• Title/Summary/Keyword: Routine test

Search Result 467, Processing Time 0.029 seconds

DEVELOPMENT OF GENERAL PHYSICS CAI PROGRAM FOR UNIVERSITY SCIENCE AND ENGINEERING STUDENT (이공계(理工系) 학생을 위한 일반물리학 CAI 프로그램의 개발)

  • Kim, Chang-Sik;Yoon, Sung-Ro;Cho, Young-Suk;Kim, Chul-Sung
    • Journal of The Korean Association For Science Education
    • /
    • v.9 no.1
    • /
    • pp.53-67
    • /
    • 1989
  • General Physics CAI Program was developed for university science and engineering student. The program was restricted in the field of mechanics and was mainly aimed for individual tutorial. This project was supported by Government. Department of Education, physics attending their general physics classes in university. The program was written in BASIC and constructed by frame, 4 professors and 6 graduate students were involved in the project. Summary of this study is as follows. 1. The theory of CAI was illuminated from a new point of view to enhance usefullness of CAI. Also the structure of frame type CAI was studied. 2. The program was developed as follows 1) The program consisted of main program, pretest routine, tutorial routine, final test routine, and several other routines for program control. Whole program was written in BASIC. 2) 20 problems for pretest, 90 problems and subsequent hints and solutions for tutorial, 20 problems for final test were developed. 3) According to student's pretest result, tutorial course was routed through several different courses which contain different number of problems 4) The expected rate of achievment for final test was set to 75%. 5) Data of students response to problems including number of tries and time used were recorded for the purpose of achievment analisys 3. 22 students went through whole course and the results were as follows. 1) Pretest marks were widly distributed from 20 points to 100. It means that achievement of high school physics course were not enough. 2) Throughout tutorial course, students who had got higher mark in pretest answered correctly in the first trial at a higher rate of 78 %. Overall rate of correct answer in the second trial was distributed appropriatly. 3) Average mark of final test was 78.8 points, rather a higher rate of achievement than expected. This means that the program was constructed well.

  • PDF

Detection of the Carcinogenic Liver Fluke Opisthorchis viverrini Using a Mini Parasep SF Faecal Parasite Concentrator

  • Kaewpitoon, Soraya J;Rujirakul, Ratana;Tongtawee, Taweesak;Matrakul, Likit;Panpimanmas, Sukij;Wakkuwattapong, Parichart;Loyd, Ryan A;Kaewpitoon, Natthawut
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.1
    • /
    • pp.373-376
    • /
    • 2016
  • The Mini Parasep SF fecal parasite concentrator (MPSFC) is a new modification of the closed concentration system, which can easily be adopted in any routine clinical pathology laboratory. Here we describe our experience with the system in diagnosing Opisthorchis viverrini. A total of 199 fecal samples was submitted for routine examination in the clinical pathology laboratory of Suranaree University of Technology hospital, Nakhon Ratchasima province, Thailand, during August to October 2015. Out of all samples examined, 10 (5.03%) were positive with intestinal parasites including O. viverrini (2.01%), followed by Strongyloided stercoralis (1.51%), Hookworm (0.5%), Taenia spp. (0.5%), and Entamoeba coli (0.5%). Regarding the distribution of intestinal parasites in relation to the methods used, and found that 4 samples (2.01%) were positive using the direct wet smear method while 10 (5.03%) were positive with the Mini Parasep SF method; the difference was statistically significant ($X^2$-test = 116.506, p-value =0.001). Mean time for processing using the Parasep system was 6.03 min/sample, the conventional direct wet smear method at 0.3 min/sample. Cost per test, conventional direct wet smear method costing less than the Parasep method at USD 0.74/sample versus USD 1.47/sample. This first report of O. viverrini detection using MPSFC indicates that Parasep concentration test is useful in the routine laboratory, increasing the yield of parasites as compared to direct microscopy, but with greater processing time and cost. Further comparisons between the Parasep concentration test and common methods for O. viverrini detection are required, particularly concerning use in epidemiological surveys.

Comparing the Change in SUVmax Over Time by the Type of Ductal Breast Carcinoma (유방암 환자 중 유관에서 발병되는 암의 종류(IDC와 DCIS)별 시간경과에 따른 SUVmax 변화에 대한 비교)

  • Hyoung, Mi-Jin;Kim, Jeong Nip;Moon, Pyeong Soo;Kim, Kil Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.140-144
    • /
    • 2014
  • Purpose: The recent surge in breast carcinoma patients is reported in a variety of statistics. Breast cancer occurs mainly from duct and lobulus: 85% is from the breast ducts. The present study is aimed to distinguish the difference in $SUV_{max}$ changing over time by identifying the type of cancers attacking from the duct. Materials and Methods: The subjects of the study are 291 female breast cancer patients who have visited the present PET/CT center from July 1, 2012 to July 23, 2013. Based on the pathological results, 248 IDC (invasive ductal carcinoma) patients and 43 DCIS (ductal carcinoma in situ) patients were selected. In the same manner as the general PET/CT scan (3.7 MBq/Kg), F-FDG was injected, followed by the primary test (Routine tests) after 1 hr, and the secondary test (Delay test) after another hr. $SUV_{max}$ was measured after setting ROI in the lesion based on the data from the two tests. Results: As the comparative result of the change in the lesion $SUV_{max}$ between the two groups, IDC group's $SUV_{max}$ showed M=7.11 and SD=5.405 in the primary test and increased M=7.11 and SD=5.405 in the secondary test (P<0.05); DCIS group's $SUV_{max}$ showed M=2.739, SD=1.229 in the primary test and increased M=2.614, SD=1.470 in the secondary test (P<0.05). Conclusion: As the comparative result of $SUV_{max}$ over time between the groups, IDC showed increased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.000); DCIS showed decreased $SUV_{max}$ in the secondary test (Delay test) compared to the primary test (Routine test) (P=0.039). It was confirmed through this study that the change in $SUV_{max}$ has occurred over time by the type of breast cancer (IDC or DCIS) occurring from the breast ducts. However, the onset of breast cancers (ILC, LCIS) from the lobulus was not discussed due to the lack of samples. Future research on the breast cancers from the lobulus is suggested.

  • PDF

A Bayes Criterion for Testing Homogeneity of Two Multivariate Normal Covariances

  • Kim, Hea-Jung
    • Journal of the Korean Statistical Society
    • /
    • v.27 no.1
    • /
    • pp.11-23
    • /
    • 1998
  • A Bayes criterion for testing the equality of covariance matrices of two multivariate normal distributions is proposed and studied. Development of the criterion invloves calculation of Bayes factor using the imaginary sample method introduced by Spiegelhalter and Smith (1982). The criterion is designed to develop a Bayesian test criterion, so that it provides an alternative test criterion to those based upon asymptotic sampling theory (such as Box's M test criterion). For the constructed criterion, numerical studies demonstrate routine application and give comparisons with the traditional test criteria.

  • PDF

A Bayesian Test Criterion for the Multivariate Behrens-Fisher Problem

  • Kim, Hea-Jung
    • Journal of the Korean Statistical Society
    • /
    • v.28 no.1
    • /
    • pp.107-124
    • /
    • 1999
  • An approximate Bayes criterion for multivariate Behrens-Fisher problem is proposed and examined. Development of the criterion involves derivation of approximate Bayes factor using the imaginary training sample approach introduced by Speigelhalter and Smith (1982). The criterion is designed to develop a Bayesian test, so that it provides an alternative test to other tests based upon asymptotic sampling theory (such as the tests suggested by Bennett(1951), James(1954) and Yao(1965). For the derived criterion, numerical studies demonstrate routine application and give comparisons with the classical tests.

  • PDF

Current perception threshold in diabetic sensory polyneuropathy with normal routine nerve conduction study

  • Park, Kyung Seok;Kwon, Yong Chul;Youn, Minjung;Park, Yong-Shik;Hong, Yoon-Ho;Sung, Jung-Joon
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.2
    • /
    • pp.125-130
    • /
    • 2017
  • Background: Routine nerve conduction study (NCS) can only be used to evaluate the function of large fibers, and the results of NCS are often normal in patients with distal sensory polyneuropathy. The measurement of the current perception threshold (CPT) has been reported to represent a variety of peripheral nerve fiber functions. This study was performed to investigate the value of measuring CPT in patients with diabetic sensory polyneuropathy who have no abnormalities in routine NCS. Methods: Twenty-seven diabetic patients with sensory polyneuropathy and normal routine NCS and 18 age-matched control subjects participated in this study. The CPT was measured on the unilateral index finger and great toe of each subject at frequencies of 5 Hz, 250 Hz, and 2,000 Hz. Results: CPT values were significantly higher in the patient group than in the control group, especially with stimuli at the lowest frequency of 5 Hz (p < 0.05). There were significant correlations between the CPT values obtained at three different frequencies in the patient group, whereas the correlation was only significant in the pair of 250 Hz/5 Hz (both in the hands and feet), and in the pair of 2,000 Hz/250 Hz (in the feet) for the control group. Conclusions: Our data suggest that the CPT test, especially at a stimuli frequency of 5 Hz, may be a useful screening tool for diabetic polyneuropathy in patients who show no abnormalities in routine NCS.

Impact of COVID-19 pandemic on routine immunization services in a tertiary care hospital of Rajasthan, India

  • Madhvi Dhamania;Kusum Gaur
    • Clinical and Experimental Vaccine Research
    • /
    • v.12 no.4
    • /
    • pp.313-318
    • /
    • 2023
  • Purpose: Globally, 25 million children were either unvaccinated or under-vaccinated in year 2021. Among them, India had the highest number of children unvaccinated. Studies have shown impact of coronavirus disease 2019 (COVID-19) pandemic on routine health-care services. Present study aimed to estimate the impact of COVID-19 on utilization of routine immunization services during years 2020 and 2021 in tertiary-care facility. Materials and Methods: Record based descriptive analytic study was conducted at pediatric tertiary-care hospital, Jaipur. Data of children vaccinated as per the National Immunization Schedule for the period January 2019 to December 2021 were retrieved from the immunization records. Doses administered were assessed as a proxy measure of vaccine coverage. The vaccination trends of 2020 and 2021 were compared assuming base year 2019. Unpaired t-test of significance and Pearson correlation was used for correlation analysis. Results: There was significant drop in the vaccine counts after emergence of COVID-19 pandemic. In year 2020 and 2021, mean monthly vaccine count was 2,190±715.1 and 2,305±393.2, respectively, in which maximum drop was in April 2020 (-79.12%) and May 2021 (-57.16%) when it was compared with matched month of base year. There was negative correlation between percent change in vaccine count and COVID-19 cases in 2020 (r=-0.057, p=0.861) and 2021 (r=-0.827, p=0.001) as compared to year 2019. Conclusion: Study concludes that there was a significant gap in utilization of routine immunization services during the COVID-19 pandemic. This necessitates planning and management of routine immunization services in-case of future pandemics to avoid resurgence of vaccine-preventable diseases in the Rajasthan.

Effect of Fall Prevention Education for Older Patients in Comprehensive Nursing Care Service Ward (간호·간병 통합병동에 입원한 노인환자의 낙상예방교육 효과)

  • Shim, Song-mi;Kim, Eunha
    • Journal of Korean Public Health Nursing
    • /
    • v.33 no.2
    • /
    • pp.200-213
    • /
    • 2019
  • Purpose: This study was conducted to examine the effect of a fall prevention education on the fall related knowledge and fall prevention behavior of the elderly patients in comprehensive nursing care service wards. Method: A quasi experimental study with control group and experimental group was used. A total 62 elderly patients in comprehensive nursing care service wards were randomly divided into the experimental group(n=30) and the control group(n=32). The data collection period was from August to December, 2017. Data were analyzed with $X^2-test$, paired t-test, independent t-test and Pearson's correlation coefficient by using SPSS 25.0. Results: Experimental group reported higher score in fall related knowledge than the control group(t=-10.28, p<.001). Participants who viewed DVD and received the leaflet education reported higher score than those with routine admission education(t=-6.51, p<.001). The experimental group showed significant improvement in fall related knowledge and fall prevention behavior(r=.21, p=.015). Conclusion: The fall prevention program was effective in improving fall-related knowledge and fall prevention behavior among elderly patients. Since the DVD plus leaflet education was effective in improving prevention behaviors, it might be included in routine orientation on admission for the elderly patient in comprehensive nursing care service wards.

A Study on Oxygen Saturation, Vital Signs, and Vomiting by Routine Suctioning to Healthy Newborns at Nursery (정상 신생아의 출생 후 흡인에 따른 산소포화도, 활력징후 및 구토)

  • Choi, Hye-Mi;Lee, Ja-Hyung
    • Child Health Nursing Research
    • /
    • v.16 no.2
    • /
    • pp.128-135
    • /
    • 2010
  • Purpose: This study aimed to confirm the effect of routine suctioning at a nursery for healthy newborns who have undergone immediate oronasopharyngeal bulb suctioning after birth in a delivery room through the observation of their oxygen saturation level, heart rate, respiration rate, the vomiting sign, and the number of instances of vomiting. Methods: Data were collected for 62 days from March 15 to May 15, 2009 at the nursery of a hospital located in Seoul. One hundred forty newborns were assigned to one of three groups: a no suction group, an oropharyngeal suction group, or a orogastric suction group. Collected data were analyzed with the SPSS WIN 15.0 program using ANOVA, cross tabulations and an independent 2-sample t-test. Results: Routine suctioning to healthy newborns resulted in decreasing oxygen saturation levels and increasing the heart and respiration rate regardless of the kind of suctioning. Stabilization of the oxygen saturation level and vital signs was also observed without suctioning. Conclusion: To prevent healthy newborns from the side effect of suctioning, selective suctioning is recommended.

Multiplex Quantitative Real-time Polymerase Chain Reaction Assay for Rapid Detection of Mycobacterium avium subsp. paratuberculosis in Fecal Samples (분변 시료에서 Mycobacterium avium subsp. paratuberculosis 의 빠른 검출을 위한 다중 실시간 중합효소연쇄반응기법의 개발)

  • Han, Jae-Ik;Jung, Young-Hun;Choe, Changyong;Yoo, Jaegyu;Kang, Seog-Jin;Yoo, Hansang;Park, Hongtae;Kwon, Eung-Gi;Cho, Yong-Il
    • Journal of Veterinary Clinics
    • /
    • v.32 no.3
    • /
    • pp.219-223
    • /
    • 2015
  • Mycobacterium avium subsp. paratuberculosis (MAP) causes paratuberculosis or Johne's disease, an intestinal granulomatous infection in domestic and wild animals. The study aimed to develop and evaluate a panel of multiplex quantitative real-time polymerase chain reaction (mqPCR) assay for simultaneous detection of three MAP-specific genes (IS900, F57 and ISMAP02 genes). The analytic sensitivity (i.e., limit of detection, expressed as cells per 1 ml) was 150 for IS900, 1500 for F57, and 50 for ISMAP02. The specificity of the method was determined by testing 152 bovine fecal samples. Based on the test, it showed that the assay simultaneously detected the target genes in short period of time and at lower cost compared to laboratory routine tests. The test agreement between the assay and routine test was 94%. The discrepancy in the results was due to samples that were tested positive by the panel but negative by the routine tests, suggesting that the assay has higher sensitivity than the routine tests. In conclusion, the mqPCR assay could be a rapid and accurate testing tool for investigating paratuberculosis or Johne's disease cases in domestic and wild animals.