Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in a Reverberation Chamber (수음실 잔향 시간변화에 따른 바닥충격음레벨 특성 - 잔향실을 중심으로 -)

  • Jeong, Jeong Ho;Kim, Jeong Uk;Jeong, Jae Gun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.3
    • /
    • pp.274-281
    • /
    • 2013
  • Field measurement method of heavy/soft impact sound pressure level which is regulated in JIS and ISO has been using in Korea, Japan and Canada. It is reported that heavy/soft impact sound pressure level was varied by the sound field condition of receiving room such as sound absorption power and room volume. In this study, it is checked that heavy/soft impact sound pressure level was affected by the receiving sound field condition. Rubber ball and bang machine sound pressure level was measured in the vertically connected reverberation chamber. In oder to check the effect of receiving sound field on heavy/soft impact sound pressure, sound absorption power was changed with polyester sound absorption blankets with air space and glass wool. The reverberation time at 1 kHz band was changed from 10 s to 0.2 s by sound absorption material. Rubber ball sound pressure level measured without sound absorption material was 58 dB in $L_{i,Fmax,AW}$, but the level was 46 dB with sound absorption treatment. From this result, it is confirmed that sound field correction method is needed in the heavy/soft impact sound pressure level measurement method using bang machine and rubber ball.

The Thermal Degradation Mechanism of Polymethyl Methacrylate Blend (Polymethyl Methacrylate Blend의 열화에 따른 분해기구 해석에 관한 연구)

  • Kim, Dong-Keun;Moon, Myeong-Ho;Seul, Soo-Duk;Sohn, Jin-Eon
    • Elastomers and Composites
    • /
    • v.23 no.2
    • /
    • pp.125-133
    • /
    • 1988
  • The thermal degradation of polymethyl methacrylate(PMMA) blend namely polymethyl methacrylate-polycarbonate(PMMA-PC) blend and polymethyl methacrylate-polystyrene(PMMA-PS) blend were carried out by isothermal method under air at several heating temperature from 220 to $270^{\circ}C$. Molecular weight changes during the thermal decomposition were monitored by means of the viscosity average molecular weight($\bar{M}v$). The viscosity average molecular weight was determined by Gel Permeation Chromatography(GPC). The dominant process in the degradation of PMMA-PC and PMMA-PS blend were main chain scission randomly due to weak links that may be distributed along the polymer backbone and the initial rate which the bonds are broken is not sustained. The infra-red spectra of degraded PMMA-PS blend show that the presence of aromatic ketone band at $1685cm^{-1}$. However, the infra-red spectra of degraded PMMA-PC blend show that the presence of hydroperoxide band at $3450cm^{-1}$. Thus indicating that the weak links are attacked by oxygen from the air and produce hydroperoxide or ketone. The activation energies of PMMA-PC blend and PMMA-PS blend were 18.2 and 17.9 Kcal/mol, respectively.

  • PDF

Comparative Analysis of Muscle Activities for Upper Extremity During Resistance Exercises Using Variable and Elastic Loads (가변부하 및 탄성부하를 이용한 저항성 기구 운동 시 발현되는 상지근육의 근 활동치 비교분석)

  • Lim, Young-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.2
    • /
    • pp.37-44
    • /
    • 2006
  • The purposes of this study were to analyze and compare EMG activities of the pectoralis major, biceps brachii, triceps brachii, and brachioradialis muscles during biceps curls using a VRT device and an elastic tubing. Fifteen male college students were recruited as subjects and they performed 10-RM and 20-RM biceps curls. For each load and device condition, the mean and peak normalized EMG levels during different phases of a biceps curl were computed. For each load and phase, paired t-test (p.05) was used to find the significant difference between two devices. ANOVA with repeated measures was also used to find the significant difference among phases in terms of EMG values for each muscle. For each load and device condition, the peak and mean EMG levels during different phases of a biceps curl were computed The significant differences between devices were found in biceps brachii for EA, MD, LD phases, and triceps brachii muscles for all phases, respectively. However, no differences were found among phases for any muscle. This indicated that elastic band could have a similar characteristics of VRT. High antagonistic muscle activity as a function of injury prevention which found particularly in VRT device may suggest that elastic tubing can be a safer training device than VRT. This also imply that elastic tubing could be very effective as a home exercise tool for rehabilitation patients and elderly people.

Investigations of Accelerated Aged Polymeric Insulators Using Partial Discharge Signal Measurement and Analysis

  • Mekala, K.;Chandrasekar, S.;Ravindran, R. Samson
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.299-307
    • /
    • 2015
  • Reduction in pollution performance of polymeric insulators, aged due to water absorption stress and thermal stress, is a major threat to the reliable operation of power transmission and distribution system. Formation of partial discharges on the surface of wet polluted insulator plays a major role in determining the life time and pollution performance of outdoor polymeric insulators. However, reports on partial discharge characteristics of water absorption stress aged and thermal aged polymeric insulators are scanty. This paper discusses the pollution performance characteristics of accelerated aged polymeric insulators using the advanced ultra wide band PD signal measurement and analysis. Laboratory experiments on accelerated aged polymeric insulators were carried out as per IEC 60507 under AC voltage, at different humidity and contamination levels using NaCl as a contaminant. PRPD pattern and Time-Frequency map analysis of PD signals were carried out. From the results, it can be speculated that PD analysis is a well suited technique to understand the pollution performance of aged polymeric insulators.

Simplified method on measurement and evaluation of floor impact sound using impact ball (임팩트 볼에 의한 바닥충격음 측정 및 평가 간편법)

  • Kim, Yong-Hee;Lee, Sin-Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.631-635
    • /
    • 2006
  • In this study, simplified methods on measurement and evaluation of heavy-wight impact sound was proposed due to provide easy quality control method to construction engineers. The simplified methods include using of rubber impact ball instead of bang machine, reduced number of measuring and impact positions which is prescribed as over 4 points, using of hand-held sound level meter as a frequency analyser and prediction equation for $L_{i.Fmax.AW}$, single number rating, using $L_{Amax}$, and $L_{Lmax}$ at each frequency band. The results showed that a method of boundary driving and boundary measuring is the most similar to the current rating method.

  • PDF

A Study on the Contact Force and Temperature Distribution of Lip Seals (립실의 접촉력 및 온도분포 해석에 관한 연구)

  • 김청균;전인기;김종억
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.6
    • /
    • pp.1559-1566
    • /
    • 1994
  • Using the finite element method, the contact force, contact band width and temperature distribution of lip seals analyzed for the interference including some nonlinearities such as material nonlinearity, geometrical nonlinearity and nonlinear contact boundary condition. The calculated results showed that the contact stress concentrated on the contact zone between the garter spring and the rubber toward the flex side, the contact edge of lip seals. The high contact forces due to the increased interference separate the sealing gap between the lip edge and the rotating shaft. This may lead to leak the sealed oil.

Prediction of Sound Radiation Power from Coupled Structures Uusing SEA (SEA법에 의한 결합구조물의 음향방사파워 예측)

  • 오재응;이명렬
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.13 no.1
    • /
    • pp.20-28
    • /
    • 1989
  • SEA(Statistical Energy Analysis) method has been applied to predict the sound radiation power from vibrating machinery. In this study, sound radiation power was predicted from coupled structures by transmission of vibration, which composed of two plates welded into an L shape. The predicted sound radiation power is in agreement within 2 or 3 dB on octave band comparing with values obtained from direct measurements. Also, in order to prove the validity of this method in changes of sound radiation power associated with modifications to structures, rubber pad was stuck on a plate. The results agree approximately within 3 or 5 dB. And SEA method is valuable for the optimal design to reduce the noise. Additionally, this paper suggests that the logarithmic decrement method is valid as the one for finding the loss factor.

Electromagnetic Properties of Siver Coated Iron based Alloy Powders Prepared by Chemical Reduction Method

  • Lee, Byoung-Yoon;Lee, Jae-Wook;Yun, Yeo-Chun;Jeong, In-Bum;Moon, Joo-Ho
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1213-1214
    • /
    • 2006
  • The synthesis of silver coated iron base alloy (Sendust : Fe-Si-Al) powder having the both effects of shielding and suppressing of electromagnetic wave was studied. Depending on thickness of silver coating layer, the electromagnetic properties of the dispersed particles complexed with organic binder were examined. It is proposed that the silver coated sendust flake powders with controlled electrical properties and thickness can be used as thin microwave absorbers in quasi-microwave frequency band.

  • PDF

A Study of the Effects of Wearing Gloves on Grip Strength and Safety (장갑 착용이 악력과 안전에 미치는 영향에 관한 연구)

  • Jung, Hwa-Shik;Koo, Dong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.4
    • /
    • pp.13-23
    • /
    • 2006
  • Grip strength provides a quick and objective index of the functional integrity of the upper extremities. It is widely used as an assessment measure in physical and rehabilitation medicine. In this study, maximum voluntary grip strength of 20 college students wearing 5 different gloves were measured using Jamar hand dynamometer. The results show that maximum voluntary grip strength was generally reduced when wearing gloves as compared to bare-handed. More specifically, the grip strength was highest when wearing PVC coated glove or bare-handed and getting lowered as wrist band, rubber, leather, and cotton glove in these order. Depending on the measuring posture of grip strength, shoulder height with arm extended forward was higher than the elbow was flexed 90 degree. Moreover, subjects' demographic factors and hand dimensions were not closely related to the grip strength. It is thus recommended that the proper glove should be provided to reduce the negative consequences including dropping a tool, poorer control of a tool. lower quality work, and increased muscle fatigue and in turn to increase the user safety and satisfaction.

Microwave Absorbing Properties of M-type Barium Ferrites with BaTi0.5Co0.5Fe11O19 Composition in Ka-band Frequencies (BaTi0.5Co0.5Fe11O19 조성을 갖는 M형 바륨 페라이트의 Ka-밴드 전파흡수특성)

  • Kim, Yong-Jin;Kim, Sung-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.19 no.6
    • /
    • pp.203-208
    • /
    • 2009
  • Magnetic and Ka-band absorbing properties have been investigated in Ti-Co substituted M-type barium hexaferrites with $BaTi_{0.5}Co_{0.5}Fe_{11}O_{19}$ composition. The ferrite powders were prepared by conventional ceramic processing technique and used as absorbent fillers in ferrite-rubber composites. The magnetic properties were measured by vibrating sample magnetometer. The complex permeability and dielectric constant were measured by using the WR-28 rectangular waveguide and network analyzer in the frequency range 26.5~40 GHz. For the Ti-Co substituted M-hexaferrites, the ferromagnetic resonance is observed at Ka-band (29.4 GHz). The matching frequency and matching thickness are determined by using the solution map of impedance matching. A wide band microwave absorbance is predicted with controlled ferrite volume fraction and absorber thickness.