• 제목/요약/키워드: Rough surfaces

검색결과 274건 처리시간 0.022초

Gluconacetobacter persimmonis sp. nov., Isolated from Korean Traditional Persimmon Vinegar

  • Yeo, Soo-Hwan;Lee, Oh-Seuk;Lee, In-Seon;Kim, Hyun-Soo;Yu, Tae-Shick;Jeong, Yong-Jin
    • Journal of Microbiology and Biotechnology
    • /
    • 제14권2호
    • /
    • pp.276-283
    • /
    • 2004
  • Screening was performed to isolate cellulose-producing microorganisms from the Korean traditional fermented persimmon vinegar. The resulting strain, KJ $145^{T}$, was then taxonomically investigated by phenotypic characterization, particularly chemotaxonomic, and by phylogenetic inference based on a 16S rDNA sequence analysis including other related taxa. Strain KJ $145^{T}$ was found to grow rapidly and form pale white colonies with smooth to rough surfaces on a GYC agar. Strain KJ $145^T$ also produced acetate from ethanol, and was tolerable to 10% ethanol in SM medium. In a static culture, a thick cellulose pellicle was produced, and in GYC broth, the strain grew at temperatures ranging from 28 to $40^\circ{C}$ with an optimum pH of 4.0. The genomic DNA G+C content of strain KJ $145^T$ was 61.9 mol%, and the predominant ubiquinone was Q 10 as the major quinone and Q9 as the minor quinone. The major cellular fatty acids were $C_{16:0}$ and the sum in feature 7 ($C_{18:1}$ w9c, w12t and/or w7c). A 16S rRNA-targeted oligonucleotide probe specific for strain KJ $145^T$was constructed, and the phylogenetic position of the new species was derived from a 16S rDNA-based tree. When comparing the 16S rDNA nucleotide sequences, strain KJ $145^T$ was found to be most closely related to G. hansenii LMG $1527^T$ (99.2%), although KJ $145^T$ was still distinct from G. hansenii LMG $l527^T$ and G. xylinus LMG $1515^T$ in certain phenotypic characteristics. Therefore, on the basis of 16S rDNA sequences and taxonomic characteristics, it is proposed that strain KJ $145^T$ should be placed in the genus Gluconacetobacter as a new species, Gluconacetobacter persimmonis sp. nov., under the type-strain KJ $145^T$ (=KCTC =$10175BP^T$=KCCM=$10354^T$).

광학(光學) 및 전자현미경기술(電子顯微鏡技術)에 의(依)한 Mycoplasma pneumoniae의 분열(分裂)과 연속분화(連續分化)에 관(關)한 연구(硏究) (Replication and Sequential Development of Adherent Mycoplasma Pneumoniae Studied by Light and Electron Microscopies)

  • 김치경
    • Applied Microscopy
    • /
    • 제12권2호
    • /
    • pp.11-22
    • /
    • 1982
  • Mycoplasma pneumoniae의 형태적(形態的) 분화과정(分化過程)을 광학(光學) 및 Carbon replication과 critical point drying 전자현미경 기술(技術)을 이용하여 관찰(觀察)하였다. 단세포(單細胞)로 부터 시작하는 전분화(全分化) 과정에서 이 세균(細菌)은 구형(球形)과 방추형(紡錘形)의 세포형태(細胞形態)로 특유(特有)한 분화(分化)를 하며 이 과정은 배양액(培養液)의 pH변화(變化)와 일치(一致)하여 진행(進行)되었다. 본(本) 연구(硏究) 결과(結果)로 부터 M. pneumoniae의 단세포(單細胞)에서 시작되는 새로운 생활회로(生活回路)를 다음과 같이 제기(提起)하였다. 단세포기(單細胞期)를 지나 제1분열기(第1分裂期)에는 구형세포(球形細胞)가 주로 대수증식기(對數增殖期)의 초기에 이분법(二分法)에 의하여 분열하고 그 후에 방추형 세포(細胞)가 분절법(分節法)에 의하여 분열하는 제2분열기(第2分裂期)가 뒤 따른다. 방추형(紡錘形)의 긴 세포(細胞)는 극성(極性)을 갖고 세포 한쪽 끝으로 부터 성장(成長)하여 수 많은 방추형세포에 의한 망상기(網狀期)가 된다. 이와 같은 생장회로(生長回路)는 좋은 생장(生長) 환경에서는 반복되지만 pH가 6.8 이하로 떨어지거나 다른 조건(條件)들이 나빠지면 세포표면(細胞表面)이 조악(粗惡)한 구형(球形)으로 변형(變形)되어 사멸기(死滅期)에 들어가 모든 세포(細胞)는 생명력(生命力)을 상실하게 된다.

  • PDF

폴리카보네이트/폴리(부틸렌 테레프탈레이트) 블렌드의 유변학적 및 파괴특성 (Rheological and Failure Properties of Polycarbonate/Poly(butylene terephthalate) Blends)

  • 나창운;허몽영;최대환;국정호;황인라;정광운;홍창국
    • 폴리머
    • /
    • 제31권5호
    • /
    • pp.399-403
    • /
    • 2007
  • 폴리카보네이트/폴리(부틸렌 테레프탈레이트)(PC/PBT) 블렌드에 대해 용융혼합 과정에서 에스테르 교환반응 거동을 조사하였고, PC/PBT 혼합비에 따른 유변학적 특성, 파괴거동 및 파단면 모폴로지를 조사하였다. FT-IR 및 $^1H-NMR$ 분석을 통해 용융혼합 중에 PC와 PBT간 에스테르화 반응이 일어남을 확인하였다. PC 함량이 증가할수록 용융지수(MI)는 감소하여 PC의 높은 흐름저항성을 확인하였다. 또한 PC 함량이 증가할수록 저장 및 손실 탄성률은 증가하였고, Cole-Cole 도시로부터 PC/PBT 블렌드의 경우 혼합비에 관계없이 유변학적 상용성은 나타내지 않은 것으로 나타났다. 인장강도는 PC 함량이 증가함에 따라 선형적인 증가를 나타내었다. 충격강도의 경우 PC 함량이 증가함에 따라 증가하였는데, 약 $30{\sim}40wt%$ 범위에서 가장 급격한 증가폭을 나타내었고, 50 wt% 이상의 범위에서는 거의 일정한 값을 나타내었다. 충격 파단면을 관찰한 결과 약 40 wt% 이상의 범위에서부터 충격방향으로 거친 파괴 릿지(ridge)가 형성되어서 높은 충격강도를 나타낸 것으로 판단된다.

질화 지르코늄 코팅이 코발트 크롬 합금과 타이타늄 합금에서 의치상 레진과의 전단결합강도에 미치는 영향 (The effect of Zirconium Nitride coating on shear bond strength with denture base resin in Co-Cr alloy and titanium alloy)

  • 박찬;이경훈;임현필
    • 구강회복응용과학지
    • /
    • 제32권3호
    • /
    • pp.194-201
    • /
    • 2016
  • 목적: 본 연구는 Co-Cr, Ti-6Al-4V 합금에 Zirconium Nitride (이하 ZrN) 적용 시, 의치상 레진과의 접착력을 비교하는 것이다. 연구 재료 및 방법: Co-Cr, Ti-6Al-4V 디스크(직경 10 mm, 두께 2.5 mm)를 각각 14개씩 제작하였고, ZrN 코팅에 따라 2개의 그룹으로 나누었다. Primer로 시편 전처리 후, 의치상 레진(직경 6 mm, 두께 5 mm)을 부착하였다. 표면 측정기를 이용하여 시편의 거칠기를 측정한 후, 만능 시험기를 이용하여 전단결합강도를 측정하였으며, 이원분산분석으로 통계 분석하였다. 시편 표면과 파절 양상을 주사전자현미경을 이용하여 관찰하였다. 결과: ZrN을 코팅한 시편에서 유의하게 높은 표면 거칠기를 나타내었고(P < 0.05), 전단결합강도는 낮았다(P < 0.001). ZrN 코팅 시편에서는 혼합성 파절과 부착성 파절이 함께 나타났다. 결론: Co-Cr, Ti-6Al-4V 합금에서 ZrN 코팅 처리는 의치상 레진과의 결합력을 약화시켰다.

짧은 길이의 거친 표면 임프란트에 대한 후향적 연구 (RETROSPECTIVE STUDY OF SHORT ROUGH SURFACE IMPLANTS)

  • 공준하;이백수;김여갑;권용대;윤병욱;최병준
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제31권1호
    • /
    • pp.41-45
    • /
    • 2009
  • Background: Reduced bone height is one of the major problems faced in restoring tooth loss with implants. By the use of short implants, it is possible to reduce complicated and invasive treatment such as bone graft, allowing more simple surgery. But short implants are generally considered to have lower success rates than that of standard implants. Purpose: To assess the results of short Straumann implants by a retrospective study of short Straumann implants with TPS(titanium plasma-sprayed) and SLA(sandblasted, large grit, acid etched) surfaces. Materials and methods: 173 implants in 106 patients who received short Straumann implant surgery(${\le}8\;mm$) in the department of oral and maxillofacial surgery, Kyunghee Dental Hospital, from February 1996 to October 2006 were selected and studied. All of the implants were followed up after prosthetic rehabilitation. The average follow-up period was 34 months with 119 months as the longest follow up period. The average follow-up period after prosthetic rehabilitation was 31 months. 64 females(60.4%) and 42 males(39.6%) participated in the research with the age range of 19 to 85(mean age 47). 20 patients(18.9%) were under 40, 85 patients(80.2%) were over 40 and under 70, and only one patient(0.9%) was over 70 years old. Results: 27 implants(15.6%) had TPS surface while 146 implants(84.4%) had SLA surface. 9 implants(5.2%) were 3.3, 108 implans(62.4%) were 4.1mm and 56 implants(32.4%) were 4.8mm in diameter. 167 implants(96.5%) were 8mm and 6 implants(3.5%) were 6mm in length. There were 24 implants(13.9%) on the maxillas and 149 implants(68.8%) on the mandibles. 119 implants(68.8%) were rehabilitated with FPD(fixed partial denture), 47 implants(27.2%) with single crowns and 4 implants(2.3%) with overdentures. Among the fixed partial dentures, 30 of them were splinted with short implants only. After over an year of follow-up period, 139 implants(96.5%) out of 144 implants showed marginal bone loss of less than 1mm. 3 out of 173 implants failed showing 98.27% survival rate. Conclusions: The use of short Straumann implants(${\le}8mm$) can be a simple and reliable treatment method in minimal residual bone height.

Glass ionomer cement 표면의 산부식 효과에 관한 연구 (THE EFFECT OF ACID ETCHING ON GLASS IONOMER CEMENT SURFACES)

  • 한승원;박상진;민병순;최호영;최기운
    • Restorative Dentistry and Endodontics
    • /
    • 제18권1호
    • /
    • pp.1-26
    • /
    • 1993
  • The purpose of this study was to investigate the effect of acid etching on the surface appearance and fracture toughness of five glass ionomer cements. Five kinds of commercially available glass ionomer cements including chemical curing filling type, chemical curing lining type, chemical curing metal reinforced type, light curing tilling type and light curing lining type were used for this study. The specimens for SEM study were fabricated by treating each glass ionomer cement with either visible light curing or self curing after being inserted into a rubber mold (diameter 4mm, depth 1mm). Some of the specimens were etched with 37% phosphoric acid for 0, 15, 30, 60, go seconds, at 5 minutes, 1 hour and 1 day after mixing of powder and liquid. Unetched ones comprised the control group and the others were the experimental groups. The surface texture was examined by using scanning electron microscope at 20 kV. (S-2300, Hitachi Co., Japan). The specimens for fracture toughness were fabricated by curing of each glass ionomer cement previously inserted into a metal mold for the single edge notch specimen according to the ASTME399. They were subjected to a three-point bend test after etching for 0, 30, 60, and 90 seconds at 5 minutes-, 1 hour-and 1 day-lapse after the fabrication of the specimens. The plane strain fracture toughness ($K_{IC}$) was determined by three-point bend test which was conducted with cross-head speed of 0.5 mm/min using Instron universal testing machine (Model No. 1122) following seven days storage of the etched specimens under $37^{\circ}C$, 100% humidity condition. Following conclusions were drawn. 1. In unetched control group, crack was present, but the surface was generally smooth. 2. Deterioration of the surface appearance such as serious dissolving of gel matrix and loss of glass particles occured as the etching time was increased beyond 15 s following Immediate etching of chemical curing type of glass ionomer cements. 3. Etching after 1 h, and 1 d reduced surface damage, 15 s, and 30s etch gave rough surface appearance without loss of glass particle of chemical curing type of glass ionomer cements. 4. Light curing type glass ionomer cement was etched by acid, but there was no difference in surface appearances according to various waiting periods. 5. It was found that the value of plane stram fracture toughness of glass ionomer cements was highest in the light curing filling type as $1.79\;MNm^{-1.5}$ followed by the light curing lining type, chemical curing metal reinforced type, chemical curing filling type and chemical curing lining type. 6. The value of plane stram fracture toughness of the chemical curing lining type glass ionomer cement etched after 5 minutes was lower than those of the cement etched after 1 hour or day or unetched (P < 0.05). 7. Light curing glass ionomer cement showed Irregular fractured surface and chemical curing cement showed smooth fractured surface.

  • PDF

MOCVD에 의한 Ti 금속 기판 위의 비정질 Ga2O3 박막 형성과 다이오드 특성 (Formation of amorphous Ga2O3 thin films on Ti metal substrates by MOCVD and characteristics of diodes)

  • 안남준;안장범;안형수;김경화;양민
    • 한국결정성장학회지
    • /
    • 제33권4호
    • /
    • pp.125-131
    • /
    • 2023
  • Ga2O3 박막은 금속 유기 화학기상증착법을 사용하여 Ti 기판에 350~500℃ 범위의 비교적 낮은 온도로 증착되었다. 낮은 온도를 선택하여 Ti 기판의 열적 변형과 Ga2O3 박막에 미치는 영향을 최소화하였다. 500℃ 이하에서 박막 형성 시, 기판 표면에서 원자들의 확산에너지가 충분하지 못하여 박막 표면이 3차원 성장으로 인해 거칠어지는 경향을 보였다. 그러나 500℃에서 형성된 박막은 2차원 박막 형태로 형성되었으며 비교적 균일한 표면을 가지고 있음을 확인하였다. 모든 증착된 박막은 비정질 구조였다. Ti 금속 기판 위에 형성된 Ga2O3 박막 위에 금속 전극을 형성하여 수직 쇼트키 다이오드를 제작하였으며, 제작된 다이오드의 전류-전압(I-V) 및 캐패시턴스-전압(C-V) 특성을 평가하였다. I-V 측정 결과, 대부분의 다이오드 소자에서 매우 높은 동작 전압을 나타냈으며, 비교적 균일한 표면을 갖는 500℃에서 성장한 샘플은 가장 낮은 동작 전압을 가짐을 확인할 수 있었다. 또한, C-V 측정 결과, 박막의 성장 온도가 높을수록 커패시턴스 값이 증가하는 것을 확인할 수 있었다.

Effect of Liquefied Digestive Medicine on the Surface of Composite Resin

  • Kim, Min-Young;Lim, Hee-Jung;Kim, Ha-Eun;Kim, Hyun-Jeong;Yu, Hye-Kang;Choi, Soo-Jin;Lim, Do-Seon
    • 치위생과학회지
    • /
    • 제22권1호
    • /
    • pp.20-29
    • /
    • 2022
  • Background: The purpose of this study is to investigate the effect of liquefied digestive medicines on the composite resin surface. Methods: Three types of liquefied digestive medicines (Gashwalmyeongsu, Wicheongsu, and Saengrokcheon) were selected as experimental groups, Samdasoo and Chamisul as negative controls, and Trevi as positive controls were selected to measure pH and titratable acidity. The samples filled with resin at acrylic were made total 300, 50 per group. To evaluate the erosion risk of the composite resin, the specimens were immersed in a liquefied medicine for 1, 3, 5, 15, and 30 minutes, and then the surface microhardness was measured using the Vickers Hardness Number, and the surface change was observed with scanning electron microscope (SEM). Results: The average pH of the three liquefied medicine was 3.75±0.30, the Saengrokcheon was the lowest at 3.45±0.01, and the Trevi was 4.66 and Samdasoo and Chamisul were 7.40 and 8.58, respectively. The amount of NaOH reaching pH 5.5 and 7.0 was the lowest in the order of Trevi, Gashwalmyeongsu, Wicheongsu, and Saengrokcheon. The largest surface hardness reduction value was shown in Gashwalmyeongsu (-11.85±3.73), followed by Saengrokcheon (-9.79±3.11) and Wicheongsu (-8.28±2.83), and Samdasoo (-0.84±1.56) and Chamisul (-6.24±0.42) had relatively low surface hardness reduction values. However, Trevi (-16.67±5.41), a positive control group containing carbonic acid, showed a higher decrease in surface hardness than the experimental group. As a result of observation with SEM, experimental group and positive control group, showed rough surfaces and irregular cracks, and negative control groups showed smooth patterns similar to before immersion. Conclusion: The liquefied digestive medicine with low pH could weaken the composite resin surface, and the carbonic acid component could more effect on the physical properties of the composite resin than pH.

Titanium plasma sprayed implant에 관한 여러가지 기계적 표면처리방법이 implant표면조도에 미치는 영향 (EFFECT OF VARIOUS MECHANICAL TREATMENTS ON TITANIUM PLASMA SPRAYED IMPLANT SURFACES)

  • 유현석;박재완;서조영
    • Journal of Periodontal and Implant Science
    • /
    • 제23권3호
    • /
    • pp.493-506
    • /
    • 1993
  • 실패한 임프란트를 구강내에 유지하기 위하여는 임프란트 매식체의 표면을 처치하여 세균독소를 제거하구 주위의 연, 경조직에 적합한 표면 구조를 만들어 주어야 한다. 이에 본 연구에서는 임프란트 매식체 표면을 high speed diamond bur, low speed diamond bur, stone, rubber point, Jetpolisher로 처치하여 가장 평활한 표면을 만들 수 있는 방법을 알아 보았다. 조도측정기를 이용하여 표면의 최대높이값을 측정한 결과 high speed diamond bur, rubber point, Jetpolisher를 사용한 시편의 최대높이값의 평균은 $7.77{\mu}m$였고, low speed diamond bur, rubber point, Jetpolisher를 사용한 경우에는 $8.44{\mu}m$를 보였다. Stone, rubber point, Jetpolisher를 사용한 경우 $6.24{\mu}m$로 가장 평활한 표면을 보였다. 이러한 수치들은 제거하지 않은 TPS(titanium plasma sprayed)면의 $24.43{\mu}m$에 비하여는 낮은 수치를 보였다. 주사전자현미경으로 관찰 하였을 때 high speed diamond bur, rubber point, Jetpolisher를 사용한 군에서는 TPS 입자들이 부분적으로 남아있었으나 이 입자들은 그 높이가 원래의 TPS에 비하여는 상당히 감소되어 있었다. Low speed diamond bur, rubber point, Jetpolisher를 사용한 시편에서는 전 표면에 걸쳐 TPS가 남아있는 거친 표면 구조를 보였다. Stone, rubber point, Jetpolisher를 사용한 시편은 대부분의 TPS가 제거되어 titanium이 노출되어 있었고, titanium 금속에 stone에 의한 흠들이 보였으나 일부분에서는 TPS가 남아있어 제조회사에서 만들어진 평활한 표면에 비해서는 거친 양상을 보였다.

  • PDF

코팅된 지대주 나사의 반복 착탈 후 풀림력과 표면변화에 대한 연구 (Detorque force and surface change of coated abutment screw after repeated closing and opening)

  • 장종석;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제46권5호
    • /
    • pp.500-510
    • /
    • 2008
  • 연구목적: 최근 지대주 나사에 WC/C 또는 TiN 코팅이 연구되고 있으며, 이들을 금속표면에 코팅 시 마찰계수의 감소와 부식에 대한 저항, 물리적 취약함의 해소 등의 효과를 얻을 수 있으며. 코팅된 지대주 나사에서 마모와 적합도, 풀림력이 향상되었다는 결과들이 보고되고 있다. 본 연구에서는 지대주 나사에 적용된 코팅이 나사 풀림에 미치는 영향을 알아보아 임상적으로 문제가 되고 있는 지대주 나사의 풀림현상을 해소하는데 그 목적이 있다. 연구재료 및 방법: 코팅되지 않은 타이타늄 지대주 나사와 (그룹 A) WC/C (그룹 B)와 TiN (그룹 C)으로 코팅된 지대주 나사의 10회 반복 착탈시 풀림력 및 표면의 변화를 비교해본 결과 다음과 같은 결론을 얻었다. 결과: 1. 반복 착탈 전, 그룹 A는 일정한 방향성을 가진 다소 거친 표면이 관찰되었으 나 그룹 B와 그룹 C는 코팅된 입자들이 관찰되었으며 코팅층이 전체적으로 균일하고 매끈한 모양을 나타내었다. 2. 반복 착탈 전, 그룹 B에 비해 그룹 C의 표면에서 코팅 입자의 크기가 더 크고 두껍게 코팅 된 모양을 나타내었다. 3. 반복 착탈 후, 그룹 A와 그룹 B에서는 지대주 나사 표면의 마모와 변형이 관찰 되었으며 그룹 B에서는 코팅 입자의 탈락 현상을 볼 수 있었다. 4. 반복 착탈 전과 후의 지대주 나사 무게의 변화를 측정한 결과 그룹 A가 가장 큰 감소를 보였으며, 그룹 C가 그룹 B 보다 무게의 변화가 적었으나 두 그룹간 통계적으로 유의한 차이는 없었다. 5. 그룹 B와 그룹 C는 그룹 A에 비해 높은 평균 풀림력을 나타내었고 통계학적으로 유의할 만한 차이가 있었다. 6. 그룹 A에서 그룹B 와 그룹 C보다 평균 풀림력의 감소 경향이 더욱 현저 하게 나타났다. 결론: 결론적으로, WC/C 또는 TiN 코팅된 지대주 나사는 반복적인 사용 후에도 코팅되지 않은 타이타늄 지대주 나사에 비해 뚜렷한 표면 변화를 보이지 않았으며 마모에 대한 저항성이 우수하였고 높은 풀림력을 나타내었다. 따라서 지대주 나사에 WC/C 또는 TiN 코팅을 적용 시 나사 풀림의 문제점을 개선할 수 있을 것으로 사료된다.