• 제목/요약/키워드: RraA

검색결과 31건 처리시간 0.031초

부위별 생체 전기 임피던스법을 이용한 체성분 분석에 관한 연구 (Segmental Bioelectrical Impedance Analysis(SBIA) for Determining Body Composition)

  • 차기철;손정민;김기진;최승훈
    • 대한지역사회영양학회지
    • /
    • 제2권2호
    • /
    • pp.179-186
    • /
    • 1997
  • A new bioelectrical impedance method has been developed and evaluated. The electrodes; were made of stainless steel and electrical interfaces were created by an upright subject gripping hand electrodes and stepping onto foot electrodes. Eight tactile electrodes were in contact with surfaces of both hands and feet; thumb, palm and fingers, front sole, and rear sole. Automatic on-off switches were used to change current pathways and to measure voltage differences for target segments. Segmental body resistances and whole body resistance(RWHOLE)were measured in 60 healthy subjects. Segmental resistances of right arm(RRA), left arm(RLA), trunk(RT), right leg(RRL) and left leg(RLL)were310.0$\pm$61.6$\Omega$, 316.9$\pm$64.6$\Omega$, 25.1$\pm$3.4$\Omega$, 236.8$\pm$31.2$\Omega$ and 237.6$\pm$30.4$\Omega$, respectively. Individual segmental impedance indexes(Ht2/RRA, Ht2/RT, and Ht2 /RLA) were closely related to lean body mass(LBM)as measured by densitometry ranged from r=0.925 to 0.960. Ht2/(RRA+RT+RLA) predicted LBM slightly better(r=0.969) than the traditional index, Ht2/RWHOLE(r=0.964), supporting the accuracy of the segmental measurement. A multiple regression equation utilizing Ht2/RRA, Ht2/RT and Ht2/RRL predicted LBM with r=0.971. Ht2/RRA term of the regression contributed to more than 40$\%$ of the LBM prediction, indicating that lean mass of arm represented whole body LBM more closely than other body segments. The new bioimpedance method was characterized by upright posture, eight tactile electrodes, segmental measurements and utilization of electronic switches in comparison with the traditional method. The measurement with this new method was extremely reproducible, quick and easy to use.

  • PDF

서로 다른 위치 규칙성을 가지는 두 개의 Poly(3-hexylthiophene) 공액 고분자를 기반으로 한 고분자 복합 박막의 구조와 전기적 특성에 대한 연구 (Study on the Morphologies and Electrical Properties in Polymer Blend Thin-Films Based on Two Poly(3-hexylthiophene) Conjugated Polymers with Different Regio-regularities)

  • 정강훈;Nann Aye Mya Mya Phu;박래수;윤정우;고영운;장민철
    • Composites Research
    • /
    • 제36권5호
    • /
    • pp.349-354
    • /
    • 2023
  • Poly(3-hexylthiophene) (P3HT)는 유기 용매에서 높은 용해도를 가지고 있으면서 상대적으로 쉽게 구할 수 있는 공액 고분자 중 하나이다. 그러나, 전자소자의 활성 소재로써 전기적 특성은 실제로 응용하기에는 부족하므로 추가 개선이 필요하다. 본 연구에서는, 서로 다른 위치 규칙성 (regio-regularity)을 가지는 두 P3HT 고분자 (즉, regioregular (RR) P3HT 및 regio-random (RRa) P3HT)를 혼합하여 혼합 박막의 전하 전달 특성을 크게 향상시킬 수 있음을 보여준다. 두 P3HT 고분자 간 비율을 변화시킴으로써 혼합 박막의 구조적 및 전기적 특성을 체계적으로 조사하였으며, 원자 힘 현미경(AFM), X선 회절(XRD) 및 UV-vis 흡수분광법을 사용하여 혼합 필름의 구조 및 광전자적 특성을 평가하였다. 혼합 박막의 결정성은 RRa-P3HT 함량이 20 wt%로 증가함에 따라 증가하였으며, 이후 80%까지 증가함에 따라 감소하였다. 전하 이동도의 경향성 또한 이와 같았으며, 20 wt%의 RRa-P3HT를 포함하는 혼합 박막의 전하 이동도는 가장 높은 0.029 cm2/V·s로 측정되었고 함량이 80 wt%까지증가함에따라 0.0007 cm2/V·s 로감소하였다.

An SS_RRA Protocol for Integrated Voice/Data Services in Packet Radio Networks

  • Lim, In-Taek
    • Journal of information and communication convergence engineering
    • /
    • 제5권2호
    • /
    • pp.88-92
    • /
    • 2007
  • In this paper, an SS-RRA protocol that is based on Code Division Multiple Access is proposed and analyzed under the integrated voice and data traffic load. The backward logical channels consist of slotted time division frames with multiple spreading codes per slot. The protocol uses a reservation mechanism for the voice traffic, and a random access scheme for the data traffic. A discrete-time, discrete-state Markov chain is used to evaluate the performance. The numerical results show that the performance can be significantly improved by a few distinct spreading codes.

방송통신 유선 설비에 접속되는 단말장치 기술기준 개선 연구 (A Study on the Improvement of Technical Regulation for Terminal Equipment connected to Wired Broadcasting and Communications Facilities)

  • 김봉석;최문환;조평동
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2013년도 추계학술대회
    • /
    • pp.813-816
    • /
    • 2013
  • 국립전파연구원에서는 방송통신설비의 운용자 및 이용자의 안전과 서비스 품질 향상을 위하여 위해 방지 및 오용, 고장 방지, 장애인에 대한 접근의 용이성, 단말장치간 상호호환성, 전송 품질과 망 접속 등에 관한 단말장치의 세부 기술기준을 정하여 고시하고 있으며, 방송통신설비 기술의 발전과 서비스의 다변화에 빠르게 대응하기 위하여 단말장치 기술기준의 제 개정 연구를 추진하고 있다. 2013년 신규 융합 서비스 및 초고속 인터넷 서비스의 확산, 방송통신 서비스의 품질 제고를 위해 단말장치의 신호 전력 측정 대역의 확장과 의사회로의 대체 종단 사용 기준, 디지털 회선 접속 단말의 펄스 형상 기준 등에 대한 연구를 추진하고 이에 대한 타당성 검증을 위한 테스트베드 시험 결과를 제시하였다.

  • PDF

7050 Al 합금의 RRA 처리에 관한 연구 (A Study on the RRA(Retrogression and Reaging) treatment of 7050 Al alloy)

  • 최중환;김장량;이상래;김인배
    • 한국재료학회지
    • /
    • 제10권7호
    • /
    • pp.493-498
    • /
    • 2000
  • 7050 AI합금을 RRA 처리하였을 때 경도, 전기전도도 및 미세조직의 변화를 조사하였다. 120도씨에서 24시간 동안 1차 시효처리한 후 175도씨에서 2차 퇴화처리하였을 때 경도값의 변화는 초기에 감소하다가 피크 경도를 보인 다음 다시 감소하였으며, 3차 재시효처리재가 2차 시효처리재 보다 큰 경도값을 나타내었다. 2차 퇴화처리시 초기 경도 감소는 T6의 주 강화상인 GP zone의 부분적인 분해에 의한 것이며, 3차 재시효 처리하였을 때 강화상은 GP zone과 파이상이었다. 120도씨에서 24시간 동안 1차 시효처리한 후 175도씨에서 2차 퇴화처리하였을 때 전기전도도 변화는 퇴화 쵤부터 연속적으로 증가혀였으며, 3차 재시효처리에 의해 2차 퇴화처리시 보다 %IACS가 0.5 ~ 2.7 증가하였다. 3단시효에 의해 T6정도의 강도를 유지하면서 38%IACS값 이상의 전기전도도를 얻을 수 있는 최적 퇴화처리 조건은 $175^{\circ}C$ 50분이었다. 이는 퇴화처리 경도곡선의 극소점 또는 극대점과 무관하며 오히려 약간 과시효 조건이다.

  • PDF

RRA : 무선센서 네트워크에서 노드의 통신영역을 고려한 랜덤 배치 고정형 라우팅 알고리즘 (RRA : Ripple Routing Algorithm Considering the RF-Coverage of the node in WSN)

  • 이두완;김민제;장경식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.820-823
    • /
    • 2011
  • 무선 센서 네트워크는 제한적인 H/W의 자원을 가지고 동작되는 작은 센서들로 구성되어 있다. 이러한 무선 센서노드들은 초기에 대량으로 랜덤하게 배치되어 스스로 클러스터를 구성하고, 각 클러스터의 헤드노드를 선출하여 정상적인 통신이 이루어져야 한다. 이러한 일련의 작업을 무선 센서노드 설치시 관리자가 직접적으로 관여할 수 없기 때문에 자가 구성 라우팅 기능이 가능하여야 한다. 본 논문에서 제안하는 네트워크 구성 알고리즘은 베이스 스테이션이 전체 네트워크를 통제하는 계층형 클러스터링 구조로, 초기 네트워크 구성시 노드의 통신영역내에 있는 노드를 검색하여 네트워크를 구성한다. 제안한 알고리즘은 초기 노드 배치시 구성될 수 있는 가장 빠른 네트워크 연결 구조로 네트워크 트래픽의 오버헤드를 줄일 수 있다.

  • PDF

Influence of Retrogression and Re-aging on the Exfoliation Corrosion Behavior of AA 7085 Sheets

  • Krishnan, Ajay;Raja, V.S.;Mukhopadhyay, A.K.
    • Corrosion Science and Technology
    • /
    • 제15권4호
    • /
    • pp.159-165
    • /
    • 2016
  • An attempt has been made to understand the influence of retrogression and re-aging (RRA) on the exfoliation corrosion behaviour of AA 7085 alloy in comparison with the peak aged condition (PA). Immersion tests using ASTM G34 and studies involving electrochemical impedance spectroscopy showed that the RRA treated alloy provided higher resistance to exfoliation corrosion than the PA treated alloy. The improved resistance was attributed to the enhanced Cu content and the discontinuous nature of the grain boundary precipitate, which was revealed through transmission electron microscopy.

PCS 네트워크에서 3-레벨 데이터베이스 구조를 위한 효과적인 위치 캐시 기법 (An Efficient Location Cache Scheme for 3-level Database Architecture in PCS Networks)

  • 한연희;송의성;황종선;정영식
    • 한국정보과학회논문지:정보통신
    • /
    • 제29권3호
    • /
    • pp.253-264
    • /
    • 2002
  • 최근에, 개인 통신 시스템(PCS)에서 증가하는 개인 사용자의 수요에 대처하기 위하여 위치 관리 데이타베이스의 계층적 구조가 제안되어 왔다. 특히, 3-레벨 계층적 데이타베이스 구조는 현재 셀룰러 이동 시스템에 쉽게 적용 가능하며, 이 구조에서는 기존 HLR과 VLR 사이에 새로운 부가적 데이터베이스인 지역 위치 데이타베이스 RLR이 위치한다. 본 논문은 이동단말의 위치 관리를 위한 효과적인 캐시 기법인 이중 T-임계값 위치 캐시 기법을 제안한다. 이 기법은 IS-41과 GS에 적용된 위치 관리 데이타베이스의 2-레벨 구조에 응용할 수 있는 기존 T-임계값 캐시 기법을 확장한 것이다. 제안하는 기법은 2개의 캐시 정보, 즉 현재 피 호출 이동단말을 서비스하고 있는 VLR과 RLR 정보를 함께 이용한다. 이 두개기 캐시 정보를 통하여, 등록 영역(RA)의 지역성과 RLR에 의해 관리되는 영역인 지역 등록 영역(RRA)의 지역성을 동시에 이용할 수 있다. 또한, 제안하는 기법은 두 개의 캐시 정보가 유효한지를 결정하기 위하여 각각에 대응되는 두 개의 임계값을 이용한다. 한편, RRA 상주시간을 모델링하기 위하여, Branching Erlang-$\infty$ 분포를 이용하고, 이것을 이용한 비용 분석은 제안하는 기법이 이동단말의 대부분의 유형에 대하여 네트워크와 데이타베이스 비용을 대폭 감소시킴을 보여준다.

Baseline Stimulated Thyroglobulin Level as a Good Predictor of Successful Ablation after Adjuvant Radioiodine Treatment for Differentiated Thyroid Cancers

  • Fatima, Nosheen;uz Zaman, Maseeh;Ikram, Mubashir;Akhtar, Jaweed;Islam, Najmul;Masood, Qamar;Zaman, Unaiza;Zaman, Areeba
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권15호
    • /
    • pp.6443-6447
    • /
    • 2014
  • Background: To determine the predictive value of the baseline stimulated thyroglobulin (STg) level for ablation outcome in patients undergoing adjuvant remnant radioiodine ablation (RRA) for differentiated thyroid carcinoma (DTC). Materials and Methods: This retrospective study accrued 64 patients (23 male and 41 female; mean age of $40{\pm}14$ years) who had total thyroidectomy followed by RRA for DTC from January 2012 till April 2014. Patients with positive anti-Tg antibodies and distant metastasis on post-ablative whole body iodine scans (TWBIS) were excluded. Baseline STg was used to predict successful ablation (follow-up STg <2 ng/ml, negative diagnostic WBIS and negative ultrasound neck) at 7-12 months follow-up. Results: Overall, successful ablation was noted in 37 (58%) patients while ablation failed in 27 (42%). Using the ROC curve, a cut-off level of baseline STg level of ${\leq}14.5ng/ml$ was found to be most sensitive and specific for predicting successful ablation. Successful ablation was thus noted in 25/28 (89%) of patients with baseline STg ${\leq}14.5ng/ml$ and 12/36 (33%) patients with baseline STg >14.5 ng/ml ((p value <0.05). Age >40 years, female gender, PTS >2 cm, papillary histopathology, positive cervical nodes and positive TWBIS were significant predictors of ablation failure. Conclusions: We conclude that in patients with total thyroidectomy followed by I-131 ablation for DTC, the baseline STg level is a good predictor of successful ablation based on a stringent triple negative criteria (i.e. follow-up STg < 2 ng/ml, a negative DWBIS and a negative US neck).

Specular Reflectance Measurements of Dielectric Plates in Millimeter Frequency Range

  • Kang, Jin-Seob;Kim, Jeong-Hwan;Kang, Kwang Yong;Yoon, Dae Hwan;Park, Sung Won
    • Journal of electromagnetic engineering and science
    • /
    • 제18권2호
    • /
    • pp.78-87
    • /
    • 2018
  • This paper describes specular reflectance measurements of dielectric plates in three waveguide frequency bands: D-band (110-170 GHz), G-band (140-220 GHz), and J-band (220-325 GHz). The transmit (Tx) part of the proposed specular reflectance measurement system is stationary, while the receive (Rx) part and the material under test (MUT) holder are concentric-rotating with a 2:1 speed ratio for specular reflectance measurements. In specular reflectance measurements, the first step measures the specular reflection coefficients of an MUT and a metal plate on the MUT holder located at the center of the Tx and Rx parts, and the second step calculates the specular reflectance defined by the specular reflection power (i.e., intensity) of the MUT normalized to that of the metal plate. Multiple reflection effects between the Tx and Rx antennas and the MUT on the measured specular reflectance are minimized by averaging out the multiple specular reflectances measured with changing the separation distance between the two antennas by ${\lambda}/8$ intervals. Measurement results of the perpendicular-polarized specular reflectance of commonly used dielectric plates are verified by comparing those with the analytic results and show that the results measured over the overlapped frequency range of the D-/G-bands and at the boundary frequency of the G-/J-bands agree well with the results for the other band, respectively.