• Title/Summary/Keyword: Rotation Operation

Search Result 388, Processing Time 0.029 seconds

Public Officials' Perceptions on Improving Quality of Community Health Care Service (공무원 인식유형에 따른 보건서비스 개선 방안)

  • Yang, Chang Hoon;Lee, Jei Young
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.1
    • /
    • pp.223-237
    • /
    • 2014
  • The purpose of this study is to understand the perceptions of public officials in improving primary health care service for local communities by applying Q methodology that draw upon schematic model in subjectivity study. A survey was carried out among public officials at Gangneung Community Health Center, South Korea, to classify the 49 selected Q-statements into a normal distribution using a 11 point scale. The collected data was analyzed using QUANL program, and principal component factor analysis using varimax rotation was used to identify public officials' perceptions of improving quality of health care for local communities as a meaningful service provider. Type I can be categorized by a strong concern for the service acceptance, Type II can be categorized by advocating for service usability, Type III can be categorized by the pursuit of service specialization, Type IV can be categorized by roles for service accessibility, and Type V can be categorized by the suggestions for operation and management. The results provide information used to further improve quality of community health care service with the aim to promote the effectiveness of health care delivery and to increase health service utilization.

Experimental Study of Adoption of Alternative Refrigerant for Avionic Equipment Cooling System (항공전자기기용 냉각시스템의 대체냉매 적용에 관한 실험적 연구)

  • Kang, Hoon;Jung, Jongho;Jung, Minwoo;Chi, Yongnam;Yoo, Yongseon;Choi, Heeju;Byeon, Youngman;Kim, Youngjin;Oh, Kwangyoon;Kim, Yongchan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.431-439
    • /
    • 2013
  • A cooling system is adopted to control the thermal load from the avionic equipments in an aircraft for stable operation. In this study, an avionic cooling system was designed and manufactured by adopting a vapor compression cycle with a closed-loop air-circulation system to investigate the operating characteristics of an alternative refrigerant. The performance characteristics of a cooling system adopting R236fa as an alternative refrigerant were experimentally determined by varying the refrigerant charging amount, expansion valve opening, and compressor rotation speed. The experimental results were analyzed and compared with those of a cooling system adopting R124 as a refrigerant. The possibility of the adoption of R236fa as an alternative refrigerant was verified, and design solutions were suggested to improve the system efficiency.

Influence of Aqua and Balance Exercise on Tyrosine Hydroxylase Expression in the Substantia Nigra and Functional Recovery in Hemiparkinsonian Rat Model (수중 및 균형 운동이 파킨슨 유발 백서모델에서 중뇌 흑질의 Tyrosine Hydroxylase 발현과 기능 회복에 미치는 영향)

  • Lee, Hyun-Min;Kim, Bum-Soo
    • Development and Reproduction
    • /
    • v.15 no.2
    • /
    • pp.143-150
    • /
    • 2011
  • The objective of this study was to determine the effect of exercise on a hemiparkinsonian rat model. Nigrostriatal dopamine cell lesions were produced by injecting 6-hydroxydopamine at the left medial forebrain bundle of rats. In this study, the rats were divided into the following 4 groups: the control group without any exercise, experimental group I with aqua-exercise (Exp I), experimental group II with balance exercise (Exp II) and experimental group III with complex exercise (aqua-exercise+balance exercise; (Exp III)). Exercises were applied to all the experimental groups after the operation. In order to observe the dopaminergic cell loss, we assessed the level of tyrosine hydroxylase (TH) expression in the midbrain of rats, and performed the apomorphine-induced rotation test at postoperative days (PDs) 7, 14, and 21. Experimental groups had significantly higher TH-immunoreactivity and behavioral performance than the control group. However, there was no difference in TH-immunoreactivity and behavioral performance across the experimental groups. These results suggest that the application of aqua-exercise and balance exercise could suppress dopaminergic cell loss in the substantia nigra of rat brains and could increase behavioral recovery in hemiparkinsonian rats.

Gyroscope Signal Denoising of Ship's Autopilot using Kalman Filter and Multi-Layer Perceptron (칼만필터와 다층퍼셉트론을 이용한 선박 오토파일럿의 자이로스코프 신호 잡음제거)

  • Kim, Min-Kyu;Kim, Jong-Hwa;Yang, Hyun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.25 no.6
    • /
    • pp.809-818
    • /
    • 2019
  • Since January 1, 2020, the International Maritime Organization (IMO) has put in place strong regulations to reduce air pollution caused by ships by lowing the upper limit of ship fuel oil sulfur content from 3.5% to 0.5% for ships passing through all sea areas around the world. Although it is important to reduce air pollutants by using fuel oil with low sulfur content, reducing the amount of energy waste through the economic operation of a ship can also help reduce air pollutants. Ships can follow designated routes accurately even under the influence of noise using autopilot systems. However, regardless of their quality, the performance of these systems is af ected by noise; heading angles with added measurement noise from the gyroscope are input into the autopilot system and degrade its performance. A technique to solve these problems reduces noise effects through the application of a Kalman filter, which is widely used in condition estimation. This method, however, cannot completely eliminate the effects of noise. Therefore, to further improve noise removal performances, in this study we propose a better denoising method than the Kalman filter technique by applying a multi-layer perceptron (MLP) in forward direction motion and a Kalman Filter in rotation motion. Simulations show that the proposed method improves forward direction motion by preventing the malfunction of a rudder more so than merely using a Kalman Filter.

Facial Contour Extraction in Moving Pictures by using DCM mask and Initial Curve Interpolation of Snakes (DCM 마스크와 스네이크의 초기곡선 보간에 의한 동영상에서의 얼굴 윤곽선 추출)

  • Kim Young-Won;Jun Byung-Hwan
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.43 no.4 s.310
    • /
    • pp.58-66
    • /
    • 2006
  • In this paper, we apply DCM(Dilation of Color and Motion information) mask and Active Contour Models(Snakes) to extract facial outline in moving pictures with complex background. First, we propose DCM mask which is made by applying morphology dilation and AND operation to combine facial color and motion information, and use this mask to detect facial region without complex background and to remove noise in image energy. Also, initial curves are automatically set according to rotational degree estimated with geometric ratio of facial elements to overcome the demerit of Active Contour Models which is sensitive to initial curves. And edge intensity and brightness are both used as image energy of snakes to extract contour at parts with weak edges. For experiments, we acquired total 480 frames with various head-poses of sixteen persons with both eyes shown by taking pictures in inner space and also by capturing broadcasting images. As a result, it showed that more elaborate facial contour is extracted at average processing time of 0.28 seconds when using interpolated initial curves according to facial rotation degree and using combined image energy of edge intensity and brightness.

Camera Motion Estimation using Geometrically Symmetric Points in Subsequent Video Frames (인접 영상 프레임에서 기하학적 대칭점을 이용한 카메라 움직임 추정)

  • Jeon, Dae-Seong;Mun, Seong-Heon;Park, Jun-Ho;Yun, Yeong-U
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.39 no.2
    • /
    • pp.35-44
    • /
    • 2002
  • The translation and the rotation of camera occur global motion which affects all over the frame in video sequence. With the video sequences containing global motion, it is practically impossible to extract exact video objects and to calculate genuine object motions. Therefore, high compression ratio cannot be achieved due to the large motion vectors. This problem can be solved when the global motion compensated frames are used. The existing camera motion estimation methods for global motion compensation have a large amount of computations in common. In this paper, we propose a simple global motion estimation algorithm that consists of linear equations without any repetition. The algorithm uses information .of symmetric points in the frame of the video sequence. The discriminant conditions to distinguish regions belonging to distant view from foreground in the frame are presented. Only for the distant view satisfying the discriminant conditions, the linear equations for the panning, tilting, and zooming parameters are applied. From the experimental results using the MPEG test sequences, we can confirm that the proposed algorithm estimates correct global motion parameters. Moreover the real-time capability of the proposed technique can be applicable to many MPEG-4 and MPEG-7 related areas.

Reconstruction of Tibial Defects in Lower Extremity With Various Versions of Vascularized Fibula Transfer (다양한 형태의 생 비골 이식술을 이용한 경골의 재건)

  • Nam, Sang-Hyun;Kim, Bom-Jin;Koh, Sung-Hoon;Chung, Yoon-Kyu
    • Archives of Reconstructive Microsurgery
    • /
    • v.15 no.1
    • /
    • pp.17-25
    • /
    • 2006
  • Twelve cases in eleven patients with segmental bone defects were treated with contralateral fibula free flap and ipsilateral island fibula flap in an antegrade, retrograde or bidirectional flow fashion. Five cases were managed with free flaps and seven were with ipsilateral fibula island transfer. Among seven cases, antegrade fashion was three, retrograde was three, and bidirectional was one. All patients were related with open tibial fractures and its sequelae except one who had open foot bone fracture. According to Gustilo's classification, ten patients were type IIIb and one was type IIIc. Basically, antegrade-flow flaps based on the peroneal vessels as in the conventional free flap were used for the proximal or middle one-third tibial defects. On the contrary, retrograde-flow flaps based on the communicating branch between the peroneal and posterior tibial vessels were used for the middle or distal one-third of the tibia. Bidirection-flow flap based on intact peroneal vessels were used for the middle portion of the tibia. The patients who have undergone ipsilateral fibula island flap had one of the following problems: a previously failed free flap, below-knee amputation of the opposite leg because of open tibial fracture, refusal to use the contralateral sound leg, or poor general condition to stand a lengthy operation. Six of the patients who have got ipsilateral fibula island flap also had an associated fibula fracture on the same leg, which was ultimately used as one of the osteotomy sites. The follow-up period was from 1 to 10 years. Two cases of free flap were failed: one patient had below-knee amputation and the other patient had ipsilateral fibula transfer. Other cases were successful and excellent hypertophy of the transferred fibula was achieved. Time to bone union ranged from 4 to 11 months. Time to full weight bearing was from 5 to 13 months after surgery. All of the transferred fibulas showed hypertrophy after weight bearing. In one case, stress fracture was developed during ambulation, which was healed conservatively. Nonunion occurred in two cases, which were treated with a long leg cast and cancellous bone graft, respectively. Length discrepancy of the legs was noted. The limb was shorter by an average 0.5 cm in three cases, longer by 1.1 cm in one case. In the case of island fibula transfer, limited arc of rotation was not a problem. Other disabling complications were not seen. We believe that these diverse modalities using a vascularized fibula will make us more comfortable to handle major bone defects.

  • PDF

NOVEL CNC GRINDING PROCESS CONTROL FOR NANOMETRIC SURFACE ROUGHNESS FOR ASPHERIC SPACE OPTICAL SURFACES (우주망원경용 비구면 반사경 표면조도 향상을 위한 진화형 수치제어 연삭공정 모델)

  • 한정열;김석환;김건희;김대욱;김주환
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.2
    • /
    • pp.141-152
    • /
    • 2004
  • Optics fabrication process for precision space optical parts includes bound abrasive grinding, loose abrasive lapping and polishing. The traditional bound abrasive grinding with bronze bond cupped diamond wheel leaves the machine marks of about $20{mu}m$ rms in height and the subsurface damage of about 1 ${mu}m$ rms in height to be removed by subsequent loose abrasive lapping. We explored an efficient quantitative control of precision CNC grinding. The machining parameters such as grain size, work-piece rotation speed and feed rate were altered while grinding the work-piece surfaces of 20-100 mm in diameter. The input grinding variables and the resulting surface quality data were used to build grinding prediction models using empirical and multi-variable regression analysis. The effectiveness of such grinding prediction models was then examined by running a series of precision CNC grinding operation with a set of controlled input variables and predicted output surface quality indicators. The experiment achieved the predictability down to ${pm}20$ nm in height and the surface roughness down to 36 nm in height. This study contributed to improvement of the process efficiency reaching directly the polishing and figuring process without the need for the loose abrasive lapping stage.

Polarization Precession Effects for Shear Elastic Waves in Rotated Solids

  • Sarapuloff, Sergii A.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.842-848
    • /
    • 2013
  • Developments of Solid-State Gyroscopy during last decades are impressive and were based on thin-walled shell resonators like HRG or CRG made from fused quartz or leuko-sapphire. However, a number of design choices for inertial-grade gyroscopes, which can be used for high-g applications and for mass- or middle-scale production, is still very limited. So, considerations of fundamental physical effects in solids that can be used for development of a miniature, completely solid-state, and lower-cost sensor look urgent. There is a variety of different types of bulk acoustic (elastic) waves (BAW) in anisotropic solids. Shear waves with different variants of their polarization have to be studied especially carefully, because shear sounds in glasses and crystals are sensitive to a turn of the solid as a whole, and, so, they can be used for development of gyroscopic sensors. For an isotropic medium (for a glass or a fine polycrystalline body), classic Lame's theorem (so-called, a general solution of Elasticity Theory or Green-Lame's representation) has been modified for enough general case: an elastic medium rotated about an arbitrary set of axes. Travelling, standing, and mixed shear waves propagating in an infinite isotopic medium (or between a pair of parallel reflecting surfaces) have been considered too. An analogy with classic Foucault's pendulum has been underlined for the effect of a turn of a polarizational plane (i.e., an integration effect for an input angular rate) due to a medium's turn about the axis of the wave propagation. These cases demonstrate a whole-angle regime of gyroscopic operation. Single-crystals are anisotropic media, and, therefore, to reflect influence of the crystal's rotation, classic Christoffel-Green's tensors have been modified. Cases of acoustic axes corresponding to equal velocities for a pair of the pure-transverse (shear) waves have of an evident applied interest. For such a special direction in a crystal, different polarizations of waves are possible, and the gyroscopic effect of "polarizational precession" can be observed like for a glass. Naturally, formation of a wave pattern in a massive elastic body is much more complex due to reflections from its boundaries. Some of these complexities can be eliminated. However, a non-homogeneity has a fundamental nature for any amorphous medium due to its thermodynamically-unstable micro-structure, having fluctuations of the rapidly-frozen liquid. For single-crystalline structures, blockness (walls of dislocations) plays a similar role. Physical nature and kinematic particularities of several typical "drifts" in polarizational BAW gyros (P-BAW) have been considered briefly too. They include irregular precessions ("polarizational beats") due to: non-homogeneity of mass density and elastic moduli, dissymmetry of intrinsic losses, and an angular mismatch between propagation and acoustic axes.

  • PDF

Analysis and Compensation of Time Synchronization Error on SAR Image (시각 동기화 오차가 SAR 영상에 미치는 영향 분석 및 보상)

  • Lee, Soojeong;Park, Woo Jung;Park, Chan Gook;Song, Jong-Hwa;Bae, Chang-Sik
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.4
    • /
    • pp.285-293
    • /
    • 2020
  • In this paper, to improve Synthetic Aperture Radar (SAR) image quality, the effect of time synchronization error in the EGI/IMU (Embedded GPS/INS, Inertial Measurement Unit) integrated system is analyzed and state augmentation is applied to compensate it. EGI/IMU integrated system is widely used as a SAR motion measurement algorithm, which consists of EGI mounted to obtain the trajectory and IMU mounted on the SAR antenna. In an EGI/IMU integrated system, a time synchronization error occurs when the clocks of the sensors are not synchronized. Analysis of the effect of time synchronization error on navigation solutions and SAR images confirmed that the time synchronization error deteriorates SAR image quality. The state augmentation is applied to compensate for this and as a result, the SAR image quality does not decrease. In addition, by analyzing the performance and the observability of the time synchronization error according to the maneuver, it was confirmed that the time-variant maneuver such as rotational motion is necessary to estimate the time synchronization error adequately. In order to reduce the influence of the time synchronization error on the SAR image, the time synchronization error must be compensated by performing maneuver changing over time such as a rotation before SAR operation.