• Title/Summary/Keyword: Rotation-plasty

Search Result 9, Processing Time 0.023 seconds

A Case Study of Prosthetic Ambulation Training for Rotation-Plasty Client (하지 분절절제 및 회전재접합술자의 의지 보행훈련 증례연구)

  • Lee, Jeong-Weon;Chung, Nack-Su
    • Physical Therapy Korea
    • /
    • v.3 no.1
    • /
    • pp.65-72
    • /
    • 1996
  • The purpose of this study was to introduce rotation-plasty procedure and prosthetic ambulation training. The recent development of chemotherapy and diagnostic facility have permitted the orthopaedic surgeons to try limb saving procedures rather than amputations for the treatment of the malignant bone tumors. If the tumors around the knee joint were treated by mid-thigh amputation or hip disarticulation, it would impose the client with a great handicap for rehabilitation. Rotation-plasty procedure was first done by Borggreve, in 1930 for the congenital short femur. Recently this procedure was used a malignant bone tumor at the distal femur by Kotz and Salzer in 1982. In spite of its cosmetic problem of the distal stump, this procedure has the great functional advantage of converting the above-knee amputation to the below-knee amputation. The inverted foot was also good to control the prosthesis as a below-knee stump and heel functioned as a patella to support the body weight. This 15 years old girl case was had rotation-plasty due to osteosarcoma of the distal femur with 3rd postoperative chemotherapy, and admitted to Yonsei rehabilitation hospital for prosthetic ambulation training. Then, the case had excellent functional results of prosthetic ambulation training with rotaion-plasty after 3 months.

  • PDF

Repair of Unilateral Cleft Lip and Nose: Mulliken's Modification of Rotation Advancement (편측 구순열비의 교정술: Rotation Advancement 원칙에 근거한 Mulliken의 방법)

  • Jung, Young-Soo;Lee, Gyu-Tae;Jung, Hwi-Dong;Mulliken, John B.
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.2
    • /
    • pp.133-139
    • /
    • 2012
  • This is a review regarding Mulliken's Modification using the Millard rotation-advancement principle for the repair of unilateral complete cleft lip and nasal deformity. All patients underwent prior labionasal adhesion and dentofacial orthopedics with a pin-retained (Latham) appliance used for infants with a cleft of the lip and palate. Technical variations concerning the operation are described. A high rotation and releasing incision in the columella lengthens the medial labial element and produces a symmetric prolabium with minimal transgression of the upper philtral column through the advancement flap. The orbicularis oris muscle is everted, from caudad to cephalad, to form the philtral ridge. A minor variation of unilimb Z-plasty is used to level the cleft side of Cupid's bow handle, and cutaneous closure proceeds superiorly from this junction. The dislocated alar cartilage is visualized though a nostril rim incision and suspended to the ipsilateral upper lateral cartilage. Symmetry of the alar base is addressed in three dimensions, including maneuvers to position the deviated anterior-caudal septum, configure the sill, and efface the lateral vestibular web. The authors believe the technical refinements described herein contribute favorably to the outcome of repair regarding unilateral cleft lip and nasal distortion.

Nasal tip plasty using three-dimensional printed polycaprolactone (Smart Ball®)

  • Kim, Joo Hyoung;Kim, Geon Woo;Kang, Won Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.1
    • /
    • pp.32-39
    • /
    • 2020
  • Background: Rhinoplasty is one of the most commonly performed cosmetic surgery procedures. Most Asians desire elevation of their relatively flat nasal dorsum and tip to make them appear more prominent. This study introduces a simple method of nasal tip plasty using three-dimensional (3D)-printed polycaprolactone (PCL) (Smart Ball®), which provides the required length and volume for this purpose and enables the creation of a nasal tip of the desired shape in a safe and simple manner. Methods: Between September 2014 and May 2017, 22 patients participated in a survey to assess postoperative satisfaction levels. Additionally, three plastic surgeons compared patients' pre- and 1-year postoperative photographs to evaluate the results. All patients underwent 2- to 4-year postoperative follow-up. Results: Levels of subjective satisfaction among patients were 3.59, 3.50, 3.82, 3.73, 3.55, and 3.82 for each of the 6 categories evaluated, with a mean of 3.67/4 points, indicating high satisfaction levels. The mean plastic surgeon-reported score for the 22 patients was 4.47/5 points, which also indicates highly successful outcomes. Postoperative nasal tip rotation and tip projection were ideal in most patients. Conclusion: Our novel method using 3D-printed PCL (Smart Ball®) provides the optimal length and volume required for nasal tip plasty and enables the creation of a nasal tip of the desired shape, in a safe and simple manner. An advantage of our method is that it retains the original nasal structure in contrast to structural changes observed with the use of conventional methods.

L-Shaped Columellar Strut in East Asian Nasal Tip Plasty

  • Dhong, Eun-Sang;Kim, Yeon-Jun;Suh, Man Koon
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.616-620
    • /
    • 2013
  • Background Nasal tip support is an essential consideration for rhinoplasty in East Asians. There are many techniques to improve tip projection, and among them, the columellar strut is the most popular technique. However, the conventional design is less supportive for rotating the tip. The amount of harvestable septal cartilage is relatively small in East Asians. For an optimal outcome, we propose an L-shaped design for applying the columellar strut. Methods To evaluate the anthropometric outcomes, the change in nasal tip projection and the columella-labial angle were analyzed by comparing preoperative and postoperative photographs. The anthropometric study group consisted of 25 patients who underwent the same operative technique of an L-shaped strut graft using septal cartilage and were followed up for more than 9 months. Results There were statistically significant differences between the preoperative and postoperative values in the nasal tip projection ratio and columella-labial angle. We did not observe any complications directly related to the L-shaped columellar strut in the anthropometric study group. Conclusions The L-shaped columellar strut has advantages not only in the controlling of tip projection and rotation, but in that it needs a smaller amount of cartilage compared to the conventional septal extension graft. It can therefore be an alternative technique for nasal tip plasty when there is an insufficient amount of harvestable septal cartilage.

SURGICAL CORRECTION OF TORTICOLLIS USING BIPOLAR RELEASE AND Z-PLASTY (Bipolar release와 Z-Plasty를 이용한 선천적 사경증의 치험례)

  • Jeong, Jong-Cheol;Kim, Keon-Jung;Lee, Jeong-Sam;Min, Heung-Ki;Choi, Jae-Sun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.3
    • /
    • pp.388-395
    • /
    • 1996
  • Congenital muscular torticollis(CMT) is a disorder characterized by shortening of at least one of the cervical muscles and tilting of the head to opposite side. The most commonly affected muscle is the sternocleidomastoid muscle. Pathogenesis and etiology of congenital muscular torticollis were not clearly identified, but considered as fetal malposition, birth trauma, vascular accident, heredity, infection and CNS pathology. Untreated congenital muscular torticollis often causes facial asymmetry and This is the rasult of tensional rotation of the face toward affected side. So early treatment may prevent facial and neck asymmetry and limitation of neck movement. There are many treatment methods in CMT, including conservative and operative method, but presently Bipolar release and Z-Plasty of SCM muscle has been introduced when the conservative treatment had failed. The benefits of this method are to preservation of the normal Neck V-contour and improvement of the neck motion. We treated CMT using Bipolar release and Z-plasty in two patients. After that the patients improved on the range of neck motion and maintained the normal V-conture of the neck, so we report two cases of CMT with literatures.

  • PDF

Clinecal Investigation and Acute Complications of Remodelling Plasty of Costochondral Rib Cage For Pectus Excavatum (전흉벽 늑연골의 리모델링 성형술을 이용한 누두흉수술의 임상적 고찰 초기합병증)

  • Her, Keun;Song, Cheol-Min;Jeon, Cheol-Woo;Jang, Won-Ho;Kim, Hyun-Jo;Jeong, Yoon-Seop;Youm, Wook
    • Journal of Chest Surgery
    • /
    • v.35 no.12
    • /
    • pp.882-889
    • /
    • 2002
  • Acute Complications of Remodelling Plasty of Costochondral Rib Cage For Pectus excavatum Recently, Remodelling Plasty of Costochondral Rib Cage has been introduced as an minimally invasive procedure and expanded its application for pectus excavatum. Outcomes and acute complications were reviewed Material and Method: A retrospective survey of 55 patients who underwent Remodelling Plasty of Costochondral Rib Cage from September, 1999 to February, 2002 was conducted to review complications, postoperative treatments, and outcomes. Result: Age ranged from 1 to 27 years(mean 11.4 $\pm$ 7.1). 35(64%) were less than 15-year old and 20(36%) were more than 15-year old. There were 44(80%) Male patients and 11(20%) female patients. Length of hospital stay was 7.8 $\pm$ 2.1 days for less than 15-Y-old group, 10.6 $\pm$ 6.2 days for more than 15-Y-old group(p = 0.042) One substernal bar was inserted in 52 patients and two substernal bars were inserted in 3 patients. As for stabilizer, one lateral side was fastened in 15 patients and both lateral sides were fastened in 6 patients. In the less than 15-Y-old group, 4 patients needed stabilizer, whereas in the more than 15-Y-old group, 18 patients needed stebilizer(s)(p = 0.000). Including all kinds of complications, 28(51 %)patients had postoperative complications. Of them, only 7 patients were treated for complications(C-tube insertion was done in 7 patients and reoperation for bar refixation or removal was done in 3 patients of them). Conclusion: Most complications after Remodelling Plasty of Costochondral Rib Cage For Pectus Excavatum were trivial without treatment although C-tube drainage was needed in some patients. However bar displacement such as rotation and lateral sliding should be corrected as soon as detected in order not to remove the bar(the worst situation).

Optimal harvest and efficient use of septal cartilage in rhinoplasty

  • Yoon, Sung Ho;Kim, Cha Soo;Oh, Jae Wook;Lee, Keun Cheol
    • Archives of Craniofacial Surgery
    • /
    • v.22 no.1
    • /
    • pp.11-16
    • /
    • 2021
  • Background: Nasal septal cartilage is used to obtain favorable aesthetic and functional outcomes in rhinoplasty, but is often difficult to harvest or the harvested amount is insufficient. Therefore, the objective of this study is to introduce how to harvest septal cartilage optimally without losing and use harvested cartilage efficiently. Methods: From March 2015 to January 2020, we tried to harvest as much septal cartilage as possible while maintaining the L-strut in 30 patients. A spreader flap and septal rotation suture were used instead of a spreader graft. Also in patients who needed a spreader graft and septal extension graft, a spreader graft was used on one side and a one-piece spreader graft combined with a septal extension graft was performed on the other side. For tip plasty, a columella septal suture was performed first. Postoperative patient satisfaction was assessed using the Rhinoplasty Outcome Examination questionnaire. Results: No serious complications were observed. The patient satisfaction score was 50% or above in 27 patients (90%) and less than 50% in only three patients (10%). The average score was 81.5 points. Conclusion: For septal cartilage deficiency, a spreader flap, the septal rotation suture, or onepiece spreader graft combined with a septal extension graft was used. The nasal tip was sufficiently rotated using the columellar septal suture technique first. These techniques made it possible to obtain good aesthetic outcomes using only septal cartilage, without harvesting other cartilage.

Shoulder Arthrodesis in Brachial Plexus Injury Patient (상완신경총 손상 환자에서 시행한 견관절고정술)

  • Han, Chung-Soo;Chung, Duke-Whan;Lee, Jae-Hoon;Jeong, Bi-O;Park, Hyun-Chul;Kim, Jin-Young;Song, Jong-Hoon;Seo, Jae-Wan
    • Archives of Reconstructive Microsurgery
    • /
    • v.18 no.2
    • /
    • pp.55-61
    • /
    • 2009
  • Purpose: To analyze the clinical and radiologic results of the shoulder arthrodesis in brachial plexus injury patients with flail upper extremity. Material and Method: From Aug 1978 to April 2008, 29 shoulders in 29 patients with brachial plexus injury with shoulder fusion, we evaluated 20 shoulders in 20 patients, more than 1 year follow up. The average follow-up period was 6.45years (range: 1year~24years). There were 13 men and 7 women, and the mean age at the time of trauma was 32.0years(2~65 years). The type of injury was a motorcycle accident in 11 patients, in car accident in 5, pedestrian accident in 3, and fall from a height in 1. The lesion of injury was root and trunk in 1 patient, trunk and cord in 1, trunk in 18. Surgery was performed on the whole arm type paralysis in 12 patients, lower arm type paralysis in 8 patients. The preoperative visual analog scale score was 8.7(7~10). When the trapezius and serratus anterior muscle were in function, operation was performed. 18 patients were processed to the additional operation. Gracilis free flap in 6 patients, neurotization in 3, Steindler flexor plasty in 6, and tendon transfer in 3 were performed. Fixation was conducted with cancellous screws in 13 patients, Knoles pins in 5, and cancellous screws and Knoles pins in 2. The position of the arthrodesis at operation was $28.5^{\circ}$($20~45^{\circ}$) in abduction, $30.3^{\circ}$($20~45^{\circ}$) in flexion, and $30.8^{\circ}$($20~40^{\circ}$) in internal rotation. Result: The follow up visual analog scale score was 3.4(0~7). Postoperatively, shoulder spica cast was applied for 15.3weeks(8-20weeks). The median time to bony union was 17.7weeks(9~28weeks). Average range of motion was $32.0^{\circ}$($15~40^{\circ}$) of abduction, $24.0^{\circ}$($10~40^{\circ}$) of flexion, and $18.5^{\circ}$($10~30^{\circ}$)of internal rotation. Conclusion: The shoulder fusion in brachial plexus injury patients is one of the good methods to relieve pain, improve the function and stabilize the flail shoulder joint.

  • PDF

Functional Result of Limb Salvage Surgery with Tumor Prosthesis for Osteosarcoma of Proximal Tibia (근위 경골 골육종의 종양대치물을 이용한 사지 구제술 후의 기능 평가)

  • Bahk, Won-Jong;Sohn, Jong-Min;Chung, Yang-Guk;Kang, Yong-Koo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.7 no.4
    • /
    • pp.139-143
    • /
    • 2001
  • Purpose : Limb salvage for osteosarcoma of proximal tibia is challenging problem due to difficulties in mobilizing or retracting the main neurovascular structure, inadequate soft tissue coverage, and unsolved problem of patellar tendon reattachment to endoprosthesis. The authors analyzed the functional result of limb salvage using tumor prosthesis with medial gastrocnemius rotation plasty for osteosarcama of the proximal tibia. Materials and Methods : Eleven patients with histologically proven osteosarcoma of the proximal tibia, treated with adjuvant and neoadjuvant chemotherapy and limb salvage operation with tumor prosthesis between January 1992 and December 1998 at our Medical Center, were selected. There were 6 male and 5 female. Age ranged from 15 years to 23.7 years with an average of 23.7 years. Follow-up period ranged from 1 year to 4.5 years with an average of 2.5 years. The final functional result was evaluated using the method by ISOLS, 1993. The factors include pain, functional activities, emotional acceptance, use of external supports, walking ability and gait. Each of the factors has been scored from 0 to 5 depending on the appropriate description or data. The rating score is determined by dividing the individual factor scores into the total score and indicates percentage of normal function. Results : The overall functional result ranged from 53,3% to 86.7% with an average of 68.3% of normal function. In details, the averages were 82.5% for pain, 62.5% for functional activities, 67.5% for emotional acceptance, 77.5% for use of external supports, 62.5% for walking ability, and 57.5% for gait. The average range of motion of the knee joint was $5^{\circ}$ extension and $85^{\circ}$ flexion. Five patients have extension lag ranged from $5^{\circ}$ to $15^{\circ}$ with an average of $10^{\circ}$. Two patients suffered postoperative infection. One was treated with antibiotics injection only, but the other needed removal of the prosthesis and knee fusion. Both of them showed unsatisfactory result. C o n c l u s i o n : The overall functional result after limb salvage using tumor prosthesis with medial gastrocnemius rotational flap for osteosarcoma of the proximal tibia was relatively satisfactory in case of no postoperative infection. The patients were less satisfactory in functional activities, emotional acceptance and gait than pain, use of external supports due to limitation of motion and extension lag. More aggressive postoperative physical therapy and protection with brace for 6~9 months as well as surgical technique is mandatory for more satisfactory result.

  • PDF