• Title/Summary/Keyword: Rotation Operation

Search Result 388, Processing Time 0.028 seconds

Treatment of Multidirectional Instability of the Shoulder with Inferior Capsular Shift (하방 관절낭 이동술을 이용한 다방향 견관절 불안정의 치료)

  • Lee Byoung Chang;Chun Churl Hong;Park Seong Kyu
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.2
    • /
    • pp.79-86
    • /
    • 2000
  • Purpose: We analysed the clinical efficacy of inferior capsular shift operation in multidirectional instability of the shoulder joint in terms of functional aspects and patient's satisfaction Materials and Methods: From July, 1998 to March, 2000, we treated 23 cases of multidirectional instability of the shoulder joint with T-shaped inferior capsular shift and/or Bankart repair. All of them have complained of an experience about frank dislocations. Two of them has a voluntary component. We evaluated them according to complication, function, range of motion, stability and patient's satisfaction with an average follow-up of 15 months(the range of 9 to 27 months). Results: Eight cases were atraumatic multidirectional instability and coexisting Bankart lesion were present in 15. There was no redislocation, but one case of symptomatic subluxation, 3 cases of transient nerve palsy and 2 cases of feeling of laxity developed. Limitation of motion after surgery was an average of 3.4° in flexion, and 8.5° in external rotation. With Rowe scoring system, the clinical result was excellent or good in 22 cases and poor in one. According to American shoulder and elbow society, pain score improved to 1.4 from 6.1, and stability score also improved to 1.8 from 9.1. Conclusion: In multidirectional shoulder instability, one should pay attention to finding a coexisting Bankart lesion. In that case, adequate capsular volume reduction by using inferior capsular shift as well as repair of Bankart lesion is needed to get a good surgical outcome.

  • PDF

A Study on Development of Shutoff Operating System of Ultra-High Pressure Positive Displacement Pump (초고압 용적형 펌프의 체절운전시스템 개발에 관한 연구)

  • Min, Se-Hong;Kim, Ho-Chul;Sung, Gi-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.106-113
    • /
    • 2016
  • Ultra-high pressure positive displacement pump can discharge high pressure water with mass volume, which depends on periodic changes in volume that made by rotation motor. Its high efficiency of discharge is one of the most strong point of positive displacement pump. Due to its simple system structure, it can be miniaturized and lightened. Positive displacement pump can discharge high pressure with stable flow rate, irrespective of pressure fluctuate. This is the reason that positive displacement pump was used instead of centrifugal pump. In this study, shutoff operating system was developed for positive displacement pump to secure safety of high pressure operate. This shutoff system contains controller system, electronic clutch, and relief valve, and each part is mutual supplementation. Speed test was carried out in order to check operation of controller program and electronic clutch and fluid flow, venting experiment of the relief valve. It was confirmed that segment system of ultra-high pressure positive displacement pump is operated.

견관절의 결절종 제거수술후 발생한 SLAP병변 -증례보고 1예-

  • Kim, Won-Yu;Ji, Jong-Hun;Kim, Jin-Yeong;Yang, Yeong-Jun;O, Se-Cheol;Kim, Ji-Chang
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 2005.03a
    • /
    • pp.107-111
    • /
    • 2005
  • 29 year-old male was suffered from deep shoulder pain and muscle weakness 2 years ago. Recently 2 month ago lancinating shoulder pain and night pain was progressed. physical examination and MRI and EMG finding showed suprascapular nerve compression syndrome due to ganglion cyst in the shoulder joint. Arthroscopic ganglion cyst excision was performed and his symptoms was improved. 2 years later shoulder pain was developed in abduction and external rotation position and mild discomfort was continued. In second operation, SLAP lesion was found and arthroscopic SLAP repair was performed. Our case presented SLAP lesion occurred arthroscopic ganglion excision in the shoulder joint 2 years later.

  • PDF

Treatment of Anteroinferior Tibiofibular Ligament Avulsion Fracture Accompanied with Ankle Fracture (족관절 골절과 동반된 전하 경비 인대 견열 골절의 치료)

  • Chung, Hyung-Jin;Bae, Su-Young;Kim, Man-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.1
    • /
    • pp.13-17
    • /
    • 2011
  • Purpose: To evaluate the clinical results of anteroinferior tibiofibular ligament avulsion fracture accompanied ankle fractures treated with anatomical reduction and internal fixation. Materials and Methods: From January 2007 to April 2010, 30 cases with anteroinferior tibiofibular ligament avulsion fracture that treated with anatomical reduction and internal fixation were analyzed. The average follow-up period was 26 months (minimum 6 months). We have reviewed the bony union, complication and subjective satisfaction according to the fracture classification and method of internal fixation. Results: Among 30 cases, 28 cases were occurred in Lauge-Hansen classification supination-external rotation type, one case was fracture-dislocation and one case was Maisonneuve fracture. We have performed internal fixation with Mini screw in 11 cases, K-wire in 10 cases, repair in six cases and Mini screw & K-wire in three cases. In all cases bony union was completed. two cases in Mini screw, one case in K-wire, two cases in repair and one case in Mini screw & K-wire revealed LOM of ankle joint. Skin irritation and superficial peroneal nerve irritation happened in one case each. Other cases show good subjective satisfaction. Conclusion: Anteroinferior tibiofibular ligament avulsion fracture accompanied with ankle fracture is a good clinical outcome with internal fixation. So we should not miss out the anteroinferior tibiofibular ligament avulsion fracture in radiologic evaluation or operation room.

Cubical User Interface for Toy Block Composition in Augmented Reality (증강 현실에서의 장난감 블록 결합을 위한 큐브형 사용자 인터페이스)

  • Lee, Hyeong-Mook;Lee, Young-Ho;Woo, Woon-Tack
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.363-367
    • /
    • 2009
  • We propose Cubical User Interface(CUI) for toy block composition in Augmented Reality. The creation of new object by composing virtual object is able to construct various AR contents effectively. However, existing GUI method requires learning time or is lacking of intuitiveness between act of user and offered interface. In case of AR interfaces, they mainly have been supported one handed operation and it did not consider composition property well. Therefore, the CUI provide tangible cube as the manipulation tool for virtual toy block composition in AR. The tangible cube which is attached multi-markers, magnets, and buttons supports free rotation, combination, and button input. Also, we propose two kinds of two-handed composing interactions based on CUI. First is Screw Driving(SD) method which is possible to free 3-D positioning and second is Block Assembly(BA) method which support visual guidance and is fast and intuitive. We expected that proposed interface can apply as the authoring system for content such as education, entertainment, Digilogbook.

  • PDF

Sliding Mode Control Based on 3-Loop of a Pneumatic Motor (공압모터의 3-루프 기반 슬라이딩 모드 제어)

  • Kim, Geun-Mook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.11
    • /
    • pp.6446-6451
    • /
    • 2014
  • Pneumatic motors are quite attractive for many applications because of their competitive price, light-weight, easy assembly, safety in hazardous areas as well as other features, such as a good force/weight ratio and operation in exceptionally harsh environments. In contrast to these advantages, pneumatic motors have limited use in applications, particularly those requiring a fast and precise response. These undesirable characteristics are due to the high compressibility of air and from the nonlinearities in pneumatic systems. This paper presents the sliding mode controller based on 3-loop(SMCB3L), which increases the load stiffness to control the rotation angle of a pneumatic motor. The characteristics for the step responses and load disturbances of the proposed controller were compared with the conventional PID controller. The experimental results showed that a properly designed SMCB3L is capable of high positioning accuracy within ${\pm}0.05mm$. Furthermore, the load stiffness of the SMCB3L can be improved 3.5 fold compared to that of PID controllers.

Strategy of Purchasing Management for Hotel Food Materials (호텔 식자재 구매관리 전략)

  • Park, Jae-Wan
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.10
    • /
    • pp.302-310
    • /
    • 2007
  • This research, through an empirical analysis of the management of food materials in the super deluxe and deluxe hotels in Seoul, verified the difference, and established strategies according to the difference. According to the study, to enhance the level of the food material management, the introduction of scientific methods and system of the deluxe hotels has to be preceded, the training of special inspectors and the utilization of inspection methods needs improvement, and the purchasing contracts and effective purchasing methods have to be renewed. As for the storing management, the difference between hotel grades was low. The implication of this study as follows. First, to enhance the efficiency of man power operation, we have to introduce computer systems. Second, training based on the food materials purchasing manual has to be achieved. Third, we have to increase inspectors' specialty through the arrangement of man power rotation.

FPGA Design of a SURF-based Feature Extractor (SURF 알고리즘 기반 특징점 추출기의 FPGA 설계)

  • Ryu, Jae-Kyung;Lee, Su-Hyun;Jeong, Yong-Jin
    • Journal of Korea Multimedia Society
    • /
    • v.14 no.3
    • /
    • pp.368-377
    • /
    • 2011
  • This paper explains the hardware structure of SURF(Speeded Up Robust Feature) based feature point extractor and its FPGA verification result. SURF algorithm produces novel scale- and rotation-invariant feature point and descriptor which can be used for object recognition, creation of panorama image, 3D Image restoration. But the feature point extraction processing takes approximately 7,200msec for VGA-resolution in embedded environment using ARM11(667Mhz) processor and 128Mbytes DDR memory, hence its real-time operation is not guaranteed. We analyzed integral image memory access pattern which is a key component of SURF algorithm to reduce memory access and memory usage to operate in c real-time. We assure feature extraction that using a Vertex-5 FPGA gives 60frame/sec of VGA image at 100Mhz.

CLINICAL STUDY OF SURGICAL TREATMENTS ON CLEFT LIP AND CLEFT PALATE (순열 및 구개열 환자의 외과적 치료방법에 관한 임상적 연구)

  • Shin, Byung-Chol;Lee, Dong-Keun;Sung, Gil-Hyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.18 no.4
    • /
    • pp.529-545
    • /
    • 1996
  • In order to find the distribution, causes and treatments of cleft lip and/or palate, I analyzed 113 patients of cleft lip and/or palate who were treated in the Department of Oral and Maxillofacial Surgery, School of Dentistry, Wonkwang University, Iksan, Chunbuk, KOREA from September 1984 to August 1995. The obtained results were as follows. 1. In total 113 patients of cleft lip and/or palate, male patients were 63 cases (56%) and female patients were 50 cases (44%). 2. In distribution of cleft lip and/or palate, cleft lip patients were 30 cases (27%), cleft palate patient were 23 cases (20%) and cleft lip and palate patients were 60 cases (53%). 3. Unilateral cleft lip patients (78 cases: 87%) were larger than bilateral cleft lip. In unilateral cleft lip patients, lip side cleft lip patients (45 cases: 50%) were larger than right side cleft lip patients (33 cases: 37%). 4. Possible causes of cleft lip and/or palate were related with familial tendency, drug intoxication, malnutrition, old maternal age, stress and hypoxia during 4-8 weeks of pregnancy period. 5. The favorite treated method of cleft lip was Millard rotation-advancement method. Probably the most popular operated period was 3 months. 6. The useful operating technique of cleft palate was Wardill V-Y flap method. The most popular period has been 18 to 24 months. 7. In 11 patients with velopharyngeal insufficiency, hypernasality decreased by superior based pharyngeal flap pharyngoplasty. 8. Cleft alveolus was treated with autogenous and allogeneic bone graft. The most appropriate operation period was 9 to 11 years.

  • PDF

A Study on the High-power Low-loss Dual Axes Waveguide Rotary Joint for Ka-Band Millimeter-Wave Small Radar (밀리미터파대역(Ka-대역)소형 레이더용 고 전력 저 손실 2축 도파관 로터리 조인트 연구)

  • Jung, Chae-Hyun;Sung, Jong-Hyun;Baek, Jong-Gyun;Lee, Kook-Joo;Park, Chang-Hyun;Kwon, Jun-Beom
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.1
    • /
    • pp.91-96
    • /
    • 2018
  • In this paper, dual axes waveguide rotary joint, which operates at high power and has low loss characteristic, is designed and fabricated for a Ka-band millimeter-wave small radar. Its electrical performance is verified through the S-parameter at room temperature, high power and operation temperature test. Rotary joint functionally consists of the mode converter transforming rectangular waveguide into circular waveguide and the choke at the rotation part. At the configuration design, linking a fixed transmitter to an antenna rotating dual axes electrically for minimum loss and light weight body are considered. In Fc(center frequency)${\pm}500MHz$, the designed rotary joint has VSWR 1.5:1 below return loss, -2.0 dB above insertion loss. It is found that rotary joint characteristics is similar to design results.