• Title/Summary/Keyword: Roughness comparison

Search Result 294, Processing Time 0.024 seconds

A Study on Comparison of the Darcy-Weisbach and Hazen-Williams Equation (Darcy-Weisbach와 Hazen-Williams Equation 비교 연구)

  • Kim, Tae-Kyoungi;Rhee, Kyoung-Hoon;Sun, Byoung-Jin;Chio, Cheong-Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.421-428
    • /
    • 2007
  • Many engineering problems on the pipeline flow use continuity, energy, friction loss head equation. To calculate friction loss head in a pipeline, Darcy-Weisbach and many average velocity equations can be used and Hazen-Williams equation is used frequently in the pipe network for the water supply systems. Darcy-Weisbach equation is a general one acquired from applying Bernoulli's equation in the pipeline flow and Hazen-Williams equation is a experimental one in case that pipe velocity is below 3m/sec and pipe diameter is over 50mm. In this study, comparing Darcy-Weisbach with Hazen-Williams equation, relation f and C that are expressed as roughness coefficients of those equations is explained. Next, head losses calculated from using those equations are compared and those are applied in realistic pipelines. Comparing f with C, the f is decreasing linearly according to increase of the Reynolds number Re and increasing in case the C is decreasing. additionally, the C is increasing up to a point and then is decreasing according to increase of the Re. Next, the C is increasing and Re's range for increase of the C lengthens in case of decreasing of the relative roughness ${\varepsilon}/d$. Comparing head losses acquired from the two equations, head loss appears large in case that the C is decreasing and the ${\varepsilon}/d$ is increasing. additionally, Head loss calculated by the Darcy-Weisbach equation varies larger than one by Hazen-Williams equation in regard of the Re. Next, change aspect of head loss acquired by the C is distinguished more clearly than the one by the ${\varepsilon}/d$.

An Experimental Study for the Scale Effects on Shear Behavior of Rock Joint (절리면 전단거동의 크기효과에 관한 실험적 연구)

  • Lee, Sang-Eun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.7 no.3
    • /
    • pp.31-41
    • /
    • 2006
  • The scale effect of specimens on the shear behavior of joints is studied by performing direct shear tests on six different sizes in Granite. The peak and residual shear stress, shear displacement, shear stiffness, and dilation angle are measured with the different normal stress(0.29~2.65MPa) and roughness parameters. It is also shown that both the joint roughness coefficient(JRC) and the joint compression strength(JCS) reduce with increasing joint length. A series of shear tests show about 56~67% reduction in peak shear stress, and about 18~44% in residual shear stress, respectively as the contact area of joint increases from 12.25 to $361cm^2$. Also the variation of dilation angle is $27^{\circ}$ at normal stress of 0.29 MPa and $6^{\circ}$ at normal stress of 2.65 MPa, respectively. The envelopes considering scale effect for JRC are made for the peak shear strength of rock joint in comparison with the Barton's equation.

  • PDF

Comparison of alkaline phosphatase activity of MC3T3-E1 cells cultured on different Ti surfaces: modified sandblasted with large grit and acid-etched (MSLA), laser-treated, and laser and acid-treated Ti surfaces

  • Li, Lin-Jie;Kim, So-Nam;Cho, Sung-Am
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.3
    • /
    • pp.235-240
    • /
    • 2016
  • PURPOSE. In this study, the aim of this study was to evaluate the effect of implant surface treatment on cell differentiation of osteoblast cells. For this purpose, three surfaces were compared: (1) a modified SLA (MSLA: sand-blasted with large grit, acid-etched, and immersed in 0.9% NaCl), (2) a laser treatment (LT: laser treatment) titanium surface and (3) a laser and acid-treated (LAT: laser treatment, acid-etched) titanium surface. MATERIALS AND METHODS. The MSLA surfaces were considered as the control group, and LT and LAT surfaces as test groups. Alkaline phosphatase expression (ALP) was used to quantify osteoblastic differentiation of MC3T3-E1 cell. Surface roughness was evaluated by a contact profilometer (URFPAK-SV; Mitutoyo, Kawasaki, Japan) and characterized by two parameters: mean roughness (Ra) and maximum peak-to-valley height (Rt). RESULTS. Scanning electron microscope revealed that MSLA (control group) surface was not as rough as LT, LAT surface (test groups). Alkaline phosphatase expression, the measure of osteoblastic differentiation, and total ALP expression by surface-adherent cells were found to be highest at 21 days for all three surfaces tested (P<.05). Furthermore, ALP expression levels of MSLA and LAT surfaces were significantly higher than expression levels of LT surface-adherent cells at 7, 14, and 21 days, respectively (P<.05). However, ALP expression levels between MSLA and LAT surface were equal at 7, 14, and 21 days (P>.05). CONCLUSION. This study suggested that MSLA and LAT surfaces exhibited more favorable environment for osteoblast differentiation when compared with LT surface, the results that are important for implant surface modification studies.

Improvement in Tribological Properties of Carbon Steel Sintered by Powder Metallurgy (분말 야금에 의해 소결된 강철의 트라이볼로지 특성 향상)

  • Choi, S.I.M.;Karimbaev, R.;Pyun, Y.S.;Amanov, A.
    • Tribology and Lubricants
    • /
    • v.36 no.4
    • /
    • pp.244-252
    • /
    • 2020
  • Materials manufactured by powder metallurgy (PM) are widely used in various applications such as water pump, shock absorber, and airplane components due to the reduction in the cost and weight. In this study, tribological properties of carbon steel subjected by surface treatment were investigated. The main purpose is to increase the strength and improve the tribological properties by reducing pores that formed by PM. Moreover, the surface treatment was carried out at room and high temperatures (RT and HT). The surface roughness of the untreated (NON) and treated (AFTER) samples was measured. It was found that the surface roughness was reduced after both the RT AFTER and HT AFTER compared to RT NON sample. The tribological properties of the samples were performed against bearing steel ball under dry conditions. The friction coefficient of the RT NON samples was reduced by 22% and 56% RT AFTER and HT AFTER, respectively. The wear volume of the RT NON sample was also reduced by 43% and 87% RT AFTER and HT AFTER, respectively. Tribocorrosion tests were also performed and it was found that the surface of the RT AFTER, HT AFTER samples was less corroded compared to RT NON sample. The HT AFTER sample demonstrated a relatively higher corrosion potential in comparison with the RT AFTER samples. Hence, it was confirmed that after surface modification the surface roughness and hardness of the samples were significantly improved resulting in improvement in tribological and tribocorrosion behaviors of PM carbon steel.

Comparison on the Physical & Chemical Characteristics in Surface of Polished Wafer and Epi-Layer Wafer (Polished Wafer와 Epi-Layer Wafer의 표면 처리에 따른 표면 화학적/물리적 특성)

  • Kim, Jin-Seo;Seo, Hyungtak
    • Korean Journal of Materials Research
    • /
    • v.24 no.12
    • /
    • pp.682-688
    • /
    • 2014
  • Physical and chemical changes in a polished wafer and in $2.5{\mu}m$ & $4{\mu}m$ epitaxially grown Si layer wafers (Epilayer wafer) after surface treatment were investigated. We characterized the influence of surface treatment on wafer properties such as surface roughness and the chemical composition and bonds. After each surface treatment, the physical change of the wafer surface was evaluated by atomic force microscopy to confirm the surface morphology and roughness. In addition, chemical changes in the wafer surface were studied by X-ray photoemission spectroscopy measurement. Changes in the chemical composition were confirmed before and after the surface treatment. By combined analysis of the physical and chemical changes, we found that diluted hydrofluoric acid treatment is more effective than buffered oxide etching for $SiO_2$ removal in both polished and Epi-Layer wafers; however, the etch rate and the surface roughness in the given treatment are different among the polished $2.5{\mu}m$ and $4{\mu}m$ Epi-layer wafers in spite of the identical bulk structural properties of these wafers. This study therefore suggests that independent surface treatment optimization is required for each wafer type, $2.5{\mu}m$ and $4{\mu}m$, due to the meaningful differences in the initial surface chemical and physical properties.

Influence of Inductively Coupled Plasma on Surface Properties of Polycarbonate (유도 결합형 저온 플라즈마 처리에 따른 폴리카보네이트 표면 특성 변화)

  • Won, Dong Su;Lee, Won Gyu
    • Korean Chemical Engineering Research
    • /
    • v.48 no.3
    • /
    • pp.355-358
    • /
    • 2010
  • Inductively coupled low temperature plasmas with oxygen, argon, mixture of oxygen and argon, and nitrogen have been used to modify polycarbonate(PC) films at the various process conditions. All plasma treatments generally had a tendency to increase the surface roughness of PC regardless of process conditions. The treatment of oxygen plasma showed the highest value in the surface roughness and mostly enhanced the generation of oxygen containing polar groups as much as 43% in comparison of untreated PC. The contact angle of untreated PC decreased from $82.31^{\circ}$ to the lowest value of $9.17^{\circ}$ after oxygen plasma treatment. The increase of RF delivered power had an effect on the rapid reduction of contact angle, but gas flow rates did not effect to reduce contact angles so much.

Comparison of Marginal Fitness of Zirconia Copings According to Impression Techniques and Zirconia Blocks (구강인기방법과 블록 종류에 따른 지르코니아 코핑의 변연적합도 비교)

  • Chung, In-Sung;Jeon, Byung-Wook;Kim, Won-Young
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.151-157
    • /
    • 2016
  • The purpose of this study was to compare of marginal fitness of zirconia copings according to impression techniques and zirconia blocks. For the conventional impression, two types of rubber impression materials were used and digital impression was made by using an intraoral scanner. Zirconia copings were manufactured from three types of blocks. With each of ten zirconia copings was determined by surface roughness and marginal fitness. For surface roughness, LUXEN Smile($2.3{\pm}0.9{\mu}m$) block was superior. And the lowest mean values and standard deviations of marginal gap for the HL specimens were $26.5{\pm}2.1{\mu}m$ for buccal, $27.2{\pm}2.1{\mu}m$ for lingual, and that of the HJ specimens $29.6{\pm}4.0{\mu}m$ for mesial, $29.0{\pm}3.0{\mu}m$ for distal. One-way ANOVA showed statistically significant difference between groups for marginal fitness(p<0.05). From the above results, the impression techniques and zirconia blocks had influence on marginal fit of the zirconia copings. Also the marginal fitness of all groups showed clinically acceptable range.

Estimation of Actual Evapotranspiration using Multi-Satellite Data over Korea Peninsula (다중 위성 자료를 이용한 한반도에서의 실제 증발산량 산출에 관한 연구)

  • Lee, Min-Ji;Han, Kyung-Soo;Kim, In-Hwan
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.19 no.4
    • /
    • pp.145-151
    • /
    • 2011
  • Evapotranspiration (ET) is an important process acrossa wide range of disciplines, including ecology, hydrology and meteorology.In this study, daily actual evapotranspiration (ETa) is based energy balance equation and considering high surface roughness length to estimate. This study was used variety of satellite data and ground observation data in Korea Peninsula from 1 January to 31 December 2009. In this study, sensible heat flux is one of the important parameters of ETa. Measurements of sensible heat flux are, however, complex and can't be easily obtained. So this study was used an empirical coefficient B to simplify estimate of sensible heat flux. The coefficient B in the ETa model requires a careful definition of aerodynamic resistance. So this study proposed ETa model considering aerodynamic resistance and high surface roughness length. This study was conducted validation in comparison of the proposed daily ETa results with Priestley-Taylor ETp.

Characterizations of i-a-Si:H and p-a-SiC:H Film using ICP-CVD Method to the Fabrication of Large-area Heterojunction Silicon Solar Cells

  • Jeong, Chae-Hwan;Jeon, Min-Sung;Kamisako, Koichi
    • Transactions on Electrical and Electronic Materials
    • /
    • v.9 no.2
    • /
    • pp.73-78
    • /
    • 2008
  • We investigated for comparison of large-area i-a-Si:H and p-a-SiC:H film quality like thickness uniformity, optical bandgap and surface roughness using both ICP-CVD and PECVD on the large-area substrate(diameter of 100 mm). As a whole, films using ICP-CVD could be achieved much uniform thickness and bandgap of that using PECVD. For i-a-Si:H films, its uniformity of thickness and optical bandgap were 2.8 % and 0.38 %, respectively. Also, thickness and optical bandgap of p-a-SiC:H films using ICP-CVD could be obtained at 1.8 % and 0.3 %, respectively. In case of surface roughness, average surface roughness (below 5 nm) of ICP-CVD film could be much better than that (below 30 nm) of PECVD film. HIT solar cell with 2 wt%-AZO/p-a-SiC:H/i-a-Si:H/c-Si/Ag structure was fabricated and characterized with diameter of 152.3 mm in this large-area ICP-CVD system. Conversion efficiency of 9.123 % was achieved with a practical area of $100\;mm\;{\times}\;100\;mm$, which can show the potential to fabrication of the large-area solar cell using ICP-CVD method.

The effects of tetracycline-HCI on SLA implant surface structure (염산 테트라싸이클린이 SLA 임플란트의 표면 구조에 미치는 영향)

  • Sea, Mi-Ran;Kwon, Young-Hyuk;Park, Joon-Bong;Herr, Yeek;Chung, Jong-Hyuk
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.2
    • /
    • pp.251-263
    • /
    • 2007
  • The present study was performed to evaluate the effects of Tetracycline-HCI on the microstructure change of SLA implant surface according to application time. In the Tetracycline-HCI group, 6 implants were rubbed with sponges soaked $50mg/m{\ell}$ Tetracycline-HCI solution for O.5min., lmin., 1. 5min., 2min., 2.5min. and 3min. In the saline group. another 6 implants conditioned with sponges soaked saline using same methods. One implant wasn't conditioned anything. Then, the changes of surface roughness values were evaluated by optical interferometer & specimens were processed for scanning electron microscopic observation. The results of this study were as follows: 1. In both Tetracycline-HCI group & saline group, there are no significant differences between surface roughness values before & after surface detoxification. And in scanning electron microscopic observation. there are slightly changes of implant surface structures but this changes were not significant by comparison with no treatment implant surface. 2. In the changes of surface roughness values & the scanning electron microscopic observation, there were no significant differences between saline & Tetracycline-HCI groups. In conclusion, the detoxification with $50mg/m{\ell}$ Tetracycline-HCI within 3 minutes can be applied for treatment of peri-implantitis in SLA surface implants. without surface microstructure changes.