• 제목/요약/키워드: Rubber Materials

Search Result 1,027, Processing Time 0.029 seconds

A Study on Enhancement of the Durability of Permeable Pavement Material (투수성 도로포장재의 내구성 향상에 관한 연구)

  • Oh, Hun-Su;Hong, Young-Keun
    • Elastomers and Composites
    • /
    • v.42 no.2
    • /
    • pp.93-101
    • /
    • 2007
  • In this study, for enhancing the durability of permeable pavement material polyurethane(PU) adhesives were developed, and the physical properties upon polymerization and additives were studied. PU polymerization followed the bulk polymerization of free solvent type considering ecological aspect. Additives used in this study were carbon black, calcium carbonate and ultra violet stabilizer. The property changes upon different environment were evaluated with the compressive strength which is the principal measurement of the property of pavement materials. Among polymerized PU, one formulated with esterpolyol and crosslinkable chain extender gave the highest compressive strength of $74.9kgf/cm^2$, better than commercial $60kgf/cm^2$. The strength was the highest when the material specimen contained carbon black and calcium carbonate 20 wt%, respectively. However, UV stabilizer did not show good weathering properties.

Manufacturing a Functional Bolus Using a 3D printer in Radiation Therapy (방사선치료에서 3D 프린터를 이용한 기능적 조직보상체의 제작)

  • Lee, Yi-Seong;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.43 no.1
    • /
    • pp.9-14
    • /
    • 2020
  • Commercial plate bolus is generally used for treatment of surface tumor and required surface dose. We fabricated 3D-printed bolus by using 3D printing technology and usability of 3D-printed bolus was evaluated. RT-structure of contoured plate bolus in the TPS was exported to DICOM files and converted to STL file by using converting program. The 3D-printed bolus was manufactured with rubber-like translucent materials using a 3D printer. The dose distribution calculated in the TPS and compared the characteristics of the plate bolus and the 3D printed bolus. The absolute dose was measured inserting an ion chamber to the depth of 5 cm and 10 cm from the surface of the blue water phantom. HU and ED were measured to compare the material characteristics. 100% dose was distributed at Dmax of 1.5 cm below the surface when was applied without bolus. When the plate bolus and 3D-plate bolus were applied, dose distributed at 0.9 cm and 0.8 cm below the surface of the bolus. After the comparative analysis of the radiation dose at the reference depth, differences in radiation dose of 0.1 ~ 0.3% were found, but there was no difference dose. The usability of the 3D-printed bolus was thus confirmed and it is considered that the 3D-printed bolus can be applied in radiation therapy.

Alignment System Development for producing OLED using Fourth-Generation Substrate

  • Park, Jae-Yong;Han, Seok-Yoon;Lee, Nam-Hoon;Choi, Jeong-Og;Shin, Ho-Seon
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.873-878
    • /
    • 2008
  • Doosan Mecatec has developed alignment system for Organic Light-Emitting Diode (OLED) display production using large size substrate. In the present article, The alignment system between the substrate and the mask, which is a core technology for producing the OLED product using the fourth-generation substrate with $730{\times}920mm^2$ or more, will be described by dividing into a substrate loader, a magnet unit, a CCD camera, etc. The substrate loader is optimized through the simulation where the central portion of the substrate droops by about 1.5mm by clamping each of a long side (920mm direction) and a short side (730mm direction) thereof by 6 point and 4 point. A magnet unit using a sheet type of rubber magnet is constituted and a CCD camera model with the specifications capable of minimizing the errors between a clear image and the same image is selected. The system to which an upward evaporation technique of small molecular organic materials will be applied has been developed so that repeatability and position accuracy becomes ${\pm}1{\mu}m$ or less using an UVW type of stage. Also, the vision accuracy of the CCD camera becomes ${\pm}1{\mu}m$ or less and the align process TACT becomes 30sec. or less so that the final alignment accuracy between the substrate and the mask becomes ${\pm}3{\mu}m$ or less. In order to meet an extra-large glass substrate, an evaporation system using an extra-large AMOLED substrate has been developing through a vertical type of an alignment system.

  • PDF

FABRICATION OF TISSUE ENGINEERED MYO-MUCOSAL FLAP BY GRAFTING THE COMPLEX OF AUTOLOGOUS ORAL KERATINOCYTES AND PLATELET RICH PLASMA(PRP) IN A RAT MODEL (백서에서 자가 구강점막세포와 혈소판 농축 혈장의 이식에 의한 점막 근 피판의 조직공학적 제작)

  • Lee, Bu-Kyu;Hwang, Jin-Hyuk
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.33 no.4
    • /
    • pp.322-330
    • /
    • 2007
  • Backgrounds: To overcome limited amount of autogenous mucosa for the reconstruction of various mucosal defect including oral mucosal defect, tissue engineered mucosa has been recently introduced. However, introduced conventional technique of tissue engineered mucosa still have serious pitfalls such as long fabrication time, fragility of the reconstructed mucosa, and complexity of the technique. Aim of the study: To examine whether the complex of preconfluent autologous keratinocytes and autologous PRP(Platelet rich plasma) can reconstruct oral mucosa on the muscular flap with easier and faster way compared to conventional mucosal tissue engineering technique. Materials and methods: One day before the operation, oral mucosa(3mm in diameter) were taken and treated for extraction of oral keratinocytes according to the routine manner. The day of operation, oral keratinocytes were prepared in the laboratory and then moved to the operating theater. Autologous PRP was also prepared and then mixed with oral keratinocytes just before grafting on the prepared muscular flap. After keratinocyte-PRP complex was seated, then a sterilized rubber sheet was placed on the graft and the elevated skin flap was replaced and sutured. Biopsies were proceeded at 3, 5, 7, 14 and 21 days. Tissue samples were evaluated clinically, histologically, and immunohistochemically. Results: All of the oral keratinocyte-PRP complexes were successfully grafted on the recipient sites(100%). On 3 days after the operation, 1-2 continuous epithelial layer and many inflammatory cells were observed. On 5 days after the operation, increase of layers of keratinocyte was observed with less inflammatory response. Thickness of the layers was gradually increased from 7 to 21 days after the operation. Cytokeratin confirms epithelium in every specimen. Conclusions: Preconfluent graft of autogenous oral keratinocytes mixed with autogenous PRP have successfully reconstructed myo-mucosal flap. This technique could be a useful alternative for oral mucosal reconstruction in the near future.

Effective Analysis on the Mechanical Behavior of a Refrigerator using Equivalent Material Properties of Multi-layers (다중재질 접합구조의 등가물성을 이용한 효과적 냉장고 구조 변형 분석에 관한 연구)

  • Park, Jeong-Hyun;Lee, Dong-Kyu;Park, Sang-Hu;Park, Ki-Hong;Ha, Byeong-Kuk;Kim, Hyeong-Sik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.29 no.11
    • /
    • pp.1228-1235
    • /
    • 2012
  • A refrigerator has many components which are made from diverse materials such as metal, polymer, plastic, and rubber. So, it generally requires much time and efforts to build up an analysis model in finite element analysis. In this work, to reduce the computational time and efforts a simplified modeling method was proposed for the analysis of a refrigerator. Occasionally, a stick-slip noise occurs in a refrigerator due to relative slip between shelf and inner-case. When we solve the problem by a FE analysis, we should model the structures with detail for considering the contact conditions; by this reason, too many efforts are consumed in the conventional analysis method. Through this work, we shows the concept of simplifying approach and a good agreement with the results of a real model analysis. And also, the evaluation of the proposed method and the application of contact analysis using the simplified model are discussed.

The Aspiration of Foreign Body in the Left Tracheobronchial Tree during Gold Crown Restoration -A Case Report- (금관 수복치료 후 발생한 좌측 기관지 내로의 금관 흡인에 관한 증례보고)

  • Shin, Teo-Jeon;Seo, Kwang-Suk;Kim, Hyun-Jeong
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.10 no.1
    • /
    • pp.54-57
    • /
    • 2010
  • Foreign body aspiration (FBA) into the tracheobronchial tree could be life threatening requiringprompt intervention. Any objects placed in the oral cavity put patients at a risk of aspirating or swallowing the objects slipped or broken by physical injuries. Here, we report a case of 30 yr old patient with FBA during gold crown replacement was successfully treated with the use of the flexible bronchoscope. Case: A 30 yr old woman was admitted to Seoul National Dental Hospitalfor an amalgam restoration. She was scheduled to gold crown restoration for replacement of the damaged amalgam at #37 site. After performing crown lengthening procedure, the aspiration of gold crown occurred during the cementation of the crown. After aspiration, the patients complained of the subjective distress of respiration. Chest radiograph revealed that gold crown was enlodged to the left bronchus. Flexible fiberoptics was inserted to the bronchus to remove the aspirated crown. Fiberoptic assisted removal of the aspiratedcrown was successfully performed. After removal, there was no radiopaque material in the left bronchus on follow-up chest radiograph. Discussion: When aspiration of dental materials occurs, flexible fiberoptic can be used in the treatment of FBA. It is also very useful to take preventive management such as rubber dam, application of dental floss in dental procedure where there is high likelihood of FBA.

Comparison of Marginal Fitness of Zirconia Copings According to Impression Techniques and Zirconia Blocks (구강인기방법과 블록 종류에 따른 지르코니아 코핑의 변연적합도 비교)

  • Chung, In-Sung;Jeon, Byung-Wook;Kim, Won-Young
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.151-157
    • /
    • 2016
  • The purpose of this study was to compare of marginal fitness of zirconia copings according to impression techniques and zirconia blocks. For the conventional impression, two types of rubber impression materials were used and digital impression was made by using an intraoral scanner. Zirconia copings were manufactured from three types of blocks. With each of ten zirconia copings was determined by surface roughness and marginal fitness. For surface roughness, LUXEN Smile($2.3{\pm}0.9{\mu}m$) block was superior. And the lowest mean values and standard deviations of marginal gap for the HL specimens were $26.5{\pm}2.1{\mu}m$ for buccal, $27.2{\pm}2.1{\mu}m$ for lingual, and that of the HJ specimens $29.6{\pm}4.0{\mu}m$ for mesial, $29.0{\pm}3.0{\mu}m$ for distal. One-way ANOVA showed statistically significant difference between groups for marginal fitness(p<0.05). From the above results, the impression techniques and zirconia blocks had influence on marginal fit of the zirconia copings. Also the marginal fitness of all groups showed clinically acceptable range.

A Comparative Study on Toxic Gas Index and Stop Time of Mouse Activity (연소독성지수와 마우스 행동정시시간 비교 연구)

  • Cho, Nam-Wook;Lee, Jong-Cheon;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.35-41
    • /
    • 2011
  • Casualties due to toxic smoke products have been reported as major fire damage. There are various tests in order to evaluate toxic smoke from a fire at home and abroad, and KS F 2271 as a test of the gas hazard of building finish materials has been conducted in Korea. The current test of the gas hazard exposes rodent, laboratory rat, to smoke gases to evaluate combustion gas toxicity by measuring acting time of that. this study performed a test of the gas hazard for combustible polymer material, Urethane and rubber flooring, and determined gases with the FT-IR. Quantitative results compared with standard value defined in BS6853 and toxicity index (R) was calculated. Using relative comparison with animal test and the toxicity index, We tried a variety of toxicity evaluation by correlation analysis of two tests.

Establishment of Ultrasonic Measurement and Correlations of Direct-Indirect Method for Weathering Evaluation of Stone Cultural Heritage (석조문화재 풍화도 평가를 위한 초음파 측정의 설정과 직접-간접전달방법의 상관관계)

  • Lee, Chan-Hee;Jo, Young-Hoon;Chun, Yu-Gun
    • Journal of Conservation Science
    • /
    • v.25 no.3
    • /
    • pp.233-244
    • /
    • 2009
  • This study was focused on the transducer and suitable contact material for stone cultural heritage, and the correlation of direct-indirect method in rock types for scientific development and quantitative evaluation technique of the ultrasonic measurements. As a result, it was identified the transducer (UTREXTX(RX)54kHz) and contact material (rubber clay) of the type 3 were appropriate for the ultrasonic measurements of stone cultural heritage. The direct-indirect correction factors of type 3 were calculated 1.50 for granite, 1.38 for gabbro, 1.58 for quartz diorite, respectively. This result is the first study for improvement in reliability for the ultrasonic measurements, and it will contribute to establishment of the ultrasonic survey method for stone cultural heritage. Also, complementary studies considering the surface irregularity of rocks and various contact materials will carry out, and the database about correlation of direct-indirect in rock types will establish.

  • PDF

An Experimental Study on the Fire Risk Assessment & Calculation Breakthrough Time through Permeation Test of Chemical Protective Clothing (화학보호복의 화재위험성 및 화학적 투과시험을 통한 파과시간산정에 관한 실험적 연구)

  • Ko, Jae-Sun;Park, Pyoung-Kyu
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.21-30
    • /
    • 2010
  • We have test chemical resistance and flame retardant properties of chemical protective clothing Fabrics by the ASTM and ISO standard methods. The flame retardant test results show that polyethylene is poor in flame resistance but fluoroelastomer add to decabrom is excellent in flame resistance. Especially, nowadays heat protective clothing for firefighters, which is aluminized film layers laminated to aramid fabric, show the excellent flame resistance. However, the chemical resistance test results show that aluminium is high corrosive in 4M NaOH solution alone. The problem of corrosion can be overcome by employing multiple barrier film. Also, based on the result of flame retardant test, duel skin of polymer barrier film add to aluminum film and single skin of fluorinated rubber with flame retardant materials seems to be fit for the chemical protective clothing. Also the thermal protection and heat transfer test results show that TPP and HTI is increased assured that the continued study on fire risk assessment & chemical resistance of chemical protective clothing fabrics will contribute to the upgrade the performances of chemical protective clothing fabrics.