• Title/Summary/Keyword: Rubber Isolator

Search Result 98, Processing Time 0.025 seconds

Development of Conical Rubber Mount using Compression and Shear Elasticity (압축 및 전단탄성을 이용한 원형 방진 고무 마운트 개발)

  • 김종연;권오병;김영구;김영중
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.393-398
    • /
    • 2002
  • Rubber isolator has properties that can adjust easily stiffness and can be formed various shape. Also, it has high damping and is effective about structure-borne noise at high frequency range, So, rubber mount has widely used to isolate vibration at industrial equipment and construction field. However, rubber material is nonlinear and require enough consideration about shape factor whenever it is designed. The purpose of this paper is to develop conical rubber mount using compression and shear elasticity. The first, the dimension of mount is calculated by theoretical analysis considering design condition and static characteristics have been analyzed by FEM method. In addition, the fatigue test of rubber mount is performed to get reliability for product life and dynamic stiffness test is executed to get dynamic magnification factor. Finally, transmissibility test of vibration isolator has been carried out to suggest normal quantity data about vibration isolation.

  • PDF

Developing Microcellular Foamed Vibration Isolator for DVD by Axiomatic Approach (공리적 접근을 이용한 DVD용 초미세 발포 방진재 개발)

  • Jeong, Pil-Jung;Cha, Seong-Un
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.12
    • /
    • pp.101-106
    • /
    • 2000
  • As the rotational speed of optical disk drive is increasing nowadays, the reliability to vibration and shock becomes more important. For this, various of rubber vibration isolators are being developed by varying the shape and hardness. But it is difficult for the hardness of common used rubber to be lowered below Duro 30 degrees, and because of the shape complexity of rubber vibration isolator there are difficulties of analysis. Microcellular foamed vibration isolator has various cell densities and cell sizes, so it can vary the stiffness and damping coefficient. In addition, its hardness can be lowered below Duro 30 degrees. Axiomatic Approach is very useful design method for designing new product or new process. Axiomatic Approach's character is scientific and analytical method. In this paper, developing process of microcellular foamed vibration isolator for DVD is presented with Axiomatic Approach.

  • PDF

An Experimental Study on Fiber Reinforced Strip Form Isolator (스트립형의 섬유 면진 베어링의 실험적 해석)

  • 문병영;강경주;강범수
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.03a
    • /
    • pp.409-416
    • /
    • 2002
  • In order to apply seismic isolators to the low-cost buildings, seismic isolators have to be low-cost and light. In this paper fiber reinforced strip form isolator in which the steel plates of conventional rubber bearing was replaced by fiber was proposed. The proposed fiber reinforced strip form isolator was designed, fabricated, cut and subjected to vertical test and harizontal test. Therefore fiber reinforced strip form isolator was to be shown valid in the view point of fabrication and application to desired size. The harizontal test and vertical test have shown that fiber reinforced strip form isolator could replace the rubber isolator. By these results, low-cost and light seismic isolator can be applied to the low-cost building. These fiber reinforced strip form isolator can be applied to the low-cost building.

  • PDF

Mechanical Characteristic Analysis of Fiber Reinforced Strip Form Elastomeric Bearing by Experiment (스트립형 섬유 보강 탄성받침의 실험에 의한 기계적 특성해석)

  • 강경주;문병영;강범수;김계수;박진삼
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.6 no.6
    • /
    • pp.1-6
    • /
    • 2002
  • In order to apply seismic isolators to low-cost buildings, seismic isolators have to be low-cost and light. In this paper fiber reinforced strip form isolator in which the steel plates of conventional rubber bearing were replaced by fiber was proposed. The proposed fiber reinforced strip form isolator was designed, fabricated, cut and subjected to vertical test and horizontal test. Therefore, fiber reinforced strip form isolator was to be shown valid in the view point of fabrication and application to desired size. The horizontal test and vertical test have shown that fiber reinforce strip form isolator could be replaced the rubber isolator. By these results, low-cost and light seismic isolator can be applied to the low-cost building.

Performance Test of Isolator for Reaction Wheel Micro-Vibration (인공위성 반작용휠 미소진동 감쇠기의 성능 측정)

  • Oh, Shi-Hwan;Seo, Hyun-Ho;Yim, Jo-Ryeong;Rhee, Seung-Wu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.376-379
    • /
    • 2006
  • Reaction Wheel Assembly (RWA) is one of the major disturbance sources that have influence upon the Line of Sight (LOS) of payload. A micro-vibration induced by RWA is propagated through the satellite structure and decrease the LOS stability performance of payload. This effect shall be analyzed through the jitter analysis. If a requirement or specification of payload jitter level is found to be not satisfied according to the jitter analysis campaign, some modification or redesign should be done on the satellite structure or a couple of isolator should be attached on the RWA interface in order to reduce the transmitted vibration level of RWA. The purpose of ???RWA isolator test? is to roughly evaluate the performance of vibration suppression level with a passive RWA isolator made of rubber. For this test, actual RWA is used as a vibration source and a couple of cube-shaped rubber mount designed for satellite is used as a passive isolator. There may be several considerations in order to accommodate RWA isolator to spacecraft such as not only vibration reduction performance but also thermal conduction problem, mechanical size, RWA alignment problem, etc. But in this report the feasibility of RWA isolator is analyzed only in a vibration suppression point of view. As a result, high frequency vibration of RWA above 50Hz is perfectly attenuated with isolators, however, first harmonic components below 50Hz became larger due to the additional low frequency resonance modes of roll, pitch, yaw rigid body motion of RWA+bracket.

  • PDF

Evaluation for Fatigue Life of Rubber Isolator for Vibration Characteristic on Automotive Cooling Module (진동 특성을 고려한 자동차 냉각모듈 방진고무의 내구성 평가)

  • Shim, Hee-Jin;Kim, Han-Chul;Kim, Jung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.350-355
    • /
    • 2008
  • A Rubber mount is widely used for mechanical parts or engineering materials. Especially, it plays an important role in reducing mechanical vibration due to cyclic loading. But, rubber mount is damaged due to the cyclic loading and resonance. Therefore, it is necessary to investigate evaluation of fatigue life considering vibration characteristics for rubber. In this study, a vibration fatigue analysis was performed and based on Power Spectral Density(PSD) and the stress-life curve and a result of frequency response analysis in the finite element method. The measured load history in experiment was transformed to PSD curve. The stress-life curve was obtained by nonlinear static analysis and fatigue test. In addition, frequency response analysis was conducted for mechanical part. In order to evaluate fatigue life of rubber mount, vibration fatigue test was conducted at the constant acceleration-level as well. Fatigue life was determined when the load capacity is reduced to 60% of its initial value. As a result, predicted fatigue life of rubber mount agreed fairly well with the experimental fatigue life.

  • PDF

Seismic performance assessment of reinforced concrete bridge piers supported by laminated rubber bearings

  • Kim, T.H.;Kim, Y.J.;Shin, H.M.
    • Structural Engineering and Mechanics
    • /
    • v.29 no.3
    • /
    • pp.259-278
    • /
    • 2008
  • This paper presents a nonlinear finite element procedure accounting for the effects of geometric as well as material nonlinearities for reinforced concrete bridge piers supported by laminated rubber bearings. Reinforced concrete bridge piers supported by laminated rubber bearings and carrying a cyclic load were analyzed by using a special purpose, nonlinear finite element program, RCAHEST. For reinforced concrete, the proposed robust nonlinear material model captures the salient response characteristics of the bridge piers under cyclic loading conditions and addresses with the influence of geometric nonlinearity on post-peak response of the bridge piers by transformations between local and global systems. Seismic isolator element to predict the behaviors of laminated rubber bearings is also developed. The seismic performance of reinforced concrete bridge piers supported by laminated rubber bearings is assessed analytically. The results show good correlation between the experimental findings and numerical predictions, and demonstrate the reliability and robustness of the proposed analytical model. Additionally, the studies and discussions presented in this investigation provide an insight into the key behavioral aspects of reinforced concrete bridge piers supported by laminated rubber bearings.

Variations in the hysteretic behavior of LRBs as a function of applied loading

  • Ozdemir, Gokhan;Bayhan, Beyhan;Gulkan, Polat
    • Structural Engineering and Mechanics
    • /
    • v.67 no.1
    • /
    • pp.69-78
    • /
    • 2018
  • The study presented herein focused on the change in hysteretic force-deformation behavior of lead rubber bearings (LRBs). The material model used to idealize response of LRBs under cyclic motion is capable of representing the gradual attrition in strength of isolator unit on account of lead core heating. To identify the effect of loading history on the hysteretic response of LRBs, a typical isolator unit is subjected to cyclic motions with different velocity, amplitude and number of cycles. Furthermore, performance of an LRB isolated single degree of freedom system is studied under different seismic input levels. Finally, the significance of lead core heating effect on LRBs is discussed by considering the current design approach for base isolated structures. Results of this study show that the response of an LRB is governed strongly by the amplitude and number of cycles of the motion and the considered seismicity level.

Development and Shaking Table Tests of a Base Isolator for Controling Subway Train-Induced Vibration of a Steel Building (지하철 진동에 대한 철골건물 기초진동 절연장치의 개발 및 진동대 실험)

  • Kim, Jin-Koo;Song, Young-Hoon;Kwun, Hyong-Oh;Huh, Young
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.789-796
    • /
    • 1997
  • In this study a conventional rubber mount and a new form of base isolator made of steel spring coated with natural and articial rubber were manufactured and tested on a shaking table to investigate the capacity of reducing the vertical vibration of a building induced by subway train. The model structure used in the test is a 1/4 scaled steel structure, and a white noise input and train vibration records were used to check the effectiveness of the isolators. According to the results all three types of isolators turned out to perform effectively in reducing the acceleration and the natural rubber-coated one is ranked best among the isolators. However the vertical displacement of the model is increased due to the instolation of the bearings, and the safty against the lateral load induced by earthquake ground motion should be provided to be able to apply the system to the real buildings.

  • PDF

Seismic protection of LNG tanks with reliability based optimally designed combined rubber isolator and friction damper

  • Khansefid, Ali;Maghsoudi-Barmi, Ali;Khaloo, Alireza
    • Earthquakes and Structures
    • /
    • v.16 no.5
    • /
    • pp.523-532
    • /
    • 2019
  • Different types of gas reservoir such as Liquid Natural Gas (LNG) are among the strategic infrastructures, and have great importance for any government or their private owners. To keep the tank and its contents safe during earthquakes especially if the contents are of hazardous or flammable materials; using seismic protection systems such as base isolator can be considered as an effective solution. However, the major deficiency of this system can be the large deformation in the isolation level which may lead to the failure of bearing system. In this paper, as a solution, the efficacy of an optimally designed combined vibration control system, the combined laminated rubber isolator and rotational friction damper, is investigated to evaluate the enhancement of an existing metal tank response under both far- and near-field earthquakes. Responses like impulsive and convective accelerations, base shear, and sloshing height are studied herein. The probabilistic framework is used to consider the uncertainties in the structural modeling, as well as record-to-record variability. Due to the high calculation cost of probabilistic methods, a simplified structural model is used. By using the Mont-Carlo simulation approach, it is revealed that this combined isolation system is a highly reliable system which provides considerable enhancement in the performance of reservoir, not only leads to the reduction of probability of catastrophic failure of the tank but also decrease the reservoir damage during the earthquake. Moreover, the relative displacement of the isolation level is controlled very well by this combined system.