loop and Tx coil; Rx part: Rx coil and load loop) is difficult to apply to small-sized stationary and mobile applications, such as laptop computers, tablet-PCs, and smartphones, owing to the large volume of the Rx part and the spatial restrictions of the Tx and Rx coils. Therefore, an L-shape structure, which is the orthogonal arrangement of the Tx and Rx parts, is proposed for indoor environment applications, such as at an L-shaped wall or desk. The relatively large Tx part and Rx coil can be installed in the wall and the desk, respectively, while the load loop is embedded in the small stationary or mobile devices. The transfer efficiency (TE) of the proposed system was measured according to the transfer distance (TD) and the misaligned locations of the load loop. In addition, we measured the TE in the active/non-active state and monitor-open/closed state of the laptop computer. The overall highest TE of the L-shape MR-WPT was 61.43% at 45 cm TD, and the TE decreased to 27.9% in the active and monitor-open state of the laptop computer. The conductive ground plane has a much higher impact on the performance when compared to the impact of the active/non-active states. We verified the characteristics and practical benefits of the proposed L-shape MR-WPT compared to the typical MR-WPT for applications to L-shaped corners.

Near-Field Rx-Measurement for Active Phased Array of Digital Radar Using Calibration Path (보정 경로를 활용한 디지털 레이더의 능동 위상 배열 근접전계 수신시험)

  • Yu, Je-Woo;Chae, Heeduck;Park, Jongkuk;Lim, Jae-Hwan;Kim, Duckhwan;Jin, Hyoung-Seog;Kim, Han-Saeng
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.6
    • /
    • pp.504-511
    • /
    • 2016
  • In this paper, the method is proposed that the equivalent result can be obtained by compensating the variation of gain and phase in the comparison with the result of near-field measurement which is obtained in the steady state, although the gain and phase variation of rx-channels occurred in the near-field rx-measurement of digital active phased array antenna. The proposed concept has the time section for monitoring the state of the rx-channels through the calibration path in the measurement timeline, and is the method for compensating the variation of state. For validating the proposed method, the fabricated X-band digital active phased array antenna and the planar near-field measurement facility is utilized. The proposed method is validated in the comparison with the compensated pattern which the unstable state of rx-channels is calibrated and the reference pattern obtained under the steady state of the rx-channels.

Improved Degree of Freedom of Magnetic Induction Wireless Charging Coil Using Proposed Double Coil (이중코일을 이용한 자기유도 무선충전 코일의 자유도 개선)

  • Choi, Bo-Hee;Nam, Yong-Hyun;Chung, Habong;Lee, Jeong-Hae
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.12
    • /
    • pp.907-914
    • /
    • 2018
  • Wireless charging has been actively researched and popularized owing to the potential convenience of being able to charge electronic devices without wires for users. However, the receiver on the wireless charging pad is not charged when the center of the receiver is misaligned; thus, the center of the receiver must be adjusted well. This misalignment may greatly reduce the convenience of wireless charging. To overcome this limitation of wireless charging, a coil is designed to improve the positional freedom of the receiver. The positional freedom of the Rx coil is improved when the outer diameter of Tx coil is larger than when Rx and Tx coils are almost the same size. When the Tx coil has a larger outer diameter than that of the Rx coil, the efficiency at the center is somewhat lowered, but the efficiency is improved compared to when the center is out of order. In this paper, a double coil structure having an outer and an inner coil is proposed. The double coil structure further improves the efficiency, compared with one coil with the same outer size. The simulation and measurement results demonstrated that the tendency was consistent, and it was verified that the degree of freedom of the Rx coil is improved by adding the inner coil, while the size of the outer coil was the same. The measurement shows that the transmission efficiency of the conventional Tx coil is 37 %, the larger outer diameter coil is 45 %, and double coil is 47 % when the distance of the Tx/Rx coil is 3 mm, the misalignment is 15 mm and current flowing in the Rx coil is 1 A at an operating frequency of 105 to 210 kHz.

Service Integrated Digital PBX / RX (사설 및 농어촌 통합 디지탈 교환기)

  • Jeong Rhul Lee
    • Information and Communications Magazine
    • /
    • v.9 no.1
    • /
    • pp.37-42
    • /
    • 1992
  • This paper presents a multi-purpose digital exchange which can be used as a private branch exchange(PBX) or a rural exchange(RX) or an exchange for the private special network. This new idea provides various features, reduced cost of installation and operation, easy expansion, replacement and relocation or reuse for another purpose at other locations.

  • PDF

Performance Improvement of IP Handover by Data Link Trigger (데이터링크 트리거에 의한 IP 핸드오버 성능 개선)

  • Ki, Jang-Geun;Lee, Kyu-Tae
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.55-60
    • /
    • 2016
  • In the traditional wireless LAN model, scan procedure to search a new AP starts when the predefined number of Rx failure of beacon frames are occurred. In this case, lots of data packet loss occur during MN's handover because loss of the relatively longer data packet starts before the small-sized beacon loss. Newly developed scanning mechanism in this paper has the beacon counter that increases when the Rx power level of beacon frame is less than the threshold and the previous rx power level. New scan procedure starts when the counter exceeds the predefined number. Beacon Rx power threshold is verified and performance of the new WLAN model is evaluated under UDP and TCP traffic environment.

Tx-Leakage Signal Blocking System in RFID System (단일 안테나를 사용하는 RFID에서의 Phase Shifter를 이용한 TX Leakage 제거 방식)

  • Jeon, Bu-Won;Bae, Jae-Hyun;Roh, Hyoung-Hwan;Joung, Myoung-Sub;Park, Jun-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.8
    • /
    • pp.862-865
    • /
    • 2007
  • Rx and Tx signal use same band in RFID. Then RFID system is not used duplexer and used coupler. RFID system have problem about Rx part to Tx leakage signal because that Rx signal port is Tx signal port's Isolation port. We proposal using phase shifter Tx leakage signal decrease than other RFID system. It is same signal Tx signal port's coupling port and isolation port signal except amplitude and phase. So if make coupling signal and isolation signal is in all same signal. We cancel Tx leakage signal used coupling port. And verification about ADS2006.

Merging the old with the new: a cybermedicine marriage for oncology interactions with traditional herbal therapies and complementary medicines

  • Yap, Kevin Yi-Lwern;Lim, Ken Juin
    • CELLMED
    • /
    • v.2 no.2
    • /
    • pp.18.1-18.16
    • /
    • 2012
  • An oncology-specific database called OncoRx (http://bit.ly/cancerRx) was previously set up in cyberspace to aid clinicians in identifying interactions of anticancer drugs (ACDs) and chemotherapy regimens with traditional Chinese medicines (TCMs) and complementary and alternative medicines (CAMs). Since then, users have requested the drug-CAM interactions (DCIs) of 5 specific CAMs (cranberry, melatonin, co-enzyme Q10, huachansu, reishi mushroom) to be updated in the database. Pharmacokinetic properties (metabolism, enzyme induction/inhibition, elimination), TCM properties and DCIs of each CAM were collated with 117 ACDs using 9 hardcopy compendia and online databases as resources. Additionally, individual ACDs and CAMs were used as keywords for PubMed searches in combination with the terms 'anticancer drugs', 'drug interactions', 'herb-drug/drug-herb interactions', 'pharmacokinetic interactions' and 'pharmacodynamic interactions'. DCI parameters consisted of interaction effects, evidence summaries, proposed management plans and alternative non-interacting CAMs, together with relevant citations and update dates of the DCIs. OncoRx is also used as a case to introduce the "Four Pharmaco-cybernetic Maxims" of quality, quantity, relationship and manner to developers of digital healthcare tools. Its role in Hayne's "5S" hierarchy of research evidence is also presented. OncoRx is meant to complement existing DCI resources for clinicians and alternative medicine practitioners as an additional drug information resource that provides evidence-based DCI information for ACD-CAM interactions.